Clin Chim Acta ; 522: 31-35, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34352282

RESUMEN

BACKGROUND: Hemoglobin C, D Punjab, E or S trait can interfere with hemoglobin A1c (HbA1c) results. We assessed whether they affect results obtained with 15 current assay methods. METHODS: Hemoglobin AA (HbAA), HbAC, HbAD Punjab, HbAE and HbAS samples were analyzed on 2 enzymatic, 4 ion-exchange HPLC and 9 immunoassay methods. Trinity Premier Hb9210 boronate affinity HPLC was the comparative method. An overall test of coincidence of least-squared linear regression lines was performed to determine if HbA1c results were statistically significantly different from those of HbAA samples. Clinically significant interference was defined as >6% difference from HbAA at 6 or 9% HbA1c compared to Premier Hb9210 using Deming regression. RESULTS: All methods showed statistically significant effects for one or more variants. Clinically significant effects were observed for the Tosoh G11 variant mode (HbAD), Roche b 101 (HbAC and HbAE) and Siemens DCA Vantage (HbAE and HbAS). All other methods (Beckman Coulter B93009 and B00389 on DxC700AU, and Unicel DxC, Ortho Clinical Vitros 5.1, Roche cobas c 513, Siemens Dimension RxL and Vista, and Enzymatic on Advia and Atellica, Tosoh G8 5.24 and 5.28, and GX) showed no clinically significant differences. CONCLUSIONS: A few methods showed interference from one or more variants. Laboratories need to be aware of potential HbA1c assay interferences.


Asunto(s)
Pruebas Hematológicas , Hemoglobina C , Cromatografía Líquida de Alta Presión , Hemoglobina Glucada/análisis , Humanos , Inmunoensayo
2.
Diagn Microbiol Infect Dis ; 101(2): 115458, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34274751

RESUMEN

We describe an extractionless real-time reverse transcriptase-PCR (rRT-PCR) protocol for SARS-CoV-2 nucleic acid detection using heat as an accurate cost-effective high-capacity solution to COVID-19 testing. We present the effect of temperature, transport media, rRT-PCR mastermixes and gene assays on SARS-CoV-2 gene amplification and limits of detection. Utilizing our heated methodology, our limits of detection were 12.5 and 1 genome copy/reaction for singleplex E- and N1-gene assays, respectively, and 1 genome copy/reaction by utilizing an E/N1 or Orf1ab/N1 multiplex assay combination. Using this approach, we detected up to 98% of COVID-19 positive patient samples analyzed in our various cohorts including a significant percentage of weak positives. Importantly, this extractionless approach will allow for >2-fold increase in testing capacity with existing instruments, circumvent the additional need for expensive extraction devices, provide the sensitivity needed for COVID-19 detection and significantly reduce the turn-around time of reporting COVID-19 test results.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , SARS-CoV-2/aislamiento & purificación , Prueba de Ácido Nucleico para COVID-19/normas , Fluorescencia , Calor , Humanos , Reacción en Cadena de la Polimerasa Multiplex , SARS-CoV-2/genética , Sensibilidad y Especificidad , Manejo de Especímenes , Proteínas Virales/genética
3.
Clin Biochem ; 95: 84-88, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33964271

RESUMEN

BACKGROUND: The diagnosis of alpha-1-antitrypsin (A1AT) deficiency has been hindered by obscurity concerning the testing process and treatment implications. In this study, we aimed to identify regional differences in the diagnostic rates for A1AT deficiency in the western Canadian provinces of British Columbia (BC) and Alberta (AB). METHODS: The number of A1AT deficiency variant genotype (ZZ, SZ, MZ, SS, and MS) diagnoses were reviewed for BC and AB. The regional diagnostic rates for A1AT deficiency variants in these two provinces, normalized for the predicted population prevalence of each variant genotype, was defined as the annual provincial diagnostic rate (APDR) for a given variant genotype. Sex specific variations in the mean age at diagnosis for the five variant genotypes were compared both within and between provinces. RESULTS: The SZ and MZ genotype APDRs were significantly increased in the AB population compared to the BC population. The SS and MS APDRs were similar between AB and BC. There was a significantly decreased mean age of diagnosis for AB males, as compared to BC males (for the SZ, MS, and MZ genotypes) and as compared to AB females (for the MS, MZ, and SS genotypes). There were no significant differences in the mean age of diagnosis between the females and males in BC, or between females in AB and BC, for any genotype. CONCLUSION: The notably higher APDR for more severe A1AT deficiency genotypes, and lower mean age of diagnosis for most variant genotypes in AB males, deserves further investigation to determine the explanation(s) for these differences.


Asunto(s)
Deficiencia de alfa 1-Antitripsina/diagnóstico , Deficiencia de alfa 1-Antitripsina/genética , alfa 1-Antitripsina/genética , Factores de Edad , Alberta/epidemiología , Colombia Británica/epidemiología , Femenino , Genotipo , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores Sexuales , alfa 1-Antitripsina/sangre , Deficiencia de alfa 1-Antitripsina/sangre
5.
Clin Biochem ; 81: 27-33, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32387440

RESUMEN

BACKGROUND: Laboratory confirmation of alpha-1-antitrypsin (A1AT) deficiency may be achieved by multiple methods. Here, we compare the relative comprehensiveness and efficiency of pathogenic variant (PV) detection of four different protocols utilized at different diagnostic centres in Canada. METHODS: Diagnostic results from 2011 to 2018 at clinical laboratories in British Columbia (BC), Alberta (AB), Ontario (ON), and Québec (QC) were reviewed. The four labs utilize the following protocols: BC-CGID (serum A1AT Concentration/Genotyping/Isoelectric focussing (IEF)/SERPINA1 DNA sequencing), AB-CID (serum A1AT Concentration/IEF/DNA sequencing), ON-CD (serum A1AT Concentration/DNA sequencing), and QC-G (Genotyping). As the respective catchment areas varied in size and ethnic composition, the comprehensiveness of PV detection was assessed by comparing the frequency of individual genotypes to the ZZ genotype, which is clearly identified by all protocols. RESULTS: Collectively 5399 index patients were tested identifying 396 ZZ genotypes. Serum A1AT concentration as a determinant of further testing efficiently identified PV. ON-CD had the highest detection rate for PV; genotypes with at least one PV, other than S, Z or F, were identified at 0.67/ZZ as compared to <0.2/ZZ (all others). However, ON-CD had the highest rates of undefined molecular variants (UMV) (0.16/ZZ) or likely benign variants (LBV) (0.08/ZZ), compared to all others (<0.12/ZZ and < 0.06/ZZ, respectively). The F variant was identified at 0.10/ZZ, only in the ON-CD and the AB-CID protocols. Collectively, MMalton was the next most common variant, identified as a compound heterozygous genotype at 0.04/ZZ, only in the ON-CD and BC-CGID protocols. CONCLUSION: Strategies which readily detect variants across the full coding sequence of SERPINA1 detect more PV as well as more UMV and LBV.


Asunto(s)
Heterocigoto , Técnicas de Diagnóstico Molecular/normas , Mutación , Análisis de Secuencia de ADN/métodos , Deficiencia de alfa 1-Antitripsina/diagnóstico , alfa 1-Antitripsina/genética , Canadá/epidemiología , Genotipo , Humanos , Fenotipo , Estudios Retrospectivos , alfa 1-Antitripsina/sangre , Deficiencia de alfa 1-Antitripsina/epidemiología , Deficiencia de alfa 1-Antitripsina/genética
6.
Clin Biochem ; 79: 23-27, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32087139

RESUMEN

BACKGROUND: α1-Antitrypsin (A1AT) deficiency predisposes patients to pulmonary disease due to inadequate protection against human neutrophil elastase released during inflammatory responses. A1AT deficiency is caused by homozygosity or compound heterozygosity for A1AT variants; individuals with A1AT deficiency most commonly have at least one Z variant allele (c.1096G > A (Glu366Lys)). Null variants that result in complete absence of A1AT in the plasma are much rarer. With one recent exception, all reported A1AT variants are characterized by a single pathogenic variant. CASE: An 8 years old patient from Edmonton, Alberta, Canada, was investigated for A1AT deficiency. His A1AT phenotype was determined to be M (wild type)/Null by isoelectric focusing (IEF) but M/Z by targeted genotyping. Gene sequencing revealed two heterozygous variants: Z and Ile100Asn (c.299 T > A). The Ile100Asn substitution is predicted to disrupt the secondary structure of an α-helix in which it resides and the neighbouring tertiary structure, resulting in intracellular degradation of A1AT prior to hepatocyte secretion. METHODS: Family testing was conducted to verify potential inheritance of an A1AT allele carrying the two mutations in cis, as this arrangement of the mutations would explain "Z" detection by genotyping but not by IEF. Molecular modeling was used to assess the effect of the variants on A1AT structure and stability. DISCUSSION: Carrier status for a novel variant NullCanada with in cis mutations (c.[299 T > A;1096G > A], p.[(Ileu100Asn;Glu366Lys)]) was confirmed. A sibling was identified as having A1AT deficiency on the basis of compound heterozygosity for two alleles: NullCanada and the common Z allele. A separate pedigree from the Maritimes was subsequently recognized as carrying NullCanada. CONCLUSION: In cis mutations such as NullCanada may be more common than previously described due to failure to detect such mutations using historical testing methods. Combined approaches that include gene sequencing and segregation studies allow recognition of rare A1AT variants, including in cis mutations.


Asunto(s)
Alelos , Mutación Missense , Deficiencia de alfa 1-Antitripsina/genética , alfa 1-Antitripsina/genética , Alberta , Niño , Genotipo , Heterocigoto , Homocigoto , Humanos , Focalización Isoeléctrica , Masculino , Linaje , Conformación Proteica en Hélice alfa , Estructura Terciaria de Proteína , Proteolisis , Reacción en Cadena en Tiempo Real de la Polimerasa , alfa 1-Antitripsina/sangre , alfa 1-Antitripsina/química , Deficiencia de alfa 1-Antitripsina/sangre
7.
Clin Biochem ; 78: 25-31, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31743687

RESUMEN

OBJECTIVES: Previous analytical evaluations of the Beckman Coulter Access high sensitivity troponin (hsTn) I assay have focused on single platforms and laboratory sites. The purpose of this study was to determine assay robustness across different platforms at multiple sites, platform-specific characteristics, and equivalence to other hsTn methods in a large laboratory network. METHODS: Barricor plasma was used to assess imprecision, linearity, sensitivity (limit of blank and detection, LOB/LOD), and comparability to the conventional AccuTnI+3 and other hsTn assays. Various studies were conducted across a total of 9 laboratories using Beckman DxI800 and Access2 platforms. RESULTS: Within-laboratory precision was <10% across all target patient pool concentrations, however, DxI800 mean values were 20% higher than Access2 in the range of 3.6-44.9 ng/L. LOBs and LODs were lower on DxI800, 0.27 and 0.90 ng/L, respectively, compared to 2.9 and 3.2 ng/L, on Access2. Both showed excellent linearity across the full range. In method comparison to AccuTnI+3, DxI800 had a higher slope (0.9417 versus 0.8495) and positive bias (+18.1% versus -9.9%) compared to Access2, a trend further pronounced at concentrations <150 ng/L. At values <150 ng/L, there was good agreement with Abbott hsTnI (slope = 1.017, r = 0.932), but poor agreement with the Roche hsTnT assay (slope = 1.687, r = 0.589). Inter-laboratory split sample comparisons across 2 DxI800 and 7 Access2 sites showed close agreement, except at low concentrations <10 ng/L where DxI800 was 2.8 ng/L higher (p<0.001). CONCLUSIONS: The Beckman hsTnI assay showed robust analytical performance across different laboratories and platforms. However, discrepancies between platforms were found at low concentrations where rapid acute myocardial infarction (AMI) rule-out decisions occur. These differences have important implications for AMI risk assessment, suggesting that laboratories should develop platform-specific parameters rather than using them interchangibly.


Asunto(s)
Análisis Químico de la Sangre/métodos , Troponina I/sangre , Biomarcadores/sangre , Femenino , Humanos , Límite de Detección , Masculino , Sensibilidad y Especificidad
8.
J Appl Lab Med ; 3(5): 764-774, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-31639752

RESUMEN

BACKGROUND: Cardiac troponin I (cTnI) 99th percentile cutoffs, used in the diagnosis of acute myocardial infarction, are not standardized across cTnI assays. We compared 3 point-of-care (POC) and 1 central laboratory contemporary cTnI assays against the Abbott high-sensitivity (hs) cTnI to evaluate the analytical concordance and the feasibility of using a single cutoff value for all assays. METHODS: Fresh blood samples collected from 102 inpatients in the coronary care unit were measured on central laboratory instruments (Beckman Coulter DxI AccuTnI+3 TnI, Abbott Architect hs-TnI) and cTnI POC analyzers (Alere Triage Troponin I, Radiometer AQT90, Abbott i-STAT). Agreement and correlation between the contemporary cTnI assays and hs-cTnI assay were assessed using regression analysis. Proportional bias was assessed using Bland-Altman plots. Concordance between the contemporary cTnI and hs-cTnI assays was determined by diagnostic contingency tables at specific cutoffs. RESULTS: Most POC cTnI assays had excellent correlation with the Abbott hs-cTnI method (r 2 = 0.955-0.970) except for Alere Triage (r 2 = 0.617), while proportional bias is evident between all cTnI assays. Overall concordance between POC contemporary cTnI assays and hs-cTnI assay was 80% to 90% at their respective 99th percentile cutoffs. The concordance increased to 90% to 95% when a fixed cutoff of 0.03 to 0.05 ng/mL was used across the assays. CONCLUSIONS: This study demonstrates poor analytical concordance between cTnI assays at the 99th percentile and supports the notion of a single clinical decision limit for cTnI and consequently standardization of diagnostic protocols despite the analytical differences among these assays.


Asunto(s)
Biomarcadores/sangre , Laboratorios/normas , Infarto del Miocardio/sangre , Infarto del Miocardio/diagnóstico , Sistemas de Atención de Punto/estadística & datos numéricos , Troponina I/sangre , Troponina T/sangre , Bioensayo , Femenino , Humanos , Masculino , Triaje/estadística & datos numéricos
9.
Can Urol Assoc J ; 13(12): 406-411, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31364974

RESUMEN

INTRODUCTION: Asymptomatic microscopic hematuria (AMH) is defined in the Canadian Urological Association (CUA) guideline as >2 red blood cells (RBCs) per high-powered field (HPF). Our objective was to evaluate guideline adherence for AMH at our center. Secondarily, we aimed to identify areas of the guideline that can be optimized. METHODS: We retrospectively reviewed 875 consecutive adults referred to two urologists for hematuria between June 2010 and June 2016. Patient characteristics, risk factors, and outcomes were added to an encrypted Research Electronic Data Capture (REDCap) database. Evaluation of microscopic hematuria reporting was performed by analyzing 681 urine samples reported as 1-5 RBC/HPF. Healthcare costs were obtained from Alberta Health Services (AHS), Data Integration and Management Repository (DIMR), and Alberta Society of Radiologists (ASR). RESULTS: Of the 875 patients referred with hematuria, 400 had AMH. Overall, 96.5% completed evaluation consistent with the CUA guideline. The incidence of pathology requiring surgical intervention was 21/400 (5%) with a 0.8% rate (3/400) of urothelial cell carcinoma (UCC) (non-invasive, low-grade). No malignancy was found in non-smokers with normal cytology, normal imaging and <50 RBC/HPF; 44% had AMH in the 1-5 RBCs/HPF range. Only 41% (279/681) of urine samples categorized as 1-5 RBCs/ HPF had guideline-defined microscopic hematuria. By changing local microscopic hematuria reporting to differentiate 1-2 and 3-5 RBCs/HPF, we estimate $745 000 in annual savings. CONCLUSIONS: At our center, CUA AMH guideline adherence is high. We did not find malignancy in non-smokers with normal cytology, imaging and <50 RBC/HPF. We identified and changed regional microscopic hematuria reporting to fit the CUA definition, eliminating unnecessary investigations and healthcare costs.

10.
Pract Lab Med ; 14: e00116, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30733990

RESUMEN

OBJECTIVES: Many hospitals cannot afford an hCG assay on a central lab analyzer and turn to point of care testing (POCT) solutions. The Radiometer AQT90 FLEX is a small benchtop immunoareement between the AQT90 and comparator methods for samples with hCG ssay analyzer for use in the laboratory or at the patient bedside. This study evaluated the analytical performance of the AQT90's ßhCG assay. METHODS: Precision was assessed using whole blood patient samples and two levels of quality control. Linearity was assessed by dilution of a high hCG plasma sample. Carryover and hook effect were assessed using high and low hCG samples. Method comparisons were done against Abbott i-STAT Total ßhCG, Beckman Coulter Total ßhCG (5th IS), and Roche hCG+ß. Sample concentrations ranged from<2 IU/L to 4,973 IU/L. RESULTS: Repeatability and within-laboratory precision passed most manufacturer's claims and allowable error criteria. Linearity was validated from<2 IU/L to 4,741 IU/L. Hook effect was not observed up to 2,446,448 IU/L. Carryover was<4.0 ppm. A linear relationship was observed with i-STAT, Beckman and Roche methods. At>20 IU/L, biases were apparent against all three comparator assays (i-STAT: +20%, Roche: +30%, Beckman: +5 to 15%). At ≤20 IU/L, the acceptability of agreement varied according to TAE specifications. Concordance between AQT90 and comparator assays using 5 IU/L as the medical decision level ranged from 69% to 81%. CONCLUSIONS: Overall, the AQT90 hCG assay performed well and would be suitable for smaller suburban or rural hospitals. Some limitations have been noted and should be kept in mind during clinical testing.

12.
Clin Biochem ; 51: 80-84, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28916438

RESUMEN

BACKGROUND: Serum protein electrophoresis (SPE) and immunofixation electrophoresis (IFE) are used in the diagnosis and monitoring of plasma cell dyscrasias. IFE is considered the most sensitive method for the detection of monoclonal proteins (M-proteins), but it is not quantitative. The goal of this study was to establish the analytical sensitivity and diagnostic performance of SPE on the Sebia Hydrasys using HYDRAGEL 30 PROTEIN(E) ß1-ß2. METHODOLOGY: Patient sera with a previously identified M-protein (IgG, IgA or IgM) were serially diluted with a normal serum pool and electrophoresed on the Sebia Hydrasys using HYDRAGEL 30 PROTEIN(E) ß1-ß2. The SPE gels were individually interpreted by five independent observers and IFE was performed on selected samples. Limit of detection was determined as the lowest concentration of M-protein band visible on the gel. SPE diagnostic performance was evaluated against the "gold standard" IFE according CLSI EP12-A2 guidelines. RESULTS: Detection limit was comparable among all M-proteins migrating in the gamma region, IgG-κ (0.18±0.08g/L; n=6), IgG-λ (0.36±0.25g/L; n=8), IgA-κ (0.40±0.13g/L; n=7), IgA-λ (0.37±0.23g/L; n=4), IgM-κ (0.47±0.20g/L; n=13) and IgM-λ (0.29±0.24g/L; n=6). Percentage agreement with IFE for IgG and IgA in the gamma region ranged from 65% to 100%, whereas IgM migrating in the gamma region and immunoglobulins co-migrating with alpha or beta globulins, showed poor (0-38%) agreement. CONCLUSIONS: This study evaluates the analytical sensitivity and diagnostic performance of SPE on the Sebia Hydrasys using HYDRAGEL 30 PROTEIN(E) ß1-ß2. There was acceptable agreement between SPE and IFE for IgG-κ/λ and IgA-κ/λ migrating in the gamma region, suggesting that repeating IFE for samples with these isotypes, when the previous IFE and second SPE are both negative, may not be necessary.


Asunto(s)
Electroforesis de las Proteínas Sanguíneas/instrumentación , Inmunoglobulina A/sangre , Inmunoglobulina G/sangre , Electroforesis de las Proteínas Sanguíneas/normas , Humanos , Límite de Detección , Paraproteinemias/sangre , Paraproteinemias/diagnóstico , Sensibilidad y Especificidad
13.
J Cyst Fibros ; 17(1): 121-124, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-28648493

RESUMEN

OBJECTIVE: To determine whether serum fructosamine correlates with glycemic control and clinical outcomes in patients being screened for cystic fibrosis-related diabetes (CFRD). METHODS: Fructosamine and percent predicted forced expiratory volume in 1s (FEV1) were measured in patients undergoing a 2h oral glucose tolerance test (OGTT) for CFRD screening. Fractional serum fructosamine (FSF) was calculated as fructosamine/total protein. RESULTS: FSF exhibited a positive correlation with 2h OGTT results (r2=0.3201, p=0.009), and ROC curve analysis suggested that FSF can identify patients with an abnormal OGTT (AUC=0.840, p=0.0002). FSF also exhibited a negative correlation with FEV1 (r2=0.3732, p=0.035). Patients with FSF≥3.70µmol/g had significantly lower FEV1 (median 47%) compared to those with FSF<3.70µmol/g (median 90%; p=0.015). CONCLUSIONS: FSF correlated with both OGTT results and FEV1, and reliably identified patients with abnormal OGTT results. This simple blood test shows potential as an effective tool in CFRD screening.


Asunto(s)
Fibrosis Quística , Diabetes Mellitus , Volumen Espiratorio Forzado , Fructosamina/sangre , Tamizaje Masivo/métodos , Adulto , Canadá , Correlación de Datos , Fibrosis Quística/sangre , Fibrosis Quística/complicaciones , Fibrosis Quística/diagnóstico , Diabetes Mellitus/sangre , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/etiología , Femenino , Prueba de Tolerancia a la Glucosa/métodos , Hemoglobina Glucada/análisis , Humanos , Masculino , Reproducibilidad de los Resultados , Pruebas de Función Respiratoria/métodos
15.
Clin Chem Lab Med ; 55(12): 1898-1906, 2017 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-28306523

RESUMEN

BACKGROUND: Inappropriate laboratory test utilization can result in unnecessary patient testing and increased healthcare costs. While several thyroid function tests are available, thyroid-stimulating hormone (TSH) is recommended as the first-line test for investigating and monitoring thyroid dysfunction. We evaluate thyroid test utilization in Northern Alberta in terms of testing patterns, frequencies, and reflex cutpoints. METHODS: This retrospective study analyzed thyroid test requests from January to December 2014. Each request was designated as appropriate or potentially inappropriate as per clinical practice guidelines and Choosing Wisely recommendations, and the frequencies of each testing pattern were calculated. Sub-analysis was performed to categorize testing patterns based on physician specialty. The number of test requests per patient was determined to assess the appropriateness of testing frequency. Receiver operating characteristic (ROC) curves were generated to define optimal TSH cutpoints for automatic reflex to FT4 testing. RESULTS: Of 752,217 test requests, approximately 10% were potentially inappropriate in terms of testing patterns. Free thyroxine (FT4) and free triiodothyronine (FT3) requested with TSH accounted for 59% of all potentially inappropriate test requests, and 49% of requests from endocrinologists (ENDO) were potentially inappropriate, occurring most frequently among those with less experience. Excessive testing frequencies were observed in 869 patients, accounting for 9382 test requests. Adjustment of our TSH reflex cutpoint would significantly increase specificity for identifying a low FT4 without compromising sensitivity. CONCLUSIONS: This study suggests that questionable testing patterns, excessive testing frequencies, and suboptimal reflexive testing cutpoints contribute to inappropriate thyroid test utilization.


Asunto(s)
Pruebas de Función de la Tiroides , Tirotropina/análisis , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Persona de Mediana Edad , Curva ROC , Estudios Retrospectivos , Adulto Joven
16.
J Appl Lab Med ; 1(5): 544-561, 2017 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-33379796

RESUMEN

BACKGROUND: We examined the concordance of 13 commercial cardiac troponin (cTn) assays [point-of-care, high-sensitivity (hs), and conventional] using samples distributed across a continuum of results. METHODS: cTnI (11 assays) and cTnT (2 assays) were measured in 191 samples from 128 volunteers. cTn assays included Abbott (iSTAT, STAT, and hs), Alere (Cardio 3), Beckman (AccuTnI+3), Pathfast (cTnI-II), Ortho (Vitros), Siemens (LOCI, cTnI-Ultra, Xpand, Stratus CS), and Roche [4th Generation (Gen), hs]. Manufacturer-derived 99th percentile cutoffs were used to classify results as positive or negative. Alternative 99th percentile cutoffs were tested for some assays. Correlation was assessed using Passing-Bablok linear regression, bias was examined using Bland-Altman difference plots, and concordance/discordance of each method comparison was determined using the McNemar method. RESULTS: Regression slopes ranged from 0.63 to 1.87, y-intercepts from 0.00 to 0.03 ng/mL, and r values from 0.93 to 0.99. The cTnT methods had a slope of 0.93, y-intercept of 0.02 ng/mL, and r value of 0.99. For the cTnI assays, positive, negative, and overall concordance was 76.2%-100%, 66.0%-100%, and 82.9%-98.4%, respectively. Overall concordance between the 4th Gen cTnT and hsTnT assays was 88.9%. A total of 30 of the 78 method comparisons showed significant differences in classification of samples (P <0.001); the iSTAT showed 10, hsTnT showed 9, AccuTnI+3 showed 5, Xpand showed 5, and Stratus CS showed 1. Using alternative 99th percentile cutoffs to those listed by manufacturers lowered the method discordance by 6-fold, from 30 to 5 (all involved iSTAT). CONCLUSIONS: These data provide insight into characteristics of cTn methods and will assist the healthcare community in setting expectations for relationships among commercial cTn assays.

18.
Clin Chim Acta ; 462: 153-157, 2016 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-27664335

RESUMEN

BACKGROUND: HbA1c is used in the diagnosis and monitoring of diabetes mellitus (DM). Interference from hemoglobin variants is a well-described phenomenon, particularly with HPLC-based methods. While immunoassays may generate more reliable HbA1c results in the presence of some variants, these methods are susceptible to negative interference from high concentrations of HbF. We report a case where an accurate HbA1c result could not be obtained by any available method due to the presence of a compound hemoglobinopathy. METHODS: HbA1c was measured by HPLC, immunoassay, and capillary electrophoresis. Hemoglobinopathy investigation consisted of a CBC, hemoglobin fractionation by HPLC and electrophoresis, and molecular analysis. RESULTS: HbA1c analysis by HPLC and capillary electrophoresis gave no result. Analysis by immunoassay yielded HbA1c results of 5.9% (Siemens DCA 2000+) and 5.1% (Roche Integra), which were inconsistent with other markers of glycemic control. Hemoglobinopathy investigation showed HbC with the hereditary persistence of fetal hemoglobin-2 Ghana deletion. CONCLUSION: Reliable HbA1c results may be unobtainable in the presence of some hemoglobinopathies. HPLC and capillary electrophoresis alerted the laboratory to the presence of an unusual hemoglobinopathy. Immunoassays generated falsely low results without warning, which could lead to missed diagnoses and under treatment of patients with DM.


Asunto(s)
Hemoglobina Fetal/análisis , Hemoglobina Glucada/análisis , Hemoglobina C/análisis , Hemoglobinopatías/sangre , Adulto , Cromatografía Líquida de Alta Presión , Cromatografía por Intercambio Iónico , Electroforesis Capilar , Hemoglobina Fetal/genética , Hemoglobina C/genética , Hemoglobinopatías/genética , Humanos , Inmunoensayo , Masculino , Reacción en Cadena de la Polimerasa
20.
Clin Biochem ; 49(6): 498-501, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26617061

RESUMEN

OBJECTIVES: To investigate the underlying cause of unexpectedly low HbA1c results (3.3-3.5%) obtained by HPLC in three siblings undergoing routine screening for type 2 diabetes mellitus. DESIGN AND METHODS: HbA1c was measured using an alternate method based on a different analytical principle (the Siemens DCA 2000+ immunoassay). Hemoglobin fractionation was performed by HPLC on the BioRad Variant II, gel electrophoresis at acid and alkaline pH on the Sebia Hydrasys 2, and capillary electrophoresis on the Sebia Capillarys 2. Sequencing of the beta globin gene was also conducted. RESULTS: HbA1c analysis by immunoassay gave significantly higher results, ranging from 5.2-5.5%. Hemoglobin fractionation by HPLC showed an abnormal peak comprising approximately 43% of total hemoglobin, suggesting the presence of a beta chain hemoglobin variant. Gel electrophoresis at alkaline pH revealed a very unusual pattern, with 3 abnormal bands migrating with Hb F, between Hb F and Hb S, and slightly cathodal to Hb S. A single band in the Hb A position was seen on gel electrophoresis at acid pH. Capillary electrophoresis revealed two abnormal peaks, comprising 42% and 5% of total hemoglobin. Sequencing of the beta globin gene showed heterozygosity for Hb Hirose (beta 37(C3) Trp>Ser), an extremely rare variant with a substitution at the α1ß2 interface. CONCLUSIONS: We describe the chromatographic and electrophoretic properties of Hb Hirose, and demonstrate that this rare variant causes falsely low HbA1c results on the BioRad variant II Turbo 2.0. Recognition of this interference is crucial in order to prevent reporting erroneous results.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Hemoglobina Glucada/metabolismo , Hemoglobinas Anormales/análisis , Electroforesis Capilar , Reacciones Falso Positivas , Humanos