Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
Sleep Med Rev ; 75: 101930, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38761649

RESUMEN

There is no consensus on the definition of sleep hygiene and its components. We examined the definition of sleep hygiene based on its use in published studies. Four databases (Medline, EMBASE, PsycINFO and CINAHL) were searched from inception until December 31, 2021 for the phrase 'sleep hygiene' in the title or abstract. We identified 548 relevant studies in adults: 250 observational and 298 intervention studies. A definition of sleep hygiene was provided in only 44% of studies and converged on three themes: behavioural factors, environmental factors, and an aspect of control. Sleep hygiene components were explicitly defined in up to 70% of observational studies, but in only 35% of intervention studies. The most commonly considered components of sleep hygiene were caffeine (in 51% of studies), alcohol (46%), exercise (46%), sleep timing (45%), light (42%), napping (39%), smoking (38%), noise (37%), temperature (34%), wind-down routine (33%), stress (32%), and stimulus control (32%), although the specific details of each component varied. Lack of consistency in definitions of sleep hygiene and its components may hinder communication between researchers, clinicians, and the public, and likely limits the utility of sleep hygiene as an intervention.


Asunto(s)
Higiene del Sueño , Humanos , Ejercicio Físico , Sueño/fisiología , Cafeína
2.
Heart Lung Circ ; 31(4): 462-468, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34656439

RESUMEN

INTRODUCTION: Experienced echocardiographers can quickly glean diagnostic information from limited echocardiographic views. The use of limited cardiac ultrasound, particularly as a screening tool, is increasing. During the COVID-19 pandemic, limited cardiac ultrasound has the major advantage of reducing exposure time between sonographer and patient. The sensitivity and negative predictive value of a "screening" echocardiogram with highly limited views is uncertain. AIM/METHOD: We examined the accuracy of limited echocardiography in 203 consecutive, de novo studies. We used six images: parasternal long axis, with colour Doppler over the mitral valve, and aortic valve, and apical four-chamber with colour Doppler over the mitral valve, and tricuspid valve. We compared the interpretation of 12 subjects with the final echocardiogram report, (gold standard). The subjects comprised four experienced echocardiography-specialised cardiologists, four experienced cardiologists with non-imaging subspecialty interests, and four senior cardiac sonographers. Studies were graded as: (1) normal or (2) needs full study (due to inadequate images or abnormality detected). Sensitivity, specificity, negative predictive value, positive predictive value and accuracy are reported. RESULTS: Forty-one per cent (41%) of studies were normal by the gold standard report. Overall, a screening echocardiogram had a sensitivity of 71.2%, specificity of 57.1% to detect an abnormal echocardiogram, negative predictive value 58.4%, positive predictive value of 70.2%, and accuracy of 65.4%. When inadequate images were excluded, overall accuracy was nearly identical at 64.6%. The overall accuracy between the three groups of interpreters was similar: 66.5% (95% CI 63.1-69.7) for echocardiography-specialised cardiologists, 65.3% (95% CI 61.9-68.5) for non-echocardiography specialised cardiologists, and 64.4% (95% CI 61.0-67.7) for sonographers. These groups are all highly experienced practitioners. There was no difference in sensitivity or specificity comparing echocardiography-specialised cardiologists with cardiologists of other subspecialty experience. Comparing cardiologists to sonographers, cardiologists had lower sensitivity (echocardiography specialists 67.6%, 95% CI 63.2-71.8, non-echocardiography specialists 62.0%, 95% CI 57.4-66.4) compared to sonographers (84.0% [95% CI 80.4-87.2, p<0.05]), but cardiologists had higher specificities (64.9% [95% CI 59.5-70.0] for the echocardiography specialists, and 69.9% [95% CI 64.7-74.8] for non echocardiography specialists), compared to 36.6% (95% CI 31.4-42.0, p<0.05) for the sonographer group. When looking at only the studies considered to be interpretable, cardiologists had higher positive predictive value (echocardiography specialists 73.7%, 95% CI 69.0-78.1, non echocardiography specialists 74.1%, 95% CI 68.8-79.9), as compared to sonographers (64.3%, 95% CI 59.8-68.5%). CONCLUSIONS: Limited cardiac ultrasound as a screening tool for a normal heart had a sensitivity of only 71%, when performed and interpreted by experienced personnel, raising questions regarding the safety of this practice. Caution is especially recommended in extrapolating its use to non-specialised settings.


Asunto(s)
COVID-19 , Pandemias , Ecocardiografía/métodos , Humanos , Tamizaje Masivo , Válvula Mitral
3.
ESC Heart Fail ; 8(5): 4346-4352, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34382353

RESUMEN

AIMS: This study aimed to explore the rapid effects of dapagliflozin in heart failure with reduced ejection fraction (HFrEF). METHODS AND RESULTS: We studied the functional, echocardiographic, electrophysiological, lung ultrasound, ambulatory blood pressure (BP), microvascular and macrovascular function, and biochemical effects of 2 week treatment with dapagliflozin in 19 type 2 diabetic HFrEF patients in a double-blind, crossover, placebo-controlled trial. Dapagliflozin had no significant effect on clinical, functional, or quality of life parameters. Dapagliflozin reduced systolic BP [114 (105, 131) vs. 106 (98, 113) mmHg, P < 0.01] and diastolic BP [71 (61, 78) vs. 62 (55, 70) mmHg, P < 0.01]. There was no effect on cardiac chamber size, ventricular systolic function, lung ultrasound, or arterial wave reflection. Dapagliflozin increased creatinine [117 (92, 129) vs. 122 (107, 135) µmol/L, P < 0.05] and haemoglobin [135 (118, 138) vs. 136 (123, 144) g/L, P < 0.05]. There was a reduction in ventricular ectopy [1.4 (0.1, 2.9) vs. 0.2 (0.1, 1.4) %, P < 0.05] and an increase in standard deviation of normal heart beat intervals [70 (58, 90) vs. 74 (62, 103), P < 0.05]. Unexpectedly, dapagliflozin increased high-sensitivity troponin T [25 (19, 37) vs. 28 (20, 42) ng/L, P < 0.01] and reduced reactive hyperaemia index [1.29 (1.21, 1.56) vs. 1.40 (1.23, 1.84), P < 0.05]. CONCLUSIONS: After 2 weeks, while multiple parameters supported BP reduction and haemoconcentration with dapagliflozin, reduction in cardiac filling pressure, lung water, and functional improvement was not shown. Reduced ventricular ectopic burden suggests an early antiarrhythmic benefit. The small increase in troponin T and the reduction in the reactive hyperaemia index warrant further mechanistic exploration in this treatment of proven mortality benefit in HFrEF.


Asunto(s)
Diabetes Mellitus Tipo 2 , Insuficiencia Cardíaca , Compuestos de Bencidrilo , Monitoreo Ambulatorio de la Presión Arterial , Estudios Cruzados , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Glucósidos , Insuficiencia Cardíaca/tratamiento farmacológico , Humanos , Calidad de Vida , Volumen Sistólico
4.
Health Promot J Austr ; 32 Suppl 2: 106-115, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33462929

RESUMEN

ISSUE ADDRESSED: Drowning is a global public health issue. Aims were to assess: (a) face validity of the "Pictorial Scale of Perceived Water Competence (PSPWC)," (b) the association between child and parent perception of child swimming competence and (c) factors associated with perception of child swimming competence. METHODS: Child-parent dyads and swim instructors were recruited for a mixed method study. Children aged 4-8 years (n = 51) reported on: familiarity, progressions and their own swim competence in 17 swimming situations. Parents (n = 51) reported on child competence and swimming experience. Swim instructors (n = 15) were interviewed. Spearman's rank correlation was used to assess whether child and parent swim perception were associated. The Mann-Whitney U test, Wilcoxon signed-rank test or Kruskal-Wallis test were used to assess which factors were associated with child and/or parent report. RESULTS: Children reported high familiarity of scenarios and could sequence items. Swim instructors concluded the PSPWC depicted swim skills accurately. There was no association between child and parent perception of children's swimming ability. Swimming level was positively associated with child perception but not parent proxy report. Swimming lesson experience, child sex, country of birth and disadvantage were not associated with child perception or parent proxy report. Older children perceived higher swimming competence but parent report was not associated with child age. CONCLUSIONS: Children have a better understanding of their swim competence than their parents do, suggesting parent education is needed. SO WHAT?: The PSPWC could be used by teachers (both swimming and classroom) to inform parents how their child estimates their swim competence. If use of this tool was incorporated into education practice this could assist in creating awareness, which can be the start of advocacy towards the creation of policy to assist in the provision of accessible swim education for all Australian children.


Asunto(s)
Ahogamiento , Natación , Adolescente , Australia , Niño , Escolaridad , Humanos , Percepción
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA