Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Med Devices (Auckl) ; 17: 73-87, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38404631

RESUMEN

Subarachnoid haemorrhage (SAH) can trigger a range of poorly understood cerebrovascular responses that may play a role in delayed cerebral ischemia. The brain pulse monitor is a novel non-invasive device that detects a brain photoplethysmography signal that provides information on intracranial pressure (ICP), compliance, blood flow and tissue oxygen saturation. We monitored the cerebrovascular responses in a patient with Lundberg B waves following a SAH. The patient presented with a Fischer grade 4 SAH that required urgent left posterior communicating artery aneurysm coiling and ventricular drain insertion. On hospital day 4 oscillations or spikes on the invasive ICP were noted, consistent with Lundberg B waves. Brain pulse monitoring demonstrated concurrent pulse waveform features consistent with reduced brain compliance and raised ICP over both brain hemispheres. Oxygen levels also demonstrated slow oscillations correlated with the ICP spikes. Brief infrequent episodes of reduced and absent brain pulses were also noted over the right hemisphere. Our findings suggest that the brain pulse monitor holds promise for early detection of delayed cerebral ischemia and could offer insights into the vascular mechanisms at play.

2.
Eur Heart J Case Rep ; 7(9): ytad460, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38073677

RESUMEN

Background: Air emboli are a life-threatening diagnosis, which may form through a range of mechanisms. In this case, we describe the case of extensive multi-territory air emboli in a patient with a history of intravenous drug abuse. Case summary: This case describes a 41-year-old male who presented with confusion following fall with long lie. He was diagnosed with hyperkalaemia, renal failure, rhabdomyolysis, and compartment syndrome, and he developed extensive multi-territory air emboli. Air embolism was identified in arterial, venous, subcutaneous, and mediastinal territories. Echocardiography demonstrated right ventricular dilation and dysfunction, consistent with air visualized in the right coronary artery on computed tomography. The patient was transferred to the intensive care unit for close cardiac and neurological monitoring and supportive organ care, and ultimately made an uneventful recovery by 6 weeks without apparent complications from the air emboli. Discussion: The presence of multi-territory air emboli has previously been described in the setting of surgery, manipulation of intravascular catheters, pulmonary barotrauma, and in sepsis with gas-forming organisms. It has not previously been reported in intravenous drug use or sterile rhabdomyolysis. Computed tomography imaging and echocardiography are useful to diagnose air emboli and their haemodynamic impact. Our patient's case provides a novel example of multi-territory air emboli in a unique scenario.

3.
Med Devices (Auckl) ; 16: 15-26, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36718229

RESUMEN

Background: Intracranial pressure (ICP) monitoring requires placing a hole in the skull through which an invasive pressure monitor is inserted into the brain. This approach has risks for the patient and is expensive. We have developed a non-invasive brain pulse monitor that uses red light to detect a photoplethysmographic (PPG) signal arising from the blood vessels on the brain's cortical surface. The brain PPG and the invasive ICP waveform share morphological features which may allow measurement of the intracranial pressure. Methods: We enrolled critically ill patients with an acute brain injury with invasive ICP monitoring to assess the new monitor. A total of 24 simultaneous invasive ICP and brain pulse monitor PPG measurements were undertaken in 12 patients over a range of ICP levels. Results: The waveform morphologies were similar for the invasive ICP and brain pulse monitor PPG approach. Both methods demonstrated a progressive increase in the amplitude of P2 relative to P1 with increasing ICP levels. An automated algorithm was developed to assess the PPG morphological features in relation to the ICP level. A correlation was demonstrated between the brain pulse waveform morphology and ICP levels, R2=0.66, P < 0.001. Conclusion: The brain pulse monitor's PPG waveform demonstrated morphological features were similar to the invasive ICP waveform over a range of ICP levels, these features may provide a method to measure ICP levels. Trial Registration: ACTRN12620000828921.

4.
Br J Clin Pharmacol ; 88(7): 3272-3287, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35106809

RESUMEN

There is significant interest in the potential for nebulised unfractionated heparin (UFH), as a novel therapy for patients with COVID-19 induced acute hypoxaemic respiratory failure requiring invasive ventilation. The scientific and biological rationale for nebulised heparin stems from the evidence for extensive activation of coagulation resulting in pulmonary microvascular thrombosis in COVID-19 pneumonia. Nebulised delivery of heparin to the lung may limit alveolar fibrin deposition and thereby limit progression of lung injury. Importantly, laboratory studies show that heparin can directly inactivate the SARS-CoV-2 virus, thereby prevent its entry into and infection of mammalian cells. UFH has additional anti-inflammatory and mucolytic properties that may be useful in this context. METHODS AND INTERVENTION: The Can nebulised HepArin Reduce morTality and time to Extubation in Patients with COVID-19 Requiring invasive ventilation Meta-Trial (CHARTER-MT) is a collaborative prospective individual patient data analysis of on-going randomised controlled clinical trials across several countries in five continents, examining the effects of inhaled heparin in patients with COVID-19 requiring invasive ventilation on various endpoints. Each constituent study will randomise patients with COVID-19 induced respiratory failure requiring invasive ventilation. Patients are randomised to receive nebulised heparin or standard care (open label studies) or placebo (blinded placebo-controlled studies) while under invasive ventilation. Each participating study collect a pre-defined minimum dataset. The primary outcome for the meta-trial is the number of ventilator-free days up to day 28 day, defined as days alive and free from invasive ventilation.


Asunto(s)
Tratamiento Farmacológico de COVID-19 , Ventilación no Invasiva , Insuficiencia Respiratoria , Extubación Traqueal , Heparina , Humanos , Pulmón , Ensayos Clínicos Controlados Aleatorios como Asunto , Insuficiencia Respiratoria/inducido químicamente , SARS-CoV-2 , Resultado del Tratamiento
5.
Br J Clin Pharmacol ; 88(6): 2802-2813, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-34984714

RESUMEN

AIMS: To determine the safety and efficacy-potential of inhaled nebulised unfractionated heparin (UFH) in the treatment of hospitalised patients with COVID-19. METHODS: Retrospective, uncontrolled multicentre single-arm case series of hospitalised patients with laboratory-confirmed COVID-19, treated with inhaled nebulised UFH (5000 IU q8h, 10 000 IU q4h, or 25 000 IU q6h) for 6 ± 3 (mean ± standard deviation) days. Outcomes were activated partial thromboplastin time (APTT) before treatment (baseline) and highest-level during treatment (peak), and adverse events including bleeding. Exploratory efficacy outcomes were oxygenation, assessed by ratio of oxygen saturation to fraction of inspired oxygen (FiO2 ) and FiO2 , and the World Health Organisation modified ordinal clinical scale. RESULTS: There were 98 patients included. In patients on stable prophylactic or therapeutic systemic anticoagulant therapy but not receiving therapeutic UFH infusion, APTT levels increased from baseline of 34 ± 10 seconds to a peak of 38 ± 11 seconds (P < .0001). In 3 patients on therapeutic UFH infusion, APTT levels did not significantly increase from baseline of 72 ± 20 to a peak of 84 ± 28 seconds (P = .17). Two patients had serious adverse events: bleeding gastric ulcer requiring transfusion and thigh haematoma; both were on therapeutic anticoagulation. Minor bleeding occurred in 16 patients, 13 of whom were on therapeutic anticoagulation. The oxygen saturation/FiO2 ratio and the FiO2 worsened before and improved after commencement of inhaled UFH (change in slope, P < .001). CONCLUSION: Inhaled nebulised UFH in hospitalised patients with COVID-19 was safe. Although statistically significant, inhaled nebulised UFH did not produce a clinically relevant increase in APTT (peak values in the normal range). Urgent randomised evaluation of nebulised UFH in patients with COVID-19 is warranted and several studies are currently underway.


Asunto(s)
Tratamiento Farmacológico de COVID-19 , Heparina , Anticoagulantes , Hemorragia/inducido químicamente , Hemorragia/tratamiento farmacológico , Heparina/efectos adversos , Humanos , Tiempo de Tromboplastina Parcial , Estudios Retrospectivos
6.
Lancet Respir Med ; 9(4): 360-372, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33493448

RESUMEN

BACKGROUND: Mechanical ventilation in intensive care for 48 h or longer is associated with the acute respiratory distress syndrome (ARDS), which might be present at the time ventilatory support is instituted or develop afterwards, predominantly during the first 5 days. Survivors of prolonged mechanical ventilation and ARDS are at risk of considerably impaired physical function that can persist for years. An early pathogenic mechanism of lung injury in mechanically ventilated, critically ill patients is inflammation-induced pulmonary fibrin deposition, leading to thrombosis of the microvasculature and hyaline membrane formation in the air sacs. The main aim of this study was to determine if nebulised heparin, which targets fibrin deposition, would limit lung injury and thereby accelerate recovery of physical function in patients with or at risk of ARDS. METHODS: The Can Heparin Administration Reduce Lung Injury (CHARLI) study was an investigator-initiated, multicentre, double-blind, randomised phase 3 trial across nine hospitals in Australia. Adult intensive care patients on invasive ventilation, with impaired oxygenation defined by a PaO2/FiO2 ratio of less than 300, and with the expectation of invasive ventilation beyond the next calendar day were recruited. Key exclusion criteria were heparin allergy, pulmonary bleeding, and platelet count less than 50 X 109/L. Patients were randomly assigned 1:1, with stratification by site and using blocks of variable size and random seed, via a web-based system, to either unfractionated heparin sodium 25 000 IU in 5 mL or identical placebo (sodium chloride 0·9% 5 mL), administered using a vibrating mesh membrane nebuliser every 6 h to day 10 while invasively ventilated. Patients, clinicians, and investigators were masked to treatment allocation. The primary outcome was the Short Form 36 Health Survey Physical Function Score (out of 100) of survivors at day 60. Prespecified secondary outcomes, which are exploratory, included development of ARDS to day 5 among at-risk patients, deterioration of the Murray Lung Injury Score (MLIS) to day 5, mortality at day 60, residence of survivors at day 60, and serious adverse events. Analyses followed the intention-to-treat principle. There was no imputation of missing data. The trial is registered with the Australian and New Zealand Clinical Trials Register, number ACTRN12612000418875 . FINDINGS: Between Sept 4, 2012, and Aug 23, 2018, 256 patients were randomised. Final follow-up was on Feb 25, 2019. We excluded three patients who revoked consent and one ineligible participant who received no intervention. Of 252 patients included in data analysis, the mean age was 58 years (SD 15), 157 (62%) were men, and 118 (47%) had ARDS. 128 (51%) patients were assigned to the heparin group and 124 (49%) to the placebo group, all of whom received their assigned intervention. Survivors in the heparin group (n=97) had similar SF-36 Physical Function Scores at day 60 compared to the placebo group (n=94; mean 53·6 [SD 31·6] vs 48·7 [35·7]; difference 4·9 [95% CI -4·8 to 14·5]; p=0·32). Compared with the placebo group, the heparin group had fewer cases of ARDS develop to day 5 among the at-risk patients (nine [15%] of 62 patients vs 21 [30%] of 71 patients; hazard ratio 0·46 [95% CI 0·22 to 0·98]; p=0·0431), less deterioration of the MLIS to day 5 (difference -0·14 [-0·26 to -0·02]; p=0·0215), similar day 60 mortality (23 [18%] of 127 patients vs 18 [15%] of 123 patients; odds ratio [OR] 1·29 [95% CI 0·66 to 2·53]; p=0·46), and more day 60 survivors at home (86 [87%] of 99 patients vs 73 [73%] of 100 patients; OR 2·45 [1·18 to 5·08]; p=0·0165). A similar number of serious adverse events occurred in each group (seven [5%] of 128 patients in the heparin group vs three [2%] of 124 patients in the placebo group; OR 2·33 [0·59 to 9·24]; p=0·23), which were a transient increase in airway pressure during nebulisation (n=3 in the heparin group), major non-pulmonary bleeding (n=2 in each group), haemoptysis (n=1 in the heparin group), tracheotomy site bleeding (n=1 in the heparin group), and hypoxaemia during nebulisation (n=1 in the placebo group). INTERPRETATION: In patients with or at risk of ARDS, nebulised heparin did not improve self-reported performance of daily physical activities, but was well tolerated and exploratory outcomes suggest less progression of lung injury and earlier return home. Further research is justified to establish if nebulised heparin accelerates recovery in those who have or are at risk of ARDS. FUNDING: Rowe Family Foundation, TR and RB Ditchfield Medical Research Endowment Fund, Patricia Madigan Charitable Trust, and The J and R McGauran Trust Fund.


Asunto(s)
Cuidados Críticos/métodos , Heparina/administración & dosificación , Respiración Artificial/efectos adversos , Síndrome de Dificultad Respiratoria/epidemiología , Actividades Cotidianas , Administración por Inhalación , Adulto , Anciano , Australia/epidemiología , Método Doble Ciego , Femenino , Hemoptisis/inducido químicamente , Hemoptisis/epidemiología , Heparina/efectos adversos , Mortalidad Hospitalaria , Humanos , Hipoxia/inducido químicamente , Hipoxia/epidemiología , Incidencia , Masculino , Persona de Mediana Edad , Nebulizadores y Vaporizadores , Placebos/administración & dosificación , Placebos/efectos adversos , Síndrome de Dificultad Respiratoria/diagnóstico , Síndrome de Dificultad Respiratoria/etiología , Síndrome de Dificultad Respiratoria/prevención & control , Autoinforme/estadística & datos numéricos , Índice de Severidad de la Enfermedad , Sobrevivientes/estadística & datos numéricos , Factores de Tiempo , Resultado del Tratamiento
7.
Br J Clin Pharmacol ; 87(8): 3075-3091, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33377218

RESUMEN

AIMS: Inhaled nebulised unfractionated heparin (UFH) has a strong scientific and biological rationale that warrants urgent investigation of its therapeutic potential in patients with COVID-19. UFH has antiviral effects and prevents the SARS-CoV-2 virus' entry into mammalian cells. In addition, UFH has significant anti-inflammatory and anticoagulant properties, which limit progression of lung injury and vascular pulmonary thrombosis. METHODS: The INHALEd nebulised unfractionated HEParin for the treatment of hospitalised patients with COVID-19 (INHALE-HEP) metatrial is a prospective individual patient data analysis of on-going randomised controlled trials and early phase studies. Individual studies are being conducted in multiple countries. Participating studies randomise adult patients admitted to the hospital with confirmed SARS-CoV-2 infection, who do not require immediate mechanical ventilation, to inhaled nebulised UFH or standard care. All studies collect a minimum core dataset. The primary outcome for the metatrial is intubation (or death, for patients who died before intubation) at day 28. The secondary outcomes are oxygenation, clinical worsening and mortality, assessed in time-to-event analyses. Individual studies may have additional outcomes. ANALYSIS: We use a Bayesian approach to monitoring, followed by analysing individual patient data, outcomes and adverse events. All analyses will follow the intention-to-treat principle, considering all participants in the treatment group to which they were assigned, except for cases lost to follow-up or withdrawn. TRIAL REGISTRATION, ETHICS AND DISSEMINATION: The metatrial is registered at ClinicalTrials.gov ID NCT04635241. Each contributing study is individually registered and has received approval of the relevant ethics committee or institutional review board. Results of this study will be shared with the World Health Organisation, published in scientific journals and presented at scientific meetings.


Asunto(s)
COVID-19 , Heparina , Adulto , Teorema de Bayes , Humanos , Estudios Prospectivos , SARS-CoV-2 , Resultado del Tratamiento
8.
Crit Care ; 24(1): 454, 2020 07 22.
Artículo en Inglés | MEDLINE | ID: mdl-32698853

RESUMEN

Nebulised unfractionated heparin (UFH) has a strong scientific and biological rationale and warrants urgent investigation of its therapeutic potential, for COVID-19-induced acute respiratory distress syndrome (ARDS). COVID-19 ARDS displays the typical features of diffuse alveolar damage with extensive pulmonary coagulation activation resulting in fibrin deposition in the microvasculature and formation of hyaline membranes in the air sacs. Patients infected with SARS-CoV-2 who manifest severe disease have high levels of inflammatory cytokines in plasma and bronchoalveolar lavage fluid and significant coagulopathy. There is a strong association between the extent of the coagulopathy and poor clinical outcomes.The anti-coagulant actions of nebulised UFH limit fibrin deposition and microvascular thrombosis. Trials in patients with acute lung injury and related conditions found inhaled UFH reduced pulmonary dead space, coagulation activation, microvascular thrombosis and clinical deterioration, resulting in increased time free of ventilatory support. In addition, UFH has anti-inflammatory, mucolytic and anti-viral properties and, specifically, has been shown to inactivate the SARS-CoV-2 virus and prevent its entry into mammalian cells, thereby inhibiting pulmonary infection by SARS-CoV-2. Furthermore, clinical studies have shown that inhaled UFH safely improves outcomes in other inflammatory respiratory diseases and also acts as an effective mucolytic in sputum-producing respiratory patients. UFH is widely available and inexpensive, which may make this treatment also accessible for low- and middle-income countries.These potentially important therapeutic properties of nebulised UFH underline the need for expedited large-scale clinical trials to test its potential to reduce mortality in COVID-19 patients.


Asunto(s)
Infecciones por Coronavirus/tratamiento farmacológico , Heparina/administración & dosificación , Nebulizadores y Vaporizadores , Neumonía Viral/tratamiento farmacológico , COVID-19 , Humanos , Pandemias , Ensayos Clínicos Controlados Aleatorios como Asunto , Resultado del Tratamiento
9.
Med Devices (Auckl) ; 13: 183-194, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32669881

RESUMEN

INTRODUCTION: Research in traumatic brain injury suggests better patient outcomes when invasive oxygen monitoring is used to detect and correct episodes of brain hypoxia. Invasive brain oxygen monitoring is, however, not routinely used due to the risks, costs and technical challengers. We are developing a non-invasive brain oximeter to address these limitations. The monitor uses the principles of pulse oximetry to record a brain photoplethysmographic waveform and oxygen saturations. We undertook a study in volunteers to assess the new monitor. PATIENTS AND METHODS: We compared the temporal changes in the brain and skin oxygen saturations in six volunteers undergoing progressive hypoxia to reach arterial saturations of 70%. This approach provides a method to discriminate potential contamination of the brain signal by skin oxygen levels, as the responses in brain and skin oxygen saturations are distinct due to the auto-regulation of cerebral blood flow to compensate for hypoxia. Conventional pulse oximetry was used to assess skin oxygen levels. Blood was also collected from the internal jugular vein and correlated with the brain oximeter oxygen levels. RESULTS: At baseline, a photoplethysmographic waveform consistent with that expected from the brain was obtained in five subjects. The signal was adequate to assess oxygen saturations in three subjects. During hypoxia, the brain's oximeter oxygen saturation fell to 74%, while skin saturation fell to 50% (P<0.0001). The brain photoplethysmographic waveform developed a high-frequency oscillation of ~7 Hz, which was not present in the skin during hypoxia. A weak correlation between the brain oximeter and proximal internal jugular vein oxygen levels was demonstrated, R2=0.24, P=0.01. CONCLUSION: Brain oximeter oxygen saturations were relatively well preserved compared to the skin during hypoxia. These findings are consistent with the expected physiological responses and suggest skin oxygen levels did not markedly contaminate the brain oximeter signal.

10.
J Clin Med ; 9(4)2020 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-32218127

RESUMEN

BACKGROUND: Pulmonary hypercoagulopathy is intrinsic to inhalation trauma. Nebulized heparin could theoretically be beneficial in patients with inhalation injury, but current data are conflicting. We aimed to investigate the safety, feasibility, and effectiveness of nebulized heparin. METHODS: International multicenter, double-blind, placebo-controlled randomized clinical trial in specialized burn care centers. Adult patients with inhalation trauma received nebulizations of unfractionated heparin (25,000 international unit (IU), 5 mL) or placebo (0.9% NaCl, 5 mL) every four hours for 14 days or until extubation. The primary outcome was the number of ventilator-free days at day 28 post-admission. Here, we report on the secondary outcomes related to safety and feasibility. RESULTS: The study was prematurely stopped after inclusion of 13 patients (heparin N = 7, placebo N = 6) due to low recruitment and high costs associated with the trial medication. Therefore, no analyses on effectiveness were performed. In the heparin group, serious respiratory problems occurred due to saturation of the expiratory filter following nebulizations. In total, 129 out of 427 scheduled nebulizations were withheld in the heparin group (in 3 patients) and 45 out of 299 scheduled nebulizations were withheld in the placebo group (in 2 patients). Blood-stained sputum or expected increased bleeding risks were the most frequent reasons to withhold nebulizations. CONCLUSION: In this prematurely stopped trial, we encountered important safety and feasibility issues related to frequent heparin nebulizations in burn patients with inhalation trauma. This should be taken into account when heparin nebulizations are considered in these patients.

11.
Med Devices (Auckl) ; 12: 479-487, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31824197

RESUMEN

INTRODUCTION: Evidence suggests treatments guided by brain oxygen levels improve patient outcomes following severe traumatic brain injury; however, brain oxygen levels are not routinely monitored as an effective non-invasive method has not been established. We undertook a study, in a sheep model of acute brain injury, to assess a new non-invasive brain oximeter. The monitor uses the principles of pulse oximetry to record a pulse and oxygen levels. METHODS: We studied 8 sheep. An acute increase in intracranial pressure was induced with an injection of blood into the cranial vault. The temporal changes in the brain oximeter, intracranial pressure and cerebral perfusion pressure were recorded. Simultaneous conventional skin pulse oximetry was also recorded to assess the possible influence of skin blood flow on the brain oximeter signal. RESULTS: At baseline, a pulsatile waveform consistent with the brain circulation was obtained in 7 animals. The baseline brain pulse was quite distinct from the simultaneous conventional skin pulse and similar in shape to a central venous pressure waveform. Injection of blood into the cranial vault triggered an immediate increase in intracranial pressure and fall in cerebral perfusion pressure, by 60-s cerebral perfusion pressure recovered. The brain oximeter oxygen levels demonstrated similar changes with an immediate fall and recovery by 60 s. Periods of high intracranial pressure were also associated with high-frequency oscillations in the brain pulse waveform; there was, however, no change in the conventional skin pulse oximeter pulse waveform. CONCLUSION: The brain oximeter detected acute changes in both oxygen levels and the brain pulse waveform following an increase in intracranial pressure levels. The brain oximeter could assist clinicians in the management of acute brain injury.

12.
Ann Transl Med ; 5(22): 444, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29264361

RESUMEN

Pneumonia, inhalation trauma and acute respiratory distress syndrome (ARDS), typical causes of lung injury in critically ill patients, are all three characterized by dysregulated inflammation and coagulation in the lungs. Nebulized anticoagulants are thought to have beneficial effects as they could attenuate pulmonary coagulopathy and maybe even affect pulmonary inflammation. A systematic search of the medical literature was performed using terms referring to aspects of the condition ('pneumonia', 'inhalation trauma' and 'ARDS'), the intervention ('nebulized', 'vaporized', and 'aerosolized') and anticoagulants limited to agents that are commercially available and frequently given or tested in critically ill patients ['heparin', 'danaparoid', 'activated protein C' (APC), 'antithrombin' (AT) and 'tissue factor pathway inhibitor' (TFPI)]. The systematic search identified 16 articles reporting on preclinical studies and 11 articles reporting on human trials. All nebulized anticoagulants attenuate pulmonary coagulopathy in preclinical studies using various models for lung injury, but the effects on inflammation are less consistent. Nebulized heparin, danaparoid and TFPI, but not APC and AT also reduced systemic coagulation. Nebulized heparin in lung injury patients shows contradictory results, and there is concern over systemic side effects of this strategy. Future studies need to focus on the way to nebulize anticoagulants, as well as on efficient but safe dosages, and other side effects.

13.
Shock ; 46(3): 287-9, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-27058047

RESUMEN

OBJECTIVES: Measurement of central venous oxygen (SvO2) levels remains an important method for the detection of circulatory shock. Plastic blood gas syringes have supplanted glass. These syringes are, however, permeable to atmospheric oxygen. Common sampling practices, including a delay between blood aspiration and analysis and continuous mixing of the sample, may promote equilibration of the blood sample with atmospheric oxygen and could result in over estimation of SvO2 levels. METHODS: Pulmonary artery or central venous catheter blood samples were taken from 21 critically ill patients. Two venous blood gas samples were collected simultaneously in plastic syringes. One sample was continuously mixed through a gentle rotation. The other sample was not mixed. Blood gas analyses were undertaken on both samples at baseline and at 5, 10, 15, and 20 min. RESULTS: Compared with baseline levels, the SvO2 increased significantly over time for both continuously mixed and nonmixed samples (P < 0.0001). The rate of the increase was 2-fold greater for continuously mixed samples (P < 0.0001). For continuously mixed samples, the SvO2 was 63% at baseline, 65% at 5 min, 70% at 10 min, 74% at 15 min, and 78% at 20 min. For the nonmixed samples, the levels were 63%, 64%, 66%, 68%, and 70%, respectively. CONCLUSIONS: This is the first report documenting that plastic blood gas syringes systematically overestimate SvO2 levels when there is a delay in analysis or continuous mixing of the sample. Overestimation of SvO2 levels may harm patients as circulatory shock may not be recognized and treated.


Asunto(s)
Análisis de los Gases de la Sangre/métodos , Monitoreo Fisiológico/métodos , Oxígeno/sangre , Jeringas , Enfermedad Crítica , Femenino , Humanos , Masculino , Oxígeno/análisis
14.
Ann Intensive Care ; 6(1): 33, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27083915

RESUMEN

Pulmonary coagulopathy is a characteristic feature of lung injury including ventilator-induced lung injury. The aim of this individual patient data meta-analysis is to assess the effects of nebulized anticoagulants on outcome of ventilated intensive care unit (ICU) patients. A systematic search of PubMed (1966-2014), Scopus, EMBASE, and Web of Science was conducted to identify relevant publications. Studies evaluating nebulization of anticoagulants in ventilated patients were screened for inclusion, and corresponding authors of included studies were contacted to provide individual patient data. The primary endpoint was the number of ventilator-free days and alive at day 28. Secondary endpoints included hospital mortality, ICU- and hospital-free days at day 28, and lung injury scores at day seven. We constructed a propensity score-matched cohort for comparisons between patients treated with nebulized anticoagulants and controls. Data from five studies (one randomized controlled trial, one open label study, and three studies using historical controls) were included in the meta-analysis, compassing 286 patients. In all studies unfractionated heparin was used as anticoagulant. The number of ventilator-free days and alive at day 28 was higher in patients treated with nebulized heparin compared to patients in the control group (14 [IQR 0-23] vs. 6 [IQR 0-22]), though the difference did not reach statistical significance (P = 0.459). The number of ICU-free days and alive at day 28 was significantly higher, and the lung injury scores at day seven were significantly lower in patients treated with nebulized heparin. In the propensity score-matched analysis, there were no differences in any of the endpoints. This individual patient data meta-analysis provides no convincing evidence for benefit of heparin nebulization in intubated and ventilated ICU patients. The small patient numbers and methodological shortcomings of included studies underline the need for high-quality well-powered randomized controlled trials.

15.
Trials ; 15: 91, 2014 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-24661817

RESUMEN

BACKGROUND: Pulmonary coagulopathy is a hallmark of lung injury following inhalation trauma. Locally applied heparin attenuates lung injury in animal models of smoke inhalation. Whether local treatment with heparin benefits patients with inhalation trauma is uncertain. The present trial aims at comparing a strategy using frequent nebulizations of heparin with standard care in intubated and ventilated burn patients with bronchoscopically confirmed inhalation trauma. METHODS: The Randomized Controlled Trial Investigating the Efficacy and Safety of Nebulized HEParin versus Placebo in BURN Patients with Inhalation Trauma (HEPBURN) is an international multi-center, double-blind, placebo-controlled, two-arm study. One hundred and sixteen intubated and ventilated burn patients with confirmed inhalation trauma are randomized to nebulizations of heparin (the nebulized heparin strategy) or nebulizations of normal saline (the control strategy) every four hours for 14 days or until extubation, whichever comes first. The primary endpoint is the number of ventilator-free days, defined as days alive and breathing without assistance during the first 28 days, if the period of unassisted breathing lasts for at least 24 consecutive hours. DISCUSSION: As far as the authors know, HEPBURN is the first randomized, placebo-controlled trial, powered to investigate whether local treatment with heparin shortens duration of ventilation of intubated and ventilated burn patients with inhalation trauma. TRIAL REGISTRATION: NCT01773083 (http://www.clinicaltrials.gov), registered on 16 January 2013.Recruiting. Randomisation commenced on 1 January 2014.


Asunto(s)
Anticoagulantes/administración & dosificación , Heparina/administración & dosificación , Pulmón/efectos de los fármacos , Nebulizadores y Vaporizadores , Proyectos de Investigación , Respiración Artificial , Lesión por Inhalación de Humo/terapia , Administración por Inhalación , Anticoagulantes/efectos adversos , Bélgica , Protocolos Clínicos , Método Doble Ciego , Heparina/efectos adversos , Humanos , Intubación Intratraqueal , Pulmón/patología , Pulmón/fisiopatología , Países Bajos , Recuperación de la Función , Respiración , Lesión por Inhalación de Humo/diagnóstico , Lesión por Inhalación de Humo/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Desconexión del Ventilador
16.
J Cardiothorac Vasc Anesth ; 28(2): 242-6, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24439890

RESUMEN

OBJECTIVES: Bleeding into the chest is a major cause of blood transfusion and adverse outcomes following cardiac surgery. The authors investigated predictors of bleeding following cardiac surgery to identify potentially correctable factors. DESIGN: Data were retrieved from the medical records of patients undergoing cardiac surgery over the period of 2002 to 2008. Multivariate analysis was used to identify the independent predictors of chest tube drainage. SETTING: Tertiary hospital. PARTICIPANTS: Two thousand five hundred seventy-five patients. INTERVENTIONS: Cardiac surgery. RESULTS: The individual operating surgeon was independently associated with the extent of chest tube drainage. Other independent factors included internal mammary artery grafting, cardiopulmonary bypass time, urgency of surgery, tricuspid valve surgery, redo surgery, left ventricular impairment, male gender, lower body mass index and higher preoperative hemoglobin levels. Both a history of diabetes and administration of aprotinin were associated with reduced levels of chest tube drainage. CONCLUSIONS: The individual operating surgeon was an independent predictor of the extent of chest tube drainage. Attention to surgeon-specific factors offers the possibility of reduced bleeding, fewer transfusions, and improved patient outcomes.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Tubos Torácicos/estadística & datos numéricos , Drenaje/estadística & datos numéricos , Médicos , Hemorragia Posoperatoria/epidemiología , Anciano , Anciano de 80 o más Años , Antifibrinolíticos/efectos adversos , Antifibrinolíticos/uso terapéutico , Aprotinina/efectos adversos , Índice de Masa Corporal , Puente Cardiopulmonar , Femenino , Hemoglobinas/análisis , Hemoglobinas/metabolismo , Hemostáticos/efectos adversos , Humanos , Masculino , Arterias Mamarias/trasplante , Persona de Mediana Edad , Análisis Multivariante , Hemorragia Posoperatoria/terapia , Arteria Radial/trasplante , Reoperación/estadística & datos numéricos , Factores Sexuales , Válvula Tricúspide/cirugía , Disfunción Ventricular Izquierda/fisiopatología
18.
PLoS One ; 8(2): e55262, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23408962

RESUMEN

BACKGROUND: Critically ill patients frequently develop acute lung injury (ALI). Disturbed alveolar fibrin turnover, a characteristic feature of ALI, is the result of both activation of coagulation and inhibition of fibrinolysis. Nebulized fibrinolytic agents could exert lung-protective effects, via promotion of fibrinolysis as well as anti-inflammation. METHODS: Rats were challenged intratracheally with Pseudomonas aeruginosa, resulting in pneumonia as a model for direct ALI, or received an intravenous bolus infusion of lipopolysaccharide, as a model for indirect ALI. Rats were randomized to nebulization of normal saline (placebo), recombinant tissue plasminogen activator (rtPA), or monoclonal antibodies against plasminogen activator inhibitor-type 1 (anti-PAI-1). RESULTS: Nebulized rtPA or anti-PA1-1 enhanced the bronchoalveolar fibrinolytic system, as reflected by a significant reduction of PAI-1 activity levels in bronchoalveolar lavage fluid, and a consequent increase in plasminogen activator activity (PAA) levels to supranormal values. Both treatments also significantly affected systemic fibrinolysis as reflected by a significant increase in PAA levels in plasma to supranormal levels. Neither nebulized rtPA nor anti-PA1-1 affected pulmonary inflammation. Neither treatment affected bacterial clearance of P. aeruginosa from the lungs in case of pneumonia. CONCLUSIONS: Local treatment with rtPA or anti-PA1-1 affects pulmonary fibrinolysis but not inflammation in models of direct or indirect ALI in rats.


Asunto(s)
Lesión Pulmonar Aguda/tratamiento farmacológico , Modelos Animales de Enfermedad , Fibrinólisis/efectos de los fármacos , Fibrinolíticos/uso terapéutico , Inflamación/tratamiento farmacológico , Animales , Líquido del Lavado Bronquioalveolar , Fibrinolíticos/administración & dosificación , Pulmón/microbiología , Pulmón/patología , Masculino , Nebulizadores y Vaporizadores , Ratas , Ratas Sprague-Dawley
19.
Transfusion ; 53(1): 19-27, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22574710

RESUMEN

BACKGROUND: Bleeding into the chest is a life-threatening complication of cardiac surgery. Blood transfusion has been implicated as an important cause of harm associated with bleeding, based largely on studies demonstrating an independent association between transfusion and mortality. These studies did not, however, consider the possibility that bleeding may in itself be harmful, inasmuch as drains are inefficient at clearing blood from the chest and retained blood may compromise cardiac and lung function. STUDY DESIGN AND METHODS: We undertook a multivariate logistic regression analysis of the risk factors associated with mortality in 2599 consecutive patients undergoing cardiac surgery. Unlike previous studies the risk factors examined included the volume of chest tube drainage at 24 hours. A stratified analysis was also undertaken that compared the adjusted risk of death for patients exposed or not exposed to a postoperative blood transfusion. RESULTS: Blood transfusion was not an independent predictor of mortality (p=0.4). Chest tube drainage was the strongest independent predictor of mortality (p<0.001). In the stratified analysis, chest tube drainage remained an independent predictor of mortality for patients not exposed to a blood transfusion (p<0.01). Furthermore, the risk of death of these patients was no different from patients exposed to a blood transfusion (p=0.7 for interaction). CONCLUSIONS: Our results argue that for patients undergoing cardiac surgery bleeding contributes to mortality through mechanisms unrelated to blood transfusion.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/mortalidad , Reacción a la Transfusión , Anciano , Femenino , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis de Regresión , Estudios Retrospectivos , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA