Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 236
Filtrar
1.
Neuromuscul Disord ; 44: 104464, 2024 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-39368428

RESUMEN

Mexiletine (NaMuscla™) is indicated for the symptomatic treatment of myotonia in adults with non-dystrophic myotonia. A cardiac assessment is required as mexiletine may have a pro-arrhythmic effect. Long-term safety data supporting the use of mexiletine in patients with non-dystrophic myotonia combined with the extensive clinical experience of an expert group resulted in creation of an algorithm for cardiac monitoring of patients treated with mexiletine. To define the treatment algorithm, several expert workshops including three neurologists, five cardiologists from different French neuromuscular reference centers and one pharmacologist from Italy were set up. These workshops aimed to define the screening and surveillance tools required to ensure the safe use of mexiletine in patients. The recommendations are based on the summary of product characteristics (SmPC), a review of the literature on the safety of mexiletine-treated patients with non-dystrophic myotonia, and the expertise of the authors. The expert group concluded that the cardiac safety profile of mexiletine in these patients appears to be similar to that in the general population. Therefore, patients with non-dystrophic myotonia treated with mexiletine should be monitored as per any patient with cardiac problems who are prescribed a class 1b anti-arrhythmic.

2.
Europace ; 2024 Oct 14.
Artículo en Inglés | MEDLINE | ID: mdl-39397761

RESUMEN

Carotid sinus massage (CSM) as integral part of cardiovascular autonomic testing, is indicated in all patients > 40 years with syncope of unknown origin and suspected reflex mechanism. However, large practice variation exists in performing CSM which inevitably affects the positivity rate of the test and may result in an inaccurate diagnosis in patients with unexplained syncope. Even though CSM was introduced into medical practice more than 100 years ago, the method of performing CSM is still largely operator- and centre-dependent, while in many places the test has been entirely abandoned. Here we describe a standardized protocol on how to perform CSM, which basic monitoring equipment is necessary and why CSM is a safe procedure to perform. Our aim is to create an uniform approach to perform CSM. The new proposed algorithm, the Six Step Method includes: 1) Check history for exclusion CSM; 2) Turn head slightly contralaterally and posterior (see also explanatory video and poster provided as supplementary material; 3) Palpation to identify carotid sinus location; 4) Massage for 10 seconds; 5) Monitoring of blood pressure and heart rate to assess of the hemodynamic response type, and 6) Include time intervals between subsequent massages. CSM should be performed on both the left and right and in the supine and upright position. The recommended equipment to perform CSM consists of: 1) a tilt table in order to perform CSM in supine and standing position, 2) a continuous blood pressure monitor or cardiac monitor and 3) at least two persons.

4.
Eur Heart J ; 2024 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-39299922

RESUMEN

BACKGROUND AND AIMS: Prophylactic implantable cardioverter-defibrillators (ICDs) are not recommended until left ventricular ejection fraction (LVEF) has been reassessed 40 to 90 days after an acute myocardial infarction. In the current therapeutic era, the prognosis of sustained ventricular arrhythmias (VAs) occurring during this early post-infarction phase (i.e. within 3 months of hospital discharge) has not yet been specifically evaluated in post-myocardial infarction patients with impaired LVEF. Such was the aim of this retrospective study. METHODS: Data analysis was based on a nationwide registry of 1032 consecutive patients with LVEF ≤ 35% after acute myocardial infarction who were implanted with an ICD after being prescribed a wearable cardioverter-defibrillator (WCD) for a period of 3 months upon discharge from hospital after the index infarction. RESULTS: ICDs were implanted either because a sustained VA occurred while on WCD (VA+/WCD, n = 72) or because LVEF remained ≤35% at the end of the early post-infarction phase (VA-/WCD, n = 960). The median follow-up was 30.9 months. Sustained VAs occurred within 1 year after ICD implantation in 22.2% and 3.5% of VA+/WCD and VA-/WCD patients, respectively (P < .0001). The adjusted multivariable analysis showed that sustained VAs while on WCD independently predicted recurrence of sustained VAs at 1 year (adjusted hazard ratio [HR] 6.91; 95% confidence interval [CI] 3.73-12.81; P < .0001) and at the end of follow-up (adjusted HR 3.86; 95% CI 2.37-6.30; P < .0001) as well as 1-year mortality (adjusted HR 2.86; 95% CI 1.28-6.39; P = .012). CONCLUSIONS: In patients with LVEF ≤ 35%, sustained VA during the early post-infarction phase is predictive of recurrent sustained VAs and 1-year mortality.

5.
Arch Cardiovasc Dis ; 117(8-9): 542-557, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39271364

RESUMEN

Atrial fibrillation (AF) is the primary cause of ischaemic stroke and transient ischaemic attack (TIA). AF is associated with a high risk of recurrence, which can be reduced using optimal prevention strategies, mainly anticoagulant therapy. The availability of effective prophylaxis justifies the need for a significant, coordinated and thorough transdisciplinary effort to screen for AF associated with stroke. A recent French national survey, initiated and supported by the Société française neurovasculaire (SFNV) and the Société française de cardiologie (SFC), revealed many shortcomings, such as the absence or inadequacy of telemetry equipment in more than half of stroke units, insufficient and highly variable access to monitoring tools, delays in performing screening tests, heterogeneous access to advanced or connected ambulatory monitoring techniques, and a lack of dedicated human resources. The present scientific document has been prepared on the initiative of the SFNV and the SFC with the aim of helping to address the current shortcomings and gaps, to promote efficient and cost-effective AF detection, and to improve and, where possible, homogenize the quality of practice in AF screening among stroke units and outpatient post-stroke care networks. The working group, composed of cardiologists and vascular neurologists who are experts in the field and are nominated by their peers, reviewed the literature to propose statements, which were discussed in successive cycles, and maintained, either by consensus or by vote, as appropriate. The text was then submitted to the SFNV and SFC board members for review. This scientific statement document argues for the widespread development of patient pathways to enable the most efficient AF screening after stroke. This assessment should be carried out by a multidisciplinary team, including expert cardiologists and vascular neurologists.


Asunto(s)
Fibrilación Atrial , Consenso , Ataque Isquémico Transitorio , Accidente Cerebrovascular Isquémico , Valor Predictivo de las Pruebas , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/complicaciones , Fibrilación Atrial/terapia , Fibrilación Atrial/fisiopatología , Ataque Isquémico Transitorio/diagnóstico , Ataque Isquémico Transitorio/etiología , Ataque Isquémico Transitorio/terapia , Ataque Isquémico Transitorio/prevención & control , Accidente Cerebrovascular Isquémico/diagnóstico , Accidente Cerebrovascular Isquémico/etiología , Accidente Cerebrovascular Isquémico/prevención & control , Accidente Cerebrovascular Isquémico/terapia , Factores de Riesgo , Francia/epidemiología , Cardiología/normas , Pronóstico , Cardiólogos , Recurrencia
7.
JACC Clin Electrophysiol ; 10(9): 1982-1994, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38970599

RESUMEN

BACKGROUND: Idiopathic ventricular fibrillation (IVF) can be associated with undetected distinct conditions such as microstructural cardiomyopathic alterations (MiCM) or Purkinje (Purk) activities with structurally normal hearts. OBJECTIVES: This study sought to evaluate the characteristics of recurrent VF recorded on implantable defibrillator electrograms, associated with these substrates. METHODS: This was a multicenter collaboration study. At 32 centers, we selected patients with an initial diagnosis of IVF and recurrent arrhythmia at follow-up without antiarrhythmic drugs, in whom mapping demonstrated Purk or MiCM substrate. We analyzed variables related to previous ectopy, sinus rate preceding VF, trigger, and initial VF cycle lengths. Logistic regression with cross validation was used to evaluate the performance of criteria to discriminate Purk or MiCM substrates. RESULTS: Among 95 patients (35 women, age 35 ± 11 years) meeting the inclusion criteria, IVF was associated with MiCM in 41 and Purk in 54 patients. A total of 117 arrhythmia recurrences including 91% VF were recorded on defibrillator. Three variables were mostly discriminant. Sinus tachycardia (≤570 ms) was more frequent in MiCM (35.9% vs 13.4%, P = 0.014) whereas short-coupled (<350 ms) triggers were most frequent in Purk-related VF (95.5% vs 23.1%, P = 0.001), which also had shorter VFCLs (182 ± 15 ms vs 215 ± 24 ms, P < 0.001).The multivariable combination provided the highest prediction (accuracy = 0.93 ± 0.05, range 0.833-1.000), discriminating 81% of IVF substrates with a high probability (>80%). Ectopy were inconsistently present before VF. CONCLUSIONS: Characteristics of arrhythmia recurrences on implantable cardioverter- defibrillator provide phenotypic markers of the distinct and hidden substrates underlying IVF. These findings have significant clinical and genetic implications.


Asunto(s)
Desfibriladores Implantables , Fibrilación Ventricular , Humanos , Femenino , Fibrilación Ventricular/terapia , Fibrilación Ventricular/fisiopatología , Masculino , Adulto , Persona de Mediana Edad , Recurrencia , Cardiomiopatías/fisiopatología , Cardiomiopatías/terapia , Cardiomiopatías/complicaciones , Ramos Subendocárdicos/fisiopatología , Electrocardiografía
9.
Europace ; 26(8)2024 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-39082698

RESUMEN

Cardioneuroablation has emerged as a potential alternative to cardiac pacing in selected cases with vasovagal reflex syncope, extrinsic vagally induced sinus bradycardia-arrest or atrioventricular block. The technique was first introduced decades ago, and its use has risen over the past decade. However, as with any intervention, proper patient selection and technique are a prerequisite for a safe and effective use of cardioneuroablation therapy. This document aims to review and interpret available scientific evidence and provide a summary position on the topic.


Asunto(s)
Bradicardia , Síncope Vasovagal , Humanos , Bradicardia/terapia , Bradicardia/fisiopatología , Bradicardia/cirugía , Bradicardia/diagnóstico , Síncope Vasovagal/cirugía , Síncope Vasovagal/diagnóstico , Síncope Vasovagal/fisiopatología , Resultado del Tratamiento , Ablación por Catéter/métodos , Consenso , Frecuencia Cardíaca , Técnicas de Ablación
11.
Heart Rhythm ; 2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38810921

RESUMEN

BACKGROUND: Electrocardiographic screening before subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation is unsuccessful in around 10% of cases. A personalized screening method, by slightly moving the electrodes, to obtain a better R/T ratio has been described to overcome traditional screening failure. OBJECTIVE: The objectives of the SIS study were to assess to what extent a personalized screening method improves eligibility for S-ICD implantation and to evaluate the inappropriate shock rate after such screening success. METHODS: All consecutive patients eligible for an S-ICD implantation were prospectively recruited across 20 French centers between December 2019 and January 2022. In case of traditional screening failure, patients received a second personalized screening. If at least 1 vector was positive, the personalized screening was considered successful, and the patient was eligible for implantation. RESULTS: The study included 474 patients (mean age, 50.4 ± 14.1 years; 77.4% men). Traditional screening was successful in 456 (96.2%) cases. This figure rose to 98.3% (n = 466; P = .002) when personalized screening was performed. All patients implanted after successful personalized screening had correct signal detection on initial device interrogation. Nevertheless, after 1-year follow-up, 3 of the 7 patients (43%) implanted with personalized screening experienced inappropriate shock vs 18 of the 427 patients (4.2%) with traditional screening and S-ICD implantation (P = .003). CONCLUSION: Traditional S-ICD screening was successful in our study in a high proportion of patients. Considering the small improvement in success of screening and a higher rate of inappropriate shock, a strategy of personalized screening cannot be routinely recommended. CLINICALTRIALS: gov identifier: NCT04101253.

12.
Int J Cardiol ; 408: 132118, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38697397

RESUMEN

BACKGROUND: To assess long-term effectiveness and safety of edoxaban in Europe. METHODS AND RESULTS: ETNA-AF-Europe, a prospective, multinational, multi-centre, post-authorisation, observational study was conducted in agreement with the European Medicines Agency. The primary and secondary objectives assessed real-world safety (including bleeding and deaths) and effectiveness (including stroke, systemic embolic events and clinical edoxaban use), respectively. Median (interquartile range) age of the 13,164 patients was 75.0 (68.0-80.0) years; CHA2DS2-VASc and HAS-BLED scores were 3.0 (2.0-4.0) and 2.0 (1.0-2.0), respectively. Follow-up duration was 3.98 (3.21-4.05) years. Patients on edoxaban 30 mg (n = 3042) at baseline were older (80.0 vs 73.0 years), more likely assessed as frail by investigators (27.0% vs 6.6%) and had more comorbidities than those on edoxaban 60 mg (n = 9617; missing dosing information for n = 505). Annualised event rates of all-cause and cardiovascular death in the overall population, edoxaban 60 mg and edoxaban 30 mg groups were 4.1%, 2.8% and 8.4%, and 1.0%, 0.7% and 2.0%, respectively. Annualised rates of stroke were relatively constant throughout the follow-up, transient ischaemic attack and systemic embolism were < 1% in the overall population. Rates of any major and major gastrointestinal bleeding were low, with slightly higher rates for edoxaban 30 vs 60 mg group. Intracranial haemorrhage was uncommon (0.2%). CONCLUSIONS: In European patients with AF, long-term therapy with edoxaban is associated with low and relatively constant annualised rates of stroke and major bleeding. Differences in outcomes between the two approved doses are attributable to differences in clinical characteristics.


Asunto(s)
Fibrilación Atrial , Inhibidores del Factor Xa , Piridinas , Tiazoles , Humanos , Tiazoles/efectos adversos , Tiazoles/uso terapéutico , Tiazoles/administración & dosificación , Piridinas/efectos adversos , Piridinas/administración & dosificación , Piridinas/uso terapéutico , Anciano , Fibrilación Atrial/tratamiento farmacológico , Masculino , Femenino , Europa (Continente)/epidemiología , Estudios Prospectivos , Inhibidores del Factor Xa/efectos adversos , Inhibidores del Factor Xa/administración & dosificación , Inhibidores del Factor Xa/uso terapéutico , Anciano de 80 o más Años , Resultado del Tratamiento , Estudios de Seguimiento , Factores de Tiempo , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/epidemiología , Hemorragia/inducido químicamente , Hemorragia/epidemiología
13.
Arch Cardiovasc Dis ; 117(5): 304-312, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38704289

RESUMEN

BACKGROUND: Aortic valve infective endocarditis may be complicated by high-degree atrioventricular block in up to 10-20% of cases. AIM: To assess high-degree atrioventricular block occurrence, contributing factors, prognosis and evolution in patients referred for aortic infective endocarditis. METHODS: Two hundred and five patients referred for aortic valve infective endocarditis between January 2018 and March 2021 were included in this study. A comprehensive assessment of clinical, electrocardiographic, biological, microbiological and imaging data was conducted, with a follow-up carried out over 1 year. RESULTS: High-degree atrioventricular block occurred in 22 (11%) patients. In univariate analysis, high-degree atrioventricular block was associated with first-degree heart block at admission (odds ratio 3.1; P=0.015), periannular complication on echocardiography (odds ratio 6.9; P<0.001) and severe biological inflammatory syndrome, notably C-reactive protein (127 vs 90mg/L; P=0.011). In-hospital mortality (12.7%) was higher in patients with high-degree atrioventricular block (odds ratio 4.0; P=0.011) in univariate analysis. Of the 16 patients implanted with a permanent pacemaker for high-degree atrioventricular block and interrogated, only four (25%) were dependent on the pacing function at 1-year follow-up. CONCLUSIONS: High-degree atrioventricular block is associated with high inflammation markers and periannular complications, especially if first-degree heart block is identified at admission. High-degree atrioventricular block is a marker of infectious severity, and tends to raise the in-hospital mortality rate. Systematic assessment of patients admitted for infective endocarditis suspicion, considering these contributing factors, could indicate intensive care unit monitoring or even temporary pacemaker implantation in those at highest risk.


Asunto(s)
Válvula Aórtica , Bloqueo Atrioventricular , Mortalidad Hospitalaria , Marcapaso Artificial , Humanos , Masculino , Femenino , Bloqueo Atrioventricular/fisiopatología , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/terapia , Bloqueo Atrioventricular/mortalidad , Persona de Mediana Edad , Anciano , Factores de Riesgo , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/microbiología , Factores de Tiempo , Endocarditis/mortalidad , Endocarditis/diagnóstico , Endocarditis/complicaciones , Estimulación Cardíaca Artificial , Estudios Retrospectivos , Adulto , Medición de Riesgo , Electrocardiografía , Frecuencia Cardíaca , Anciano de 80 o más Años , Sistema de Conducción Cardíaco/fisiopatología
14.
Arch Cardiovasc Dis ; 117(6-7): 450-456, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38677940

RESUMEN

In France, mexiletine - a class I antiarrhythmic drug - can be prescribed for the symptomatic treatment of myotonia of the skeletal muscles in adult patients with myotonic dystrophy under a compassionate use programme. Mexiletine is used according to its summary of product characteristics, which describes its use for myotonia treatment in adult patients with non-dystrophic myotonia, a different neuromuscular condition without cardiac involvement. A cardiac assessment is required prior to initiation and throughout treatment due to potential proarrhythmic effects. The presence of conduction system disease, the most common cardiac manifestation of myotonic dystrophy, mandates repeated cardiac evaluations in patients with this condition, and becomes even more important when they are given mexiletine. A group of experts, including three neurologists and five cardiologists from French neuromuscular reference centres, were involved in a task force to develop a treatment algorithm to guide mexiletine use in myotonic dystrophy. The recommendations are based on data from a literature review of the safety of mexiletine-treated patients with myotonic dystrophy, the compassionate use protocol for mexiletine and the personal clinical experience of the experts. The main conclusion of the expert group is that, although existing safety data in mexiletine-treated patients with myotonic dystrophy are reassuring, cardiac assessments should be reinforced in such patients compared with mexiletine-treated patients with non-dystrophic myotonia. This expert opinion to guide mexiletine treatment in patients with myotonic dystrophy should help to reduce the risk of severe adverse events and facilitate interactions between specialists involved in the routine care of patients with myotonic dystrophy.


Asunto(s)
Mexiletine , Distrofia Miotónica , Adulto , Humanos , Algoritmos , Antiarrítmicos/uso terapéutico , Antiarrítmicos/efectos adversos , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiología , Arritmias Cardíacas/inducido químicamente , Toma de Decisiones Clínicas , Ensayos de Uso Compasivo , Consenso , Francia , Mexiletine/uso terapéutico , Mexiletine/efectos adversos , Distrofia Miotónica/tratamiento farmacológico , Distrofia Miotónica/diagnóstico , Distrofia Miotónica/fisiopatología , Medición de Riesgo , Factores de Riesgo , Resultado del Tratamiento , Bloqueadores del Canal de Sodio Activado por Voltaje/uso terapéutico , Bloqueadores del Canal de Sodio Activado por Voltaje/efectos adversos
15.
Front Cardiovasc Med ; 11: 1361761, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38572304

RESUMEN

Background and aims: Right phrenic nerve palsy is the most frequent complication of cryoballoon procedures. The SMARTFREEZE™ console (Boston Scientific, St. Paul, MN, USA) has integrated a new tool for diaphragm monitoring-the Diaphragm Movement Sensor; however, it has not been evaluated in clinical practice. We aimed to assess the diagnostic performance of the Diaphragm Movement Sensor based on compound motor action potential data recorded simultaneously. Methods: Thirty consecutive patients (mean age 63.2 ± 10.2 years) were included. We simultaneously recorded the compound motor action potential and the Diaphragm Movement Sensor during cryoapplications in the right pulmonary veins. The right phrenic nerve was paced at 60 per minute, 12 V and 2.9 ms. Compound motor action potential monitoring with a 30% decrease cutoff for the diagnosis of phrenic nerve threatening was considered the gold standard. The Diaphragm Movement Sensor decrease threshold was also set at 30%. Results: Considering compound motor action potential monitoring, phrenic nerve threatening occurred 11 times (in seven patients) among 84 cryoapplications (13.1%) at the right pulmonary veins. The sensitivity and specificity of the Diaphragm Movement Sensor were, respectively, 33% (95% CI: 7%-70%) and 49% (95% CI: 38%-61%; P < 0.001). The predictive positive and negative values for the Diaphragm Movement Sensor were, respectively, 7% (95% CI: 2%-20%) and 86% (95% CI: 72%-95%). The Diaphragm Movement Sensor gave an erroneous diagnosis in 44/84 cryoapplications (52.4%). Conclusions: The diagnostic performance of the Diaphragm Movement Sensor is low, and the relevance of its use in clinical practice may be debated.

16.
Mayo Clin Proc ; 99(5): 754-765, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38180394

RESUMEN

OBJECTIVE: To compare outcomes after left atrial appendage occlusion (LAAO) via implanted device vs no LAAO in a matched cohort of patients with atrial fibrillation (AF). METHODS: This longitudinal retrospective cohort study was based on the national database covering hospital care for the entire French population. Adults (≥18 years of age) who had been hospitalized with AF (January 1, 2015, to January 1, 2020) who underwent LAAO were identified. Propensity score matching was used to control for potential confounders of the treatment-outcome relationship. The primary outcome was a composite of ischemic stroke, major bleeding, or all-cause death during follow-up. RESULTS: After propensity score matching, 1216 patients with AF who were treated with LAAO were matched with 1216 controls (patients AF who were not treated with LAAO). Mean follow-up was 14.5 months (median, 13 months; IQR, 7-21 months). Patients with LAAO had a lower risk of the composite outcome (HR, 0.48; 95% CI, 0.42 to 0.55). Total events (309 for LAAO vs 640 for controls) and event rates (23.3% vs 44.0%/year, respectively) were lower for LAAO, driven primarily by a decreased risk of all-cause death (HR, 0.39; 95% CI, 0.33 to 0.46; P<.0001), whereas ischemic stroke risk was higher (HR, 1.75; 95% CI, 1.17 to 2.64). Significant interactions were observed in subgroups with a history of ischemic stroke (P<.001) and of bleeding (P=.002). CONCLUSION: Among AF patients at high bleeding risk, our nationwide study highlights a high risk of clinical events during follow-up. LAAO appeared less effective than no LAAO in preventing stroke but more effective in preventing death. Left atrial appendage occlusion is particularly effective in patients with previous ischemic stroke or any episode of bleeding.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Humanos , Fibrilación Atrial/cirugía , Apéndice Atrial/cirugía , Masculino , Femenino , Anciano , Estudios Retrospectivos , Puntaje de Propensión , Estudios Longitudinales , Persona de Mediana Edad , Resultado del Tratamiento , Dispositivo Oclusor Septal , Accidente Cerebrovascular Isquémico/prevención & control , Accidente Cerebrovascular Isquémico/etiología , Accidente Cerebrovascular Isquémico/epidemiología , Anciano de 80 o más Años , Francia/epidemiología
18.
J Clin Endocrinol Metab ; 109(2): 549-556, 2024 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-37602721

RESUMEN

CONTEXT: Familial hypocalciuric hypercalcemia type 1 (FHH-1) defines an autosomal dominant disease, related to mutations in the CASR gene, with mild hypercalcemia in most cases. Cases of FHH-1 with a short QT interval have not been reported to date. OBJECTIVE: Three family members presented with FHH-1 and short QT interval (<360 ms), a condition that could lead to cardiac arrhythmias, and the effects of cinacalcet, an allosteric modulator of the CaSR, in rectifying the abnormal sensitivity of the mutant CaSR and in correcting the short QT interval were determined. METHODS: CASR mutational analysis was performed by next-generation sequencing and functional consequences of the identified CaSR variant (p.Ile555Thr), and effects of cinacalcet were assessed in HEK293 cells expressing wild-type and variant CaSRs. A cinacalcet test consisting of administration of 30 mg cinacalcet (8 Am) followed by hourly measurement of serum calcium, phosphate, and parathyroid hormone during 8 hours and an electrocardiogram was performed. RESULTS: The CaSR variant (p.Ile555Thr) was confirmed in all 3 FHH-1 patients and was shown to be associated with a loss of function that was ameliorated by cinacalcet. Cinacalcet decreased parathyroid hormone by >50% within two hours, and decreases in serum calcium and increases in serum phosphate occurred within 8 hours, with rectification of the QT interval, which remained normal after 3 months of cinacalcet treatment. CONCLUSION: Our results indicate that FHH-1 patients should be assessed for a short QT interval and a cinacalcet test used to select patients who are likely to benefit from this treatment.


Asunto(s)
Hipercalcemia , Hiperparatiroidismo , Humanos , Hipercalcemia/tratamiento farmacológico , Hipercalcemia/genética , Cinacalcet/uso terapéutico , Calcio , Células HEK293 , Mutación , Hormona Paratiroidea , Fosfatos , Receptores Sensibles al Calcio/genética
19.
Arch Cardiovasc Dis ; 116(12): 572-579, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37953189

RESUMEN

BACKGROUND: Implantable cardioverter-defibrillators reduce mortality, but the electric shocks delivered can impact the patient's quality of life. Patient education is an efficient way to reduce the stress related to both the device and the disease. AIMS: We assessed the evolution of knowledge and satisfaction of implantable cardioverter-defibrillator recipients regarding their cardiac disease, implantable cardioverter-defibrillator implantation, follow-up complications, remote monitoring and daily life recommendations. Quality of life, implantable cardioverter-defibrillator-related stress levels and remote monitoring benefits were also evaluated. METHODS: A self-administered questionnaire of 43 items was published on the French Association of Cardiac Electrical Device Wearers (APODEC) website and sent to registered patients. RESULTS: Overall, 330 patients completed the survey. Physicians were the patients' principal information source regarding their cardiac disease (86.7%) and implantable cardioverter-defibrillator (93.3%), and 90% looked for further information after the procedure, mainly on websites (78.8%). More than half of the patients were not sufficiently informed about implantable cardioverter-defibrillators before implantation (61.2%). In the patients' opinion, the best sources of further information were their physician (81.8%), patient associations (63.6%) and the Internet (45.8%). Although patient knowledge increased during follow-up, their knowledge could be improved regarding daily life with an implantable cardioverter-defibrillator (52.1%), remote monitoring (34.2%) and their cardiac disease (32.1%). Remote monitoring follow-up was used by 92.1% of patients and mostly improved their peace of mind (67.8%). Implantable cardioverter-defibrillator shocks were associated with major stress for patients receiving them (46.6%). CONCLUSION: These findings highlight the lack of information provided to implantable cardioverter-defibrillator recipients before implantation, a concerning issue to be addressed in the near future.


Asunto(s)
Desfibriladores Implantables , Cardiopatías , Humanos , Estudios de Seguimiento , Calidad de Vida , Encuestas y Cuestionarios , Muerte Súbita Cardíaca
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA