Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
J Exp Biol ; 227(19)2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-39370919

RESUMEN

Researchers in the Global South (GS, developing countries) make valuable contributions to the field of comparative physiology, but face economic and scientific disparities and several unique challenges compared with colleagues in the Global North (developed countries). This Perspective highlights some of the challenges, knowledge gaps and disparities in opportunity faced by GS researchers, especially those at early-career stages. We propose collaborative solutions to help address these issues, and advocate for promoting investment and cultural and societal change for a more inclusive research community. Additionally, we highlight the role of GS researchers in contributing expert knowledge on local biodiversity and the environment; this knowledge can help to shape the future of comparative physiology, allowing us to achieve a better understanding of the evolution of physiological mechanisms and to develop innovative solutions to environmental and biomedical challenges. With this Perspective, we hope to highlight the need to foster a more diverse, equitable and inclusive research landscape in comparative physiology; one that empowers GS scientists to address the global challenges associated with biodiversity loss, climate change and environmental pollution.


Asunto(s)
Fisiología Comparada , Investigadores , Fisiología Comparada/tendencias , Países en Desarrollo , Biodiversidad , Humanos , Animales , Cambio Climático
2.
BMC Vet Res ; 20(1): 319, 2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-39014383

RESUMEN

BACKGROUND: Monitoring blood oxygenation is essential in immobilised rhinoceros, which are susceptible to opioid-induced hypoxaemia. This study assessed the reliability, clinical performance and trending ability of the Nonin PalmSAT 2500 A pulse oximeter's and the Masimo Radical-7 pulse co-oximeter's dual-wavelength technology, with their probes placed at two measurement sites, the inner surface of the third-eyelid and the scarified ear pinna of immobilised white rhinoceroses. Eight white rhinoceros were immobilised with etorphine-based drug combinations and given butorphanol after 12 min, and oxygen after 40 min, of recumbency. The Nonin and Masimo devices, with dual-wavelength probes attached to the third-eyelid and ear recorded arterial peripheral oxygen-haemoglobin saturation (SpO2) at pre-determined time points, concurrently with measurements of arterial oxygen-haemoglobin saturation (SaO2), from drawn blood samples, by a benchtop AVOXimeter 4000 co-oximeter (reference method). Reliability of the Nonin and Masimo devices was evaluated using the Bland-Altman and the area root mean squares (ARMS) methods. Clinical performance of the devices was evaluated for their ability to accurately detect clinical hypoxemia using receiver operating characteristic (ROC) curves and measures of sensitivity, specificity, and positive and negative predictive values. Trending ability of the devices was assessed by calculating concordance rates from four-quadrant plots. RESULTS: Only the Nonin device with transflectance probe attached to the third-eyelid provided reliable SpO2 measurements across the 70 to 100% saturation range (bias - 1%, precision 4%, ARMS 4%). Nonin and Masimo devices with transflectance probes attached to the third-eyelid both had high clinical performance at detecting clinical hypoxaemia [area under the ROC curves (AUC): 0.93 and 0.90, respectively]. However, the Nonin and Masimo devices with transmission probes attached to the ear were unreliable and provided only moderate clinical performance. Both Nonin and Masimo devices, at both measurement sites, had concordance rates lower than the recommended threshold of ≥ 90%, indicating poor trending ability. CONCLUSIONS: The overall assessment of reliability, clinical performance and trending ability indicate that the Nonin device with transflectance probe attached to the third-eyelid is best suited for monitoring of blood oxygenation in immobilised rhinoceros. The immobilisation procedure may have affected cardiovascular function to an extent that it limited the devices' performance.


Asunto(s)
Oximetría , Oxígeno , Perisodáctilos , Animales , Perisodáctilos/sangre , Oximetría/veterinaria , Oximetría/instrumentación , Oximetría/métodos , Reproducibilidad de los Resultados , Oxígeno/sangre , Masculino , Inmovilización/veterinaria , Inmovilización/instrumentación , Inmovilización/métodos , Femenino
3.
Vet Clin Pathol ; 52(3): 417-421, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37612252

RESUMEN

BACKGROUND: Enterprise Point-of-Care (EPOC) blood analysis is used routinely in wildlife veterinary practice to monitor blood oxygenation, but the reliability of the EPOC calculated arterial oxygen-hemoglobin saturation (cSaO2 ) has never been validated in the white rhinoceros (Ceratotherium simum), despite their susceptibility to hypoxemia during chemical immobilization. OBJECTIVES: We aimed to evaluate the reliability of the EPOC cSaO2 by comparing it against arterial oxygen-hemoglobin saturation (SaO2 ) measured by a co-oximeter reference method in immobilized white rhinoceroses. METHODS: Male white rhinoceroses in two studies (both n = 8) were immobilized by darting with different etorphine-based drug combinations, followed by butorphanol or saline (administered intravenously). Animals in both studies received oxygen via intranasal insufflation after 60 min. Blood samples were drawn, at predetermined time points, from a catheter inserted into the auricular artery and analyzed using the EPOC and a co-oximeter. Bland-Altman (to estimate bias and precision) and area root mean squares (ARMS) plots were used to determine the reliability of the EPOC cSaO2 compared with simultaneous co-oximeter SaO2 readings. RESULTS: The rhinoceros were acidotic (pH of 7.3 ± 0.1 [mean ± standard deviation]), hypercapnic (PaCO2 of 73.7 ± 10.5 mmHg), and normothermic (body temperature of 37.4 ± 1.8°C). In total, 389 paired cSaO2 -SaO2 measurements were recorded (the cSaO2 ranged between 13.2% and 99.0%, and the SaO2 ranged between 11.8% and 99.9%). The EPOC cSaO2 readings were unreliable (inaccurate, imprecise, and poor ARMS) across the entire saturation range (bias -6%, precision 5%, and ARMS 8%). CONCLUSIONS: The EPOC cSaO2 is unreliable and should not be used to monitor blood oxygenation in immobilized white rhinoceroses.


Asunto(s)
Oxígeno , Sistemas de Atención de Punto , Masculino , Animales , Reproducibilidad de los Resultados , Arterias , Animales Salvajes
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA