RESUMEN
Cardioneuroablation has emerged as a potential alternative to cardiac pacing in selected cases with vasovagal reflex syncope, extrinsic vagally induced sinus bradycardia-arrest or atrioventricular block. The technique was first introduced decades ago, and its use has risen over the past decade. However, as with any intervention, proper patient selection and technique are a prerequisite for a safe and effective use of cardioneuroablation therapy. This document aims to review and interpret available scientific evidence and provide a summary position on the topic.
Asunto(s)
Bradicardia , Síncope Vasovagal , Humanos , Bradicardia/terapia , Bradicardia/fisiopatología , Bradicardia/cirugía , Bradicardia/diagnóstico , Síncope Vasovagal/cirugía , Síncope Vasovagal/diagnóstico , Síncope Vasovagal/fisiopatología , Resultado del Tratamiento , Ablación por Catéter/métodos , Consenso , Frecuencia Cardíaca , Técnicas de AblaciónRESUMEN
AIMS: Left atrial catheter ablation is well established in patients with symptomatic atrial fibrillation (AF) but associated with risk of embolism to the brain. The present analysis aims to assess the impact of diffusion-weighted imaging (DWI) slice thickness on the rate of magnetic resonance imaging (MRI)-detected ischaemic brain lesions after ablation. METHODS AND RESULTS: AXAFA-AFNET 5 trial (NCT02227550) participants underwent MRI using high-resolution (hr) DWI (slice thickness: 2.5-3â mm) and standard DWI (slice thickness: 5-6â mm) within 3-48â h after ablation. In 321 patients with analysable brain MRI (mean age 64 years, 33% female, median CHA2DS2-VASc 2), hrDWI detected at least one acute brain lesion in 84 (26.2%) patients and standard DWI in 60 (18.7%; P < 0.01) patients. High-resolution diffusion-weighted imaging detected more lesions compared to standard DWI (165 vs. 104; P < 0.01). The degree of agreement for lesion confirmation using hrDWI vs. standard DWI was substantial (κ = 0769). Comparing the proportion of DWI-detected lesions, lesion distribution, and total lesion volume per patient, there was no difference in the cohort of participants undergoing MRI at 1.5â T (n = 52) vs. 3â T (n = 269). CONCLUSION: The pre-specified AXAFA-AFNET 5 sub-analysis revealed significantly increased rates of MRI-detected acute brain lesions using hrDWI instead of standard DWI in AF patients undergoing ablation. In comparison to DWI slice thickness, MRI field strength had a no significant impact in the trial. Comparing the varying rates of ablation-related MRI-detected brain lesions across previous studies has to consider these technical parameters. Future studies should use hrDWI, as feasibility was demonstrated in the multicentre AXAFA-AFNET 5 trial.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Femenino , Persona de Mediana Edad , Masculino , Imagen por Resonancia Magnética/métodos , Imagen de Difusión por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversosAsunto(s)
Síncope Vasovagal , Humanos , Síncope Vasovagal/diagnóstico , Síncope Vasovagal/cirugía , Bradicardia , ReflejoRESUMEN
[Figure: see text].
Asunto(s)
Sistema Nervioso Autónomo/fisiopatología , Ablación por Catéter/efectos adversos , Frecuencia Cardíaca/fisiología , Síndrome del Seno Enfermo/cirugía , Cirugía Asistida por Computador/métodos , Síncope Vasovagal/fisiopatología , Tomografía Computarizada por Rayos X/métodos , Adolescente , Adulto , Anciano , Ablación por Catéter/métodos , Femenino , Estudios de Seguimiento , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Estudios Prospectivos , Síndrome del Seno Enfermo/diagnóstico , Síndrome del Seno Enfermo/fisiopatología , Síncope Vasovagal/etiología , Factores de Tiempo , Adulto JovenRESUMEN
Background Biatrial, extensive, and complex ablation strategies have been published for the treatment of neurally mediated syncope, sinus node dysfunction, and functional atrioventricular block. We have developed a less extensive and more specific approach compared with previously published cardioneuroablation strategies, called cardio-neuromodulation. It is based on tailored vagolysis of the sinoatrial node through partial ablation of the anterior right-ganglionated plexus, preferentially through a right-sided approach. Methods Patients with syncope were enrolled between December 2016 and December 2017. They were assigned to group A if they had a positive head-up tilt test and to group B if they presented with a pause ≥3 seconds. The area to target during cardio-neuromodulation was designed offline on a computed tomographic scan. Slow heart rates and pauses were compared during 24-hour rhythm registration at baseline, at 1-month follow-up, and 6-month follow-up. Syncope burden was assessed before the procedure and at 3- and 6-month follow-up. Results Twenty patients underwent cardio-neuromodulation through a right-sided approach (12 in group A, 8 in group B). The first application of radiofrequency energy led to a P-P interval shortening >120 ms in all 20 patients. After a mean±SD ablation time of 7±4 minutes and mean ablated surface area of 11±6 mm2, the P-P interval shortened by 219±160 ms ( P<0.001). The number of beats <50/min during 24-hour rhythm registration was reduced by a median of 100% at 6-month follow-up ( P<0.001). Syncope burden was reduced by 95% at 6-month follow-up ( P<0.001). Conclusions These data indicate that cardio-neuromodulation, through a right-sided and computed tomographic-guided procedure, is safe, fast, and highly reproducible in preventing inappropriate functional sinus bradycardia and syncope recurrence.
Asunto(s)
Ablación por Catéter/métodos , Radiografía Intervencional/métodos , Síndrome del Seno Enfermo/cirugía , Síncope Vasovagal/etiología , Tomografía Computarizada por Rayos X , Potenciales de Acción , Adulto , Anciano , Bélgica , Bradicardia/etiología , Bradicardia/fisiopatología , Ablación por Catéter/efectos adversos , Electrocardiografía Ambulatoria , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Recurrencia , Síndrome del Seno Enfermo/complicaciones , Síndrome del Seno Enfermo/diagnóstico , Síndrome del Seno Enfermo/fisiopatología , Síncope Vasovagal/diagnóstico , Síncope Vasovagal/fisiopatología , Pruebas de Mesa Inclinada , Factores de Tiempo , Resultado del Tratamiento , Adulto JovenRESUMEN
AIMS: This study aimed to assess the safety and efficacy at midterm follow-up of left atrial appendage occlusion (LAAO) using different devices, in real life in Belgium. METHODS AND RESULTS: Between June 2009 and November 2016, 457 consecutive patients (63% male, 75±12 yrs, CHA2DS2-VASc 4±0.6, HAS-BLED 3.5±0.7) undergoing LAAO were included. Technical success was 97.1%. There were 19 periprocedural major adverse events (4.1%) including three deaths (0.6%), nine tamponades (1.9%), four major bleedings (0.8%) and two device embolisations (0.4%). Among patients successfully implanted having a complete follow-up (672 patient-years, median follow-up 370 days), the actual annual stroke rate was 1.2%, lower than the expected stroke risk of 4% (70% reduction). The observed bleeding rate was 2%, while the calculated risk was 3.7% (46% reduction). Kaplan-Meier analysis showed a similar overall survival (93±2% and 87±3% versus 91±3% and 87±4%; p=0.35) and event-free survival (92±2% and 84±3% versus 88±3% and 80±5%; p=0.17) at one and two years, for the ACP/Amulet versus the WATCHMAN groups of patients, respectively. CONCLUSIONS: The data from the Belgian left atrial appendage occlusion registry suggest that the procedure is effective and relatively safe in a real-world setting, using either the WATCHMAN or the ACP/Amulet device.
Asunto(s)
Apéndice Atrial , Fibrilación Atrial/terapia , Cateterismo Cardíaco , Accidente Cerebrovascular/prevención & control , Anciano , Anciano de 80 o más Años , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/fisiopatología , Fibrilación Atrial/complicaciones , Fibrilación Atrial/mortalidad , Fibrilación Atrial/fisiopatología , Bélgica , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Ecocardiografía Transesofágica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sistema de Registros , Factores de Riesgo , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/mortalidad , Factores de Tiempo , Resultado del TratamientoRESUMEN
Background: Important developments in materials, devices, and techniques have improved outcomes of chronic total occlusion (CTO) percutaneous coronary intervention (PCI), and resulted in a growing interest in CTO-PCI. The Belgian Working Group on Chronic Total Occlusions (BWGCTO) working group aims to assess the evolution within the CTO-PCI landscape over the next years. Methods: From May 2016 onwards, patients undergoing CTO-PCI were included in the BWGCTO registry by 15 centres in Belgium and Luxemburg. Baseline, angiographic, and procedural data were collected. Here, we report on the one-year in-hospital outcomes. Results: Over the course of one year, 411 procedures in 388 patients were included with a mean age of 64 ± 11 years. The majority were male (81%). Relatively complex CTOs were treated (Japanese CTO score =2.2 ± 1.2) with a high procedure success rate (82%). Patient- and lesion-wise success rates were 83 and 85%, respectively. Major adverse in-hospital events were acceptably low (3.4%). Antegrade wire escalation technique was applied most frequently (82%). On the other hand, antegrade dissection and re-entry and retrograde strategies were more frequently applied in higher volume centres and successful for lesions with higher complexity. Conclusion: Satisfactory procedural outcomes and a low rate of adverse events were obtained in a complex CTO population, treated by operators with variable experience levels. Antegrade wire escalation was the preferred strategy, regardless of operator volume.
Asunto(s)
Intervención Coronaria Percutánea , Bélgica , Femenino , Humanos , Luxemburgo , Masculino , Persona de Mediana Edad , Sistema de Registros , Resultado del TratamientoRESUMEN
Syncope is frequently neurally mediated and can seriously affect quality of life. Different ablation strategies have been successfully performed. These approaches have not gained wide acceptance and are quite extensive and complex, exposing patients to significant risks. This article reports the case of a 16-year-old girl who was severely affected by frequent and prolonged episodes of syncope and was treated by tailored ablation of the anterior right ganglionated plexus with a multielectrode irrigated catheter. She had fainted >30 times in the 5 years preceding treatment, experiencing approximately 10 severe episodes of syncope in the previous 12 months. After 3 minutes of ablation, the P-P interval was reduced by >400 milliseconds. Syncope disappeared and the patient has remained completely asymptomatic over a follow-up of 22 months. The "reset" basal P-P interval has remained unchanged (follow-up electrocardiogram at 16 months). At 6 months, there was no residual heart rate activity <50 bpm. On 24-hour rhythm registration, P-P intervals ≥1,000 milliseconds (corresponding to a heart rate of ≤60 bpm) were reduced by >16,000 beats. We believe that this case report is original for several reasons: the unusual clinical presentation; the unique structure targeted; the very limited ablation, implying much lower risks for the patient; the anatomical approach; and the different endpoint. This new "cardio-neuromodulation" approach could be useful for the treatment of patients with neurally mediated syncope.
Asunto(s)
Catéteres Cardíacos , Ablación por Catéter/instrumentación , Ganglios Parasimpáticos/cirugía , Nodo Sinoatrial/inervación , Síncope/terapia , Irrigación Terapéutica/instrumentación , Potenciales de Acción , Adolescente , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Diseño de Equipo , Femenino , Ganglios Parasimpáticos/fisiopatología , Frecuencia Cardíaca , Humanos , Recurrencia , Síncope/diagnóstico , Síncope/fisiopatología , Resultado del TratamientoRESUMEN
BACKGROUND: Radiofrequency ablation (RFA) can unfavorably cause coagulum on the ablation electrode. The aim of this study was to assess this phenomenon on three different multielectrode catheters used to treat persistent atrial fibrillation with duty-cycled RFA. METHODS AND RESULTS: Twenty-six consecutive patients have been treated with the pulmonary vein ablation catheter (PVAC) and the multiarray ablation catheter (MAAC). In 13 patients, additional ablation with the multiarray septal catheter (MASC) has been performed. The multichannel RF generator GENius™ (Medtronic Inc., Minneapolis, MN, USA) independently delivered energy in a bipolar and unipolar mode (ratio of 4/1, 2/1, or 1/1) to any of the electrodes. Versions 14.2, 14.3, and 14.4 of the generator were used. Coagulum presence was determined postablation by careful visual inspection of the catheter electrodes. No coagulum formation was visualized on the PVACs. Coagulum formation was visualized in 59% of the electrodes of the MAACs using a 2/1 mode and the 14.2 software version versus 69% using the 14.4 version and a 2/1 mode (P = 0.7) versus 14% of the electrodes applying a 1/1 ratio and the 14.4 software version (P < 0.001). CONCLUSIONS: Duty-cycled RFA in 2/1 bipolar/unipolar ratio generates a substantial frequency of coagulum formation on the multielectrode catheters MAAC and MASC. The use of the 14.4 version of the software to drive the RF generator and the use of energy in the default 1/1 bipolar/unipolar ratio could significantly reduce the frequency of coagulum formation, but so far, could not completely overcome it. The PVAC did not form coagulum, regardless of generator version or energy ratio used.
Asunto(s)
Fibrilación Atrial/sangre , Fibrilación Atrial/cirugía , Coagulación Sanguínea/efectos de la radiación , Ablación por Catéter/efectos adversos , Ablación por Catéter/instrumentación , Electrodos/efectos adversos , Embolia/etiología , Adulto , Enfermedad Crónica , Diseño de Equipo , Falla de Equipo , Análisis de Falla de Equipo , Femenino , Calor/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Ondas de Radio , Resultado del TratamientoAsunto(s)
Fascículo Atrioventricular Accesorio/fisiopatología , Fascículo Atrioventricular Accesorio/cirugía , Ablación por Catéter/métodos , Sistema de Conducción Cardíaco/fisiopatología , Sistema de Conducción Cardíaco/cirugía , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Prueba de Esfuerzo , Humanos , Masculino , Adulto JovenRESUMEN
BACKGROUND: This prospective, multicenter study sought to evaluate the incidence of asymptomatic cerebral emboli (ACE) during ablation of atrial fibrillation (AF) using a multielectrode radiofrequency (MER) system when specific procedural changes were applied. METHODS AND RESULTS: Sixty subjects (age 60±10 years; 87% paroxysmal; CHADS2 score, 0.6±0.7) undergoing AF ablation with a circular MER catheter were studied. Three procedural changes were specified: (1) ablation was performed under therapeutic vitamin K antagonist and heparin to maintain activated clotting time>350 seconds; (2) submerged loading of the catheter into the introducer before sheath insertion to minimize air ingress; and (3) either the distal or proximal electrode of the circular MER catheter was deactivated to prevent inadvertent bipolar radiofrequency interaction. MRI was performed <7 days preablation and 2 days postablation. Subjects with new cerebral findings after ablation underwent repeat MRI after 1 month. An acute ACE lesion was defined by a new hyperintensity on diffusion-weighted and fluid-attenuated inversion recovery cerebral MRI sequences. Neurological function was evaluated at baseline, postablation, and 1 month. All target pulmonary veins were isolated. In 60% (36/60) of patients, pre-existing cerebral lesions were seen on the preprocedure MRI (8 lesions per subject; interquartile range, 3-22). New postprocedural ACE occurred in only 1/60 patients (incidence, 1.7%; 95% confidence interval, 0.04-8.9), which was no longer visible on MRI after 1 month. CONCLUSIONS: Applying procedural changes to MER ablation significantly reduces the ACE incidence to 1.7%, which is on the low end of reported ACE rates of any technology. CLINICAL TRIAL REGISTRATION INFORMATION: ClinicalTrials.gov; Identifier: NCT01520532.
Asunto(s)
Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Infarto Cerebral/epidemiología , Embolia Intracraneal/etiología , Enfermedad Crónica , Femenino , Humanos , Incidencia , Embolia Intracraneal/epidemiología , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Prevalencia , Estudios ProspectivosAsunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Anciano , Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/diagnóstico por imagen , Femenino , Humanos , Ligadura/métodos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , RadiografíaRESUMEN
Autosomal recessive spastic ataxia of Charlevoix-Saguenay (ARSACS) is characterized by the presence of myelinated retinal fibers. This typical feature is very helpful for the diagnosis but is not always observed in patients outside Quebec. Apart from phenotype variations, misinterpretation of the funduscopy may explain discrepancies and misdiagnosis. We analyze the modification of retinal fibers layer using the funduscopy and the optical coherence tomography (OCT) in two French patients having spinocerebellar ataxia associated with a spastic paraparesia with genetically confirmed ARSACS. In both patients the funduscopy showed a swollen and striated aspect of peripapillar fibers along the retinal vessels and in the intermaculopapillar region. The OCT displayed an important thickening of the optical fibers layer mainly in upper and lower temporal area without attenuation of deep layers, as well as a filling in of the foveolar depression with thickening of the ganglion cell layer normally absent from the foveola. The aspect of funduscopy and OCT in our patients does not correspond to the classical description of myelin fibers encountered in 0.3% to 1% of the population. Thus, ARSACS might be underdiagnosed because of an erroneous interpretation of funduscopy. When considering the diagnosis of ARSACS, the neurologist should ask the ophthalmologist to search for thickening of peripapillar retinal fibers by both funduscopy and OCT rather than myelinated retinal fibers. This ophthalmological consideration has avoided misdiagnosis and led to the description of new mutations in our cases.
Asunto(s)
Espasticidad Muscular/diagnóstico , Fibras Nerviosas Mielínicas/patología , Neuronas Retinianas/patología , Ataxias Espinocerebelosas/congénito , Adulto , Femenino , Humanos , Masculino , Espasticidad Muscular/genética , Retina/patología , Ataxias Espinocerebelosas/diagnóstico , Ataxias Espinocerebelosas/genéticaRESUMEN
BACKGROUND: Optical coherence tomography has emerged as a new tool for quantifying axonal loss in multiple sclerosis (MS). A reduction in retinal nerve fiber layer (RNFL) thickness is correlated with Expanded Disability Status Scale score and brain atrophy. OBJECTIVE: To investigate RNFL and macular volume measurements using optical coherence tomography in the clinically isolated syndrome population. DESIGN: Prospective case series. Settings Neurologic clinics at the university hospitals of Lille and Strasbourg (France). PARTICIPANTS: Fifty-six consecutive patients with clinically isolated syndrome (18 with optic neuritis and 38 without optic neuritis) and 32 control subjects. MAIN OUTCOME MEASURES: Macular volume and RNFL thickness. RESULTS: Mean (SD) overall RNFL thickness (98.98 [10.26] microm) and macular volume (6.86 [0.32] microm(3)) in the clinically isolated syndrome population were not significantly different compared with the controls (98.71 [9.08] mum and 6.92 [0.38] microm(3), respectively). No link was noted between atrophy of the RNFL or macula and conversion to MS at 6 months. CONCLUSIONS: Optical coherence tomography does not reveal retinal axonal loss at the earliest clinical stage of MS and does not predict conversion to MS at 6 months.