Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Más filtros




Base de datos
Asunto de la revista
Intervalo de año de publicación
1.
Sci Rep ; 10(1): 21537, 2020 Dec 09.
Artículo en Inglés | MEDLINE | ID: mdl-33298995

RESUMEN

We report on the creation and characterization of the luminescence properties of high-purity diamond substrates upon F ion implantation and subsequent thermal annealing. Their room-temperature photoluminescence emission consists of a weak emission line at 558 nm and of intense bands in the 600-750 nm spectral range. Characterization at liquid He temperature reveals the presence of a structured set of lines in the 600-670 nm spectral range. We discuss the dependence of the emission properties of F-related optical centers on different experimental parameters such as the operating temperature and the excitation wavelength. The correlation of the emission intensity with F implantation fluence, and the exclusive observation of the afore-mentioned spectral features in F-implanted and annealed samples provides a strong indication that the observed emission features are related to a stable F-containing defective complex in the diamond lattice.

2.
Phys Rev Lett ; 117(17): 170402, 2016 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-27824450

RESUMEN

One of the most intriguing aspects of quantum mechanics is the impossibility of measuring at the same time observables corresponding to noncommuting operators, because of quantum uncertainty. This impossibility can be partially relaxed when considering joint or sequential weak value evaluation. Indeed, weak value measurements have been a real breakthrough in the quantum measurement framework that is of the utmost interest from both a fundamental and an applicative point of view. In this Letter, we show how we realized for the first time a sequential weak value evaluation of two incompatible observables using a genuine single-photon experiment. These (sometimes anomalous) sequential weak values revealed the single-operator weak values, as well as the local correlation between them.

3.
Phys Rev Lett ; 116(18): 180401, 2016 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-27203309

RESUMEN

Weak value measurements have recently given rise to a great amount of interest in both the possibility of measurement amplification and the chance for further quantum mechanics foundations investigation. In particular, a question emerged about weak values being proof of the incompatibility between quantum mechanics and noncontextual hidden variables theories (NCHVTs). A test to provide a conclusive answer to this question was given by Pusey [Phys. Rev. Lett. 113, 200401 (2014)], where a theorem was derived showing the NCHVT incompatibility with the observation of anomalous weak values under specific conditions. In this Letter we realize this proposal, clearly pointing out the connection between weak values and the contextual nature of quantum mechanics.

4.
Opt Lett ; 41(8): 1841-4, 2016 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-27082359

RESUMEN

We show how the same setup and procedure, exploiting spatially multimode quantum correlations, allows the absolute calibration of an electron-multiplying charge-coupled (EMCCD) camera from the analog regime down to the single-photon-counting level, just by adjusting the brightness of the quantum source. At the single-photon level, an EMCCD can be operated as an on-off detector, where quantum efficiency depends on the discriminating threshold. We develop a simple model to explain the connection of the two different regimes demonstrating that the efficiency estimated in the analog (bright) regime allows us to accurately predict the detector behavior in the photocounting regime and vice versa. This work establishes a bridge between two regions of the optical measurements that up to now have been based on completely different standards, detectors, and measurement techniques.

5.
Opt Lett ; 40(7): 1548-51, 2015 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-25831381

RESUMEN

Here we present a reconstruction of the positive operator-value measurement of a photon-number-resolving detector comprised of three 50∶50 beam-splitters in a tree configuration, terminated with four single-photon avalanche detectors. The four detectors' outputs are processed by an electronic board that discriminates detected photon number states from 0 to 4 and implements a "smart counting" routine to compensate for dead time issues at high count rates.

6.
Phys Rev Lett ; 113(14): 143602, 2014 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-25325642

RESUMEN

We experimentally demonstrate quantum enhanced resolution in confocal fluorescence microscopy exploiting the nonclassical photon statistics of single nitrogen-vacancy color centers in diamond. By developing a general model of superresolution based on the direct sampling of the kth-order autocorrelation function of the photoluminescence signal, we show the possibility to resolve, in principle, arbitrarily close emitting centers.

7.
Opt Lett ; 38(16): 3099-102, 2013 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-24104659

RESUMEN

In general, a pair of uncorrelated Gaussian states mixed in a beam splitter (BS) produces a correlated state at the output. However, when the inputs are identical Gaussian states the output state is equal to the input, and no correlations appear, as the interference had not taken place. On the other hand, since physical phenomena do have observable effects, and the BS is there, a question arises on how to reveal the interference between the two beams. We prove theoretically and demonstrate experimentally that this is possible if at least one of the two beams is prepared in a discordant, i.e., Gaussian correlated, state with a third beam. We also apply the same technique to reveal the erasure of polarization information. Our experiment involves thermal states and the results show that Gaussian discordant states, even when they show a positive Glauber P-function, may be useful to achieve specific tasks.

8.
Phys Rev Lett ; 110(21): 213601, 2013 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-23745871

RESUMEN

In recent years quantum correlations have received a lot of attention as a key ingredient in advanced quantum metrology protocols. In this Letter we show that they provide even larger advantages when considering multiple-interferometer setups. In particular, we demonstrate that the use of quantum correlated light beams in coupled interferometers leads to substantial advantages with respect to classical light, up to a noise-free scenario for the ideal lossless case. On the one hand, our results prompt the possibility of testing quantum gravity in experimental configurations affordable in current quantum optics laboratories and strongly improve the precision in "larger size experiments" such as the Fermilab holometer; on the other hand, they pave the way for future applications to high precision measurements and quantum metrology.

9.
Phys Rev Lett ; 110(15): 153603, 2013 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-25167266

RESUMEN

We present the first experimental realization of the quantum illumination protocol proposed by Lloyd [Science 321, 1463 (2008)] and S. Tan et al. [Phys. Rev. Lett. 101, 253601 (2008)], achieved in a simple feasible experimental scheme based on photon-number correlations. A main achievement of our result is the demonstration of a strong robustness of the quantum protocol to noise and losses that challenges some widespread wisdom about quantum technologies.

10.
Phys Rev Lett ; 108(25): 253601, 2012 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-23004600

RESUMEN

A quantum measurement can be described by a set of matrices, one for each possible outcome, which represents the positive operator-valued measure (POVM) of the sensor. Efficient protocols of POVM extraction for arbitrary sensors are required. We present the first experimental POVM reconstruction that takes explicit advantage of a quantum resource, i.e., nonclassical correlations with an ancillary state. A POVM of a photon-number-resolving detector is reconstructed by using strong quantum correlations of twin beams generated by parametric down-conversion. Our reconstruction method is more statistically robust than POVM reconstruction methods that use classical input states.

11.
Opt Express ; 19(23): 23249-57, 2011 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-22109203

RESUMEN

Well characterized photon number resolving detectors are a requirement for many applications ranging from quantum information and quantum metrology to the foundations of quantum mechanics. This prompts the necessity for reliable calibration techniques at the single photon level. In this paper we propose an innovative absolute calibration technique for photon number resolving detectors, using a pulsed heralded photon source based on parametric down conversion. The technique, being absolute, does not require reference standards and is independent upon the performances of the heralding detector. The method provides the results of quantum efficiency for the heralded detector as a function of detected photon numbers. Furthermore, we prove its validity by performing the calibration of a Transition Edge Sensor based detector, a real photon number resolving detector that has recently demonstrated its effectiveness in various quantum information protocols.

12.
Opt Express ; 19(2): 1484-92, 2011 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-21263690

RESUMEN

We present a heralded single-photon source with a much lower level of unwanted background photons in the output channel by using the herald photon to control a shutter in the heralded channel. The shutter is implemented using a simple field programable gate array controlled optical switch.


Asunto(s)
Iluminación/instrumentación , Dispositivos Ópticos , Procesamiento de Señales Asistido por Computador/instrumentación , Diseño Asistido por Computadora , Diseño de Equipo , Análisis de Falla de Equipo , Fotones
13.
Rev Sci Instrum ; 80(11): 116103, 2009 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-19947767

RESUMEN

We present an actively multiplexed photon-counting detection system at telecom wavelengths that overcomes the difficulties of photon-counting at high rates. We find that for gated detectors, the heretofore unconsidered deadtime associated with the detector gate is a critical parameter, that limits the overall scalability of the scheme to just a few detectors. We propose and implement a new scheme that overcomes this problem and restores full scalability that allows an order of magnitude improvement with systems with as few as 4 detectors. When using just two multiplexed detectors, our experimental results show a 5x improvement over a single detector and a greater than 2x improvement over multiplexed schemes that do not consider gate deadtime.

14.
Phys Rev Lett ; 103(19): 193602, 2009 Nov 06.
Artículo en Inglés | MEDLINE | ID: mdl-20365922

RESUMEN

We show that broadband biphoton wave packets produced via spontaneous parametric down-conversion in crystals with linearly aperiodic poling can be easily compressed in time using the effect of group-velocity dispersion in optical fibers. This result could foster important developments in quantum metrology and lithography.

15.
Phys Rev Lett ; 92(6): 060404, 2004 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-14995222

RESUMEN

We implemented the experiment proposed by Cabello in the preceding Letter to test the bounds of quantum correlation. As expected from the theory we found that, for certain choices of local observables, Tsirelson's bound of the Clauser-Horne-Shimony-Holt inequality (2 x square root of 2) is not reached by any quantum states.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA