Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Eur J Prosthodont Restor Dent ; 31(4): 321-331, 2023 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-37194583

RESUMEN

INTRODUCTION AND OBJECTIVES: CAD/CAM prostheses may be produced in prosthetic laboratories or directly by practitioners. Quality of ceramic polishing procedures is a controversial topic and it would be interesting for practitioners working with CAD/CAM devices to determine which method is the most efficient regarding finishing and polishing. This systematic review aims to evaluate the impact of different finishing and polishing procedures on the surface of milled ceramics. MATERIALS AND METHODS: A precise request was launched on the PubMed database. Studies included if they met the criteria of a specifically prepared PICO search. A first selection was performed by analysing titles and abstracts: the articles presenting a study conducted on non-CAD/CAM milled ceramics and research not containing comparisons of finishing procedures were not included. Roughness was evaluated in 15 articles. Nine papers recommended mechanical polishing over glazing regardless of the type of ceramic used. However, no significant differences were detected between the surface roughness of glazed and polished ceramics in nine other publications. CONCLUSIONS: there is no scientific evidence demonstrating the superiority of hand polishing over glazing on CAD/CAM-milled ceramics.


Asunto(s)
Pulido Dental , Porcelana Dental , Ensayo de Materiales , Pulido Dental/métodos , Propiedades de Superficie , Cerámica , Diseño Asistido por Computadora
2.
Arch Oral Biol ; 140: 105452, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35594696

RESUMEN

OBJECTIVE: This work describes and compares the root and root canal morphology of a medieval population dating from the 8th to 10th century from the southwest of France, and a current French population. DESIGN: The root morphology of 579 teeth from 70 medieval individuals was analyzed using cone beam computed tomography, and compared with 690 teeth from a current French population of 329 individuals. The Vertucci classification was used to describe the root canal configuration. RESULTS: In the medieval population, the maxillary first premolar usually had one root. In contrast, in the current population this tooth predominantly had two roots, and the three-root form had appeared. Mandibular canine with two roots was observed in 5.7% of cases, and in the current population this form was found in 1.6% but the difference was not significative. The greatest variability between the two populations in terms of root canal configuration was in one-rooted maxillary first and second premolars, the mandibular canines, and the distal roots of the mandibular first molars. Differences in root numbers and canal configurations of the maxillary molars investigated among the two populations were not significant. CONCLUSIONS: This study indicated that the upper first premolar of the current population tended to have more than one root, while this tooth type of the medieval group mostly appeared with only one. For the root canal configuration, studies in the upper premolars, lower canines and first molars of the current population apparently revealed a significant simplification compared with the ancient group.


Asunto(s)
Cavidad Pulpar , Raíz del Diente , Diente Premolar/anatomía & histología , Diente Premolar/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico/métodos , Cavidad Pulpar/anatomía & histología , Cavidad Pulpar/diagnóstico por imagen , Dentición Permanente , Humanos , Diente Molar/anatomía & histología , Raíz del Diente/anatomía & histología , Raíz del Diente/diagnóstico por imagen
5.
Int Endod J ; 52(11): 1635-1644, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31127955

RESUMEN

AIM: To compare two preparation systems and two sonic irrigation devices during the removal of root filling material from oval distal canals of extracted mandibular molars. METHODOLOGY: The distal canals in 40 extracted mandibular molars were shaped using the ProTaper Next system (Dentslpy Sirona, Ballaigues, Switzerland), filled with Gutta Percha X2 (Dentsply Sirona), along with AH Plus sealer (Dentsply De Trey, Konstanz, Germany) and randomly divided into two groups (n = 20) according to volume of initial filling, preparation diameter and working length. One group was retreated using the Reciproc system (VDW, Munich, Germany), and the other using the 2Shape system (Micro-Mega, Besançon, France). A micro-CT scan was taken after the initial root filling and after retreatment to evaluate the volume of filling material remnants. The teeth were divided into four groups to test the supplementary effect of two sonic irrigation devices on removing filling material: Eddy (VDW) and MM1500 (Micro-Mega). In the first and second groups, 2Shape was followed subsequently by MM1500 and Eddy; in the third and fourth groups, Reciproc was followed by MM1500 and Eddy. A third micro-CT was taken to compare the remaining root filling material in all groups. Wilcoxon's signed rank tests, Mann-Whitney and Kruskal-Wallis tests were used for statistical analysis. RESULTS: No significant difference was found for the volume of filling material removed between the Reciproc and 2Shape in the entire canal (P = 0.355). The volume dropped significantly from its initial value after removing the bulk of the root filling by 95.8% (from 4.71 to 0.22 mm3 ) with the 2Shape (P < 0.001) and by 94.0% (from 5.05 to 0.33 mm3 ) with the Reciproc (P < 0.001). Sonic activation significantly decreased the residual volume of filling material remnants by 3.21% (P = 0.013) in the first group, 1.38% (P = 0.012) in the second group, 1.83% (P = 0.008) in the third group and 1.83% (P = 0.012) in the fourth group. At the end, the percentage of residual material was not significantly different among the groups in the entire canal (P = 0.163). CONCLUSION: In the distal oval canals of extracted mandibular molar teeth, there was no significant difference between the 2Shape and Reciproc systems in removing gutta-percha/sealer. Sonic activation with MM1500 and Eddy significantly improved filling material removal.


Asunto(s)
Materiales de Obturación del Conducto Radicular , Obturación del Conducto Radicular , Cavidad Pulpar , Alemania , Gutapercha , Diente Molar , Retratamiento , Preparación del Conducto Radicular , Microtomografía por Rayos X
6.
Clin Nutr ; 38(1): 450-456, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-29249531

RESUMEN

BACKGROUND & AIMS: Cardiovascular disease (CVD) is highly prevalent in Suriname, a middle-income country with predominantly people of African and Asian ancestry. We examined whether the more comprehensive body composition measures determined by bioelectrical impedance analysis (BIA) are superior to the more traditional BMI and waist measures in relation to cardiovascular risk. METHODS: Data from the cross-sectional Healthy Life in Suriname (HELISUR) study were used to calculate BMI, waist-hip ratio, waist-to-height ratio, and waist circumference. BIA was used to estimate fat percentage, fat-free mass index, and fat-to-fat-free mass ratio. High cardiovascular risk was defined as 1) a 10-year Framingham coronary heart disease risk score ≥10% in African-Surinamese and ≥12% in Asian-Surinamese, and 2) an increased arterial stiffness (pulse wave velocity >10 m/s). Using logistic regression analysis, we pre-selected the strongest correlate (i.e. lowest p-value below 0.05) of all body composition items for both outcomes of cardiovascular risk separately, and subsequently, used forward logistic regression modelling to determine whether other measures added value to the initial model with the strongest correlate (-2 log-likelihood (-2LL) of initial model minus -2LL of new model, χ-square statistic >3.841, 1 df). Analyses were adjusted for sex, age and ethnicity. RESULTS: We examined 691 participants (65% women; 48% African-Surinamese) with a mean age of 42 (SD 14) years. Waist circumference was the strongest correlate for high 10-year CVD risk in the total group, in men and African-Surinamese. In Asian-Surinamese, fat-free mass index was the strongest correlate of high 10-year CVD risk. Increased arterial stiffness was most strongly related with waist-to-height ratio in the total group and in African-Surinamese, and with BMI in men. None of the measures were significantly associated in women (for both outcomes) and Asian-Surinamese (for increased arterial stiffness). Forward selection showed that only BMI added value next to waist-to-height ratio in the total group in relation to increased arterial stiffness. CONCLUSIONS: Waist measures, in particular waist circumference and waist-to-height ratio, and BMI should be used in African and Asian-Surinamese to identify who is at increased cardiovascular risk. Overall, we found little advantage in using BIA measures rather than simple anthropometric measures.


Asunto(s)
Pueblo Asiatico/etnología , Población Negra/etnología , Composición Corporal/fisiología , Enfermedades Cardiovasculares/diagnóstico , Enfermedades Cardiovasculares/epidemiología , Adulto , Índice de Masa Corporal , Estudios Transversales , Impedancia Eléctrica , Femenino , Humanos , Masculino , Prevalencia , Factores de Riesgo , Suriname/epidemiología , Circunferencia de la Cintura
7.
Eur Arch Paediatr Dent ; 17(5): 419-422, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27613404

RESUMEN

BACKGROUND: Arsenic oxide compounds were traditionally used as devitalizing agents. Due to its toxicity, leakage of such compounds into the periodontium can cause gingival and osteo-necrosis. Their use is forbidden in Europe and the USA for decades, however, some dentists seem to still use it. CASE REPORT: We report the case of a 14-year-old girl referred to the paediatric dentistry department of Toulouse University hospital, France, presenting a bone necrosis following the use of an arsenic trioxide product to accelerate pulp necrosis. TREATMENT: The treatment included surgical removal of necrosis bone sequestrum, complete pulpectomy and an intermediate restoration of the tooth 27. FOLLOW-UP: After 1 week, the clinical conditions greatly improved. A restoration using a ceramic crown was performed after 2 months, and complete healing was observed after 1 year follow-up. CONCLUSION: Although arsenic trioxide is neither appropriate nor permitted for use in modern dentistry, especially in paediatric dentistry, some rare cases of arsenic-induced osteo-necrosis can still be encountered. A clearer message must be given to all dental practitioners against the use of arsenic trioxide in modern endodontic treatment.


Asunto(s)
Arsenicales/efectos adversos , Necrosis de la Pulpa Dental/tratamiento farmacológico , Osteonecrosis/inducido químicamente , Óxidos/efectos adversos , Adolescente , Trióxido de Arsénico , Materiales Dentales/efectos adversos , Desvitalización de la Pulpa Dental/efectos adversos , Femenino , Francia , Enfermedades de las Encías/inducido químicamente , Humanos , Enfermedades Mandibulares/inducido químicamente , Necrosis/inducido químicamente , Osteonecrosis/diagnóstico por imagen , Osteonecrosis/patología , Osteonecrosis/cirugía , Pulpectomía
8.
Dentomaxillofac Radiol ; : 20140413, 2015 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-26035448

RESUMEN

OBJECTIVES: To determine the optimal cone beam computed tomography settings for an automatic edge-detection based endodontic segmentation procedure by assessing the accuracy of the root canal measurements. METHODS: Twelve intact teeth with closed apexes were cut perpendicular to the root axis, at predetermined levels to the reference plane (first section made before acquisition). Acquisitions of each specimen were performed with the "9000 3D®" (76µm, 14 bits) by using different combinations of milliamps and kilovolts. 3 dimensional images were displayed and root canals were segmented with the MeVisLab software (edge-detection based method). Histological root canal sections were then digitized with a 0,5 to 1µm resolution and compared with equivalent 2 dimensional cone-beam reconstructions for each pair of settings using Pearson correlation coefficient, regression analysis and Bland-Altman method for the canal area and Feret's diameter. After a ranking process, a Wilcoxon paired test was done to compare the pair of settings. RESULTS: The best pair of acquisition settings was: 3.2mA/60kV. Significant differences were found between 3.2mA/60kV and other settings (p <0.05) for root canal area and for Feret's diameter. CONCLUSIONS: The quantitative analyses of the root canal system with edge-detection based method could depend on acquisition parameters. Improvements in segmentation still need to be done to ensure the quality of the reconstructions when we have to deal with closer outlines and because of the low spatial resolution.

9.
Dentomaxillofac Radiol ; 44(8): 20140413, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26119343

RESUMEN

OBJECTIVES: To determine the optimal CBCT settings for an automatic edge-detection-based endodontic segmentation procedure by assessing the accuracy of the root canal measurements. METHODS: 12 intact teeth with closed apexes were cut perpendicular to the root axis, at pre-determined levels to the reference plane (the first section made before acquisition). Acquisitions of each specimen were performed with Kodak 9000(®) 3D (76 µm, 14 bits; Kodak Carestream Health, Trophy, France) by using different combinations of milliamperes and kilovolts. Three-dimensional images were displayed and root canals were segmented with the MeVisLab software (edge-detection-based method; MeVis Research, Bremen, Germany). Histological root canal sections were then digitized with a 0.5- to 1.0-µm resolution and compared with equivalent two-dimensional cone-beam reconstructions for each pair of settings using the Pearson correlation coefficient, regression analysis and Bland-Altman method for the canal area and Feret's diameter. After a ranking process, a Wilcoxon paired test was carried out to compare the pair of settings. RESULTS: The best pair of acquisition settings was 3.2 mA/60 kV. Significant differences were found between 3.2 mA/60 kV and other settings (p < 0.05) for the root canal area and for Feret's diameter. CONCLUSIONS: The quantitative analyses of the root canal system with the edge-detection-based method could depend on acquisition parameters. Improvements in segmentation still need to be carried out to ensure the quality of the reconstructions when we have to deal with closer outlines and because of the low spatial resolution.


Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Cavidad Pulpar/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Diente Premolar/diagnóstico por imagen , Diente Canino/diagnóstico por imagen , Humanos , Imagenología Tridimensional/métodos , Incisivo/diagnóstico por imagen , Diente Molar/diagnóstico por imagen , Odontometría/métodos , Radiografía Dental Digital/métodos , Reproducibilidad de los Resultados , Ápice del Diente/diagnóstico por imagen
10.
Odontostomatol Trop ; 34(133): 13-9, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21682215

RESUMEN

Canal entrances can be flared using specific, low speed, continuously rotating Ni-Ti instruments. Two such instruments were evaluated for their capacity to flare the canal entrance while respecting the initial canal axis. Lower molars (n = 20) with two distinct mesial canals were prepared to within 2.5 mm of the pulp chamber floor using Bramante's technique. Canal entrances were flared with a QUANTEC FLARE LX or an ENDOFLARE. They both had a 0.12 taper and a #25 tip diameter. The instruments were first inserted in the canals using an axial movement and then withdrawn with a selective circumferential brushing action. Photographs taken before and after each preparation were compared. No ledging or significant modification of the working length was noted. The centre of mass was displaced on average by 0.138 mm with no brushing action and 0.274 mm with brushing action. In most cases (87.5%), the centre of mass was displaced mesially. The two instruments behaved in an identical mode, both before (p = 0.3497) and after (p = 0.9304) the brushing action. Ni-Ti flaring instruments can be used to flare the canal entrance with little displacement of the initial canal axis, even when a brushing action is used.


Asunto(s)
Instrumentos Dentales , Cavidad Pulpar/anatomía & histología , Diseño de Equipo , Diente Molar/anatomía & histología , Preparación del Conducto Radicular/instrumentación , Cavidad Pulpar/cirugía , Dentición Permanente , Humanos , Mandíbula , Corona del Diente/anatomía & histología
11.
Odontostomatol Trop ; 33(129): 23-8, 2010 Mar.
Artículo en Francés | MEDLINE | ID: mdl-20839476

RESUMEN

UNLABELLED: The Nickel-titanium (Ni-Ti) instruments superelasticity does not does not allow to anticipate rupture. AIM: This study evaluates the effect of electropolishing time on the rupture resistance in flexion fatigue of the endodontics Ni-Ti instruments. METHODS: 48 HeroShapers 6% 25/100 are divided into 4 groups of surface treatment (without electropolishing, with electropolishing of 70, 80 or 90 seconds). The surface of the instruments is observed under a scanning electron microscope. Each instrument is driving by an inGet control motor at 275 rpm and put on a fatigue bench (stainless steel pipe angled at 60 degrees with r = 10 mm). The number of turn before rupture is recorded by a specific meter. Data were analysed by analysis of variance and a Fischer probable least-square difference test (PLSD) at a significance level of 0.05. RESULTS: The mean number of rotation to failure in each group of instrument decreases (407 to 355 tours) with the increase of the electropolishing time. There were no statistically significant difference (p = 0, 3508) between the different groups. CONCLUSION: Electropolishing from 70 till 90 seconds improves the surface state without modifying the rupture resistance in flexion fatigue of triple helix endodontic instruments with 6% taper.


Asunto(s)
Aleaciones Dentales , Instrumentos Dentales , Pulido Dental , Níquel , Preparación del Conducto Radicular/instrumentación , Titanio , Análisis de Varianza , Pulido Dental/métodos , Análisis del Estrés Dental , Falla de Equipo , Análisis de los Mínimos Cuadrados , Propiedades de Superficie , Factores de Tiempo , Torsión Mecánica
12.
Odontostomatol Trop ; 31(121): 5-11, 2008 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-18623974

RESUMEN

AIMS: This study set out to evaluate the prevalence of iatrogenic events during preclinical teaching of endodontics, comparing manual stainless steel versus nickel-titanium (Ni-Ti) rotary techniques for shaping natural root canals. METHOD: Two groups of 13 inexperienced dental students were randomly made up and asked to shape 104 canals in natural teeth. Group R used Ni-Ti rotary files for shaping while Group M used a sequence of five manual stainless steel files. Occurrence of file breakage, loss of work length, and iatrogenic instrumentation on apical foramina were evaluated. RESULTS: Overall occurrence of adverse events during shaping did not differ between the groups, being 58% in Group R and 51% in Group M. Inter-group distribution of type of event differed significantly, however. File breakage (7.7%) and loss of working length of > 2 mm (6.7%) occurred only in Group R. Iatrogenic shaping on apical foramina showed the same frequency in each group. CONCLUSION: Manual instrumentation is safer than rotary instrumentation in the hands of inexperienced students. Acquiring skill in the use of Ni-Ti rotary instrumentation requires specific preclinical training to avert file breakage. These findings argue for the rethinking of theoretical and practical coursework in endodontics teaching, especially in dentistry schools where students are required to treat patients during their training.


Asunto(s)
Instrumentos Dentales/efectos adversos , Endodoncia/educación , Preparación del Conducto Radicular/instrumentación , Competencia Clínica , Aleaciones Dentales , Falla de Equipo , Humanos , Enfermedad Iatrogénica , Níquel , Acero Inoxidable , Estudiantes de Odontología , Titanio
13.
Sante Publique ; 17(2): 255-64, 2005 Jun.
Artículo en Francés | MEDLINE | ID: mdl-16001567

RESUMEN

A retrospective study was carried out looking at the files of 481 patients who were seen for their first consultation at a university hospital dental school clinic. Their needs for conservative treatment were evaluated and the data from their files were analysed, including the following elements: demography, general health status, the expressed reason for the consultation, and the initially planned treatment. The descriptive analysis reveals a relatively young population group with an average age of 43.8 years, for whom 32% of them had existing or past medical conditions which necessitated that certain precautions be taken when prescribing conservative treatment. The most frequently given reasons for the consultation were the need for an annual dental check-up (41%) and pain (20%). 74% of the patients were in need of conservative treatments, and a priority for an initial treatment was cited for 48.4% of them.


Asunto(s)
Atención Odontológica , Hospitales Universitarios/estadística & datos numéricos , Salud Bucal , Derivación y Consulta , Adulto , Anciano , Femenino , Francia , Humanos , Masculino , Persona de Mediana Edad , Planificación de Atención al Paciente , Estudios Retrospectivos
14.
Am J Respir Crit Care Med ; 163(4): 994-1001, 2001 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-11282779

RESUMEN

The effects of a deep inspiration (DI) in individuals with asthma differ from those observed in healthy subjects. It has been postulated that the beneficial effect of lung inflation is mediated by airway stretch. One hypothesis to explain the defects in the function of lung inflation in asthma is that a DI may be unable to stretch the airways. This may result from attenuation of the tethering forces between the airways and the surrounding parenchyma. In the current study, we used high-resolution computed tomography (HRCT) to examine the ability of a DI to distend the airways of subjects with asthma (n = 10) compared with healthy subjects (n = 9) at baseline and after increasing airway tone with methacholine (MCh). We found that both at baseline and after the induction of smooth muscle tone with MCh, a DI distended the airways of healthy and asthmatic subjects to a similar extent, indicating that abnormal interdependence between the lung parenchyma and the airways is unlikely to play a major role in the loss or attenuation of the beneficial effect of lung inflation that characterizes asthma. Furthermore, we observed that after constriction had already been induced by MCh, following a DI, bronchodilation occurred in the healthy subjects but further bronchoconstriction occurred in the subjects with asthma. Our findings suggest that an abnormal excitation contraction mechanism in the airway smooth muscle of subjects with mild asthma counteracts the bronchodilatory effect of a DI. Therefore, the mechanism for reduced bronchodilation after DIs in subjects with mild asthma could be intrinsic to the airway smooth muscle.


Asunto(s)
Asma/diagnóstico por imagen , Asma/fisiopatología , Pulmón/diagnóstico por imagen , Mecánica Respiratoria/fisiología , Tomografía Computarizada por Rayos X/métodos , Adulto , Resistencia de las Vías Respiratorias , Pruebas de Provocación Bronquial , Femenino , Humanos , Mediciones del Volumen Pulmonar , Masculino , Cloruro de Metacolina , Probabilidad , Alveolos Pulmonares/diagnóstico por imagen , Alveolos Pulmonares/fisiopatología , Valores de Referencia , Pruebas de Función Respiratoria
15.
Clin Exp Allergy ; 30(9): 1257-65, 2000 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-10971472

RESUMEN

BACKGROUND: Several studies suggest that endogenous glucocorticoids can dampen the severity of experimental allergic reactions in animals. OBJECTIVE: To investigate the influence that endogenous glucocorticoids have on the course of IgE-mediated pulmonary early and late phase reactions. METHODS: Twenty-one allergic asthmatic and six healthy control subjects underwent inhaled antigen challenge with measurements of plasma cortisol and cortisone by gas chromatography-mass spectrometry. RESULTS: There were no differences between the asthmatic and control groups in the baseline levels of cortisol or cortisone. However, the asthmatic subjects had significantly higher cortisol levels (67.2 +/- 8.6 vs 35.1 +/- 4.5 ng/mL; P = 0.04) and had higher cortisol/cortisone ratios (4.8 +/- 0. 6 vs 3.0 +/- 0.2; P = 0.01) 8 h after challenge compared to the control subjects. Among the asthmatic subjects, those whose FEV1 recovered rapidly had higher baseline levels of cortisol and those who displayed a late phase reaction had lower levels of cortisol during the late phase period. CONCLUSION: The results suggest that endogenous glucocorticoids may play a significant role in the modulation of airway responses to antigen challenge, and that antigen challenge may induce cortisol production in allergic subjects.


Asunto(s)
Antígenos/inmunología , Asma/fisiopatología , Broncoconstricción , Cortisona/sangre , Hidrocortisona/sangre , Mecánica Respiratoria , Adulto , Asma/sangre , Asma/inmunología , Pruebas de Provocación Bronquial , Femenino , Volumen Espiratorio Forzado , Humanos , Masculino , Persona de Mediana Edad
16.
Am J Respir Crit Care Med ; 161(4 Pt 1): 1256-63, 2000 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-10764321

RESUMEN

Normal subjects prevented from taking a deep breath show changes in airflow similar to those of asthmatics when challenged with methacholine (MCh). To confirm airway narrowing by MCh in this setting and to determine its location, we concurrently measured changes in airway lumenal area using high resolution computed tomography (HRCT) and airflow using partial spirometry in five normal subjects challenged with increasing doses of MCh under prohibition of deep breaths. In an attempt to improve imaging accuracy, we corrected for the changes in lung volume during bronchoprovocation. At every step of the provocation, scanning was performed at approximately the same lung volume. On the HRCT images, airway area decreased in response to the increasing doses of MCh to 91 +/- 2%, 88 +/- 2%, and 80 +/- 2% of baseline at the doses of MCh 0.25, 0.75, and 2.5 mg/ml, respectively (p < 0.001). Airway narrowing showed no predilection for particular airway sizes and occurred in a heterogeneous pattern. The changes in the mean airway lumenal area as measured by HRCT and the mean partial spirometric outcomes were highly correlated: FEV(1)p (r(2) = 0.46, p = 0.001), FVCp (r(2) = 0.20, p = 0.05), FEV(1)/FVCp (r(2) = 0.55, p = 0.002), MMEFp (r(2) = 0.31, p = 0.01), and taup (r(2) = 0.51, p = 0.0004). We conclude that in normal subjects who are prevented from taking a deep breath, the spirometric changes occurring with aerosol MCh challenge are associated with conducting airway narrowing.


Asunto(s)
Pruebas de Provocación Bronquial , Broncoconstricción/efectos de los fármacos , Broncoconstrictores , Cloruro de Metacolina , Adulto , Algoritmos , Broncoconstricción/fisiología , Femenino , Humanos , Mediciones del Volumen Pulmonar , Masculino , Espirometría , Tomografía Computarizada por Rayos X
17.
Chest ; 114(4): 998-1007, 1998 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-9792568

RESUMEN

STUDY OBJECTIVE: To develop and evaluate a brief, easy-to-administer symptom assessment scale for use as a preference-based outcome measure in clinical trials and cost-effectiveness studies in asthma. DESIGN: Cross-sectional survey with 2-week reproducibility assessment. SETTING: Ambulatory care: university asthma and allergy center. PARTICIPANTS: One hundred sixty-one adults with asthma, 59% female, mean age 35+/-11 years. Mean FEV1 percent predicted was 86+/-17%. INTERVENTIONS: The 11-item Asthma Symptom Utility Index (ASUI). MEASUREMENTS AND RESULTS: Mean ASUI score for this sample was 0.71+/-0.23, with a range from 0.02 to 1.0. The ASUI was reproducible (intraclass correlation coefficient = 0.74) and able to distinguish patients known to differ on disease severity according to clinician ratings (p < 0.001) and by an asthma disease severity scale score (p < 0.001). The instrument was also significantly correlated with FEV1 percent predicted (r = 0.27, p < 0.001), the Asthma Quality of Life Questionnaire (r = 0.77, p < 0.001), and the Health Utilities Index Mark 2 (r = 0.36, p < 0.001). CONCLUSION: The results of this study support the reliability and validity of the ASUI, suggesting it will be a useful, complementary patient outcome measure for clinical trials and cost-effectiveness studies comparing treatment alternatives for persons with asthma.


Asunto(s)
Asma/psicología , Evaluación de Resultado en la Atención de Salud , Satisfacción del Paciente , Calidad de Vida/psicología , Adulto , Asma/economía , Asma/terapia , Estudios Transversales , Femenino , Estudios de Seguimiento , Humanos , Masculino , Educación del Paciente como Asunto , Pruebas de Personalidad , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Perfil de Impacto de Enfermedad , Encuestas y Cuestionarios
18.
Qual Life Res ; 7(8): 693-702, 1998 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-10097618

RESUMEN

The Rhinitis Symptom Utility Index (RSUI) was developed as a preference-based measure of rhinitis symptoms. The RSUI consist of ten questions on the severity and frequency of stuffy or blocked nose, runny nose, sneezing, itching, watery eyes and itching nose or throat over a 14 day period. A cross-sectional survey of 100 adults with allergic rhinitis was completed, with data collected on rhinitis history and severity, physician-rated rhinitis severity, the Rhinitis Quality of Life Questionnaire (RQLQ) and the Health Utilities Index Mark 2 (HUI2). The mean age of the patients was 37 +/- 11 years and 60% were female and 38% had a diagnosis of asthma. A multiplicative multiattribute utility function was developed from patient-derived preferences for different rhinitis-related symptom states. The mean RSUI score for this sample was 0.72 +/- 0.23, with a range of 0.15-1.0. Two week reproducibility of the RSUI was weak (ICC = 0.40). The index differentiated patients by physician-rated severity (p < 0.05) and was correlated 0.35 (p < 0.001) with the HUI2 and -0.67 (p < 0.001) with the RQLQ total score. The RSUI is brief and easy to administer and the results of this study support its reliability and validity. The modest reproducibility reflects the day to day variability of rhinitis. The RSUI may be a useful patient outcome for clinical trials and for cost-effectiveness studies comparing medical treatments for rhinitis.


Asunto(s)
Calidad de Vida , Rinitis Alérgica Perenne/psicología , Índice de Severidad de la Enfermedad , Adulto , Estudios Transversales , Interpretación Estadística de Datos , Estudios de Evaluación como Asunto , Femenino , Indicadores de Salud , Humanos , Masculino , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA