Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 115
Filtrar
1.
Abdom Radiol (NY) ; 2024 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-39068611

RESUMEN

PURPOSES: Low-grade oncocytic tumor (LOT) is a rare renal tumor that has emerged from the spectrum of eosinophilic/oncocytic renal tumors and poses a diagnostic challenge due to its similarity to chromophobe renal cell carcinoma (CHRCC) and renal oncocytoma (RO). The imaging features of this novel tumor entity have not yet been clearly described. The purpose of this study was to describe the imaging features of LOT with radiologic-pathologic correlation. METHODS: We conducted a retrospective observational study involving two expert centers. We identified 12 pathologically proven LOT with preoperative imaging available, including at least computed tomography (CT) or magnetic resonance imaging (MRI), from the past 12 years. Three experienced radiologists performed the imaging analysis independently. RESULTS: All tumors presented well-defined borders. Nine of the 12 LOT exhibited an early peripheral enhancement with complete or almost complete centripetal fill-in on nephrographic or delayed phases without any particular shape. Three showed a homogeneous contrast enhancement. Macroscopic fat and calcifications were not observed in any of the tumors. CONCLUSION: Early peripheral enhancement with complete or almost complete centripetal fill-in on nephrographic or delayed phases without any particular shape suggests a LOT diagnosis. Further analyses involving larger studies are needed to fully confirm these imaging characteristics. To date, a percutaneous biopsy should be performed before considering management.

2.
Fr J Urol ; 34(7-8): 102660, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38823486

RESUMEN

INTRODUCTION: The incidence of localized renal cell carcinoma (RCC) is on the rise among individuals aged 70 and older. While the gold standard for treatment remains surgical resection, some elderly and frail patients with comorbidities are not eligible for this procedure. In selected cases, percutaneous thermal ablation, such as cryotherapy, microwave and radiofrequency, offers less invasive options. General anesthesia is sometimes necessary for such treatments, but most of the procedures can be conducted using mild or deep conscious sedation. This approach is preferably recommended for small cT1a tumors situated at a distance from the renal hilum and/or ureter. Active surveillance remains an alternative in the case of small low grade RCC although it may induce anxiety in certain patients. Recent research has highlighted the potentials of stereotactic ablative body radiotherapy (SABR) as a noninvasive, well-tolerated, and effective treatment for small renal tumors. This narrative review aims to explore recent advances in SABR for localized RCC, including appropriate patient selection, treatment modalities and administration, as well as efficacy and tolerance assessment. MATERIAL AND METHODS: We conducted a literature review using the terms [kidney cancer], [renal cell carcinoma], [stereotactic radiotherapy], [SBRT], and [SABR] in the Medline, PubMed, and Embase databases, focusing on prospective and relevant retrospective studies published in English. RESULTS: Studies report local control rates ranging from 70% to 100% with SABR, highlighting its efficacy in treating RCC. The decline in glomerular filtration rate (GFR) is approximately -5 to -17mL/min over the years following SABR. Common toxicities are rare, primarily CTCAE grade 1, include fatigue, nausea, chest or back pain, diarrhea, or gastritis. CONCLUSION: Stereotactic ablative body radiotherapy (SABR) may be considered as a viable option for patients with localized RCC who are not suitable candidates for surgery with a high local control rate and a favorable safety profile. This approach should be discussed in a multidisciplinary meeting and results from ongoing clinical trials are awaited.


Asunto(s)
Carcinoma de Células Renales , Neoplasias Renales , Radiocirugia , Humanos , Carcinoma de Células Renales/radioterapia , Carcinoma de Células Renales/cirugía , Radiocirugia/métodos , Radiocirugia/efectos adversos , Neoplasias Renales/radioterapia , Neoplasias Renales/cirugía , Selección de Paciente , Resultado del Tratamiento
3.
Hepatology ; 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38652643

RESUMEN

BACKGROUND AND AIMS: Noninvasive tools assessing steatosis, such as ultrasonography-based 2D-attenuation imaging (ATI), are needed to tackle the worldwide burden of steatotic liver disease. This one-stage individual patient data (IPD) meta-analysis aimed to create an ATI-based steatosis grading system. APPROACH AND RESULTS: A systematic review (EMBASE + MEDLINE, 2018-2022) identified studies, including patients with histologically or magnetic resonance imaging proton-density fat fraction (MRI-PDFF)-verified ATI for grading steatosis (S0 to S3). One-stage IPD meta-analyses were conducted using generalized mixed models with a random study-specific intercept. Created ATI-based steatosis grading system (aS0 to aS3) was externally validated on a prospective cohort of patients with type 2 diabetes and metabolic dysfunction-associated steatotic liver disease (n=174, histologically and MRI-PDFF-verified steatosis). Eleven enrolled studies included 1374 patients, classified into S0, S1, S2, and S3 in 45.4%, 35.0%, 9.3%, and 10.3% of the cases. ATI was correlated with histological steatosis ( r = 0.60; 95% CI: 0.52, 0.67; p < 0.001) and MRI-PDFF ( r = 0.70; 95% CI: 0.66, 0.73; p < 0.001) but not with liver stiffness ( r = 0.03; 95% CI: -0.04, 0.11, p = 0.343). Steatosis grade was an independent factor associated with ATI (coefficient: 0.24; 95% CI: [0.22, 0.26]; p < 0.001). ATI marginal means within S0, S1, S2, and S3 subpopulations were 0.59 (95% CI: [0.58, 0.61]), 0.69 (95% CI [0.67, 0.71]), 0.78 (95% CI: [0.76, 0.81]), and 0.85 (95% CI: [0.83, 0.88]) dB/cm/MHz; all contrasts between grades were significant ( p < 0.0001). Three ATI thresholds were calibrated to create a new ATI-based steatosis grading system (aS0 to aS3, cutoffs: 0.66, 0.73, and 0.81 dB/cm/MHz). Its external validation showed Obuchowski measures of 0.84 ± 0.02 and 0.82 ± 0.02 with histologically based and MRI-PDFF-based references. CONCLUSIONS: ATI is a reliable, noninvasive marker of steatosis. This validated ATI-based steatosis grading system could be valuable in assessing patients with metabolic dysfunction-associated steatotic liver disease.

4.
Eur Radiol ; 34(10): 6435-6443, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38573340

RESUMEN

OBJECTIVES: Hysterosalpingography (HSG) is widely used for evaluating the fallopian tubes; however, controversies regarding the use of water- or oil-based iodine-based contrast media (CM) remain. The aim of this work was (1) to discuss reported pregnancy rates related to the CM type used, (2) to validate the used CM in published literature, (3) to discuss possible complications and side effects of CM in HSG, and (4) to develop guidelines on the use of oil-based CM in HSG. METHODS: A systematic literature search was conducted for original RCT studies or review/meta-analyses on using water-based and oil-based CM in HSG with fertility outcomes and complications. Nine randomized controlled trials (RCTs) and 10 reviews/meta-analyses were analyzed. Grading of the literature was performed based on the Oxford Centre for Evidence-Based Medicine (OCEBM) 2011 classification. RESULTS: An approximately 10% higher pregnancy rate is reported for oil-based CM. Side effects are rare, but oil-based CM have potentially more side effects on the maternal thyroid function and the peritoneum. CONCLUSIONS: 1. HSG with oil-based CM gives approximately 10% higher pregnancy rates. 2. External validity is limited, as in five of nine RCTs, the CM used is no longer on the market. 3. Oil-based CM have potentially more side effects on the maternal thyroid function and on the peritoneum. 4. Guideline: Maternal thyroid function should be tested before HSG with oil-based CM and monitored for 6 months after. CLINICAL RELEVANCE STATEMENT: Oil-based CM is associated with an approximately 10% higher chance of pregnancy compared to water-based CM after HSG. Although side effects are rare, higher iodine concentration and slower clearance of oil-based CM may induce maternal thyroid function disturbance and peritoneal inflammation and granuloma formation. KEY POINTS: • It is unknown which type of contrast medium, oil-based or water-based, is the optimal for HSG. • Oil-based contrast media give a 10% higher chance of pregnancy after HSG, compared to water-based contrast media. • From the safety perspective, oil-based CM can cause thyroid dysfunction and an intra-abdominal inflammatory response in the patient.


Asunto(s)
Medios de Contraste , Histerosalpingografía , Humanos , Medios de Contraste/efectos adversos , Histerosalpingografía/métodos , Femenino , Embarazo , Europa (Continente) , Guías de Práctica Clínica como Asunto , Yodo/efectos adversos , Índice de Embarazo
5.
Eur Urol Oncol ; 7(5): 1113-1122, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38493072

RESUMEN

BACKGROUND AND OBJECTIVE: Prostate multiparametric magnetic resonance imaging (MRI) shows high sensitivity for International Society of Urological Pathology grade group (GG) ≥2 cancers. Many artificial intelligence algorithms have shown promising results in diagnosing clinically significant prostate cancer on MRI. To assess a region-of-interest-based machine-learning algorithm aimed at characterising GG ≥2 prostate cancer on multiparametric MRI. METHODS: The lesions targeted at biopsy in the MRI-FIRST dataset were retrospectively delineated and assessed using a previously developed algorithm. The Prostate Imaging-Reporting and Data System version 2 (PI-RADSv2) score assigned prospectively before biopsy and the algorithm score calculated retrospectively in the regions of interest were compared for diagnosing GG ≥2 cancer, using the areas under the curve (AUCs), and sensitivities and specificities calculated with predefined thresholds (PIRADSv2 scores ≥3 and ≥4; algorithm scores yielding 90% sensitivity in the training database). Ten predefined biopsy strategies were assessed retrospectively. KEY FINDINGS AND LIMITATIONS: After excluding 19 patients, we analysed 232 patients imaged on 16 different scanners; 85 had GG ≥2 cancer at biopsy. At patient level, AUCs of the algorithm and PI-RADSv2 were 77% (95% confidence interval [CI]: 70-82) and 80% (CI: 74-85; p = 0.36), respectively. The algorithm's sensitivity and specificity were 86% (CI: 76-93) and 65% (CI: 54-73), respectively. PI-RADSv2 sensitivities and specificities were 95% (CI: 89-100) and 38% (CI: 26-47), and 89% (CI: 79-96) and 47% (CI: 35-57) for thresholds of ≥3 and ≥4, respectively. Using the PI-RADSv2 score to trigger a biopsy would have avoided 26-34% of biopsies while missing 5-11% of GG ≥2 cancers. Combining prostate-specific antigen density, the PI-RADSv2 and algorithm's scores would have avoided 44-47% of biopsies while missing 6-9% of GG ≥2 cancers. Limitations include the retrospective nature of the study and a lack of PI-RADS version 2.1 assessment. CONCLUSIONS AND CLINICAL IMPLICATIONS: The algorithm provided robust results in the multicentre multiscanner MRI-FIRST database and could help select patients for biopsy. PATIENT SUMMARY: An artificial intelligence-based algorithm aimed at diagnosing aggressive cancers on prostate magnetic resonance imaging showed results similar to expert human assessment in a prospectively acquired multicentre test database.


Asunto(s)
Algoritmos , Clasificación del Tumor , Neoplasias de la Próstata , Humanos , Masculino , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/diagnóstico por imagen , Estudios Retrospectivos , Anciano , Persona de Mediana Edad , Imágenes de Resonancia Magnética Multiparamétrica , Bases de Datos Factuales , Imagen por Resonancia Magnética/métodos , Sensibilidad y Especificidad
6.
J Hepatol ; 81(2): 195-206, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38548067

RESUMEN

BACKGROUND & AIMS: Non-invasive scores have been proposed to identify patients with fibrotic, metabolic dysfunction-associated steatohepatitis (MASH), who are at the highest risk of progression to complications of cirrhosis and may benefit from pharmacologic treatments. However, data in patients with type 2 diabetes (T2DM) are lacking. The aim of this multicenter prospective study was to perform a head-to-head comparison of FAST (FibroScan-aspartate aminotransferase [AST]), MAST (MRI-AST), MEFIB (magnetic resonance elastography [MRE] plus FIB-4), and FNI (fibrotic NASH index) for detecting fibrotic MASH in patients with T2DM. METHODS: A total of 330 outpatients with T2DM and biopsy-proven metabolic dysfunction-associated steatotic liver disease (MASLD) from the QUID-NASH study (NCT03634098), who underwent FibroScan, MRI-proton density fat fraction and MRE at the time of liver biopsy were studied. The main outcome was fibrotic MASH, defined as NAS ≥4 (with at least one point for each parameter) and fibrosis stage ≥2 (centrally reviewed). RESULTS: All data for score comparisons were available for 245 patients (median age 59 years, 65% male, median BMI 31 kg/m2; fibrotic MASH in 39%). FAST and MAST had similar accuracy (AUROCs 0.81 vs. 0.79, p = 0.41) but outperformed FNI (0.74; p = 0.01) and MEFIB (0.68; p <0.0001). When using original cut-offs, MAST outperformed FAST, MEFIB and FNI when comparing the percentage of correctly classified patients, in whom liver biopsy would be avoided (69% vs. 48%, 46%, 39%, respectively; p <0.001). When using cut-offs specific to our population, FAST outperformed FNI and MAST (56% vs. 40%, and 38%, respectively; p <0.001). CONCLUSION: Our findings show that FAST, MAST, MEFIB and FNI are accurate non-invasive tools to identify patients with T2DM and fibrotic MASH in secondary/tertiary diabetes clinics. Cut-offs adapted to the T2DM population should be considered. IMPACT AND IMPLICATIONS: Among patients with type 2 diabetes (T2DM), identifying those with metabolic dysfunction-associated steatohepatitis and significant fibrosis, who are the most at risk of developing clinical liver-related outcomes and who may benefit from pharmacologic treatments, is an unmet need. In this prospective multicenter study, we compared four non-invasive scores, three based on imaging (MRI or ultrasound technologies) and one on laboratory blood tests, for this purpose, using original and study-specific cut-offs. Our findings show that FAST, MAST, MEFIB and FNI are accurate non-invasive tools to identify patients with T2DM and fibrotic MASH in secondary/tertiary diabetes clinics. Cut-offs adapted to the T2DM population should be considered. TRIAL REGISTRATION NUMBER: NCT03634098.


Asunto(s)
Diabetes Mellitus Tipo 2 , Diagnóstico por Imagen de Elasticidad , Cirrosis Hepática , Imagen por Resonancia Magnética , Humanos , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/diagnóstico , Masculino , Persona de Mediana Edad , Femenino , Estudios Prospectivos , Diagnóstico por Imagen de Elasticidad/métodos , Cirrosis Hepática/diagnóstico , Cirrosis Hepática/etiología , Imagen por Resonancia Magnética/métodos , Anciano , Enfermedad del Hígado Graso no Alcohólico/complicaciones , Enfermedad del Hígado Graso no Alcohólico/diagnóstico , Biopsia/métodos , Hígado/patología , Hígado/diagnóstico por imagen , Aspartato Aminotransferasas/sangre
7.
Invest Radiol ; 59(8): 561-568, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38214557

RESUMEN

OBJECTIVES: Kidney diseases significantly impact individuals' quality of life and strongly reduce life expectancy. Glomeruli play a crucial role in kidney function. Current imaging techniques cannot visualize them due to their small size. Sensing ultrasound localization microscopy (sULM) has shown promising results for visualizing in vivo the glomeruli of human kidney grafts. This study aimed to evaluate the ability of sULM to visualize glomeruli in vivo in native human kidneys despite their depth and a shorter duration of ultrasound acquisition limited by the period of the patient's apnea. Sensing ultrasound localization microscopy parameters in native kidneys and kidney grafts and their consequence regarding glomeruli detection were also compared. MATERIALS AND METHODS: Exploration by sULM was conducted in 15 patients with native kidneys and 5 with kidney allografts. Glomeruli were counted using a normalized distance metric projected onto sULM density maps. The difference in the acquisition time, the kidney depth, and the frame rate between native kidneys and kidney grafts and their consequence regarding glomeruli detection were assessed. RESULTS: Glomerular visualization was achieved in 12 of 15 patients with native kidneys. It failed due to impossible breath-holding for 2 patients and a too-deep kidney for 1 patient. Sensing ultrasound localization microscopy found 16 glomeruli per square centimeter in the native kidneys (6-31) and 33 glomeruli per square centimeter in kidney transplant patients (18-55). CONCLUSIONS: This study demonstrated that sULM can visualize glomeruli in native human kidneys in vivo. The proposed method may have many hypothetical applications, including biomarker development, assisting biopsy, or potentially avoiding it. It establishes a framework for improving the detection of local microstructural pathology, influencing the evaluation of allografts, and facilitating disease monitoring in the native kidney.


Asunto(s)
Enfermedades Renales , Microscopía , Ultrasonografía , Humanos , Masculino , Adulto , Persona de Mediana Edad , Anciano , Ultrasonografía/métodos , Trasplante de Riñón , Medios de Contraste , Aloinjertos/diagnóstico por imagen , Microscopía/métodos , Riñón/diagnóstico por imagen
8.
Ultraschall Med ; 45(1): 36-46, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37748503

RESUMEN

Dynamic contrast-enhanced ultrasound (DCE-US) is a technique to quantify tissue perfusion based on phase-specific enhancement after the injection of microbubble contrast agents for diagnostic ultrasound. The guidelines of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) published in 2004 and updated in 2008, 2011, and 2020 focused on the use of contrast-enhanced ultrasound (CEUS), including essential technical requirements, training, investigational procedures and steps, guidance regarding image interpretation, established and recommended clinical indications, and safety considerations. However, the quantification of phase-specific enhancement patterns acquired with ultrasound contrast agents (UCAs) is not discussed here. The purpose of this EFSUMB Technical Review is to further establish a basis for the standardization of DCE-US focusing on treatment monitoring in oncology. It provides some recommendations and descriptions as to how to quantify dynamic ultrasound contrast enhancement, and technical explanations for the analysis of time-intensity curves (TICs). This update of the 2012 EFSUMB introduction to DCE-US includes clinical aspects for data collection, analysis, and interpretation that have emerged from recent studies. The current study not only aims to support future work in this research field but also to facilitate a transition to clinical routine use of DCE-US.


Asunto(s)
Medios de Contraste , Neoplasias , Humanos , Ultrasonografía/métodos , Perfusión
9.
Eur Radiol ; 34(4): 2512-2523, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37823923

RESUMEN

The pharmacokinetics of contrast media (CM) will determine how long safe waiting intervals between successive CT or MRI examinations should be. The Contrast Media Safety Committee has reviewed the data on pharmacokinetics of contrast media to suggest safe waiting intervals between successive contrast-enhanced imaging studies in relation to the renal function of the patient. CLINICAL RELEVANCE STATEMENT: Consider a waiting time between elective contrast-enhanced CT and (coronary) angiography with successive iodine-based contrast media administrations in patients with normal renal function (eGFR > 60 mL/min/1.73 m2) of optimally 12 h (near complete clearance of the previously administered iodine-based contrast media) and minimally 4 h (if clinical indication requires rapid follow-up). KEY POINTS: • Pharmacokinetics of contrast media will guide safe waiting times between successive administrations. • Safe waiting times increase with increasing renal insufficiency. • Iodine-based contrast media influence MRI signal intensities and gadolinium-based contrast agents influence CT attenuation.


Asunto(s)
Yodo , Insuficiencia Renal , Humanos , Medios de Contraste/efectos adversos , Listas de Espera , Angiografía Coronaria
11.
Transplantation ; 108(2): 567-578, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-37726878

RESUMEN

BACKGROUND: The overall cancer risk increases in transplant patients, including in kidney allografts. This study aimed to analyze the outcome of patients with kidney allograft malignant tumors who underwent percutaneous thermal ablation. METHODS: We included 26 renal allograft tumors, including 7 clear-cell renal cell carcinoma (RCCs), 16 papillary RCCs, 1 clear-cell papillary RCC, and 2 tubulocystic RCCs, treated in 19 ablation sessions. Outcomes of thermal ablation therapy were assessed, including technical success, adverse events, local tumor progression, development of metastases, survival after thermal ablation, and changes in renal function. RESULTS: Success rate was achieved in all ablation sessions (primary success rate: 96%; secondary success rate: 100%). No adverse events were observed in grades 3, 4, or 5. The median follow-up period was of 34 mo (15-69 mo). Two patients died during follow-up from a cause independent of renal cancer. The median decrease in estimated glomerular filtration rate 1 y after procedure was -4 (interquartile range, -7 to 0) mL/min/1.73 m 2 . One patient returned to dialysis within the year of the procedure. CONCLUSIONS: Percutaneous thermal ablation shows convincing results for treating malignant renal graft tumors and should be a useful treatment option. The shorter hospitalization time, the advantage of avoiding a potentially challenging dissection of the transplant, and the excellent preservation of allograft function appear encouraging to extend this indication.


Asunto(s)
Carcinoma de Células Renales , Ablación por Catéter , Neoplasias Renales , Trasplante de Riñón , Humanos , Trasplante de Riñón/efectos adversos , Resultado del Tratamiento , Riñón/patología , Neoplasias Renales/patología , Aloinjertos/patología , Estudios Retrospectivos , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
12.
Eur Radiol ; 2023 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-38092951

RESUMEN

OBJECTIVES: It is uncertain whether modern iodine-based or gadolinium-based contrast media (CM) administration can lead to increased symptoms in patients with myasthenia gravis. METHODS: A systematic search in Medline was conducted for studies describing the symptomatology of myasthenia gravis patients before and after receiving intravenous (IV) CM and having a matched control group of myasthenia gravis patients who did not receive IV CM. RESULTS: Three retrospective studies were selected with a total of 374 myasthenia gravis patients who received iodine-based CM and a total of 313 myasthenia gravis patients who underwent unenhanced CT and served as controls. Pooling of the data from the three retrospective studies showed that in 23 of 374 patients, increased symptoms after iodine-based CM administration were described (6.1%). Increased symptomatology also occurred in 11 of 313 patients after unenhanced CT (3.5%). When looking more deeply into the data of the three studies, conflicting results were found, as two articles did not find any relationship between CM and myasthenia gravis symptoms. The remaining study only found a significant increase in symptomatology within 1 day after CT scanning: seven patients (6.3%) in the contrast-enhanced CT group and one patient (0.6%) in the unenhanced CT group (p = 0.01). CONCLUSIONS: There is limited evidence on the relationship between CM and myasthenia gravis symptoms. In the vast majority of myasthenia gravis patients, CM are safe. Probably, in less than 5% of the patients, iodine-based CM administration may lead to increased severity of the symptoms within the first 24 h after administration. CLINICAL RELEVANCE STATEMENT: Be aware that intravenous administration of iodine-based contrast media can lead to an increase of symptoms in patients with myasthenia gravis within the first 24 h. This can probably happen in less than 5% of the patients. KEY POINTS: • It is unclear whether modern contrast media can lead to increased symptoms in myasthenia gravis patients after intravenous administration. • There seems to be a small risk of increased myasthenia gravis symptoms within 24 h after intravenous administration of iodine-based contrast media, probably in less than 5% of the administrations. • Gadolinium-based contrast media are safe for patients with myasthenia gravis.

13.
Eur Radiol ; 2023 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-38060004

RESUMEN

The Contrast Media Safety Committee of the European Society of Urogenital Radiology has, together with the Preanalytical Phase Working Group of the EFLM Science Committee, reviewed the literature and updated its recommendations to increase awareness and provide insight into these interferences. CLINICAL RELEVANCE STATEMENT: Contrast Media may interfere with clinical laboratory tests. Awareness of potential interference may prevent unwanted misdiagnosis. KEY POINTS: • Contrast Media may interfere with clinical laboratory tests; therefore awareness of potential interference may prevent unwanted misdiagnosis. • Clinical Laboratory tests should be performed prior to radiological imaging with contrast media or alternatively, blood or urine collection should be delayed, depending on kidney function.

14.
Artículo en Inglés | MEDLINE | ID: mdl-38072287

RESUMEN

BACKGROUND & AIMS: Similarly to the controlled attenuation parameter (CAP), the ultrasound-based attenuation imaging (ATI) can quantify hepatic steatosis. We prospectively compared the performance of ATI and CAP for the diagnosis of hepatic steatosis in patients with type 2 diabetes and nonalcoholic fatty liver disease using histology and magnetic resonance imaging-proton density fat fraction (MRI-PDFF) as references. METHODS: Patients underwent ATI and CAP measurement, MRI, and biopsy on the same day. Steatosis was classified as S0, S1, S2, and S3 on histology (<5%, 5%-33%, 33%-66%, and >66%, respectively) while the thresholds of 6.4%, 17.4%, and 22.1%, respectively, were used for MRI-PDFF. The area under the curve (AUC) of ATI and CAP was compared using a DeLong test. RESULTS: Steatosis could be evaluated in 191 and 187 patients with MRI-PDFF and liver biopsy, respectively. For MRI-PDFF steatosis, the AUC of ATI and CAP were 0.86 (95% confidence interval [CI], 0.81-0.91) vs 0.69 (95% CI, 0.62-0.75) for S0 vs S1-S3 (P = .02) and 0.71 (95% CI, 0.64-0.77) vs 0.69 (95% CI, 0.61-0.75) for S0-S1 vs S2-S3 (P = .60), respectively. For histological steatosis, the AUC of ATI and CAP were 0.92 (95% CI, 0.87-0.95) vs 0.95 (95% CI, 0.91-0.98) for S0 vs S1-S3 (P = .64) and 0.79 (95% CI, 0.72-0.84) vs 0.76 (95% CI, 0.69-0.82) for S0-S1 vs S2-S3 (P = .61), respectively. CONCLUSION: ATI may be used as an alternative to CAP for the diagnosis and quantification of steatosis, in patients with type 2 diabetes and nonalcoholic fatty liver disease.

15.
Cancers (Basel) ; 15(19)2023 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-37835403

RESUMEN

It is time for a change. CEUS is an established method that should be much more actively included in renal cyst monitoring strategies. This review compares the accuracies, strengths, and weaknesses of CEUS, CECT, and MRI in the classification of renal cysts. In order to avoid overstaging by CEUS, a further differentiation of classes IIF, III, and IV is required. A further development in the refinement of the CEUS-Bosniak classification aims to integrate CEUS more closely into the monitoring of renal cysts and to develop new and complex monitoring algorithms.

16.
Eur Radiol ; 33(12): 8703-8714, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37405502

RESUMEN

OBJECTIVES: Contrast enhancement by MRI done early after cryoablation for renal malignancies may suggest residual tumor (RT). However, we have observed MRI enhancement within 48 h of cryoablation in patients who had no contrast enhancement 6 weeks later. Our purpose was to identify features of 48-h contrast enhancement in patients without RT. METHODS: This single-center retrospective study included consecutive patients who underwent percutaneous cryoablation of renal malignancies in 2013-2020, exhibited cryoablation-zone MRI contrast enhancement 48 h later, and had available 6-week MRI scans. Persistent or growing CE at 6 weeks vs. 48 h was classified as RT. A washout index was calculated for each 48-h MRI, and its performance for predicting RT was assessed by receiver operating characteristic curve analysis. RESULTS: We included 60 patients with 72 cryoablation procedures and 83 cryoablation zones exhibiting 48-h contrast enhancement; mean age was 66 ± 17 years. Clear-cell renal cell carcinoma accounted for 95% of tumors. Of the 83 48-h enhancement zones, RT was observed in eight while 75 were benign. The 48-h enhancement was consistently visible at the arterial phase. Washout was significantly associated with RT (p < 0.001) and gradually increasing contrast enhancement with benignity (p < 0.009). A washout index below - 1.1 predicted RT with 88% sensitivity and 84% specificity. CONCLUSION: MRI contrast enhancement 48 h after cryoablation of renal malignancies was usually benign. Washout was associated with residual tumor, with a washout index value below - 1.1 exhibiting good performance in predicting residual tumor. These findings may help to guide decisions about repeat cryoablation. CLINICAL RELEVANCE STATEMENT: Magnetic resonance imaging contrast enhancement 48 h after cryoablation of renal malignancies rarely indicates residual tumor, which is characterized by washout with a washout index lower than - 1.1. KEY POINTS: • Contrast enhancement at the arterial phase of magnetic resonance imaging done 48 h after cryoablation of a renal malignancy is usually benign. • Residual tumor manifesting as contrast enhancement at the arterial phase is characterized by subsequent marked washout. • A washout index below - 1.1 has 88% sensitivity and 84% specificity for residual tumor.


Asunto(s)
Carcinoma de Células Renales , Criocirugía , Neoplasias Renales , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Carcinoma de Células Renales/diagnóstico por imagen , Carcinoma de Células Renales/cirugía , Criocirugía/métodos , Estudios Retrospectivos , Neoplasia Residual , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/cirugía , Neoplasias Renales/patología , Imagen por Resonancia Magnética/métodos , Medios de Contraste
17.
Bull Cancer ; 2023 May 09.
Artículo en Francés | MEDLINE | ID: mdl-37169604

RESUMEN

Managing a malignant renal tumor requires, first of all, a reflection on the necessity of its treatment. It must consider the renal function, altered at the time of diagnosis in 50% of cases. The treatment method chosen depends on many factors, in particular, the predicted residual renal function, the risk of chronic kidney disease, the need for temporary or long-term dialysis, and overall long-term survival. Other factors include the size, position, and number of tumors and a hereditary tumor background. When a renal-sparing management alternative is available, total nephrectomy should no longer be performed in patients with small malignant renal masses (cT1a). This may consist of surgery (partial nephrectomy or lumpectomy), percutaneous thermo-ablation (by radiofrequency, microwave, or cryotherapy). In patients with limited life expectancy, imaging-based surveillance may be proposed to suggest treatment in case of local progression. Good coordination between urologist, radiologist, nephrologist, and sometimes radiotherapist should allow optimal management of patients with a malignant renal tumor with or without underlying renal failure.

18.
EBioMedicine ; 91: 104578, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37086650

RESUMEN

BACKGROUND: Estimation of glomerular function is necessary to diagnose kidney diseases. However, the study of glomeruli in the clinic is currently done indirectly through urine and blood tests. A recent imaging technique called Ultrasound Localization Microscopy (ULM) has appeared. It is based on the ability to record continuous movements of individual microbubbles in the bloodstream. Although ULM improved the resolution of vascular imaging up to tenfold, the imaging of the smallest vessels had yet to be reported. METHODS: We acquired ultrasound sequences from living humans and rats and then applied filters to divide the data set into slow-moving and fast-moving microbubbles. We performed a double tracking to highlight and characterize populations of microbubbles with singular behaviors. We decided to call this technique "sensing ULM" (sULM). We used post-mortem micro-CT for side-by-side confirmation in rats. FINDINGS: In this study, we report the observation of microbubbles flowing in the glomeruli in living humans and rats. We present a set of analysis tools to extract quantitative information from individual microbubbles, such as remanence time or normalized distance. INTERPRETATION: As glomeruli play a key role in kidney function, it would be possible that their observation yields a deeper understanding of the kidney. It could also be a tool to diagnose kidney diseases in patients. More generally, it will bring imaging capabilities closer to the functional units of organs, which is a key to understand most diseases, such as cancer, diabetes, or kidney failures. FUNDING: This study was funded by the European Research Council under the European Union Horizon H2020 program (ERC Consolidator grant agreement No 772786-ResolveStroke).


Asunto(s)
Enfermedades Renales , Microscopía , Humanos , Ratas , Animales , Microscopía/métodos , Ultrasonografía/métodos , Glomérulos Renales/diagnóstico por imagen , Riñón/diagnóstico por imagen , Medios de Contraste
19.
Artículo en Inglés | MEDLINE | ID: mdl-37022223

RESUMEN

In recent years, ultrasensitive Pulsed-Wave Doppler (uPWD) ultrasound (US) has emerged as an alternative imaging approach for microcirculation imaging and as a complementary tool to other imaging modalities, such as positron emission tomography (PET). uPWD is based on the acquisition of a large set of highly spatiotemporally coherent frames, which allows high-quality images of a wide field of view to be obtained. In addition, these acquired frames allow calculation of the resistivity index (RI) of the pulsatile flow detected over the entire field of view, which is of great interest to clinicians, for example, in monitoring the transplanted kidney course. This work aims to develop and evaluate a method to automatically obtain an RI map of the kidney based on the uPWD approach. The effect of time gain compensation (TGC) on the visualization of vascularization and aliasing on the blood flow frequency response, was also assessed. A pilot study conducted in patients referred for renal transplant Doppler examination showed that the proposed method provided relative errors of about 15% for RI measurements with respect to conventional pulsed-wave (PW) Doppler.

20.
Med Ultrason ; 25(3): 312-324, 2023 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-36996384

RESUMEN

In this series of papers on comments and illustrations of the World Federation for Medicine and Biology (WFUMB) guidelines on contrast enhanced ultrasound (CEUS) the topics of bacterial infections are discussed. Improved detection and characterization of common focal liver lesions (FLL) are the main topics of these guidelines but detailed and illustrating information is missing. The focus in this paper on infectious (bacterial) focal liver lesions is on their appearance on B-mode and Doppler ultrasound and CEUS features. Knowledge of these data should help to raise awareness of these rarer findings, to think of these clinical pictures in the corresponding clinical situation, to interpret the ultrasound images correctly and thus to initiate the appropriate diagnostic and therapeutic steps in time.


Asunto(s)
Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/patología , Medios de Contraste , Hígado/diagnóstico por imagen , Hígado/patología , Ultrasonografía/métodos , Angiografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA