Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros




Base de datos
Asunto de la revista
Intervalo de año de publicación
1.
Clin Res Cardiol ; 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38565712

RESUMEN

AIM: Data on associations of invasively determined hemodynamic parameters with procedural success and outcomes in patients suffering from mitral regurgitation (MR) undergoing transcatheter edge-to-edge repair of the mitral valve (M-TEER) is limited. METHODS AND RESULTS: We enrolled 239 patients with symptomatic MR of grade 2 + , who received M-TEER. All patients underwent extensive pre-interventional invasive hemodynamic measurements via right heart catheterization (mean pulmonary arterial pressure (mPAP), systolic- (PAPsys) and diastolic pulmonary arterial pressure (PAPdia), pulmonary arterial wedge pressure (PAWP), a-wave, v-wave, pulmonary vascular resistance (PVR), transpulmonary pressure gradient (TPG), cardiac index (CI), stroke volume index (SVI)). mPAP and PAWP at baseline were neither associated with procedural success, immediate reduction of MR, nor residual MR after 6 months of follow-up. The composite outcome (All-cause mortality (ACM) and/or heart failure induced rehospitalization (HFH)) and HFH differed significantly after M-TEER when stratified according to mPAP, PAWP, PAPdia, a-wave and v-wave. ACM was not associated with the afore mentioned parameters. Neither PVR, TPG, CI nor SVI were associated with the composite outcome and HFH, respectively. In multivariable analyses, PAWP was independently associated with the composite outcome and HFH. PVR and SVI were not associated with outcomes. CONCLUSION: PAWP at baseline was significantly and independently associated with HFH and might serve as a valuable parameter for identifying patients at high risk for HFH after M-TEER. ACM and procedural success were not affected by pulmonary arterial pressure before M-TEER. We suggest that the post-capillary component of PH serves as the driving force behind the risk of HFH.

2.
Catheter Cardiovasc Interv ; 103(1): 137-146, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37890011

RESUMEN

BACKGROUND: The development of the PASCAL transcatheter valve repair system for treating mitral regurgitation (MR) greatly extends therapeutic options. AIMS: To assess the safety, efficacy, and time efficiency of the PASCAL system in transcatheter edge-to-edge repair (TEER) under conscious sedation (CS). METHODS: This is a retrospective, two-center, German registry study consisting of 211 patients who underwent TEER using the PASCAL system under CS. The endpoints were to assess (1) technical, device, and procedural success as per Mitral Valve Academic Research Consortium (MVARC), (2) conversion rate to general anesthesia (GA), (3) hospital length of stay (LoS), (4) New York Heart Association (NYHA) class, and (5) MR compared to baseline at 30-day. RESULTS: A total of 211 patients with a mean age of 78.4 ± 8.9 years, with 51.4% being female and 86.7% belonging to NYHA functional class III/IV and EuroSCORE II 6.3 ± 4.9%, were enrolled. Procedural success attained was 96.9%, and six patients (2.8%) required conversion from CS to GA. At 30 days follow-up, a significant improvement in MR was found in 96 patients (54.2%) patients with 0/1 grade MR and 45 patients (29.5%) were in NYHA functional class III + IV. Moreover, TEER under CS has a short hospital LoS (6.71 ± 5.29 days) and intensive care unit LoS (1.34 ± 3.49 days) with a 2.8% mortality rate. CONCLUSIONS: Performing TEER with the PASCAL system under CS resulted in appreciable (96.9%) procedural success with low mortality and is a safe and promising alternative to GA with positive clinical outcomes.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Sedación Consciente/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Cateterismo Cardíaco
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA