Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Diagn Microbiol Infect Dis ; 110(1): 116371, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38838459

RESUMEN

OBJECTIVES: Vibrio cholerae non-O1/non-O139 (NOVC) bacteremia is infrequently reported in Western countries and is associated with unfavorable outcome. PATIENT/METHOD: We describe here the case of a diabetic patient with hepatic cytolysis and NOVC bacteremia following an episode of diarrhea. RESULT: The patient was paucisymptomatic and had a favorable resolution with oral ciprofloxacin. CONCLUSION: NOVC should be systematically sought in stool samples, particularly in immunocompromised patients, due to an increased risk of infection occurrence.


Asunto(s)
Antibacterianos , Bacteriemia , Vibrio cholerae no O1 , Humanos , Bacteriemia/microbiología , Bacteriemia/tratamiento farmacológico , Francia/epidemiología , Vibrio cholerae no O1/aislamiento & purificación , Vibrio cholerae no O1/genética , Vibrio cholerae no O1/clasificación , Antibacterianos/uso terapéutico , Masculino , Ciprofloxacina/uso terapéutico , Hepatitis/microbiología , Hepatitis/complicaciones , Vibriosis/microbiología , Vibriosis/diagnóstico , Vibriosis/tratamiento farmacológico , Diarrea/microbiología , Cólera/microbiología , Cólera/complicaciones , Persona de Mediana Edad , Heces/microbiología , Anciano , Femenino
2.
Ann Biol Clin (Paris) ; 80(4): 369-384, 2022 07 01.
Artículo en Francés | MEDLINE | ID: mdl-36099352

RESUMEN

Multiparametric toxicology research is mainly based on immunochromatography [IC] and chromatography methods. A new automated method using an immunoenzymatic (IE) assay based on a biochip array technology combines short turning around time and analytical performances close to chromatography in terms of positivity cut-off. The aim of our study was to compare IE versus IC and chromatography methods using urines samples from clinical cases. Seventy-two samples were analyzed by IC (amphetamines, opiates, benzodiazepines, THC, methadone, cocaine), IE and chromatography (previous classes plus opioids and cathinone). Immunochromatography results were read by at least 7 operators to assess reading subjectivity. Immunoenzymatic, IC, and chromatrography results were compared with each other. Chromatographic quantification was analyzed to understand discrepancies. Significant discrepancies (29-64%) were observed between IC and IE for most of the drug families investigated except for benzodiazepines, methadone and opiates. These discrepancies were not identified between IE and chromatography, except for some substances (28% to 67% discrepancies for buprenorphine, tramadol and oxycodone, 100% for cathinone). In contrast to IC, the performance of IE approached those of chromatography, except for some substances for which cross-reactions must be investigated. Reading discrepancies were frequent with IC (33% of samples) and made robust result output challenging. In conclusion, the Multistat® is an interesting method for first-line toxicological screening for laboratories without chromatography method.


La recherche des toxiques multiparamétrique repose principalement sur des méthodes immunochromatographie [IC] et de chromatographie (CL). Une nouvelle méthode automatisée immunoenzymatique (IE) (Multistat®) en biopuce, combine un rendu de résultats rapide et des performances analytiques, en termes de seuils de positivité, proche de la CL. L'objectif de notre étude a été de comparer l'IE à des méthodes d'IC et de CL sur des échantillons hospitaliers. Soixante-douze échantillons ont été analysés par IC (amphétamines, opiacés, benzodiazépines, THC, méthadone, cocaïne), IE et CL (classes précédentes plus opioïdes et dérivés de la cathinone). Les résultats d'IC étaient lus par au moins 7 personnes pour évaluer la subjectivité des lectures. Les résultats d'IE, d'IC et de CL étaient comparés entre eux. La quantification en CL était exploitée pour expliquer les discordances. Une forte proportion de discordances (de 29 à 64 %) était observée entre IC et IE sur la plupart des toxiques explorées sauf pour les benzodiazépines, la méthadone et les opiacés. Ces discordances n'étaient pas retrouvées entre IE et CL, hormis pour certaines substances (28 % à 67 % de divergences pour buprénorphine, tramadol et oxycodone, 100 % pour les dérivés de la cathinone). À l'inverse de l'IC, les performances de l'IE se rapprochaient de celles de la CL, sauf pour certaines substances pour lesquelles des réactions croisées doivent être recherchées. Les discordances de lecture étaient fréquentes en IC et rendent difficile un rendu de résultat robuste. En conclusion, le Multistat® est une méthode intéressante pour un criblage en première intention pour les laboratoires sans CL.


Asunto(s)
Analgésicos Opioides , Alcaloides Opiáceos , Benzodiazepinas , Cromatografía de Afinidad , Cromatografía Liquida/métodos , Humanos , Espectrometría de Masas/métodos , Metadona
3.
Sci Rep ; 10(1): 12265, 2020 07 23.
Artículo en Inglés | MEDLINE | ID: mdl-32703975

RESUMEN

Dolutegravir therapeutic drug monitoring (TDM) could be improved by measuring the unbound dolutegravir plasma concentration (Cu), particularly in patients experiencing virological failure or toxicity despite achieving appropriate DTG total plasma concentrations. Equilibrium dialysis (ED) is the gold standard to measure Cu, but ED is time consuming, precluding its use in clinical practice. In contrast, ultrafiltration is applicable to TDM, but is sensitive to numerous analytical conditions. In order to evaluate measurements of Cu by ultrafiltration, ultrafiltration conditions were validated by comparison with ED. DTG concentrations were measured by LC-MS/MS. Three ultrafiltration factors (temperature, duration and relative centrifugal force [RCF]) were evaluated and compared to ED (25/37 °C), using a design of experiment strategy. Temperature was found to influence Cu results by ED (p = 0.036) and UF (p = 0.002) when results were analysed with ANOVA. Relative centrifugal force (2000 g) and time (20 min) interacted to influence Cu (p = 0.006), while individually they did not influence Cu (p = 0.88 and p = 0.42 for RCF and time). Ultrafiltration conditions which yielded the most comparable results to ED were 37 °C, 1000 g for 20 min. Ultrafiltration results greatly depended on analytical conditions, confirming the need to validate the method by comparison with ED in order to correctly interpret DTG Cu.

4.
Antimicrob Agents Chemother ; 51(12): 4342-50, 2007 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-17709473

RESUMEN

The excision of the staphylococcal chromosomal cassette mec (SCCmec) from methicillin-resistant Staphylococcus aureus (MRSA) strains results in methicillin-susceptible S. aureus (MSSA) strains. In order to determine the proportion and diversity of multidrug-resistant MSSA (MR-MSSA) strains derived from MRSA strains, 247 mecA-negative isolates recovered in 60 French hospitals between 2002 and 2004 were characterized. The spa types of all strains were determined, and a subset of the strains (n = 30) was further genotyped by multilocus sequence typing. The IDI-MRSA assay was used to test the isolates for the presence of the SCCmec element, which was detected in 68% of all isolates analyzed. Molecular analysis of the samples suggested that 92% of the MR-MSSA isolates were derived from MRSA clones of diverse genetic backgrounds, of which the clone of sequence type 8 and SCCmec type IV(A) accounted for most of the samples. High variations in incidence data and differences in the molecular characteristics of the isolates from one hospital to another indicate that the emergence of MR-MSSA resulted from independent SCCmec excisions from epidemic MRSA isolates, as well as the diffusion of methicillin-susceptible strains after the loss of SCCmec. MR-MSSA could constitute a useful model for the study of the respective genetic and environmental factors involved in the dissemination of S. aureus in hospitals.


Asunto(s)
Meticilina/farmacología , Infecciones Estafilocócicas/tratamiento farmacológico , Staphylococcus aureus/efectos de los fármacos , Staphylococcus aureus/genética , Proteínas Bacterianas/genética , Técnicas de Tipificación Bacteriana , Infección Hospitalaria/epidemiología , Infección Hospitalaria/microbiología , Farmacorresistencia Bacteriana Múltiple/genética , Electroforesis en Gel de Campo Pulsado , Francia/epidemiología , Genes Bacterianos/genética , Geografía , Humanos , Pruebas de Sensibilidad Microbiana , Modelos Genéticos , Epidemiología Molecular , Proteínas de Unión a las Penicilinas , Reacción en Cadena de la Polimerasa , Infecciones Estafilocócicas/epidemiología , Infecciones Estafilocócicas/microbiología , Staphylococcus aureus/clasificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA