Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros




Base de datos
Asunto de la revista
Intervalo de año de publicación
1.
Med Ultrason ; 26(1): 21-25, 2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-38150697

RESUMEN

AIMS: Ultrasound (US) is an essential diagnostic and educational tool in medical practice, and its effective implementation into medical curricula is critical. This study aimed to compare the efficacy of two disparate educational approaches-an optional semester course and a specifically curated intensive workshop-on the learning curve of medical students in abdominal ultrasonography. MATERIAL AND METHODS: Engaging fourth and fifth-year medical students, this study, incorporated both theoretical and practical elements of US, providing participants with hands-on experience and evaluative assessments pre- and post-training. Students were segregated into two groups: one experienced a 14-hour optional semester course and the other a 6-hour intensive workshop, both yielding distinct teaching methodologies yet aspiring for synonymous educational outcomes. RESULTS: Involving a total of 93 participants, findings elucidated that regardless of the educational method employed, post-training identification of US structures exhibited a significant enhancement compared to pre-training. Interestingly, no substantial disparities were discerned between the two educational approaches nor gender-based differences in learning outcomes. CONCLUSIONS: This investigation provides pivotal insights into the versatile utility of different educational strategies in abdominal US training for medical students, affirming that varied pedagogical methods can achieve comparable augmentations in student proficiency. Further research is paramount to ascertain the optimal integration of US education into medicalcurricula, considering aspects such as duration, depth, and mode of delivery.


Asunto(s)
Educación de Pregrado en Medicina , Estudiantes de Medicina , Humanos , Curva de Aprendizaje , Evaluación Educacional/métodos , Ultrasonografía , Curriculum , Educación de Pregrado en Medicina/métodos
2.
Diagnostics (Basel) ; 12(6)2022 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-35741261

RESUMEN

Liver fibrosis is the most significant prognostic factor in chronic liver disease (CLD). Clinical practice guidelines recommend the use of non-invasive techniques, such as two-dimensional shear-wave elastography (2D-SWE), to assess liver stiffness as a marker of fibrosis. Several other factors influence liver stiffness in addition to liver fibrosis. It is presumed that changes due to necro-inflammation modify the propagation of shear waves (dispersion). Therefore, new imaging techniques that investigate the dispersion properties of shear waves have been developed, which can serve as an indirect method of measuring liver viscosity (Vi PLUS). Defining the reference values in healthy subjects among different age groups and genders and analyzing the factors that influence these values is essential. However, published data on liver viscosity are still limited. This is the first study that aimed to assess the normal range of liver viscosity values in subjects with healthy livers and analyze the factors that influence them. One hundred and thirty-one consecutive subjects with healthy livers were enrolled in this prospective study. The results showed that Vi PLUS is a highly feasible method. Liver stiffness, age and BMI influenced the liver viscosity values. The mean liver viscosity by Vi PLUS in subjects with healthy livers was 1.59 Pa·s.

3.
J Clin Med ; 10(11)2021 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-34204032

RESUMEN

(1) Background: Patients suffering from the novel coronavirus 2019 (COVID-19) disease could experience several extra-pulmonary involvements, including cardiovascular complications and liver injury. This study aims to evaluate the presence of cardiac and liver alterations in patients with post-acute COVID-19 syndrome using transthoracic echocardiography (TTE) and liver elastography (LE). (2) Methods: A total of 97 subjects recovering from COVID-19, attending the hospital's specialized outpatient clinic for persisting symptoms at 3 to 11 weeks after the acute illness, were included in this study. They all had a basal COVID-19 assessment, and subsequently, a clinical evaluation, laboratory tests, TTE, and LE. (3) Results: considering the presence of pulmonary injury during COVID-19, patients were divided into two groups. Although none of them had altered systolic function, we evidenced pulmonary hypertension, diastolic dysfunction, increased liver stiffness, viscosity, and steatosis in around one-third of the patients, with significantly higher values in subjects with pulmonary injury compared to those without. (4) Conclusion: persisting symptoms characterizing the post-acute COVID-19 syndrome could be explained by residual cardiac and hepatic lesions, which were worse in more severe COVID-19 forms. These patients may be at risk of developing liver fibrosis and cardiac alterations and should be investigated in the first 12 weeks after the onset of the infection.

4.
Diagnostics (Basel) ; 11(5)2021 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-33926073

RESUMEN

Non-alcoholic fatty liver disease (NAFLD) is the most common chronic liver disease worldwide. This study aimed to evaluate the performance of four ultrasound-based techniques for the non-invasive multiparametric (MPUS) assessment of liver fibrosis (LF), steatosis (HS), and inflammation in patients with NAFLD. We included 215 consecutive adult patients with NAFLD (mean age: 54.9 ± 11.7; 54.5% were male), in whom LF, HS, and viscosity were evaluated in the same session using four new ultrasound-based techniques embedded on the Aixplorer MACH 30 system: ShearWave Elastography (2D-SWE.PLUS), Sound Speed Plane-wave UltraSound (SSp.PLUS), Attenuation Plane-wave UltraSound (Att.PLUS), and Viscosity Plane-wave UltraSound (Vi.PLUS). Transient Elastography (TE) with Controlled Attenuation Parameter (CAP) (FibroScan) were considered as control. All elastographic measurements were performed according to guidelines. Valid liver stiffness measurements (LSM) were obtained in 98.6% of patients by TE, in 95.8% of patients by 2D-SWE.PLUS/Vi.PLUS, and in 98.1% of patients by Att.PLUS/SSp.PLUS, respectively. Therefore, 204 subjects were included in the final analysis. A strong correlation between LSMs by 2D-SWE.PLUS and TE (r = 0.89) was found. The best 2D-SWE.PLUS cut-off value for the presence of significant fibrosis (F ≥ 2) was 7 kPa. Regarding steatosis, SSp.PLUS correlated better than Att.PLUS with CAP values: (r = -0.74) vs. (r = 0.45). The best SSp.PLUS cut-off value for predicting the presence of significant steatosis was 1524 m/s. The multivariate regression analysis showed that Vi.PLUS values were associated with BMI and LSM by 2D-SWE.PLUS. In conclusion, MPUS was useful for assessing fibrosis, steatosis, and inflammation in a single examination in patients with NAFLD.

5.
Ultrasound Med Biol ; 47(7): 1692-1703, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33832824

RESUMEN

The goal of this study was to evaluate the performance of two new ultrasound-based techniques (ShearWave PLUS elastography [2-D-SWE PLUS], SSp PLUS Imaging [SSp PLUS]) implemented on the Aixplorer Mach 30 ultrasound system (Supersonic Imagine, Aix-en-Provence, France) for the non-invasive assessment of liver steatosis and fibrosis, using transient elastography (TE) with the controlled attenuation parameter (CAP) as reference. This monocentric cross-sectional study included 133 consecutive adult patients with chronic hepatopathies. Liver stiffness and steatosis were evaluated in the same session using the techniques mentioned above. An excellent correlation was observed between liver stiffness measurements obtained with 2-D-SWE PLUS and TE (r = 0.92, p < 0.0001). The best cutoff value of 2-D-SWE PLUS for predicting F≥2 was 6.8 kPa; for F≥3, 8.4 kPa; and for F4, 11 kPa. With respect to steatosis evaluation, a strong negative correlation between CAP and SSp PLUS values (r = -0.70, p < 0.0001) was obtained. The best SSp PLUS cutoff value for predicting steatosis was 1537 m/s.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/métodos , Hígado Graso/diagnóstico por imagen , Cirrosis Hepática/diagnóstico por imagen , Programas Informáticos , Adulto , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Ultrasonografía/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA