1.
G Ital Cardiol (Rome) ; 24(10): 831-833, 2023 Oct.
Artículo en Italiano | MEDLINE | ID: mdl-37767836

RESUMEN

Atrial septal defects (ASD) represent the most common congenital heart defect diagnosed in adulthood. Adults with an ASD are often asymptomatic, but sometimes may present with non-specific symptoms such as dyspnea on exertion or exercise intolerance. Isolated sinus venosus atrial defect is an extremely rare anomaly. Sinus venosus defects occur more commonly in the superior (rather than inferior) portion of the embryologic sinus venosus and commonly occur with partial anomalous pulmonary venous return, particularly of the right upper pulmonary vein. We describe the case of an 80-year-old man with an undiagnosed, hemodynamically significant superior sinus venosus type of ASD who presented with persistent dyspnea and hypoxia after COVID-19 disease. Although cardiac magnetic resonance represents the gold standard for the morpho-functional evaluation of ASDs, transesophageal echocardiography is an accessible method for diagnosing the superior sinus venosus type of ASD and three-dimensional transesophageal echocardiography is useful for obtaining an "en face" view of the ASD and important surrounding structures.

3.
Thromb Res ; 216: 84-89, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35759818

RESUMEN

INTRODUCTION: Matrix metalloproteinases (MMPs) of atherosclerotic tissue contribute to plaque rupture triggering acute coronary syndromes (ACS). Several MMPs, including MMP-2, are also contained in platelets and released upon activation. An increase in circulating levels of MMP-2 has been reported in patients undergoing percutaneous coronary interventions (PCI), but its time-course and origin remain unclear. Aims of our study were to assess the time-course of MMP-2 release in blood of stable and unstable coronary artery disease patients undergoing PCI and to unravel the possible contribution of platelets to its release. METHODS: Peripheral blood samples were drawn immediately before, 4 and 24 h after PCI from patients with ACS (NSTEMI or STEMI, n = 21) or with stable angina (SA, n = 21). Platelet-poor plasma and washed platelet lysates were prepared and stored for subsequent assay of MMP-2 and ß-thromboglobulin (ß-TG), a platelet-specific protein released upon activation. RESULTS: Plasma MMP-2 and ß-TG increased significantly 4 h after PCI and returned to baseline at 24 h in ACS patients, while they did not change in SA patients. Platelet content of MMP-2 and ß-TG decreased significantly 4 h after PCI in patients with ACS, compatible with intravascular platelet activation and release, while they did not change in patients with SA. CONCLUSIONS: PCI triggers the release of MMP-2 in the circulation of ACS patients but not in that of patients with SA. Platelets activated by PCI contribute to the increase of plasma MMP-2 releasing their MMP-2 content. Given that previous mechanicistic studies have shown that MMP-2 may sustain platelet activation and unstabilize downstream-located plaques and in the long term favour restenosis and atherosclerosis progression, these data may encourage the search for therapeutic agents blocking MMP-2 release or activity in ACS.


Asunto(s)
Síndrome Coronario Agudo , Aterosclerosis , Metaloproteinasa 2 de la Matriz/sangre , Intervención Coronaria Percutánea , Síndrome Coronario Agudo/tratamiento farmacológico , Aterosclerosis/metabolismo , Plaquetas/metabolismo , Humanos , Metaloproteinasa 2 de la Matriz/metabolismo , Activación Plaquetaria
4.
J Clin Med ; 10(16)2021 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-34441762

RESUMEN

BACKGROUND: Cardiology divisions reshaped their activities during the coronavirus disease 2019 (COVID-19) pandemic. This study aimed to analyze the organization of echocardiographic laboratories and echocardiography practice during the second wave of the COVID-19 pandemic in Italy, and the expectations for the post-COVID era. METHODS: We analyzed two different time periods: the month of November during the second wave of the COVID-19 pandemic (2020) and the identical month during 2019 (November 2019). RESULTS: During the second wave of the COVID-19 pandemic, the hospital activity was partially reduced in 42 (60%) and wholly interrupted in 3 (4%) echocardiographic laboratories, whereas outpatient echocardiographic activity was partially reduced in 41 (59%) and completely interrupted in 7 (10%) laboratories. We observed an important change in the organization of activities in the echocardiography laboratory which reduced the operator-risk and improved self-protection of operators by using appropriate personal protection equipment. Operators wore FFP2 in 58 centers (83%) during trans-thoracic echocardiography (TTE), in 65 centers (93%) during transesophageal echocardiography (TEE) and 63 centers (90%) during stress echocardiography. The second wave caused a significant reduction in number of echocardiographic exams, compared to November 2019 (from 513 ± 539 to 341 ± 299 exams per center, -34%, p < 0.001). On average, there was a significant increase in the outpatient waiting list for elective echocardiographic exams (from 32.0 ± 28.1 to 45.5 ± 44.9 days, +41%, p < 0.001), with a reduction of in-hospital waiting list (2.9 ± 2.4 to 2.4 ± 2.0 days, -17%, p < 0.001). We observed a large diffusion of point-of-care cardiac ultrasound (88%), with a significant increase of lung ultrasound usage in 30 centers (43%) during 2019, extended to all centers in 2020. Carbon dioxide production by examination is an indicator of the environmental impact of technology (100-fold less with echocardiography compared to other cardiac imaging techniques). It was ignored in 2019 by 100% of centers, and currently it is considered potentially crucial for decision-making in cardiac imaging by 65 centers (93%). CONCLUSIONS: In one year, major changes occurred in echocardiography practice and culture. The examination structure changed with extensive usage of point-of-care cardiac ultrasound and with lung ultrasound embedded by default in the TTE examination, as well as the COVID-19 testing.

5.
EuroIntervention ; 13(3): 355-363, 2017 06 20.
Artículo en Inglés | MEDLINE | ID: mdl-28218604

RESUMEN

AIMS: Bioresorbable vascular scaffolds (BVS) represent a novel therapeutic option for the treatment of coronary artery diseases. The objective of this study was to evaluate the feasibility of BVS implantation in complex chronic total occlusions (CTO). METHODS AND RESULTS: The present report is a multicentre registry evaluating results after BVS deployment in challenging CTO lesions, defined as J-CTO score ≥2 (difficult or very difficult). A total of 105 patients were included in the present analysis. The mean J-CTO score was 2.61 (difficult 52.4%, very difficult 47.6%). Device success and procedural success rates were 98.1% and 97.1%, respectively. The retrograde approach was used in 25.7% of cases. After wire crossing, predilatation was performed in all cases with a mean predilatation balloon diameter of 2.73±0.43 mm. The mean scaffold length was 59.75±25.85 mm, with post-dilatation performed in 89.5% of the cases and a mean post-dilatation balloon diameter of 3.35±0.44 mm. Post-PCI minimal lumen diameter was 2.50±0.51 mm and percentage diameter stenosis 14.53±10.31%. At six-month follow-up, a total of three events were reported: one periprocedural myocardial infarction, one late scaffold thrombosis and one additional target lesion revascularisation. CONCLUSIONS: The present report suggests the feasibility of BVS implantation in complex CTO lesions, given adequate lesion preparation and post-dilatation, with good acute angiographic results and midterm clinical outcomes.


Asunto(s)
Implantes Absorbibles , Enfermedad de la Arteria Coronaria/terapia , Oclusión Coronaria/terapia , Everolimus/uso terapéutico , Adulto , Anciano , Enfermedad Crónica , Stents Liberadores de Fármacos/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/métodos , Sistema de Registros , Andamios del Tejido/efectos adversos , Resultado del Tratamiento
6.
Int J Cardiol ; 221: 656-64, 2016 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-27423087

RESUMEN

BACKGROUND: Limited data are available on bioresorbable vascular scaffolds (BVS) performance in bifurcations lesions and on the impact of BVS wider struts on side-branch impairment. METHODS: Patients with at least one coronary bifurcation lesion involving a side-branch ≥2mm in diameter and treated with at least one BVS were examined. Procedural and angiographic data were collected and a dedicated methodology for off-line quantitative coronary angiography (QCA) in bifurcation was applied (eleven-segment model), to assess side-branch impairment occurring any time during the procedure. Two- and three-dimensional QCA were used. Optical coherence tomography (OCT) analysis was performed in a subgroup of patients and long-term clinical outcomes reported. RESULTS: A total of 102 patients with 107 lesions, were evaluated. Device- and procedural-successes were 99.1% and 94.3%, respectively. Side-branch impairment occurring any time during the procedure was reported in 13 bifurcations (12.1%) and at the end of the procedure in 6.5%. Side-branch minimal lumen diameter (Pre: 1.45±0.41mm vs Final: 1.48±0.42mm, p=0.587) %diameter-stenosis (Pre: 26.93±16.89% vs Final: 27.80±15.57%, p=0.904) and minimal lumen area (Pre: 1.97±0.89mm(2) vs Final: 2.17±1.09mm(2), p=0.334), were not significantly affected by BVS implantation. Mean malapposed struts at the bifurcation polygon-of-confluence were 0.63±1.11. CONCLUSIONS: The results of the present investigation suggest feasibility and relative safety of BVS implantation in coronary bifurcations. BVS wide struts have a low impact on side-branch impairment when considering bifurcations with side-branch diameter≥2mm.


Asunto(s)
Implantes Absorbibles , Enfermedad de la Arteria Coronaria/cirugía , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Polímeros , Andamios del Tejido , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Encuestas y Cuestionarios , Tomografía de Coherencia Óptica/métodos
7.
EuroIntervention ; 12(1): 30-7, 2016 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-27173859

RESUMEN

AIMS: Limited data are currently available on midterm outcomes after implantation of everolimus-eluting bioresorbable vascular scaffolds (BVS) for treatment of acute ST-elevation myocardial infarction (STEMI). METHODS AND RESULTS: Patients presenting with STEMI and undergoing primary percutaneous coronary intervention in the initial experience with BVS were evaluated and compared with patients treated with everolimus-eluting metal stents (EES) by applying propensity matching. Quantitative coronary angiography analysis, and 18-month clinical follow-up were reported. A total of 302 patients were analysed, 151 with BVS and 151 with EES. Baseline clinical characteristics were similar between groups. Final TIMI 3 flow was 87.4% vs. 86.1%, p=0.296. At 18-month follow-up, all-cause mortality was 2.8% vs. 3.0% in the BVS and EES groups respectively, p=0.99; the MACE rate was higher in the BVS group (9.8% vs. 3.6%, p=0.02); target lesion revascularisation was 5.7% vs. 1.3%, p=0.05. The 30-day MACE rate in BVS patients without post-dilatation was 6.8%, while in patients with post-dilatation it was 3.6%. Scaffold thrombosis (ST) occurred primarily in the acute phase (acute ST 2.1% vs. 0.7%, p=0.29; subacute 0.7% vs. 0.7%, p=0.99; late 0.0% vs. 0.0%; very late 1.5% vs. 0.0%, p=0.18). All three BVS cases with acute ST had no post-dilatation at the index procedure. CONCLUSIONS: STEMI patients treated during the early experience with BVS had similar acute angiographic results as compared with the EES group. Clinical midterm follow-up data showed a higher clinical events rate compared with metal stents. The majority of clinical events occurred in the early phase after implantation and mainly in cases without post-dilatation. Optimisation of the implantation technique in the acute clinical setting is of paramount importance for optimal short and mid-term outcomes.


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/uso terapéutico , Stents Liberadores de Fármacos , Everolimus/farmacología , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST/terapia , Enfermedad Aguda , Adolescente , Adulto , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/métodos , Resultado del Tratamiento , Adulto Joven
8.
Minerva Cardioangiol ; 64(1): 1-8, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26446510

RESUMEN

BACKGROUND: The purpose of this registry is to report the immediate and long-term safety and efficacy of the Biotronik Orsiro stent in an unselected population during everyday practice. METHODS: Between May 2012 and June 2013, 246 consecutive coronary angioplasty procedures were performed using at least one Orsiro drug-eluting stent, in 225 patients and 303 lesions. RESULTS: Diabetes was present in 34.7% of patients. Procedures were non-elective percutaneous coronary intervention (PCI) in 17.1% of cases and acute coronary syndromes were 55.1%. Radial vascular access was used in 78% of cases, multivessel PCI was performed in 19.5% of the procedures. In 81.6% of cases lesions were B2/C type, 20.7% of procedures had bifurcation lesions. Procedural success was 99.6%. No acute thrombosis occurred. Clinical follow-up median period was 24.3 (±8.28) months and FU was available in 93.7% of patients. Death for any cause occurred in 11 patients (5.2%), 6 of them were non cardiac-related. Cardiac-related death rate was 2.4%. Two patients had in-stent restenosis. The overall target lesion failure rate was 3.3%. CONCLUSIONS: This observational data regards our experience with Biotronik Orsiro stent in an unselected population. This initial data, although limited by a mainly clinical follow-up and restricted number of patients, confirms the good clinical performance of this sirolimus-eluting stent with a biodegradable polymer in everyday practice, including complex lesions, according to current larger studies in the literature.


Asunto(s)
Angioplastia Coronaria con Balón/métodos , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/métodos , Sirolimus/administración & dosificación , Síndrome Coronario Agudo/terapia , Anciano , Stents Liberadores de Fármacos/efectos adversos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Polímeros/química , Diseño de Prótesis , Sistema de Registros , Resultado del Tratamiento
9.
Eur J Cardiothorac Surg ; 49(2): 478-85, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25769464

RESUMEN

OBJECTIVE: To determine whether the Trifecta bioprosthetic aortic valve produces postoperative haemodynamic results comparable with or better than those of the Magna Ease aortic valve bioprosthesis. METHODS: We retrospectively reviewed the medical records of patients who had undergone aortic valve replacement with Trifecta or Magna Ease prostheses at eight European institutions between January 2011 and May 2013, and analysed early postoperative haemodynamic performance by means of echocardiography. RESULTS: A total of 791 patients underwent aortic valve replacement (469 Magna Ease, 322 Trifecta). Haemodynamic variables were evaluated on discharge and during the follow-up (minimum 6 months, maximum 12 months). The mean gradient and the indexed effective orifice area (IEOA) were as follows: 10 mmHg [interquartile range (IQR): 8-13] and 1.10 cm(2)/m(2) (IQR: 0.95-1.27) for Trifecta; 16 mmHg (IQR: 11-22) and 0.96 cm(2)/m(2) (IQR: 0.77-1.13) for Magna Ease (P < 0.001). These significant differences were maintained across all valve sizes. Similar statistically significant differences were found when patients were matched and/or stratified for preoperative characteristics: body-surface area, ejection fraction, mean gradients and valve size. Severe prosthesis-patient mismatch (IEOA: <0.65 cm(2)/m(2)) was detected in 2 patients (0.6%) with Trifecta and 40 patients (8.5%) with Magna Ease (P < 0.001). CONCLUSIONS: The haemodynamic performance of the Trifecta bioprosthesis was superior to that of the Magna Ease valve across all conventional prosthesis sizes, with almost no incidence of severe patient-prosthesis mismatch. The long-term follow-up is needed to determine whether these significant haemodynamic differences will persist, and influence clinical outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Prótesis Valvulares Cardíacas , Anciano , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Ecocardiografía/mortalidad , Femenino , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Hemodinámica/fisiología , Mortalidad Hospitalaria , Humanos , Masculino , Diseño de Prótesis , Ajuste de Prótesis , Estudios Retrospectivos
10.
J Interv Cardiol ; 25(2): 203-9, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22272568

RESUMEN

BACKGROUND: Despite several advantages of the transradial over the transfemoral approach, the use of transradial access for coronary interventions in daily practice is still low. Major limitations are the technical and anatomical issues related with right radial artery access. The left radial approach may have an advantage from the point of view of the vascular anatomy. The aim of this study was to evaluate the safety and feasibility of routinely using the left radial compared to the right radial approach. METHODS: This is a prospective single center study comparing left radial to right radial access for coronary artery catheterization. The overall in-hospital major adverse cardiac and cerebral events (MACCE), procedural success rate, bleeding, vascular and procedural complications, fluoroscopy time, number of catheters, and amount of contrast agent used were assessed. RESULTS: A total of 1,032 coronary angiograms were performed: 420 were performed using the right radial artery and 612 the left radial artery. No differences were observed in MACCE and success rate between the two groups. No cases of major or minor bleeding and vascular complications requiring surgical intervention were reported. Fluoroscopy time and the number of catheters used were significantly less in the left radial group (P = 0.001 and P = 0.007, respectively), while the volume of contrast was similar (P = 0.264). CONCLUSIONS: The left radial approach in our series was demonstrated to be safe and feasible in daily practice, and in this study was associated with a reduction in fluoroscopy time and number of catheters used.


Asunto(s)
Cateterismo Cardíaco/métodos , Angiografía Coronaria/métodos , Arteria Radial , Cateterismo Cardíaco/efectos adversos , Angiografía Coronaria/efectos adversos , Fluoroscopía , Humanos , Estudios Prospectivos
11.
Eur J Cardiovasc Prev Rehabil ; 18(3): 526-32, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21450642

RESUMEN

BACKGROUND: The purpose of this study is to present data on the effects of pre-hospital electrocardiogram (PH-ECG) on the outcome of ST elevation myocardial infarction (STEMI) patients treated with percutaneous coronary angioplasty (PCI) included in a registry undertaken in the Italian region of Lombardy. Pre-hospital 12-lead electrocardiogram is recommended by current guidelines in order to achieve faster times to reperfusion in patients with STEMI. METHODS: The registry includes 3901 STEMI patients who underwent primary PCI over an 18-month period. RESULTS: Mean age was 63 ± 12 years. Admission through the emergency medical system (EMS) occurred in 1603 patients (40%): they were older, more frequently had previous MI, TIMI flow = 0 at entry and were more frequently in Killip class >1 than patients who were not admitted through the EMS. Among the patients admitted through the EMS, PH-ECG was obtained in 475 patients (12%). These patients had less frequently an anterior MI, but more frequently had absence of TIMI flow at entry than patients whose ECG was not teletransmitted. Moreover, they had a significantly shorter first medical contact-to-balloon time and a trend toward a lower 30-day death rate (5.3% vs 7.9 %, p = 0.06). However, only patients in Killip class 2-3 had a significantly lower mortality when the diagnostic ECG was transmitted, whereas no difference was found in Killip class 1 or Killip class 4 patients. CONCLUSIONS: In this registry, PH-ECG significantly decreased first medical contact-to-balloon time. Attempts to achieve faster reperfusion times should be undertaken, as this may result in improved outcome, particularly in patients with mild to moderate symptoms of heart failure.


Asunto(s)
Angioplastia Coronaria con Balón , Electrocardiografía , Servicios Médicos de Urgencia/métodos , Infarto del Miocardio/terapia , Sistema de Registros , Femenino , Estudios de Seguimiento , Humanos , Italia/epidemiología , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/mortalidad , Pronóstico , Estudios Retrospectivos , Tasa de Supervivencia/tendencias , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA