Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
Eur J Cardiothorac Surg ; 66(1)2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38964837

RESUMEN

Pectus defects are a group of congenital conditions found in approximately 1 in 250 people, where the sternum is depressed back towards the spine (excavatum), protrudes forwards (carinatum) or more rarely is a mixture of both (arcuatum or mixed defects). For the majority of patients, it is well tolerated, but some patients are affected psychologically, physiologically or both. The deformity becomes apparent at a young age due to the growth of the ribs and the cartilage that links them to the sternum. The majority of defects are mild and are well tolerated, i.e. they do not affect activity and do not cause psychological harm. However, some young people develop lower self-esteem and depression, causing them to withdraw from activities (such as swimming, dancing) and from interactions that might 'expose' them (such as sleepovers, dating, going to the beach and wearing fashionable clothes). This psychological harm occurs at a crucial time during their physical and social development. A small number of patients have more extreme depression of their sternum that impedes their physiological reserve, which can occur when engaging in strenuous exercise (such as running) but can also limit moderate activity such as walking and climbing stairs. The effects can be so extreme that symptoms occur at rest or cause life-threatening compression of the major blood vessels and organs. The group of patients with physiological impairment usually also suffer from low self-esteem and depression. This paper summarizes the current evidence for the different treatment strategies for this condition, including supportive care, psychological support and non-surgical techniques including bracing and vacuum bell therapy. We also consider surgical techniques including the Ravitch procedure, the Nuss procedure (minimally invasive repair of pectus excavatum), pectus implants and other rare procedures such as Pectus Up. For the majority of patients, supportive care is sufficient, but for a minority, a combination of the other techniques may be considered. This paper also outlines best practice guidance for the delivery of such therapies, including standardized assessment, consent to treatment, audit, quality assurance and long-term support. All the interventions have risks and benefits that the patient, parents and clinicians need to carefully consider and discuss when deciding on the most appropriate course. We hope this evidence review of 'Best Practice for Pectus' will make a significant contribution to those considerations and help all involved, from patients to national policy makers, to deliver the best possible care.


Asunto(s)
Pectus Carinatum , Humanos , Pectus Carinatum/terapia , Tórax en Embudo/cirugía , Tórax en Embudo/terapia , Esternón/anomalías , Consenso
2.
J Phys Condens Matter ; 36(36)2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38759676

RESUMEN

All-optical schemes for switching magnetization offer a pathway towards the creation of more advanced data-storage technologies, both in terms of recording speed and energy-efficiency. It has previously been shown that picosecond-long optical pulses with central frequencies ranging between 12 and 30 THz are capable of driving magnetic switching in yttrium-iron-garnet films, provided that the excitation frequency matches the characteristic frequency of longitudinal optical phonons. Here, we explore how the phononic mechanism of magnetic switching in three distinct ferrimagnetic iron-garnet films evolves at optical frequencies below 10 THz, within the so-called terahertz gap. We find that at long wavelengths the magnetic switching rather correlates with phonon modes associated with the substrate. Our results show that the process of phononic switching of magnetization, previously discovered in the mid- to far-infrared spectral range, becomes much more complex at frequencies within the terahertz gap.

3.
IEEE J Transl Eng Health Med ; 12: 204-214, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38088989

RESUMEN

Our study was designed to develop a customisable, wearable, and comfortable medical device - the text so-called "MyPAD" that monitors the fullness of the bladder, triggering an alarm indicating the need to void, in order to prevent badwetting - i.e., treating Nocturnal Enuresis (NE) at the text pre-void stage using miniaturised mechatronics with Artificial Intelligence (AI). The developed features include: multiple bespoke ultrasound (US) probes for sensing, a bespoke electronic device housing custom US electronics for signal processing, a bedside alarm box for processing the echoed pulses and generating alarms, and a phantom to mimic the human body. The validation of the system is conducted on the text tissue-mimicking phantom and volunteers using Bidirectional Long Short-Term Memory Recurrent Neural Networks (Bi-LSTM-RNN) and Reinforcement Learning (RL). A Se value of 99% and a Sp value of 99.5% with an overall accuracy rate of 99.3% are observed. The obtained results demonstrate successful empirical evidence for the viability of the device, both in monitoring bladder expansion to determine voiding need and in reinforcing the continuous learning and customisation of the device for bladder control through consecutive uses. Clinical impact: MyPAD will treat the NE better and efficiently against other techniques currently used (e.g., post-void alarms) and will i) replace those techniques quickly considering sufferers' condition while being treated by other approaches, and ii) enable children to gain control of incontinence over time and consistently have dry nights. Category: Early/Pre-Clinical Research.


Asunto(s)
Enuresis Nocturna , Niño , Humanos , Enuresis Nocturna/terapia , Inteligencia Artificial , Vejiga Urinaria , Micción , Redes Neurales de la Computación
4.
Nano Lett ; 22(23): 9773-9780, 2022 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-36321690

RESUMEN

Magnetic memory combining plasmonics and magnetism is poised to dramatically increase the bit density and energy efficiency of light-assisted ultrafast magnetic storage, thanks to nanoplasmon-driven enhancement and confinement of light. Here we devise a new path for that, simultaneously enabling light-driven bit downscaling, reduction of the required energy for magnetic memory writing, and a subtle control over the degree of demagnetization in a magnetophotonic surface crystal. It features a regular array of truncated-nanocone-shaped Au-TbCo antennas showing both localized plasmon and surface lattice resonance modes. The ultrafast magnetization dynamics of the nanoantennas show a 3-fold resonant enhancement of the demagnetization efficiency. The degree of demagnetization is further tuned by activating surface lattice modes. This reveals a platform where ultrafast demagnetization is localized at the nanoscale and its extent can be controlled at will, rendering it multistate and potentially opening up so-far-unforeseen nanomagnetic neuromorphic-like systems operating at femtosecond time scales controlled by light.

5.
Med Biol Eng Comput ; 58(5): 943-965, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32090271

RESUMEN

Post-void alarm systems to monitor bedwetting in nocturnal enuresis (NE) have been deemed unsatisfactory. The aim of this study is to develop a safe, comfortable and non-invasive pre-void wearable alarm and associated technologies using advanced mechatronics. Each stage of development includes patient and public involvement and engagement (PPI). The early stages of the development involved children with and without NE (and parents) who were tested at a hospital under the supervision of physicians, radiologists, psychologists, and nurses. The readings of the wearable device were simultaneously compared with B-mode images and measurements, acquired from a conventional ultrasound device, and were found to correlate highly. The results showed that determining imminent voiding need is viable using non-invasive sensors. Following on from "proof of concept," a bespoke advanced mechatronics device has been developed. The device houses custom electronics, an ultrasound system, intelligent software, a user-friendly smartphone application, bedside alarm box, and a dedicated undergarment, along with a self-adhesive gel pad-designed to keep the MEMS sensors aligned with the abdomen. Testing of the device with phantoms and volunteers has been successful in determining bladder volume and associated voiding need. Five miniaturised, and therefore more ergonomic, versions of the device are being developed, with an enabled connection to the cloud platform for location independent control and monitoring. Thereafter, the enhanced device will be tested with children with NE at their homes for 14 weeks, to gain feedback relating to wearability and data collection involving the cloud platform. Graphical Abstract Design of the MyPAD advanced mechatronics system.


Asunto(s)
Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Enuresis Nocturna/diagnóstico , Vejiga Urinaria/fisiología , Dispositivos Electrónicos Vestibles , Niño , Diseño de Equipo , Femenino , Humanos , Masculino , Sistemas Microelectromecánicos , Teléfono Inteligente , Ultrasonografía , Vejiga Urinaria/diagnóstico por imagen
6.
Pharmaceut Med ; 34(1): 39-48, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31970684

RESUMEN

BACKGROUND: To date, no pre-void wearable alarm exists to treat nocturnal enuresis (NE)-night-time bedwetting, and children with NE and their families are disappointed in relation to the post-void moisture alarms and medicine currently available. Development of a safe, comfortable and non-invasive wearable pre-void alarm and associated technology, using advanced mechatronics, is underway (the MyPAD device). Each stage of development includes patient and public involvement (PPI), particularly with respect to human factors, in collaboration with physicians, radiologists, psychologists, nurses, engineers and designers. OBJECTIVES: The aim of this study was to help us understand the families' experience of the condition of enuresis, and to provide opinion relating to existing NE alarms, designed to detect moisture, and most importantly, the initial design of the MyPAD wearable technology. METHODS: A PPI workshop in the form of a focus group, made up of children with enuresis and their parents, was conducted during the early stage of the MyPAD product development. The key research questions (RQs) were: (RQ1) What were the families' experiences of using existing post-void enuresis alarms? (RQ2) What do families like about the MyPAD prototype? and (RQ3) What do families not like about the MyPAD prototype? A nurse specialised in terms of NE treatment, including post-void alarms, from the Lancashire Teaching Hospitals NHS Foundation Trust, and two MyPAD design engineers were also present, to explain the MyPAD design concept. Braun and Clarke's six-phase approach to thematic analysis was implemented, which included familiarisation with the data, initial descriptive coding, identifying themes, reviewing themes, defining and labelling themes and producing a report. RESULTS: Four common themes were identified from the focus group discussions: the importance of sleep; children do not want to feel different; parents feel frustrated and concerned; resilience and perseverance. These themes applied across the research questions; for example, sleep disruption was highlighted as an issue with existing post-void alarms and as an important requirement for the design of MyPAD. The evaluation of the early version of the MyPAD device has prompted the consideration of changes to some existing facets of the device, including providing multiple alarm types, more options for the design of the garment that houses the device, and the need for clear, age-appropriate and informative instructions relating to how the device should be used, in order to maximise its performance/efficiency and acceptance. CONCLUSIONS: The qualitative data derived from the focus group discussion was incredibly valuable as it enabled the research and design team to experience the perspectives of the families in terms of the challenges and conflicts of managing the condition and the limited utility of existing post-void alarms. This has improved our understanding of the social and environmental challenges that will need to be considered during the design process.


Asunto(s)
Diseño de Equipo/métodos , Enuresis Nocturna/terapia , Niño , Humanos , Enuresis Nocturna/psicología , Participación del Paciente , Ultrasonografía , Dispositivos Electrónicos Vestibles
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA