Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
Cornea ; 43(9): 1162-1164, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38692706

RESUMEN

PURPOSE: The purpose of this study was to report the first remote telesurgery in a case of epithelial basement membrane disease with recurrent corneal erosions. METHODS: Topography-guided transepithelial photorefractive combined phototherapeutic keratectomy (PRK-PTK) is a surgical option that treats corneal irregularities and prevents the recurrences of erosions while treating the refractive error. RESULTS: We performed for the first time a remote transepithelial topography-guided combined PRK-PTK using the iRes®2 excimer laser platform (iVIS Technologies, Taranto, Italy), with the surgeon sitting in his own room and controlling the excimer laser in remote with 5G connection through the Remote Control Station and the patient in the operating room. At one-month post-operative, visual acuity was 20/20 and the patient's symptoms subsided. CONCLUSIONS: Our surgery opens the era of telesurgery in the corneal panorama.


Asunto(s)
Topografía de la Córnea , Láseres de Excímeros , Queratectomía Fotorrefractiva , Agudeza Visual , Humanos , Queratectomía Fotorrefractiva/métodos , Láseres de Excímeros/uso terapéutico , Agudeza Visual/fisiología , Masculino , Epitelio Corneal/cirugía , Telemedicina , Cirugía Asistida por Computador/métodos , Persona de Mediana Edad
2.
Front Med (Lausanne) ; 10: 1276502, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38076261

RESUMEN

Introduction: Inverted Internal Limiting Membrane (ILM)-flap technique demonstrated its effectiveness, in terms of anatomical closure rate and visual acuity recovery for high myopic macular holes. We evaluated macular function after a successful inverted ILM-flap for macular holes in high myopic eyes (hMMH) using microperimetry to predict visual prognosis. Methods: A retrospective study on 23 eyes of 23 patients after surgical closure of hMMH, was performed. All patients underwent inverted ILM-flap and gas tamponade. Cataract surgery was performed in phakic eyes. Study outcomes including best-corrected visual acuity (BCVA), retinal sensitivity (RS) at central 12°, central retinal sensitivity (CRS) at central 4° and mean deviation (MD), and fixation behavior as bivariate contour ellipse area (BCEA, degrees2) measured by microperimetry, were evaluated over 6 months. A mixed-effects model was used to evaluate and compare the repeated measurements of outcomes between phakic and pseudophakic eyes. A regression model was performed to assess the relationship between BCVA at 6 months and independent variables. Results: Overall mean BCVA improved from 0.98 ± 0.21 logMAR at baseline to 0.47 ± 0.31 logMAR at the last follow-up (p < 0.001). Over 6 months, overall sensitivity measurements improved (RS, p = 0.001; CRS, p < 0.0001; MD, p = 0.03), and the BCEA decreased in dimension, although not significantly (p ≥ 0.05). The mixed model revealed a significantly better effect of inverted ILM-flap combined with cataract surgery on BCVA and CRS in phakic eyes than inverted ILM-flap alone in pseudophakic ones. The regression model revealed a relationship of 6-month BCVA with pre-operative BCVA (ß = 0.60, p = 0.02) and RS (ß = -0.03, p = 0.01). Conclusion: The inverted ILM-flap technique significantly improved visual acuity and retinal sensitivity after the hMMH closure, particularly when combined with cataract extraction. Pre-operative visual acuity and retinal sensitivity at central 12° may predict post-surgical visual acuity.

3.
J Clin Med ; 12(16)2023 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-37629230

RESUMEN

BACKGROUND: Microperimetric biofeedback training improved visual acuity and fixation stability in patients who previously underwent macular surgery. We aimed to compare the functional results of biofeedback training with the standard of care in patients who underwent successful inverted Internal Limiting Membrane (ILM)-flap technique for high myopic macular holes (hMMH). METHODS: This was a retrospective, comparative, cohort study. Patients with hMMH after surgical hole closure underwent microperimetric biofeedback using structured light stimulus plus acoustic tone (n = 12; Biofeedback) or standard of care with scheduled visits (n = 11; Control). Best-corrected visual acuity, retinal sensitivity at central 12° (RS) and 4° (CRS) with a mean deviation at central 12° (MD), and fixation stability as bivariate contour ellipse area (BCEA 68%, 95%, and 99%) were assessed at baseline and month 1, 3, 6, and 12. The Mann-Whitney test was used to test the difference between the groups. RESULTS: Baseline functional parameters were not significantly different among the groups. BCVA significantly improved in each group (Biofeedback, p = 0.002; Control, p ≤ 0.02) at all follow-up visits. CRS significantly improved at 6 (p = 0.03) and 12 (p = 0.01) months in the Biofeedback group and at month 12 (p = 0.01) in the Control group. RS (p = 0.001) and MD (p = 0.005) improved at the last follow-up only in the trained group. After training, BCEA 68% and 95% significantly improved (6 and 12 months, p < 0.05). The Biofeedback group had better results in RS (p ≤ 0.02), CRS (p ≤ 0.02), and BCEA 68%, 95%, and 99% (p ≤ 0.01) compared to the Control at all follow-ups. BCVA and MD were better in the Biofeedback group at month 3 (p = 0.01), and month 3 (p = 0.01) and 12 (p = 0.003), respectively. CONCLUSIONS: Microperimetric biofeedback can increase retinal sensitivity and stabilize fixation better than the standard care over months after a successful inverted ILM-flap for hMMH.

4.
Int J Dent ; 2021: 6676158, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34035815

RESUMEN

BACKGROUND: Recent clinical guidelines have extended indications for oral appliances to subjects affected by moderate-to-severe obstructive sleep apnoea (OSA). The aim of this systematic review covering this important issue for public health is twofold: updating and summarizing the best available scientific evidence by selecting RCTs of quality only, and identifying the therapeutic pathways that can be transferred to the current clinical practice. METHODS: All the abstracts which were published before February 18, 2019, have been identified in three electronic databases (PubMed, Web of Science, and Cochrane). The Cochrane Collaboration's tool for assessing risk of bias was used as an assessment tool in order to evaluate the quality of the selected studies. RESULTS: The search strategy yielded 2,260 studies. After removing duplicates and studies that did not comply with the inclusion criteria, 32 full-text articles were assessed for eligibility, and 17 RCTs were finally included in the qualitative synthesis. The 17 selected studies were very heterogeneous in the type of included RCTs in terms of patient inclusion criteria, sample size, distribution of the two genders in the various groups, duration of treatment, and definition of primary and secondary outcomes, without any restriction on the definition of the control group. A common finding was the positive responsiveness of oral appliance treatment in subjects affected by mild-to-moderate OSA with some evidence for cases of severe OSA. CONCLUSION: Higher-quality studies are needed in order to provide additional useful guidelines for dental clinicians for OSA management.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA