Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Magn Reson Imaging ; 85: 108-120, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34653578

RESUMEN

PURPOSE: Diffusion-weighted imaging (DWI) may aid accurate tumor grading. Decreased diffusivity and increased diffusion heterogeneity measures have been observed in high-grade gliomas using the non-monoexponential models for DWI. However, DWI measures concerning tissue characteristics in terms of pathophysiological and structural changes are yet to be established. Thus, this study aims to investigate the relationship between the diffusion measurements and microstructural changes in the presence of high-grade gliomas using a three-dimensional Monte Carlo simulation with systematic changes of microstructural parameters. METHODS: Water diffusion was simulated in a microenvironment along with changes associated with the presence of high-grade gliomas, including increases in cell density, nuclear volume, extracellular volume (VFex), and extracellular tortuosity (λex), and changes in membrane permeability (Pmem). DWI signals were simulated using a pulsed gradient spin-echo sequence. The sequence parameters, including the maximum gradient strength and diffusion time, were set to be comparable to those of clinical scanners and advanced human MRI systems. The DWI signals were fitted using the gamma distribution and diffusional kurtosis models with b-values up to 6000 and 2500 s/mm2, respectively. RESULTS: The diffusivity measures (apparent diffusion coefficients (ADC), Dgamma of the gamma distribution model and Dapp of the diffusional kurtosis model) decreased with increases in cell density and λex, and a decrease in Pmem. These diffusivity measures increased with increases in nuclear volume and VFex. The diffusion heterogeneity measures (σgamma of the gamma distribution model and Kapp of the diffusional kurtosis model) increased with increases in cell density or nuclear volume at the low Pmem, and a decrease in Pmem. Increased σgamma was also associated with an increase in VFex. CONCLUSION: Among simulated microstructural changes, only increases in cell density at low Pmem or decreases in Pmem corresponded to both the decreased diffusivity and increased diffusion heterogeneity measures. The results suggest that increases in cell density at low Pmem or decreases in Pmem may be associated with the diffusion changes observed in high-grade gliomas.


Asunto(s)
Neoplasias Encefálicas , Glioma , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/patología , Difusión , Imagen de Difusión por Resonancia Magnética/métodos , Glioma/diagnóstico por imagen , Glioma/patología , Humanos , Método de Montecarlo , Clasificación del Tumor , Microambiente Tumoral
2.
N Engl J Med ; 379(9): 846-855, 2018 08 30.
Artículo en Inglés | MEDLINE | ID: mdl-30157388

RESUMEN

BACKGROUND: There are limited treatments for progressive multiple sclerosis. Ibudilast inhibits several cyclic nucleotide phosphodiesterases, macrophage migration inhibitory factor, and toll-like receptor 4 and can cross the blood-brain barrier, with potential salutary effects in progressive multiple sclerosis. METHODS: We enrolled patients with primary or secondary progressive multiple sclerosis in a phase 2 randomized trial of oral ibudilast (≤100 mg daily) or placebo for 96 weeks. The primary efficacy end point was the rate of brain atrophy, as measured by the brain parenchymal fraction (brain size relative to the volume of the outer surface contour of the brain). Major secondary end points included the change in the pyramidal tracts on diffusion tensor imaging, the magnetization transfer ratio in normal-appearing brain tissue, the thickness of the retinal nerve-fiber layer, and cortical atrophy, all measures of tissue damage in multiple sclerosis. RESULTS: Of 255 patients who underwent randomization, 129 were assigned to ibudilast and 126 to placebo. A total of 53% of the patients in the ibudilast group and 52% of those in the placebo group had primary progressive disease; the others had secondary progressive disease. The rate of change in the brain parenchymal fraction was -0.0010 per year with ibudilast and -0.0019 per year with placebo (difference, 0.0009; 95% confidence interval, 0.00004 to 0.0017; P=0.04), which represents approximately 2.5 ml less brain-tissue loss with ibudilast over a period of 96 weeks. Adverse events with ibudilast included gastrointestinal symptoms, headache, and depression. CONCLUSIONS: In a phase 2 trial involving patients with progressive multiple sclerosis, ibudilast was associated with slower progression of brain atrophy than placebo but was associated with higher rates of gastrointestinal side effects, headache, and depression. (Funded by the National Institute of Neurological Disorders and Stroke and others; NN102/SPRINT-MS ClinicalTrials.gov number, NCT01982942 .).


Asunto(s)
Encéfalo/patología , Esclerosis Múltiple Crónica Progresiva/tratamiento farmacológico , Inhibidores de Fosfodiesterasa/uso terapéutico , Piridinas/uso terapéutico , Adulto , Atrofia/prevención & control , Encéfalo/diagnóstico por imagen , Depresión/inducido químicamente , Imagen de Difusión Tensora , Progresión de la Enfermedad , Método Doble Ciego , Femenino , Enfermedades Gastrointestinales/inducido químicamente , Cefalea/inducido químicamente , Humanos , Masculino , Persona de Mediana Edad , Esclerosis Múltiple Crónica Progresiva/patología , Inhibidores de Fosfodiesterasa/efectos adversos , Piridinas/efectos adversos
3.
Magn Reson Imaging ; 53: 105-111, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30048675

RESUMEN

PURPOSE: To assess intrascanner repeatability and cross-scanner comparability for diffusion tensor imaging (DTI) metrics in a multicenter clinical trial. METHODS: DTI metrics (including longitudinal diffusivity [LD], fractional anisotropy [FA], mean diffusivity [MD], and transverse diffusivity [TD]) from pyramidal tracts for healthy controls were calculated from images acquired on twenty-seven 3T MR scanners (Siemens and GE) with 6 different scanner models and 7 different software versions as part of the NN102/SPRINT-MS clinical trial. Each volunteer underwent two scanning sessions on the same scanner. Signal-to-noise ratio (SNR) and signal-to-noise floor ratio (SNFR) were also assessed. RESULTS: DTI metrics showed good scan-rescan repeatability. There were no significant differences between scans and rescans in LD, FA, MD, or TD values. Although the cross-scanner coefficient of variation (CV) values for all DTI metrics were <5.7%, significant differences were observed for LD (p < 3.3e-5) and FA (p < 0.0024) when GE scanners were compared with Siemens scanners. Significant differences were also observed for SNR when comparing GE scanners and Siemens Skyra scanners (p < 1.4e-7) and when comparing Siemens Skyra scanners and TIM Trio scanners (p < 1.0e-10). Analysis of background signal also demonstrated differences between GE and Siemens scanners in terms of signal statistics. The measured signal intensity from a background noise region of interest was significantly higher for GE scanners than for Siemens scanners (p < 1.2e-12). Significant differences were also observed for SNFR when comparing GE scanners and Siemens Skyra scanners (p < 2.5e-11), GE scanners and Siemens Trio scanners (p < 7.5e-11), and Siemens Skyra scanners and TIM Trio scanners (p < 2.5e-9). CONCLUSIONS: The good repeatability of the DTI metrics among the 27 scanners used in this study confirms the feasibility of combining DTI data from multiple centers using high angular resolution sequences. Our observations support the feasibility of longitudinal multicenter clinical trials using DTI outcome measures. The noise floor level and SNFR are important parameters that must be assessed when comparing studies that used different scanner models.


Asunto(s)
Imagen de Difusión Tensora/instrumentación , Imagen de Difusión Tensora/métodos , Adulto , Anisotropía , Encéfalo/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética , Femenino , Voluntarios Sanos , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Fantasmas de Imagen , Control de Calidad , Cintigrafía , Reproducibilidad de los Resultados , Relación Señal-Ruido , Adulto Joven
4.
Magn Reson Imaging ; 35: 81-90, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27587227

RESUMEN

A phantom-based quality assurance (QA) protocol was developed for a multicenter clinical trial including high angular resolution diffusion imaging (HARDI). A total of 27 3T MR scanners from 2 major manufacturers, GE (Discovery and Signa scanners) and Siemens (Trio and Skyra scanners), were included in this trial. With this protocol, agar phantoms doped to mimic relaxation properties of brain tissue are scanned on a monthly basis, and quantitative procedures are used to detect spiking and to evaluate eddy current and Nyquist ghosting artifacts. In this study, simulations were used to determine alarm thresholds for minimal acceptable signal-to-noise ratio (SNR). Our results showed that spiking artifact was the most frequently observed type of artifact. Overall, Trio scanners exhibited less eddy current distortion than GE scanners, which in turn showed less distortion than Skyra scanners. This difference was mainly caused by the different sequences used on these scanners. The SNR for phantom scans was closely correlated with the SNR from volunteers. Nearly all of the phantom measurements with artifact-free images were above the alarm threshold, suggesting that the scanners are stable longitudinally. Software upgrades and hardware replacement sometimes affected SNR substantially but sometimes did not. In light of these results, it is important to monitor longitudinal SNR with phantom QA to help interpret potential effects on in vivo measurements. Our phantom QA procedure for HARDI scans was successful in tracking scanner performance and detecting unwanted artifacts.


Asunto(s)
Encéfalo/anatomía & histología , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/normas , Fantasmas de Imagen , Garantía de la Calidad de Atención de Salud/métodos , Adulto , Artefactos , Mapeo Encefálico/métodos , Mapeo Encefálico/normas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Relación Señal-Ruido , Adulto Joven
5.
Stereotact Funct Neurosurg ; 92(5): 306-14, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25247480

RESUMEN

BACKGROUND: Applications in clinical medicine can benefit from fusion of spectroscopy data with anatomical imagery. For example, new 3-dimensional (3D) spectroscopy techniques allow for improved correlation of metabolite profiles with specific regions of interest in anatomical tumor images, which can be useful in characterizing and treating heterogeneous tumors that appear structurally homogeneous. OBJECTIVES: We sought to develop a clinical workflow and uniquely capable custom software tool to integrate advanced 3-tesla 3D proton magnetic resonance spectroscopic imaging ((1)H-MRSI) into industry standard image-guided neuronavigation systems, especially for use in brain tumor surgery. METHODS: (1)H-MRSI spectra from preoperative scanning on 15 patients with recurrent or newly diagnosed meningiomas were processed and analyzed, and specific voxels were selected based on their chemical contents. 3D neuronavigation overlays were then generated and applied to anatomical image data in the operating room. The proposed 3D methods fully account for scanner calibration and comprise tools that we have now made publicly available. RESULTS: The new methods were quantitatively validated through a phantom study and applied successfully to mitigate biopsy uncertainty in a clinical study of meningiomas. CONCLUSIONS: The proposed methods improve upon the current state of the art in neuronavigation through the use of detailed 3D (1)H-MRSI data. Specifically, 3D MRSI-based overlays provide comprehensive, quantitative visual cues and location information during neurosurgery, enabling a progressive new form of online spectroscopy-guided neuronavigation.


Asunto(s)
Encéfalo/cirugía , Neoplasias Meníngeas/cirugía , Meningioma/cirugía , Neuronavegación/métodos , Espectroscopía de Protones por Resonancia Magnética , Encéfalo/metabolismo , Encéfalo/patología , Mapeo Encefálico , Humanos , Neoplasias Meníngeas/metabolismo , Neoplasias Meníngeas/patología , Meningioma/metabolismo , Meningioma/patología , Programas Informáticos
6.
J Magn Reson ; 230: 19-26, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23428968

RESUMEN

The aim of this study was to investigate the microstructural sensitivity of the statistical distribution and diffusion kurtosis (DKI) models of non-monoexponential signal attenuation in the brain using diffusion-weighted MRI (DWI). We first developed a simulation of 2-D water diffusion inside simulated tissue consisting of semi-permeable cells and a variable cell size. We simulated a DWI acquisition of the signal in a volume using a pulsed gradient spin echo (PGSE) pulse sequence, and fitted the models to the simulated DWI signals using b-values up to 2500 s/mm(2). For comparison, we calculated the apparent diffusion coefficient (ADC) of the monoexponential model (b-value=1000 s/mm(2)). In separate experiments, we varied the cell size (5-10-15 µm), cell volume fraction (0.50-0.65-0.80), and membrane permeability (0.001-0.01-0.1mm/s) to study how the fitted parameters tracked simulated microstructural changes. The ADC was sensitive to all the simulated microstructural changes except the decrease in membrane permeability. The ADC increased with larger cell size, smaller cell volume fraction, and larger membrane permeability. The σstat of the statistical distribution model increased exclusively with a decrease in cell volume fraction. The Kapp of the DKI model was exclusively increased with decreased cell size and decreased with increasing membrane permeability. These results suggest that the non-monoexponential models of water diffusion have different, specific microstructural sensitivity, and a combination of the models may give insights into the microstructural underpinning of tissue pathology.


Asunto(s)
Agua Corporal/metabolismo , Difusión , Imagen por Resonancia Magnética/métodos , Modelos Biológicos , Modelos Estadísticos , Agua/química , Simulación por Computador , Método de Montecarlo , Distribuciones Estadísticas , Agua/análisis
7.
Magn Reson Med ; 70(2): 497-503, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23023533

RESUMEN

Faster periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) diffusion-weighted imaging acquisitions, such as Turboprop and X-prop, remain subject to phase errors inherent to a gradient echo readout, which ultimately limits the applied turbo factor (number of gradient echoes between each pair of radiofrequency refocusing pulses) and, thus, scan time reductions. This study introduces a new phase correction to Turboprop, called Turboprop+. This technique employs calibration blades, which generate 2-D phase error maps and are rotated in accordance with the data blades, to correct phase errors arising from off-resonance and system imperfections. The results demonstrate that with a small increase in scan time for collecting calibration blades, Turboprop+ had a superior immunity to the off-resonance-related artifacts when compared to standard Turboprop and recently proposed X-prop with the high turbo factor (turbo factor = 7). Thus, low specific absorption rate and short scan time can be achieved in Turboprop+ using a high turbo factor, whereas off-resonance related artifacts are minimized.


Asunto(s)
Algoritmos , Artefactos , Imagen de Difusión por Resonancia Magnética/métodos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Procesamiento de Señales Asistido por Computador , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
8.
Vasc Health Risk Manag ; 8: 599-611, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23109807

RESUMEN

BACKGROUND: Alzheimer's disease (AD) dementia is a consequence of heterogeneous and complex interactions of age-related neurodegeneration and vascular-associated pathologies. Evidence has accumulated that there is increased atherosclerosis/arteriosclerosis of the intracranial arteries in AD and that this may be additive or synergistic with respect to the generation of hypoxia/ischemia and cognitive dysfunction. The effectiveness of pharmacologic therapies and lifestyle modification in reducing cardiovascular disease has prompted a reconsideration of the roles that cardiovascular disease and cerebrovascular function play in the pathogenesis of dementia. METHODS: Using two-dimensional phase-contrast magnetic resonance imaging, we quantified cerebral blood flow within the internal carotid, basilar, and middle cerebral arteries in a group of individuals with mild to moderate AD (n = 8) and compared the results with those from a group of age-matched nondemented control (NDC) subjects (n = 9). Clinical and psychometric testing was performed on all individuals, as well as obtaining their magnetic resonance imaging-based hippocampal volumes. RESULTS: Our experiments reveal that total cerebral blood flow was 20% lower in the AD group than in the NDC group, and that these values were directly correlated with pulse pressure and cognitive measures. The AD group had a significantly lower pulse pressure (mean AD 48, mean NDC 71; P = 0.0004). A significant group difference was also observed in their hippocampal volumes. Composite z-scores for clinical, psychometric, hippocampal volume, and hemodynamic data differed between the AD and NDC subjects, with values in the former being significantly lower (t = 12.00, df = 1, P = 0.001) than in the latter. CONCLUSION: These results indicate an association between brain hypoperfusion and the dementia of AD. Cardiovascular disease combined with brain hypoperfusion may participate in the pathogenesis/pathophysiology of neurodegenerative diseases. Future longitudinal and larger-scale confirmatory investigations measuring multidomain parameters are warranted.


Asunto(s)
Enfermedad de Alzheimer/fisiopatología , Arterias Cerebrales/fisiopatología , Anciano , Anciano de 80 o más Años , Enfermedad de Alzheimer/metabolismo , Enfermedad de Alzheimer/psicología , Apolipoproteína E4/metabolismo , Presión Sanguínea/fisiología , Estudios de Casos y Controles , Circulación Cerebrovascular/fisiología , Cognición/fisiología , Estudios de Cohortes , Femenino , Hipocampo/patología , Humanos , Angiografía por Resonancia Magnética/métodos , Imagen por Resonancia Magnética , Masculino , Proyectos Piloto , Psicometría
9.
Magn Reson Med ; 66(2): 341-7, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21661046

RESUMEN

Diffusion-weighted imaging (DWI) has shown great benefits in clinical MR exams. However, current DWI techniques have shortcomings of sensitivity to distortion or long scan times or combinations of the two. Diffusion-weighted echo-planar imaging (EPI) is fast but suffers from severe geometric distortion. Periodically rotated overlapping parallel lines with enhanced reconstruction diffusion-weighted imaging (PROPELLER DWI) is free of geometric distortion, but the scan time is usually long and imposes high Specific Absorption Rate (SAR) especially at high fields. TurboPROP was proposed to accelerate the scan by combining signal from gradient echoes, but the off-resonance artifacts from gradient echoes can still degrade the image quality. In this study, a new method called X-PROP is presented. Similar to TurboPROP, it uses gradient echoes to reduce the scan time. By separating the gradient and spin echoes into individual blades and removing the off-resonance phase, the off-resonance artifacts in X-PROP are minimized. Special reconstruction processes are applied on these blades to correct for the motion artifacts. In vivo results show its advantages over EPI, PROPELLER DWI, and TurboPROP techniques.


Asunto(s)
Algoritmos , Artefactos , Imagen de Difusión por Resonancia Magnética/métodos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Almacenamiento y Recuperación de la Información/métodos , Imagen por Resonancia Magnética/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
10.
J Magn Reson Imaging ; 27(4): 685-91, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18302232

RESUMEN

The Alzheimer's Disease Neuroimaging Initiative (ADNI) is a longitudinal multisite observational study of healthy elders, mild cognitive impairment (MCI), and Alzheimer's disease. Magnetic resonance imaging (MRI), (18F)-fluorodeoxyglucose positron emission tomography (FDG PET), urine serum, and cerebrospinal fluid (CSF) biomarkers, as well as clinical/psychometric assessments are acquired at multiple time points. All data will be cross-linked and made available to the general scientific community. The purpose of this report is to describe the MRI methods employed in ADNI. The ADNI MRI core established specifications that guided protocol development. A major effort was devoted to evaluating 3D T(1)-weighted sequences for morphometric analyses. Several options for this sequence were optimized for the relevant manufacturer platforms and then compared in a reduced-scale clinical trial. The protocol selected for the ADNI study includes: back-to-back 3D magnetization prepared rapid gradient echo (MP-RAGE) scans; B(1)-calibration scans when applicable; and an axial proton density-T(2) dual contrast (i.e., echo) fast spin echo/turbo spin echo (FSE/TSE) for pathology detection. ADNI MRI methods seek to maximize scientific utility while minimizing the burden placed on participants. The approach taken in ADNI to standardization across sites and platforms of the MRI protocol, postacquisition corrections, and phantom-based monitoring of all scanners could be used as a model for other multisite trials.


Asunto(s)
Enfermedad de Alzheimer/diagnóstico , Encéfalo/patología , Imagen por Resonancia Magnética/métodos , Anciano , Enfermedad de Alzheimer/patología , Humanos , Imagen por Resonancia Magnética/normas
11.
J Magn Reson Imaging ; 19(3): 291-7, 2004 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-14994296

RESUMEN

PURPOSE: To quantify changes in signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), specific absorption rate (SAR), RF power deposition, and imaging time in cardiac magnetic resonance imaging with and without the application of parallel imaging at 1.5 T and 3.0 T. MATERIALS AND METHODS: Phantom and volunteer data were acquired at 1.5 T and 3.0 T with and without parallel imaging. RESULTS: Doubling field strength increased phantom SNR by a factor of 1.83. In volunteer data, SNR and CNR values increased by factors of 1.86 and 1.35, respectively. Parallel imaging (reduction factor = 2) decreased phantom SNR by a factor of 1.84 and 2.07 when compared to the full acquisition at 1.5 T and 3.0 T, respectively. In volunteers, SNR and CNR decreased by factors of 2.65 and 2.05 at 1.5 T and 1.99 and 1.75 at 3.0 T, respectively. Doubling the field strength produces a nine-fold increase in SAR (0.0751 to 0.674 W/kg). Parallel imaging reduced the total RF power deposition by a factor of two at both field strengths. CONCLUSIONS: Parallel imaging decreases total scan time at the expense of SNR and CNR. These losses are compensated at higher field strengths. Parallel imaging is effective at reducing total power deposition by reducing total scan time.


Asunto(s)
Corazón/anatomía & histología , Imagen por Resonancia Magnética/métodos , Adulto , Análisis de Varianza , Artefactos , Estudios de Factibilidad , Humanos , Aumento de la Imagen , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/estadística & datos numéricos , Magnetismo , Masculino , Fantasmas de Imagen , Valores de Referencia , Sensibilidad y Especificidad , Procesamiento de Señales Asistido por Computador , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA