Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 111
Filtrar
2.
Artículo en Inglés | MEDLINE | ID: mdl-38518357

RESUMEN

PURPOSE: Rapid on-site-evaluation (ROSE) is a technique aimed at improving the diagnostic performance of computed tomography (CT)-guided core needle biopsy (CNB) in lung cancer. The aim of this retrospective study was to investigate the impact of ROSE on the rate of nondiagnostic specimens and on accuracy computed on diagnostic specimens. MATERIALS AND METHODS: During a 3-year period, 417 CT-guided CNBs were performed at our center. The biopsies were retrospectively classified into 2 groups: 141 procedures were assisted by ROSE and 276 were not. All of them were reviewed for clinical, procedural, and pathological data. Pathology results were classified as diagnostic (positive or negative for malignancy) or nondiagnostic. The results were compared with the final diagnosis after surgery or clinical follow-up. Nondiagnostic rate, sensitivity/specificity/negative predictive value/positive predictive value for the ROSE and non-ROSE groups were calculated. Finally, procedural complications and the adequacy of the specimens for the molecular analysis were recorded. RESULTS: The study evaluated 417 CNBs (mean patients' age 71 years, 278 men). Nondiagnostic rates with and without ROSE were 4% (6/142) and 11% (29/276), respectively (P = 0.028). Sensitivity/specificity/negative predictive value/positive predictive value with and without ROSE did not show statistically significant differences, and no difference in major/minor complication rates was observed between the 2 groups. The adequacy of specimen for subsequent molecular analysis was 100% with (42/42) and 82% without ROSE (51/62). CONCLUSIONS: Rapid on-site-evaluation reduced the rate of nondiagnostic specimens by 50% with no change in complication rates or accuracy and increased by 20% the chances of a successful subsequent molecular analysis.

3.
J Comput Assist Tomogr ; 48(3): 354-360, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38346811

RESUMEN

OBJECTIVE: Magnetic resonance (MR) relaxometry is an absolute and reproducible quantitative method, compared with signal intensity for the evaluation of liver biliary function. This is obtainable by the T1 reduction rate (T1RR), as it carries a smaller systematic error than the pre/post contrast agent T1 measurement. We aimed to develop and test an MR T1 relaxometry tool tailored for the evaluation of liver T1RR after gadolinium ethoxybenzyl-diethylenetriaminepentaacetic acid administration on 1.5T MR. METHODS: In vitro/vivo (liver) T1RR values with two 3D FLASH variable-flip-angle sequences were calculated by a MATLAB algorithm. In vitro measurements were done by 2 physicists, in consensus. The prospective in vivo study was approved by the local ethical committee and performed on 13 normal/26 cirrhotic livers. A supplemental test in 5 normal/5 cirrhotic livers, out of the studied series, was done to compare the results of our method (without B1 inhomogeneity correction) and those of a standardized commercial tool (with B1 inhomogeneity correction). All in vivo evaluations were performed by 2 radiologists with 7 years of experience in abdominal imaging. Open-source Java-based software ImageJ was used to draw the free-hand regions of interest on liver section and for the measurement of hepatic T1RR values. The T1RR values of each group of patients were compared to assess statistically significant differences. All statistical analyses were performed with IBM-SPSS Statistics. In vivo evaluations, the intrareader and interreader reliability was assessed by intraclass correlation coefficient. RESULTS: Our method showed good accuracy in evaluating in vitro T1RR with a maximum percentage error of 9% (constant at various time points) with T1 values in the 200- to 1400-millisecond range. In vivo, a high concordance between the T1RR evaluated with the proposed method and that calculated from the standardized commercial software was verified ( P < 0.05). The median T1RRs were 74.8, 67.9, and 52.1 for the normal liver, Child-Pugh A, and Child-Pugh B cirrhotic groups, respectively. A very good agreement was found, both within intrareader and interreader reliability, with intraclass correlation coefficient values ranging from 0.88 to 0.95 and from 0.85 to 0.90, respectively. CONCLUSIONS: The proposed method allowed accurate reliable in vitro/vivo T1RR assessment evaluation of the liver biliary function after gadolinium ethoxybenzyl-diethylenetriaminepentaacetic acid administration.


Asunto(s)
Medios de Contraste , Gadolinio DTPA , Hígado , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Femenino , Persona de Mediana Edad , Estudios Prospectivos , Hígado/diagnóstico por imagen , Adulto , Anciano , Reproducibilidad de los Resultados , Algoritmos , Cirrosis Hepática/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos
5.
Eur J Radiol ; 170: 111239, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38056347

RESUMEN

BACKGROUND: MRI is a radiation-free emerging alternative to CT in systemic sclerosis related interstitial lung disease (SSc-ILD) assessment. We aimed to compare a T2 radial TSE and a PD UTE MRI sequence with CT in SSc-ILD extent evaluation and correlations with pulmonary function tests (PFT). MATERIAL AND METHODS: 29 SSc-ILD patients underwent CT, MRI and PFT. ILD extent was visually assessed. Lin's concordance correlation coefficients (CCC) and Kruskal Wallis test (p-value < 0.05) were computed for inter-method comparison. Patients were divided in limited and extended disease, defining extended ILD with two methods: (A) ILD>30% or 10%20% or 20% with FVC%<70%. MRI Sensitivity, Specificity, Positive Predictive Value (PPV), Negative Predictive Value (NPV) and Accuracy were assessed. Pearson correlation coefficients r (p-value<0.025) were computed between ILD extents and PFT (FVC% and DLCO%). RESULTS: Median ILD extents were 11%, 11%, 10% on CT, radial TSE and UTE, respectively. CCC between CT and MRI was 0.95 for both sequences (Kruskal-Wallis p-value=0.64). Sensitivity, Specificity, PPV, NPV and Accuracy in identifying extended disease were: (A) 87.5 %, 100 %, 100 %, 95.5 and 96.6 % with radial TSE and 87.5 %, 95.2 %, 87.5 %, 95.2 and 93.1 % with UTE; (B) 86.7 %, 86.4 %, 66.7 %, 95.0 % and 86.2 % for both sequences. Pearson r of CT, radial TSE and UTE ILD extents with FVC were -0.66, -0.60 and -0.68 with FVC, -0.59, -0.56 and -0.57 with DLCO, respectively (p<0.002). CONCLUSIONS: MRI sequences may have similar accuracy to CT to determine SSc-ILD extent and severity, with analogous correlations with PFT.


Asunto(s)
Enfermedades Pulmonares Intersticiales , Esclerodermia Sistémica , Humanos , Pulmón/diagnóstico por imagen , Enfermedades Pulmonares Intersticiales/diagnóstico por imagen , Enfermedades Pulmonares Intersticiales/etiología , Esclerodermia Sistémica/complicaciones , Esclerodermia Sistémica/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Imagen por Resonancia Magnética , Pruebas de Función Respiratoria
6.
BMC Pulm Med ; 23(1): 472, 2023 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-38007479

RESUMEN

BACKGROUND: COVID-19 is a pandemic disease affecting predominantly the respiratory apparatus with clinical manifestations ranging from asymptomatic to respiratory failure. Chest CT is a crucial tool in diagnosing and evaluating the severity of pulmonary involvement through dedicated scoring systems. Nonetheless, many questions regarding the relationship of radiologic and clinical features of the disease have emerged in multidisciplinary meetings. The aim of this retrospective study was to explore such relationship throughout an innovative and alternative approach. MATERIALS AND METHODS: This study included 550 patients (range 25-98 years; 354 males, mean age 66.1; 196 females, mean age 70.9) hospitalized for COVID-19 with available radiological and clinical data between 1 March 2021 and 30 April 2022. Radiological data included CO-RADS, chest CT score, dominant pattern, and typical/atypical findings detected on CT examinations. Clinical data included clinical score and outcome. The relationship between such features was investigated through the development of the main four frequently asked questions summarizing the many issues arisen in multidisciplinary meetings, as follows 1) CO-RADS, chest CT score, clinical score, and outcomes; 2) the involvement of a specific lung lobe and outcomes; 3) dominant pattern/distribution and severity score for the same chest CT score; 4) additional factors and outcomes. RESULTS: 1) If CT was suggestive for COVID, a strong correlation between CT/clinical score and prognosis was found; 2) Middle lobe CT involvement was an unfavorable prognostic criterion; 3) If CT score < 50%, the pattern was not influential, whereas if CT score > 50%, crazy paving as dominant pattern leaded to a 15% increased death rate, stacked up against other patterns, thus almost doubling it; 4) Additional factors usually did not matter, but lymph-nodes and pleural effusion worsened prognosis. CONCLUSIONS: This study outlined those radiological features of COVID-19 most relevant towards disease severity and outcome with an innovative approach.


Asunto(s)
COVID-19 , Masculino , Femenino , Humanos , Anciano , COVID-19/diagnóstico por imagen , SARS-CoV-2 , Estudios Retrospectivos , Pulmón/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos
7.
Acta Radiol Open ; 12(4): 20584601231168967, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37101461

RESUMEN

Background: The newly adopted European directive DE59/2013 mandates adequate patient information in procedures involving ionising radiation. Patient interest in knowing about their radiation dose and an effective communication method for dose exposure remain poorly investigated. Purpose: This study is aimed at investigating both patient interest in radiation dose and an effective method to communicate radiation dose exposure. Material and methods: The present analysis is based on a multi-centre cross-sectional data collection involving 1,084 patients from four different hospitals ‒ two general and two paediatric hospitals. Anonymous questionnaires were administered, consisting of an initial overview of radiation use in imaging procedures, a patient data section, and an explanatory section providing information in four modalities. Results: 1009 patients were included in the analysis, with 75 refusing participation; 173 participants were relatives of paediatric patients. Initial information provided to patients was considered comprehensible. The information modality with symbols was considered the most readily understandable format by patients, with no appreciable differences in comprehension attributable to social or cultural background. The modality including dose numbers and diagnostic reference levels was preferred by patients with higher socio-economic background. The option 'None of those' was selected by one-third of our sample population, composed of four different clusters: female, over 60 years old, unemployed, and from low socio-economic backgrounds. Conclusions: This study demonstrated a high level of interest amongst patients in knowing about radiation dose exposure. Pictorial representations were well understood by patients from a variety of different ages and education levels. However, a universally comprehensible model of communicating radiation dose information remains to be elucidated.

8.
J Magn Reson Imaging ; 58(5): 1386-1405, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-36988385

RESUMEN

BACKGROUND: Peliosis hepatis (PH) is a rare benign condition, characterized by hepatic sinusoidal dilatation and blood-filled cystic cavities, often found incidentally, with still challenging diagnosis by imaging due to polymorphic appearance. PURPOSE: Based on a retrospective analysis of our series (12 patients) and systematic literature review (1990-2022), to organize data about PH and identify features to improve characterization. STUDY TYPE: Retrospective case series and systematic review. POPULATION: Twelve patients (mean age 48 years, 55% female) with pathology-proven PH and 49 patients (mean age 52 years, 67% female) identified in 33 studies from the literature (1990-2022). FIELD STRENGTH/SEQUENCE: 1,5-T; T1-weighted (T1W), T2-weighted (T2W), diffusion-weighted (DW), contrast-enhanced (CE) T1W imaging. ASSESSMENT: We compared our series and literature data in terms of demographic (gender/age/ethnicity), clinical characteristics (symptoms/physical examination/liver test), associated conditions (malignancies/infectious/hematologic/genetic or chronic disorders/drugs or toxic exposure) percentage. On magnetic resonance imaging lesion numbers/shape/mean maximum diameter/location/mass effect/signal intensity were compared. PH pathological type/proposed imaging diagnosis/patient follow-up were also considered. STATISTICAL TESTS: Joanna Briggs Institute (JBI) Critical Appraisal Checklist for Case Reports/Series quality assessment. Intraclass correlation and Cohen's kappa coefficients for levels of inter/intrareader agreement in our experience. RESULTS: Patients were mainly asymptomatic (92% vs. 70% in our study and literature) with associated conditions (83% vs. 80%). Lesions showed homogeneous T1W-hypointensity (58% vs. 65%) and T2W-hyperintensity (58% vs. 66%). Heterogeneous nonspecific (25% vs. 51%), centrifugal (34% vs. 8%), or rim-like centripetal (25% vs. 23%) patterns of enhancement were most frequent, with hypointensity on the hepatobiliary phase (HBP), without restricted diffusivity. Good inter- and intrareader agreement was observed in our experience. Concerning JBI Checklist, 19 out of 31 case reports met at least 7 out of 8 criteria, whereas 2 case series fulfilled 5 and 6 out of 10 items respectively. DATA CONCLUSION: A homogeneous, not well-demarcated T1W-hypointense and T2W-hyperintense mass, with heterogeneous nonspecific or rim-like centripetal or centrifugal pattern of enhancement, and hypointensity on HBP, may be helpful for PH diagnosis. Among associated conditions, malignancies and drug exposures were the most frequent. LEVEL OF EVIDENCE: 4 TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Peliosis Hepática , Humanos , Femenino , Persona de Mediana Edad , Masculino , Peliosis Hepática/diagnóstico por imagen , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Carcinoma Hepatocelular/patología , Neoplasias Hepáticas/patología , Medios de Contraste
9.
J Thorac Imaging ; 38(2): 97-103, 2023 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-35482025

RESUMEN

PURPOSE: To test respiratory-triggered ultrashort echo-time (UTE) Spiral VIBE-MRI sequence in systemic sclerosis-interstitial lung disease assessment compared with computed tomography (CT). MATERIAL AND METHODS: Fifty four SSc patients underwent chest CT and UTE (1.5 T). Two radiologists, independently and in consensus, verified ILD presence/absence and performed a semiquantitative analysis (sQA) of ILD, ground-glass opacities (GGO), reticulations and honeycombing (HC) extents on both scans. A CT software quantitative texture analysis (QA) was also performed. For ILD detection, intra-/inter-reader agreements were computed with Cohen K coefficient. UTE sensitivity and specificity were assessed. For extent assessments, intra-/inter-reader agreements and UTE performance against CT were computed by Lin's concordance coefficient (CCC). RESULTS: Three UTE were discarded for low quality, 51 subjects were included in the study. Of them, 42 QA segmentations were accepted. ILD was diagnosed in 39/51 CT. UTE intra-/inter-reader K in ILD diagnosis were 0.56 and 0.26. UTE showed 92.8% sensitivity and 75.0% specificity. ILD, GGO, and reticulation extents were 14.8%, 7.7%, and 7.1% on CT sQA and 13.0%, 11.2%, and 1.6% on CT QA. HC was <1% and not further considered. UTE intra-/inter-reader CCC were 0.92 and 0.89 for ILD extent and 0.84 and 0.79 for GGO extent. UTE RET extent intra-/inter-reader CCC were 0.22 and 0.18. UTE ILD and GGO extents CCC against CT sQA and QA were ≥0.93 and ≥0.88, respectively. RET extent CCC were 0.35 and 0.22 against sQA and QA, respectively. CONCLUSION: UTE Spiral VIBE-MRI sequence is reliable in assessing ILD and GGO extents in systemic sclerosis-interstitial lung disease patients.


Asunto(s)
Enfermedades Pulmonares Intersticiales , Esclerodermia Sistémica , Humanos , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Sensibilidad y Especificidad , Pulmón
10.
Rheumatology (Oxford) ; 62(2): 696-706, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-35708639

RESUMEN

OBJECTIVES: It has recently become possible to assess lung vascular and parenchymal changes quantitatively in thoracic CT images using automated software tools. We investigated the vessel parameters of patients with SSc, quantified by CT imaging, and correlated them with interstitial lung disease (ILD) features. METHODS: SSc patients undergoing standard of care pulmonary function testing and CT evaluation were retrospectively evaluated. CT images were analysed for ILD patterns and total pulmonary vascular volume (PVV) extents with Imbio lung texture analysis. Vascular analysis (volumes, numbers and densities of vessels, separating arteries and veins) was performed with an in-house developed software. A threshold of 5% ILD extent was chosen to define the presence of ILD, and commonly used cut-offs of lung function were adopted. RESULTS: A total of 79 patients [52 women, 40 ILD, mean age 56.2 (s.d. 14.2) years, total ILD extent 9.5 (10.7)%, PVV/lung volume % 2.8%] were enrolled. Vascular parameters for total and separated PVV significantly correlated with functional parameters and ILD pattern extents. SSc-associated ILD (SSc-ILD) patients presented with an increased number and volume of arterial vessels, in particular those between 2 and 4 mm of diameter, and with a higher density of arteries and veins of <6 mm in diameter. Considering radiological and functional criteria concomitantly, as well as the descriptive trends from the longitudinal evaluations, the normalized PVVs, vessel numbers and densities increased progressively with the increase/worsening of ILD extent and functional impairment. CONCLUSION: In SSc patients CT vessel parameters increase in parallel with ILD extent and functional impairment, and may represent a biomarker of SSc-ILD severity.


Asunto(s)
Enfermedades Pulmonares Intersticiales , Esclerodermia Sistémica , Humanos , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Esclerodermia Sistémica/complicaciones , Esclerodermia Sistémica/diagnóstico por imagen , Pulmón , Enfermedades Pulmonares Intersticiales/etiología , Enfermedades Pulmonares Intersticiales/complicaciones , Biomarcadores
11.
Abdom Radiol (NY) ; 47(8): 2795-2810, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35648207

RESUMEN

PURPOSE: Inflammatory pseudotumors of the liver (IPTL) are not exceptional benign lesions with various etiologies, histology, and imaging appearances. The incomplete knowledge of this pathology and the wide polymorphism sometimes resembling malignancy often induce long and expensive diagnostic flow, biopsy and occasionally unnecessary surgery. We propose a systematic revision of MRI literature data (2000-2021) with some narrative inserts and 10 new complete MRI cases, with the aim of organizing the data about IPTL and identifying some typical features able to improve its diagnosis from imaging. METHODS: We performed a systematic revision of literature from 2000 to 2021 to obtain MRI features, epidemiological, and clinical data of IPTL. The basic online search algorithm on the PubMed database was "(pseudotumor) AND (liver) AND (imaging)." Quality assessment was performed using both scales by Moola for case report studies and by Munn for cross-sectional studies reporting prevalence data. A case-based retrospective study by collecting patients diagnosed with IPTL from three different university hospitals from 2015 to 2021 was done as well. Only cases with MR examinations complete with T1/T2/contrast-enhanced T1/Diffusion-Weighted (W) images and pathology-proven IPTL were selected. RESULTS: After screening/selection 38 articles were included for a total of 114 patients. In our experience we selected 10 cases for a total of 16 IPTLs; 8 out of 10 patients underwent at least 1 MRI follow-up. Some reproducible and rather typical imaging findings for IPTL were found. The targetoid aspect of IPTL is very frequent in our experience (75% on T1W, 44% on T2W, 81% on contrast-enhanced T1W (at least one phase), 100% on Diffusion-W images) but is also recurrent in the literature (6% on T1W, 31% on T2W, 51% on CE-T1W (at least one phase), 18% on Diffusion-W images, and 67% on hepatobiliary phase). In our experience, Apparent Diffusion Coefficient map values were always equal to or higher than those of the surrounding parenchyma, and at MRI follow-up, nodule/s disappeared at first/second control, in six patients, while in the remaining 2, lesions persisted with tendency to dehydration. CONCLUSION: A targetoid-like aspect of a focal liver lesion must raise diagnostic suspicion, especially if IgG4-positive plasma is detected. MRI follow-up mainly shows the disappearance of the lesion or its reduction with dehydration.


Asunto(s)
Granuloma de Células Plasmáticas , Medios de Contraste , Estudios Transversales , Deshidratación/patología , Imagen de Difusión por Resonancia Magnética , Granuloma de Células Plasmáticas/diagnóstico por imagen , Humanos , Hígado/diagnóstico por imagen , Hígado/patología , Imagen por Resonancia Magnética/métodos , Estudios Retrospectivos
12.
Eur Respir Rev ; 31(163)2022 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-35321929

RESUMEN

OBJECTIVE: Imaging represents an important noninvasive means to assess cystic fibrosis (CF) lung disease, which remains the main cause of morbidity and mortality in CF patients. While the development of new imaging techniques has revolutionised clinical practice, advances have posed diagnostic and monitoring challenges. The authors aim to summarise these challenges and make evidence-based recommendations regarding imaging assessment for both clinicians and radiologists. STUDY DESIGN: A committee of 21 experts in CF from the 10 largest specialist centres in Italy was convened, including a radiologist and a pulmonologist from each centre, with the overall aim of developing clear and actionable recommendations for lung imaging in CF. An a priori threshold of at least 80% of the votes was required for acceptance of each statement of recommendation. RESULTS: After a systematic review of the relevant literature, the committee convened to evaluate 167 articles. Following five RAND conferences, consensus statements were developed by an executive subcommittee. The entire consensus committee voted and approved 28 main statements. CONCLUSIONS: There is a need for international guidelines regarding the appropriate timing and selection of imaging modality for patients with CF lung disease; timing and selection depends upon the clinical scenario, the patient's age, lung function and type of treatment. Despite its ubiquity, the use of the chest radiograph remains controversial. Both computed tomography and magnetic resonance imaging should be routinely used to monitor CF lung disease. Future studies should focus on imaging protocol harmonisation both for computed tomography and for magnetic resonance imaging. The introduction of artificial intelligence imaging analysis may further revolutionise clinical practice by providing fast and reliable quantitative outcomes to assess disease status. To date, there is no evidence supporting the use of lung ultrasound to monitor CF lung disease.


Asunto(s)
Fibrosis Quística , Inteligencia Artificial , Conferencias de Consenso como Asunto , Fibrosis Quística/diagnóstico por imagen , Fibrosis Quística/terapia , Humanos , Imagen por Resonancia Magnética , Neumólogos , Radiólogos , Tomografía Computarizada por Rayos X
13.
Rheumatology (Oxford) ; 61(4): 1600-1609, 2022 04 11.
Artículo en Inglés | MEDLINE | ID: mdl-34320649

RESUMEN

OBJECTIVE: The aim of this study was to identify the main CT features that may help in distinguishing a progression of interstitial lung disease (ILD) secondary to SSc from COVID-19 pneumonia. METHODS: This multicentric study included 22 international readers grouped into a radiologist group (RADs) and a non-radiologist group (nRADs). A total of 99 patients, 52 with COVID-19 and 47 with SSc-ILD, were included in the study. RESULTS: Fibrosis inside focal ground-glass opacities (GGOs) in the upper lobes; fibrosis in the lower lobe GGOs; reticulations in lower lobes (especially if bilateral and symmetrical or associated with signs of fibrosis) were the CT features most frequently associated with SSc-ILD. The CT features most frequently associated with COVID- 19 pneumonia were: consolidation (CONS) in the lower lobes, CONS with peripheral (both central/peripheral or patchy distributions), anterior and posterior CONS and rounded-shaped GGOs in the lower lobes. After multivariate analysis, the presence of CONs in the lower lobes (P < 0.0001) and signs of fibrosis in GGOs in the lower lobes (P < 0.0001) remained independently associated with COVID-19 pneumonia and SSc-ILD, respectively. A predictive score was created that was positively associated with COVID-19 diagnosis (96.1% sensitivity and 83.3% specificity). CONCLUSION: CT diagnosis differentiating between COVID-19 pneumonia and SSc-ILD is possible through a combination of the proposed score and radiologic expertise. The presence of consolidation in the lower lobes may suggest COVID-19 pneumonia, while the presence of fibrosis inside GGOs may indicate SSc-ILD.


Asunto(s)
COVID-19 , Enfermedades Pulmonares Intersticiales , Esclerodermia Sistémica , COVID-19/complicaciones , COVID-19/diagnóstico por imagen , Prueba de COVID-19 , Fibrosis , Humanos , Pulmón/diagnóstico por imagen , Pulmón/patología , Enfermedades Pulmonares Intersticiales/complicaciones , Enfermedades Pulmonares Intersticiales/etiología , Esclerodermia Sistémica/complicaciones , Esclerodermia Sistémica/diagnóstico por imagen , Esclerodermia Sistémica/patología , Tomografía Computarizada por Rayos X
14.
J Bone Joint Surg Am ; 104(2): 189-200, 2022 01 19.
Artículo en Inglés | MEDLINE | ID: mdl-34780382

RESUMEN

➤: Bone marrow edema (BME) is a nonspecific but relevant finding, usually indicating the presence of an underlying pathology. ➤: The gold standard technique for detecting BME is magnetic resonance imaging (MRI), as it allows for a correct diagnosis to be made, which is extremely important given the heterogeneity of BME-related diseases. ➤: Depending on the severity of painful symptomatology and the MRI evidence, different treatment strategies can be followed: physical modalities, pharmacological options, and surgical therapy.


Asunto(s)
Enfermedades de la Médula Ósea , Edema , Imagen por Resonancia Magnética , Enfermedades de la Médula Ósea/diagnóstico por imagen , Enfermedades de la Médula Ósea/etiología , Enfermedades de la Médula Ósea/terapia , Diagnóstico Diferencial , Edema/diagnóstico por imagen , Edema/etiología , Edema/terapia , Humanos
15.
Dig Liver Dis ; 54(7): 911-917, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-34876355

RESUMEN

BACKGROUND AND AIMS: Circulating endothelial progenitor cells (EPC) predict tumor vascularization and disease progression, but limited information is available on their dynamics in hepatocellular carcinoma (HCC) undergoing systemic treatment. METHODS: We prospectively analyzed different populations of EPC in 16 patients with advanced HCC receiving sorafenib. Patients were studied before therapy (T0, n = 16) and after two (T2, n = 12) and eight weeks (T8, n = 8), using high-performance flow-cytometry. The tumor response at T8 was categorized as progressive disease (PD) or clinical benefit (CB, all other responses). RESULTS: At T0, higher levels of CD34+CD133+KDR+ and CD34+KDR+ were observed in patients with alpha-fetoprotein ≥400 ng/ml or non-viral liver disease, whereas CD34+CD133+KDR+ cells were virtually absent in patients with vascular invasion. CD34+KDR+ and CD34+CD133+KDR+ were directly correlated with platelet count. Frequencies of all populations of EPC declined in patients receiving sorafenib. Levels of CD34+CD133+ were higher at T0 in patients with CB compared to patients with PD. In patients belonging to the CB group CD34+KDR+ cells at T0 were directly correlated to platelet count. CONCLUSION: In patients with advanced HCC, EPC are directly correlated with platelet count, suggesting a common activation of selected bone marrow pathways. Levels of a CD34+KDR+ are higher at baseline in patients responding to sorafenib.


Asunto(s)
Carcinoma Hepatocelular , Células Progenitoras Endoteliales , Neoplasias Hepáticas , Antígenos CD34 , Biomarcadores/metabolismo , Células Progenitoras Endoteliales/metabolismo , Citometría de Flujo , Humanos , Neoplasias Hepáticas/tratamiento farmacológico , Sorafenib
16.
Radiol Med ; 126(11): 1434-1450, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34338948

RESUMEN

Whole-body magnetic resonance imaging (WB-MRI) is currently recommended for cancer screening in adult and paediatric subjects with cancer predisposition syndromes, representing a substantial aid for prolonging health and survival of these subjects with a high oncological risk. Additionally, the number of studies exploring the use of WB-MRI for cancer screening in asymptomatic subjects from the general population is growing. The primary aim of this review was to analyse the acquisition protocols found in the literature, in order to identify common sequences across published studies and to discuss the need of additional ones for specific populations. The secondary aim of this review was to provide a synthesis of current recommendations regarding the use of WB-MRI for cancer screening.


Asunto(s)
Detección Precoz del Cáncer/métodos , Imagen por Resonancia Magnética/métodos , Imagen de Cuerpo Entero , Humanos , Guías de Práctica Clínica como Asunto
18.
Eur J Radiol ; 139: 109716, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33866123

RESUMEN

Salivary gland tumours are rare, representing only 3% of all head and neck neoplasms, with the parotid gland being the most common site (80 %). The risk of malignancy is inversely proportional to the size of the gland: lesions arising in the sublingual or minor salivary glands are more likely to be malignant, whereas parotid gland neoplasms are mostly benign. Fine needle aspiration cytology and core needle biopsy are considered the most accurate modalities for the diagnosis of a salivary gland neoplasm; however, they are not always conclusive due to procedural sampling errors and for the presence of a cytological / histological overlap between benign and malignant tumours. Moreover, they cannot be easily performed for parotid deep portion localisation. The role of magnetic resonance imaging (MRI) is growing and advanced techniques (diffusion-weighted and dynamic contrast-enhanced perfusion-weighted imaging) can provide useful additional information for the assessment of salivary gland neoplasms. The aim of this review is to present the main MRI and clinical features of salivary gland tumours to improve their comprehensive evaluation and characterisation.


Asunto(s)
Neoplasias de la Parótida , Neoplasias de las Glándulas Salivales , Biopsia con Aguja Fina , Humanos , Imagen por Resonancia Magnética , Glándula Parótida , Neoplasias de las Glándulas Salivales/diagnóstico por imagen
19.
Int J Cardiol ; 330: 251-258, 2021 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-33535074

RESUMEN

BACKGROUND: Quantitative cardiovascular magnetic resonance T1-mapping is increasingly used for myocardial tissue characterization. However, the lack of standardization limits direct comparability between centers and wider roll-out for clinical use or trials. PURPOSE: To develop a quality assurance (QA) program assuring standardized T1 measurements for clinical use. METHODS: MR phantoms manufactured in 2013 were distributed, including ShMOLLI T1-mapping and reference T1 and T2 protocols. We first studied the T1 and T2 dependency on temperature and phantom aging using phantom datasets from a single site over 4 years. Based on this, we developed a multiparametric QA model, which was then applied to 78 scans from 28 other multi-national sites. RESULTS: T1 temperature sensitivity followed a second-order polynomial to baseline T1 values (R2 > 0.996). Some phantoms showed aging effects, where T1 drifted up to 49% over 40 months. The correlation model based on reference T1 and T2, developed on 1004 dedicated phantom scans, predicted ShMOLLI-T1 with high consistency (coefficient of variation 1.54%), and was robust to temperature variations and phantom aging. Using the 95% confidence interval of the correlation model residuals as the tolerance range, we analyzed 390 ShMOLLI T1-maps and confirmed accurate sequence deployment in 90%(70/78) of QA scans across 28 multiple centers, and categorized the rest with specific remedial actions. CONCLUSIONS: The proposed phantom QA for T1-mapping can assure correct method implementation and protocol adherence, and is robust to temperature variation and phantom aging. This QA program circumvents the need of frequent phantom replacements, and can be readily deployed in multicenter trials.


Asunto(s)
Cardiomiopatía Hipertrófica , Imagen por Resonancia Magnética , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Humanos , Fantasmas de Imagen , Sistema de Registros , Reproducibilidad de los Resultados
20.
Insights Imaging ; 12(1): 14, 2021 Feb 11.
Artículo en Inglés | MEDLINE | ID: mdl-33575851

RESUMEN

OBJECTIVE: To promote a better radiological interpretation of spine degeneration, a consistent standardization of the acquisition, interpretation and description of Magnetic Resonance Imaging (MRI) l findings. MATERIALS AND METHODS: In order to achieve this objective, a consensus among experts in imaging of degenerative spine disease (DSD) from Italian radiological societies (SIRM-Italian Society of Radiology, AINR-Italian Association of Neuroradiology) was achieved. The representatives of the Italian inter-societal working group examined the literature produced by European/American task forces on optimizing the study sequences, classification of degenerative disc changes, spondylo-arthrosis, osteochondrosis, synovial and ligament pathologies of the spinal column, and on canal and foraminal stenosis. The document-resulted from the consensus between experts-was then presented to the scientific societies of Neurosurgery (SINCH) and Orthopedics and Traumatology (SIOT) for their approval. RESULTS: This position paper presents a proposal for an optimized MRI protocol for studying DSD and provides a glossary of terms related to this pathology and indications on their use. The international terminological recommendations have been translated and adapted to the Italian language and clinical practice and clinical cases have been used to illustrate some of the main classifications. CONCLUSIONS: This revision of international DSD guidelines/recommendations and consensus made it possible to (1) update the nomenclature to international standards and (2) harmonize the MRI protocol and description of radiological findings, adapting both (1, 2) to the Italian context. With this position paper we intend to contribute to an improvement of the communication among doctors and between physicians and their patients as well as the quality of the radiological reports.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA