1.
Artículo en Inglés | MEDLINE | ID: mdl-39161058

RESUMEN

BACKGROUND: Robot-assisted implant surgery has emerged as a novel digital technology, and the accuracy need further assessment. PURPOSE: This study aimed to compare the accuracy of single dental implant placement between a novel semi-active robot-assisted implant surgery (RAIS) method and the conventional free-hand implant surgery (FHIS) method through a multicenter, randomized controlled clinical trial. MATERIALS AND METHODS: Patients requiring single dental implant placement were recruited and randomized into RAIS and FHIS group. Deviations at the platform, apex, and angle between the planned and final implant positions were assessed in both groups. Additionally, the evaluation of instrument and surgical complications was examined. RESULTS: A total of 140 patients (median age: 35.35 ± 12.55 years; 43 males, 97 females) with 140 implants from four different research centers were included, with 70 patients (70 implants) in the RAIS group and 70 patients (70 implants) in the FHIS group. In the RAIS and FHIS groups, the median platform deviations were 0.76 ± 0.36 mm and 1.48 ± 0.93 mm, respectively (p < 0.001); median apex deviations were 0.85 ± 0.48 mm and 2.14 ± 1.25 mm, respectively (p < 0.001); and median angular deviations were 2.05 ± 1.33° and 7.36 ± 4.67°, respectively (p < 0.001). Similar significant difference also presented between RAIS and FHIS group in platform vertical/horizontal deviation, apex vertical/horizontal deviation. Additionally, implants with self-tapping characteristics exhibited significantly larger deviations compared with those without self-tapping characteristics in the RAIS group. Both RAIS and FHIS methods demonstrated comparable morbidity and safety pre- and post-operation. CONCLUSIONS: The results indicated that the RAIS method demonstrated superior accuracy in single dental implant placement compared with the FHIS method. Specifically, RAIS exhibited significantly smaller deviations in platform, apex, and angular positions, as well as platform and apex vertical/horizontal deviations. This clinical trial was not registered prior to participant recruitment and randomization. https://www.chictr.org.cn/showproj.html?proj=195045.

2.
Int J Biol Macromol ; 271(Pt 1): 132119, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38816297

RESUMEN

Hyaluronic acid-based hydrogels have been broadly used in medical applications due to their remarkable properties such as biocompatibility, biodegradability, super hydroscopicity, non-immunogenic effect, etc. However, the inherent weak and hydrophilic polysaccharide structure of pure hyaluronic acid (HA) hydrogels has limited their potential use in muco-adhesiveness, wound dressing, and 3D printing. In this research, we developed in-situ forming of catechol-modified HA hydrogels with improved mechanical properties involving blue-light curing crosslinking reaction. The effect of catechol structure on the physicochemical properties of HA hydrogels was evaluated by varying the content (0-40 %). The as-synthesized hydrogel demonstrated rapid prototyping, excellent wetting adhesiveness, and good biocompatibility. Furthermore, an optimized hydrogel precursor solution was used as a blue light-cured bio-ink with high efficiency and good precision and successfully prototyped a microstructure that mimicked the human hepatic lobule by using DLP 3D printing method. This catechol-modified HA hydrogel with tunable physicochemical and rapid prototyping properties has excellent potential in biomedical engineering.


Asunto(s)
Catecoles , Ácido Hialurónico , Hidrogeles , Ácido Hialurónico/química , Hidrogeles/química , Catecoles/química , Humanos , Impresión Tridimensional , Materiales Biocompatibles/química , Adhesividad
3.
J Cell Biochem ; 125(2): e30504, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-37992225

RESUMEN

This study aimed to investigate the effect and mechanism of 2α, 3α, 24-thrihydroxyurs-12-en-24-ursolic acid (TEOA) alone or in combination with cisplatin on oral cancer. TEOA, a pentacyclic triterpenoid compound isolated from the roots of Actinidia eriantha, has demonstrated antitumor activity in preclinical experiments. However, its role in oral cancer remains poorly understood. Our findings revealed that a low concentration of TEOA did not exhibit significant cytotoxicity against oral squamous cell carcinoma cells. However, when combined with cisplatin, TEOA showed a significant therapeutic effect. The combined treatments resulted in a significant inhibition of proliferation and migration and a significant increase in apoptosis of squamous cell carcinoma cells. Cisplatin exposure increased autophagy levels, which may contribute to chemoresistance. Of note, the presence of TEOA significantly inhibited cisplatin-induced autophagy, leading to improved chemotherapy efficacy. Our findings indicate that a mild low dosage of TEOA may enhance the cytotoxic effect of cisplatin by downregulating autophagy in oral cancer cells.


Asunto(s)
Antineoplásicos , Carcinoma de Células Escamosas , Neoplasias de Cabeza y Cuello , Neoplasias de la Boca , Humanos , Cisplatino/farmacología , Cisplatino/uso terapéutico , Ácido Ursólico , Carcinoma de Células Escamosas/patología , Neoplasias de la Boca/tratamiento farmacológico , Neoplasias de la Boca/patología , Línea Celular Tumoral , Antineoplásicos/farmacología , Antineoplásicos/uso terapéutico , Autofagia , Apoptosis , Resistencia a Antineoplásicos , Proliferación Celular
4.
J Prosthet Dent ; 2023 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-37718179

RESUMEN

Implant abutment fractures are an uncommon mechanical complication, and the removal of the abutment fragment and replacement with a new prosthesis is the best solution. However, successful retrieval of the fractured abutment fragment from the implant is challenging, and effective rescue kits are lacking. This clinical report describes the retrieval of a fractured implant abutment in a conical connection implant using a modified manufacturer-specific instrument.

5.
Clin Implant Dent Relat Res ; 25(5): 815-828, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37248812

RESUMEN

BACKGROUND: The survival rate, marginal bone loss and soft tissue health of the Ankylos implants and the balanced base abutments in all-on-four or six implant restoration of edentulous or terminal dentition patients has not been reported in the clinical research. PURPOSE: This retrospective study aimed to evaluate the Ankylos implants and the balanced base abutments in all-on-four or six implant restoration of edentulous or terminal dentition patients after 1-8 years of follow-up. MATERIALS AND METHODS: A retrospective study was conducted based on the medical records of 33 patients who received all-on-four or six treatments from April 2014 to May 2020. Four radiographic examinations [immediate postoperative (T0), definitive restorations (T1), 1-3 years after prosthetic restorations (T2), and more than 3 years after prosthetic restorations (T3)] were obtained to evaluate vertical bone height (VBH). We also calculated the survival rate and examined the condition of soft tissue with this implant system in edentulous or terminal dentition patients. Three-level linear model analyses were used to explore potential risk factors for VBH changes on the mesial and distal sides. The generalized linear model was used to analyze the influencing factors of BOP and plaque. RESULTS: A total of 218 implants were included in this study. The cumulative survival rate of the implants was 97.25% before the definitive prosthesis, 96.33% within 3 years of follow-up and 95.32% after more than 3 years of follow-up. The mean ± standard deviation (SD) bone losses of the VBH were 0.27 ± 0.05 mm (T1-T3) on the mesial side and 0.49 ± 0.06 mm (T1-T3) on the distal side. During 1-8 years of follow-up, the height and angle of the abutment (p < 0.001), the mandible implant site (p < 0.001), the length of the implant (p = 0.014 < 0.05) and age (p = 0.029 < 0.05) showed statistically significant effects on vertical mesial bone height (VMBH) and vertical distal bone height (VDBH). The risk of BOP among participants who brushed three times a day was lower than those who brushed less than three times. The plaque risk of short abutment height was higher than the long abutment. CONCLUSION: The current study showed that the Ankylos implants with the balanced base abutments in all-on-four or six implants treatment is a viable and predictable option with a high survival rate and low marginal bone loss in edentulous or terminal dentition patients. VBH around the implants was strongly associated with the mandible implant site, abutment height and angle, the length of the implant and age. Moreover, teeth-brushing times and abutment height significantly affect soft tissue health.


Asunto(s)
Pérdida de Hueso Alveolar , Implantes Dentales , Boca Edéntula , Humanos , Estudios Retrospectivos , Estudios de Seguimiento , Dentición , Implantación Dental Endoósea , Prótesis Dental de Soporte Implantado , Pérdida de Hueso Alveolar/diagnóstico por imagen , Pérdida de Hueso Alveolar/etiología
6.
BMC Oral Health ; 23(1): 179, 2023 03 28.
Artículo en Inglés | MEDLINE | ID: mdl-36978064

RESUMEN

BACKGROUND: To compare the accuracy of dental implant placement using a novel dental implant robotic system (THETA) and a dynamic navigation system (Yizhimei) by a vitro model experiment. METHODS: 10 partially edentulous jaws models were included in this study, and 20 sites were randomly assigned into two groups: the dental implant robotic system (THETA) group and a dynamic navigation system (Yizhimei) group. 20 implants were placed in the defects according to each manufacturer's protocol respectively. The implant platform, apex and angle deviations were measured by fusion of the preoperative design and the actual postoperative cone-beam computed tomography (CBCT) using 3D Slicer software. Data were analyzed by t - test and Mann-Whitney U test, p < 0.05 was considered statistically significant. RESULTS: A total of 20 implants were placed in 10 phantoms. The comparison deviation of implant platform, apex and angulation in THETA group were 0.58 ± 0.31 mm, 0.69 ± 0.28 mm, and 1.08 ± 0.66° respectively, while in Yizhimei group, the comparison deviation of implant platform, apex and angulation were 0.73 ± 0.20 mm, 0.86 ± 0.33 mm, and 2.32 ± 0.71° respectively. The angulation deviation in THETA group was significantly smaller than the Yizhimei group, and there was no significant difference in the deviation of the platform and apex of the implants placed using THETA and Yizhimei, respectively. CONCLUSION: The implant positioning accuracy of the robotic system, especially the angular deviation was superior to that of the dynamic navigation system, suggesting that the THETA robotic system could be a promising tool in dental implant surgery in the future. Further clinical studies are needed to evaluate the current results.


Asunto(s)
Implantación Dental Endoósea , Procedimientos Quirúrgicos Robotizados , Cirugía Asistida por Computador , Humanos , Diseño Asistido por Computadora , Tomografía Computarizada de Haz Cónico , Implantación Dental Endoósea/métodos , Implantes Dentales , Imagenología Tridimensional , Proyectos Piloto , Cirugía Asistida por Computador/métodos , Modelos Anatómicos , Fantasmas de Imagen
7.
BMC Oral Health ; 22(1): 431, 2022 09 30.
Artículo en Inglés | MEDLINE | ID: mdl-36180871

RESUMEN

BACKGROUND: The combination of a prosthetic index with Morse taper connection was developed, with the purpose of making prosthetic procedures more precise. However, the presence of the index may compromise the mechanical performance of the abutment. The aim of this study is to evaluate the effect of prosthetic index on stress distribution in implant-abutment-screw system and peri-implant bone by using the 3D finite element methodology. METHODS: Two commercial dental implant systems with different implant-abutment connections were used: the Morse taper connection with platform switching (MT-PS) implant system and the internal hex connection with platform matching (IH-PM) implant system. Meanwhile, there are two different designs of Morse taper connection abutment, namely, abutments with or without index. Consequently, three different models were developed and evaluated: (1) MT-PS indexed, (2) MT-PS non-indexed, and (3) IH-PM. These models were inserted into a bone block. Vertical and oblique forces of 100 N were applied to each abutment to simulate occlusal loadings. RESULTS: For the MT-PS implant system, the maximum stress was always concentrated in the abutment neck under both vertical and oblique loading. Moreover, the maximum von Mises stress in the neck of the MT-PS abutment with index even exceed the yield strength of titanium alloy under the oblique loading. For the IH-PM implant system, however, the maximum stress was always located at the implant. Additionally, the MT-PS implant system has a significantly higher stress level in the abutment neck and a lower stress level around the peri-implant bone compared to the IH-PM implant system. The combined average maximum stress from vertical and oblique loads is 2.04 times higher in the MT-PS indexed model, and 1.82 times for the MT-PS non-indexed model than that of the IH-PM model. CONCLUSIONS: MT-PS with index will cause higher stress concentration on the abutment neck than that of without index, which is more prone to mechanical complications. Nevertheless, MT-PS decreases stress within cancellous bone and may contribute to limiting crestal bone resorption.


Asunto(s)
Implantes Dentales , Aleaciones , Fenómenos Biomecánicos , Análisis del Estrés Dental/métodos , Análisis de Elementos Finitos , Humanos , Estrés Mecánico , Titanio
8.
Clin Implant Dent Relat Res ; 24(5): 683-695, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35791805

RESUMEN

BACKGROUND: The fracture of a Morse tapered abutment connection in an osseointegrated implant is one of the most serious mechanical complications, and it is extremely hard to deal with this complication in clinical practice. PURPOSE: The aim of this study was to explore the cumulative mechanical complications focus on abutment of a platform switching Morse taper connection implant system after loading, and to perform a retrospective, approximately 1- to 9-year follow-up study to identify the predisposing factors. MATERIALS AND METHODS: A total of 495 patients with 945 fitted implants were enrolled in this study with a follow-up from January 2012 to January 2020. The data of mechanical complications of the abutment, including abutment fracture (AF) and abutment screw loosening (ASL), and possible causative factors were extracted and evaluated statistically. RESULTS: A total of 25 out of 945 (2.65%) cumulative abutment mechanical complications occurred. AF was the most common complication (n = 13, 1.38%), followed by ASL (n = 12, 1.27%). For AF, gender, type of prosthesis, abutment design, and implant diameter were identified as the causative factors. AF was mostly observed in the single crown of males in molar areas, while ASL was more likely to occur on an angled abutment than on a non-angled abutment. Moreover, the abutment with the positioning index (/X) had a higher incidence of fracture than the abutment without the positioning index (C/). CONCLUSIONS: This study shows that the Morse taper connection is a safe abutment connection. AF occurs more frequently within single crowns in molar area of males, especially with the positioning index (/X), while ASL is more likely to occur in an angled abutment.


Asunto(s)
Implantes Dentales , Coronas , Pilares Dentales , Diseño de Implante Dental-Pilar/efectos adversos , Estudios de Seguimiento , Humanos , Masculino , Estudios Retrospectivos
9.
Sci Rep ; 11(1): 4947, 2021 03 02.
Artículo en Inglés | MEDLINE | ID: mdl-33654142

RESUMEN

This study evaluated the use of bone ring technique with xenogeneic bone grafts in treating horizontal alveolar bone defects. In total, 11 patients in need of horizontal bone augmentation treatment before implant placement were included in this retrospective study. All patients received simultaneous bone augmentation surgery and implant placement with xenogeneic bone ring grafts. We evaluated the postoperative efficacy of the bone ring technique with xenogeneic bone grafts using radiographical and clinical parameters. Survival rates of implants were 100%. Cone-beam computed tomography revealed that the xenogeneic bone ring graft had significantly sufficient horizontal bone augmentation below the implant neck platform to 0 mm, 1 mm, 2 mm, and 3 mm. It could also provide an excellent peri-implant tissue condition during the 1-year follow-up after loading. The bone ring technique with xenogeneic bone ring graft could increase and maintain horizontal bone mass in the region of the implant neck platforms in serious horizontal bone defects.


Asunto(s)
Pérdida de Hueso Alveolar , Proceso Alveolar , Trasplante Óseo , Tomografía Computarizada de Haz Cónico , Implantes Dentales , Adulto , Pérdida de Hueso Alveolar/diagnóstico por imagen , Pérdida de Hueso Alveolar/cirugía , Proceso Alveolar/diagnóstico por imagen , Proceso Alveolar/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad
10.
Oncol Lett ; 20(4): 39, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32788934

RESUMEN

An odontogenic keratocyst (OKC) is a common oral cyst arising from the odontogenic epithelium, which has the characteristics of a tumor. Previous studies have demonstrated that M2-polarized macrophages and angiogenesis have important roles in the progression of OKCs. As transforming growth factor (TGF)-ß1 is important in growth and developmental processes, and early studies have indicated that TGF-ß1 is upregulated in OKCs, the present study aimed to investigate the expression levels of TGF-ß1 as a first step. Flow cytometric analysis suggested that TGF-ß1 induced M2-polarization of macrophages in a dose-dependent manner. Expression levels of cyclooxygenase (COX)-1 and -2 were measured after treatment of M2 macrophages with TGF-ß1 and OKC homogenate supernatant. COX-2 expression was influenced by TGF-ß1 in a concentration-dependent manner and in OKC induction. In addition, inhibition of COX-2 resulted in the induction of M2-polarization of macrophages via TGF-ß1 and OKC disruption. Because the extracellular matrix (ECM) is altered in individuals with chronic diseases, the present study analyzed the expression of matrix metalloproteinase (MMP)-9, which is able to degrade the ECM. The present study observed a decrease in MMP-9 activity following treatment with TGF-ß1 and OKC homogenate supernatant. Additionally, the present study analyzed tube formation caused by OKC with or without a COX-2 inhibitor. The results of the present study suggested that angiogenesis increased following treatment with OKC homogenate supernatant but decreased after treatment with a COX-2 inhibitor. These findings indicated that the TGF-ß1/COX-2 pathway may have an important role in the progression of OKC.

11.
Zhonghua Zheng Xing Wai Ke Za Zhi ; 32(3): 161-5, 2016 May.
Artículo en Chino | MEDLINE | ID: mdl-30043598

RESUMEN

Objective: To investigate the effect of sagittal split ramus osteotomy(SSRO) combined with distraction osteogenesis(DO) for hemifacial microsomia (HFM). Methods: From January 2013 to September 2015,7 cases of unilateral HFM were included in the study. The 3-dimensional reconstruction images were used for the operation design. The location of the germs and inferior alveolar nerve was marked to avoid injury. The distractor was fixed after SSRO. The distractor was distracted 2-4 mm intraoperatively and began enlongation 3-5 days after operation,1-2 mm every day until the pre-designed length attained. The patients were followed up for 3-D CT and measurement of the height of bilateral ramus. Results: The enlongation length was 7 mm to 20 mm(mean,14.6 mm).The facial symmetry and occlusion plane was improved a lot. No complication occurred. The mean follow-up period was 22 months (range 17-32 months) with almost symmetrical appearance and occlusion function. Conclusions: SSRO combined with DO has a good therapeutic effect and low complication for patients with HFM. The distraction rate is relatively high with a short treatment period. The ramus width, even thickness, are not decreased, or even can be increased after DO.


Asunto(s)
Síndrome de Goldenhar/cirugía , Osteogénesis por Distracción/métodos , Osteotomía Sagital de Rama Mandibular/métodos , Asimetría Facial/cirugía , Humanos , Imagenología Tridimensional , Mandíbula/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA