Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39317656

RESUMEN

BACKGROUND: Electrical Storm (ES) is a life-threatening condition requiring a rapid management. Percutaneous Stellate Ganglion Block (PSGB) proved to be safe and effective on top of standard therapy, but no data are available about its early use. METHODS: We considered all patients enrolled from 1st July 2017 to 30th April 2024 in the STAR registry (STellate ganglion block for Arrhythmic stoRm), a multicentre, international, observational, prospective registry. We aimed to assess the effectiveness of the first PSGB only. Patients were divided into two groups depending on whether they received PSGB before (Early-PSGB, often due to AAD contraindication) or after (Delayed-PSGB) intravenous antiarrhythmic drugs (AADs other than beta-blockers). RESULTS: We considered 180 PSGB (26 Early-PSGB and 154 AAD-first). In the early-PSGB group we observed a statistically significant reduction of treated arrhythmic events in the hour after PSGB compared to the hour before: 0 (0-0) vs 4.5 (1-10), p<0.001 and the extent of the reduction was similar in the Early-PSGB and delayed-PSGB group [-4.5 (-7 to -2) vs. -2.5 (-3.5 to -1.5), p=ns]. The percentage of patients free from arrhythmias was similar in the two groups up to 12 hours after PSGB (81%vs 84%, p=0.6 after one hour; 77% vs 79%, p=0.8 at three hours and 65% vs 69%, p= 0.7 after 12 hours). CONCLUSIONS: PSGB proved to be effective also when used early in the treatment of ES. Due to its rapidity of action, our results may suggest its early use to reduce the number of defibrillations and possibly to reduce the likelihood of a refractory ES.

2.
ESC Heart Fail ; 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39091044

RESUMEN

AIMS: The indication for implantable cardioverter defibrillator (ICD) for sudden cardiac death (SCD) prevention relies mostly on left ventricular ejection fraction (LVEF) ≤ 35%. The use of a wearable cardioverter defibrillator (WCD) in the case of dynamic alterations of LVEF may help avoid an improper early ICD implant when a favourable evolution in the post-acute phase is observed and may help reduce costs. METHODS: This parallel cohort retrospective study included patients with heart failure with reduced ejection fraction (HFrEF) at high risk of arrhythmias recruited in the acute phase and divided into an early ICD cohort and a WCD cohort for primary prevention during the waiting period established by European Society of Cardiology guidelines. RESULTS: A total of 41 consecutive patients were enrolled: 26 in the WCD group and 15 in the early ICD group. Age, LVEF at baseline, causes of HFrEF and drug therapy in the two cohorts were similar. During the waiting period after the inclusion, three patients (11.5%) in the WCD cohort and four (26.7%) in the early ICD cohort developed relevant ventricular arrhythmias (P = 0.22); none of them had subsequent LVEF recovery. At the end of the waiting period, 13 patients (50%) in the WCD group and 7 (46.7%) in the early ICD group experienced LVEF recovery (P = 0.84). The average cost per patient at the end of the waiting period was €23 934 in the early ICD cohort versus €19 167 in the WCD cohort (-19.9%). This cost savings from WCD use appears even higher when projected over a 10 year period (-41.2%). CONCLUSIONS: WCD may represent a cost-effective strategy to more accurately select candidates for the primary prevention ICD implant among high-risk patients with HFrEF. ICD use provides effective protection from SCD and reduces costs compared with an extensive early ICD implant.

3.
Artículo en Inglés | MEDLINE | ID: mdl-38972960

RESUMEN

BACKGROUND: The combination of highly localized impedance (LI) and contact force (CF) may improve tissue characterization and lesion prediction during radiofrequency (RF) pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). OBJECTIVE: We report the outcomes of our acute and long-term clinical evaluation of CF-LI-guided PVI in consecutive AF ablation cases from an international multicenter clinical setting. METHODS: Three hundred twenty-four consecutive patients from 20 European centers undergoing RF catheter ablation with the Stablepoint™ catheter were enrolled in the CHARISMA registry. Of these, 275 had a minimum follow-up of 1 year and were included in the primary analysis. RESULTS: The mean procedure duration was 115 ± 47 min, and the mean fluoroscopy time was 9.9 ± 6 min. At the end of the procedures, all PVs had been successfully isolated in all study patients. Minor complications were reported in 12 patients (4.4%). At 1 year, 36 (13.1%) patients had had an AF recurrence, and freedom from antiarrhythmic drugs and AF recurrence was achieved in 228 (82.9%) patients. The recurrence rate was higher in patients with persistent AF (21/116, 18.1%) than in those with paroxysmal AF (15/159, 9.4%; p = 0.0459). On multivariate logistic analysis adjusted for baseline confounders, only time > 6 months from first diagnosis of AF to ablation (HR = 2.93, 95%CI 1.03 to 8.36, p = 0.0459) was independently associated with recurrences. CONCLUSION: An ablation strategy for PVI guided by CF-LI technology proved safe and effective and resulted in a low recurrence rate of AF over 1-year follow-up, irrespective of the underlying AF type. CLINICAL TRIAL REGISTRATION: Catheter Ablation of Arrhythmias with a High-Density Mapping System in Real-World Practice. (CHARISMA). URL: http://clinicaltrials.gov/ Identifier: NCT03793998.

4.
Int J Cardiol ; 413: 132385, 2024 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-39032577

RESUMEN

BACKGROUND: The H2FPEF and the HFA-PEFF scores have become useful tools to diagnose heart failure with preserved ejection fraction (HFpEF). Their accuracy in patients with a history of atrial fibrillation (AF) is less known. This study evaluates the association of these scores with invasive left atrial pressure (LAP) and the additional value of cardiac measures. METHODS: This is a multicenter observational prospective study involving patients undergoing ablation of AF. Patients with left ventricular ejection fraction (LVEF) < 40%, congenital cardiopathy, any severe cardiac valve disease and prosthetic valves were excluded. Elevated filling pressure was defined as a mean LAP ≥15 mmHg. RESULTS: A total of 135 patients were enrolled in the study (mean age 65.2 ± 9.1 years, 32% female, mean LVEF 56.9 ± 7.9%). Patients with H2FPEF ≥ 6 or HFA-PEFF ≥5 had higher values of NTproBNP and more impaired cardiac function. However, neither H2FPEF nor HFA-PEFF score showed a meaningful association with elevated mean LAP (respectively, OR 1.05 [95%CI 0.83-1.34] p = 0.64, and OR 1.09 [95%CI: 0.86-1.39] p = 0.45). The addition of LA indexed minimal volume (LAVi min) improved the ability of the scores (baseline C-statistic 0.51 [95%CI 0.41-0.61] for the H2FPEF score and 0.53 [95%CI 0.43-0.64] for the HFA-PEFF score) to diagnose elevated filling pressure (H2FPEF + LAVi min: C-statistic 0.70 [95%CI 0.60-0.80], p-value = 0.005; HFA-PEFF + LAVi min: C-statistic 0.70 [95%CI 0.60-0.80], p-value = 0.02). CONCLUSION: In a cohort of patients with a history of AF, the use of the available diagnostic scores did not predict elevated mean LAP. The integration of LAVi min improved the ability to correctly identify elevated filling pressure.


Asunto(s)
Fibrilación Atrial , Volumen Sistólico , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/diagnóstico , Estudios Prospectivos , Volumen Sistólico/fisiología , Función Ventricular Izquierda/fisiología
5.
Artículo en Inglés | MEDLINE | ID: mdl-38850280

RESUMEN

INTRODUCTION: Closed Loop Stimulation (CLS) is a rate-responsive algorithm that adjusts heart rate (HR) based on changes in intracardiac impedance measured from the right ventricle lead. However, the use of CLS in conduction system pacing has not been investigated. In this retrospective study, we aimed to assess whether CLS with left bundle branch area pacing (LBBAP) can generate an appropriate distribution of HR in daily life. METHODS AND RESULTS: Our study included 24 patients with CLS pacing and chronotropic incompetence, comparing them with 19 patients receiving DDD pacing, all with LBBAP. Cumulative HR distribution charts were generated using data from a single device interrogation with a minimum follow-up period of 30 days. In DDD-CLS mode, there was a higher percentage of atrial pacing compared to DDD mode (median 58% [interquartile range 29%-83%] vs. 13% [10%-26%], p = .001), and CLS-paced beats were present across all frequency bins. The distribution of beats between the groups was similar (p = .643), resulting in comparable mean HR (72 bpm [70-77] vs. 73 bpm [65-75], p = .615). CONCLUSIONS: In the context of LBBAP, CLS effectively modulates pacing rates over a wide frequency range. This lead position does not adversely affect the rate-responsive performance of the algorithm.

6.
J Cardiovasc Med (Hagerstown) ; 25(6): 450-456, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38625833

RESUMEN

BACKGROUND: Atrioventricular block (AVB) is a frequent complication in patients undergoing transcatheter aortic valve implantation (TAVI). Right apex ventricular pacing (RVP) represents the standard treatment but may induce cardiomyopathy over the long term. Left bundle branch area pacing (LBBAP) is a promising alternative, minimizing the risk of desynchrony. However, available evidence with LBBAP after TAVI is still low. OBJECTIVE: To assess the feasibility and safety of LBBAP for AVB post-TAVI compared with RVP. METHODS: Consecutive patients developing AVB early after TAVI were enrolled between 1 January 2022 and 31 December 2022 at three high-volume hospitals and received LBBAP or RVP. Data on procedure and at short-term follow-up (at least 3 months) were collected. RESULTS: A total of 38 patients (61% men, mean age 83 ±â€Š6 years) were included; 20 patients (53%) received LBBAP. Procedural success was obtained in all patients according to chosen pacing strategy. Electrical pacing performance at implant and after a mean follow-up of 4.2 ±â€Š2.8 months was clinically equivalent for both pacing modalities. In the LBBAP group, procedural time was longer (70 ±â€Š17 versus 58 ±â€Š15 min in the RVP group, P  = 0.02) and paced QRS was shorter (120 ±â€Š19 versus 155 ±â€Š12 ms at implant, P  < 0.001; 119 ±â€Š18 versus 157 ±â€Š9 ms at follow-up, P  < 0.001). Complication rates did not differ between the two groups. CONCLUSION: In patients with AVB after TAVI, LBBAP is feasible and safe, resulting in a narrow QRS duration, either acutely and during the follow-up, compared with RVP. Further studies are needed to evaluate if LBBAP reduces pacing-induced cardiomyopathy in this clinical setting.


Asunto(s)
Estenosis de la Válvula Aórtica , Bloqueo Atrioventricular , Fascículo Atrioventricular , Estimulación Cardíaca Artificial , Estudios de Factibilidad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Femenino , Anciano de 80 o más Años , Anciano , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/terapia , Bloqueo Atrioventricular/fisiopatología , Bloqueo Atrioventricular/diagnóstico , Resultado del Tratamiento , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Fascículo Atrioventricular/fisiopatología , Factores de Tiempo , Letonia , Factores de Riesgo , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Frecuencia Cardíaca
7.
J Clin Med ; 13(8)2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38673430

RESUMEN

Objectives: Conduction system pacing (CSP) and atrioventricular junction ablation (AVJA) improve the outcomes in patients with symptomatic, refractory atrial fibrillation (AF). In this setting, AVJA can be performed simultaneously with implantation or in a second procedure a few weeks after implantation. Comparison data on these two alternative strategies are lacking. Methods: A prospective, multicentre, observational study enrolled consecutive patients with symptomatic, refractory AF undergoing CSP and AVJA performed in a single procedure or in two separate procedures. Data on the long-term outcomes and healthcare resource utilization were prospectively collected. Results: A total of 147 patients were enrolled: for 105 patients, CSP implantation and AVJA were performed simultaneously (concomitant AVJA); in 42, AVJA was performed in a second procedure, with a mean of 28.8 ± 19.3 days from implantation (delayed AVJA). After a mean follow-up of 12 months, the rate of procedure-related complications was similar in both groups (3.8% vs. 2.4%; p = 0.666). Concomitant AVJA was associated with a lower number of procedure-related hospitalizations per patient (1.0 ± 0.1 vs. 2.0 ± 0.3; p < 0.001) and with a lower number of hospital treatment days per patient (4.7 ± 1.8 vs. 7.4 ± 1.9; p < 0.001). Conclusions: Concomitant AVJA resulted as being as safe as delayed AVJA and was associated with a lower utilization of healthcare resources.

8.
Heart Rhythm ; 21(6): 874-880, 2024 06.
Artículo en Inglés | MEDLINE | ID: mdl-38428448

RESUMEN

BACKGROUND: Cardiac resynchronization therapy (CRT) with biventricular pacing (BVP) is a well-established therapy in patients with reduced left ventricular ejection fraction, heart failure, and left bundle branch block. Left bundle branch area pacing (LBBAP) has recently been shown to be a feasible and effective alternative to BVP. Comparative data on the risk of complications between LBBAP and BVP among patients undergoing CRT are lacking. OBJECTIVE: The aim of this study was to compare the long-term risk of procedure-related complications between LBBAP and BVP in a cohort of patients undergoing CRT. METHODS: This prospective, multicenter, observational study enrolled 668 consecutive patients (mean age 71.2 ± 10.0 years; 52.2% male; 59.4% with New York Heart Association class III-IV heart failure symptoms) with left ventricular ejection fraction 33.4% ± 4.3% who underwent BVP (n = 561) or LBBAP (n = 107) for a class I or II indication for CRT. Propensity score matching for baseline characteristics yielded 93 matched pairs. The rate and nature of intraprocedural and long-term post-procedural complications occurring during follow-up were prospectively collected and compared between the 2 groups. RESULTS: During a mean follow-up of 18 months, procedure-related complications were observed in 16 patients: 12 in BVP (12.9%) and 4 in LBBAP (4.3%) (P = .036). Compared with patients who underwent LBBAP, those who underwent BVP showed a lower complication-free survival (P = .032). In multivariate analysis, BVP resulted an independent predictive factor associated with a higher risk of complications (hazard ratio 3.234; P = .042). Complications related to the coronary sinus lead were most frequently observed in patients who underwent BVP (50.0% of all complications). CONCLUSION: LBBAP was associated with a lower long-term risk of device-related complications compared with BVP in patients with an indication for CRT.


Asunto(s)
Bloqueo de Rama , Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Puntaje de Propensión , Sistema de Registros , Volumen Sistólico , Humanos , Masculino , Femenino , Anciano , Terapia de Resincronización Cardíaca/métodos , Terapia de Resincronización Cardíaca/efectos adversos , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/fisiopatología , Estudios Prospectivos , Bloqueo de Rama/terapia , Bloqueo de Rama/fisiopatología , Volumen Sistólico/fisiología , Resultado del Tratamiento , Fascículo Atrioventricular/fisiopatología , Estudios de Seguimiento , Función Ventricular Izquierda/fisiología
9.
J Cardiovasc Electrophysiol ; 35(5): 942-949, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38462681

RESUMEN

INTRODUCTION: Mapping system is useful in ablation of atrioventricular nodal reentry tachycardia (AVNRT) and localization of anatomic variances. Voltage mapping identifies a low voltage area in the Koch triangle called low-voltage-bridge (LVB); propagation mapping identifies the collision point (CP) of atrial wavefront convergence. We conducted a prospective study to evaluate the relationship between LVB and CP with successful site of ablation and identify standard value for LVB. MATERIALS AND METHODS: Three-dimensional (3D) maps of the right atria were constructed from intracardiac recordings using the ablation catheter. Cut-off values on voltage map were adjusted until LVB was observed. On propagation map, atrial wavefronts during sinus rhythm collide in the site representing CP, indicating the area of slow pathway conduction. Ablation site was selected targeting LVB and CP site, confirmed by anatomic position on fluoroscopy and atrioventricular ratio. RESULTS: Twenty-seven consecutive patients were included. LVB and CP were present in all patients. Postprocedural evaluation identified standard cut-off of 0.3-1 mV useful for LVB identification. An overlap between LVB and CP was observed in 23 (85%) patients. Procedure success was achieved in all patient with effective site at first application in 22 (81%) patients. There was a significant correlation between LVB, CP, and the site of effective ablation (p = .001). CONCLUSION: We found correlation between LVB and CP with the site of effective ablation, identifying a voltage range useful for standardized LVB identification. These techniques could be useful to identify ablation site and minimize radiation exposure.


Asunto(s)
Potenciales de Acción , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca , Taquicardia por Reentrada en el Nodo Atrioventricular , Humanos , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatología , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Masculino , Femenino , Estudios Prospectivos , Persona de Mediana Edad , Resultado del Tratamiento , Adulto , Valor Predictivo de las Pruebas , Anciano , Nodo Atrioventricular/fisiopatología , Nodo Atrioventricular/cirugía , Factores de Tiempo
10.
Eur Heart J ; 45(10): 823-833, 2024 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-38289867

RESUMEN

BACKGROUND AND AIMS: An electrical storm (ES) is a clinical emergency with a paucity of established treatment options. Despite initial encouraging reports about the safety and effectiveness of percutaneous stellate ganglion block (PSGB), many questions remained unsettled and evidence from a prospective multicentre study was still lacking. For these purposes, the STAR study was designed. METHODS: This is a multicentre observational study enrolling patients suffering from an ES refractory to standard treatment from 1 July 2017 to 30 June 2023. The primary outcome was the reduction of treated arrhythmic events by at least 50% comparing the 12 h following PSGB with the 12 h before the procedure. STAR operators were specifically trained to both the anterior anatomical and the lateral ultrasound-guided approach. RESULTS: A total of 131 patients from 19 centres were enrolled and underwent 184 PSGBs. Patients were mainly male (83.2%) with a median age of 68 (63.8-69.2) years and a depressed left ventricular ejection fraction (25.0 ± 12.3%). The primary outcome was reached in 92% of patients, and the median reduction of arrhythmic episodes between 12 h before and after PSGB was 100% (interquartile range -100% to -92.3%). Arrhythmic episodes requiring treatment were significantly reduced comparing 12 h before the first PSGB with 12 h after the last procedure [six (3-15.8) vs. 0 (0-1), P < .0001] and comparing 1 h before with 1 h after each procedure [2 (0-6) vs. 0 (0-0), P < .001]. One major complication occurred (0.5%). CONCLUSIONS: The findings of this large, prospective, multicentre study provide evidence in favour of the effectiveness and safety of PSGB for the treatment of refractory ES.


Asunto(s)
Taquicardia Ventricular , Anciano , Femenino , Humanos , Masculino , Estudios Prospectivos , Ganglio Estrellado , Volumen Sistólico , Taquicardia Ventricular/terapia , Taquicardia Ventricular/etiología , Resultado del Tratamiento , Fibrilación Ventricular/etiología , Función Ventricular Izquierda , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA