Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
Front Med (Lausanne) ; 10: 1295277, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38111699

RESUMEN

Background: Endotracheal suctioning of mechanically ventilated patients differs across the world. In many low and middle-income countries, endotracheal suctioning is often performed with a sterile suctioning catheter that is used for 12 h or during the length of one nursing shift. The effect of flushing multiple used endotracheal suction system with chlorhexidine after suctioning to reduce ventilator associated pneumonia (VAP) remains unclear. Aim: The aim of the study is to assess the effectiveness of flushing multiple-used open endotracheal suction catheters and suctioning system with chlorhexidine gluconate 0.2% to reduce VAP in mechanically ventilated patients in a resource-limited Intensive Care Unit (ICU). Methods: Due to the difficulty of blinding the intervention for nurses who perform endo-tracheal suction procedures, we adopted a quasi-experimental method with a randomized controlled trial design. A sample of 136 ICU patients were allocated to the intervention (n = 68) or control group (n = 68) between May and November 2020. The intervention was flushing the multiple-used suction catheter and suction system with 40ml chlorhexidine gluconate 0.2% and in the control group we used normal saline to flush the catheter and suction system. The primary outcome was incidence of VAP and the cost of the flushing solutions was the secondary outcome measure. Results: Patients in the intervention group had a lower incidence of VAP compared to patients in the control group; 15 (22.1%) vs 29 (42.6%), p = 0.01. The incidence of late-onset VAP was 26.2% in the intervention group and 49% in the control group (p = 0.026) and the early-onset VAP was 13.2% in the intervention group and 25% in the control group (p = 0.081). Chlorhexidine gluconate 0.2% reduced the cost of suction system flushing (median: 78.4 vs 300 EGP, p < 0.001). Conclusion: Using chlorhexidine gluconate 0.2% to flush multiple-used suctioning catheters after every endo-tracheal suction procedure might reduce the incidence of VAP in mechanically ventilated patients. Chlorhexidine gluconate 0.2% can be a cost-effective solution for flushing the suction circuit. Nurses working in resource-limited ICUs and using suctioning catheters multiple times might consider using chlorhexidine gluconate 0.2% instead of normal saline or distilled water when flushing the suction system. Clinical trial registration: ClinicalTrials.gov, identifier NCT05206721.

2.
Cureus ; 15(10): e46746, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38022326

RESUMEN

Background This study aims to evaluate the accuracy of volumetric measurements of three-dimensional (3D)-printed human condyles from cone-beam computed tomography (CBCT) in comparison to physical condyles using a water displacement test. Methodology A sample of 22 dry condyles was separated from the mandibular body by disc, mounted on a base made of casting wax, and scanned using the SCANORA (Scanora 3DX, Soredex, Finland) CBCT scanner. Subsequently, the projection data were reconstructed with the machine-dedicated OnDemand 3D (Cybermed Co., Seoul, Korea). The Standard Tessellation Language file was prepared for 3D printing using chitubox slicing software v1.9.1. Frozen water-washable gray resin was used for 3D printing. All condyles were printed using the same parameters and the same resin. The volumetric measurements were then performed using a customized modified pycnometer based on water volume and weight displacement. Volumetric measures were performed for both the physical human condyles and the 3D-printed replicas and the measurements were then compared. Results The volume of dry condyles using the water displacement method showed an average (±SD) of 1.925 ± 0.40 cm3. However, the volume of 3D-printed replicas using the water displacement method showed an average (±SD) of 2.109 ± 0.40 cm3. The differences in measurements were insignificant (p > 0.05), as revealed by an independent t-test. Conclusions Highly precise, accurate, and reliable CBCT for volumetric mandibular condyle was applied for measurements of a human condyle and 3D-printed replica. The modified pycnometer for volumetric measurements presented an excellent volumetric measure based on a simple water displacement device. The tested modified pycnometer can be applied in volumetric measurements in both 3D-printed and mandibular condyle. For best accuracy, the highest scanning resolution possible should be used. As it directly handles irregularly shaped solid objects in a non-destructive manner with a high level of precision and reliability, this 3D scanning approach may be seen as a superior alternative to the current measurement methods.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA