1.
J Oral Implantol ; 2024 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-38867372

RESUMEN

INTRODUCTION: Broken screw removal from the implant connection is a common but challenging process. Several proposed methods and technical solutions may result in unsuccessful removal; thus, a novel, more conservative, risk-free method is proposed as a first attempt. DESCRIPTION OF THE CASE: The proposal is to use a silicon restoration holder to be twisted counterclockwise on the dried surface of the broken fragment inside the implant connection. This method, within the limitations of a minimal case series, yielded 100% results; however, despite previous attempts with less con- servative techniques, this approach showed no efficacy. CONCLUSION: This article aims to promote the use of silicon restoration holders as a minimally invasive first attempt at broken screw retrieval treatment before considering other options.