Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros




Base de datos
Asunto de la revista
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38743528

RESUMEN

This study introduces a contactless blood pressure monitoring approach that combines conventional radar signal processing with novel deep learning architectures. During the preprocessing phase, datasets suitable for synchronization are created by integrating Kalman filtering, multiscale bandpass filters, and a periodic extraction method in the time domain. These data comprise data on chest micro variations, encapsulating a complex array of physiological and biomedical information reflective of cardiac micromotions. The Radar-based Stacked Deformable convolution Network (RSD-Net) integrates channel and spatial self attention mechanisms within a deformable convolutional framework to enhance feature extraction from radar signals. The network architecture systematically employs deformable convolutions for initial deep feature extraction from individual signals. Subsequently, continuous blood pressure estimation is conducted using self attention mechanisms on feature map from single source coupled with multi-feature map channel attention. The performance of model is corroborated via the open-source dataset procured using a non-invasive 24GHz six-port continuous wave radar system. The dataset, encompassing readings from 30 healthy individuals subjected to diverse conditions including rest, the Valsalva maneuver, apnea, and tilt-table examinations. It serves to substantiate the validity and resilience of the proposed method in the non-contact assessment of continuous blood pressure. Evaluation metrics reveal Pearson correlation coefficients of 0.838 for systolic and 0.797 for diastolic blood pressure predictions. The Mean Error (ME) and Standard Deviation (SD) for systolic and diastolic blood pressure measurements are -0.32 ±6.14mmHg and -0.20 ±5.50mmHg, respectively. The ablation study assesses the contribution of different structural components of the RSD-Net, validating their significance in the overall of model performance.

2.
Sensors (Basel) ; 24(7)2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38610238

RESUMEN

The potential of microwave Doppler radar in non-contact vital sign detection is significant; however, prevailing radar-based heart rate (HR) and heart rate variability (HRV) monitoring technologies often necessitate data lengths surpassing 10 s, leading to increased detection latency and inaccurate HRV estimates. To address this problem, this paper introduces a novel network integrating a frequency representation module and a residual in residual module for the precise estimation and tracking of HR from concise time series, followed by HRV monitoring. The network adeptly transforms radar signals from the time domain to the frequency domain, yielding high-resolution spectrum representation within specified frequency intervals. This significantly reduces latency and improves HRV estimation accuracy by using data that are only 4 s in length. This study uses simulation data, Frequency-Modulated Continuous-Wave radar-measured data, and Continuous-Wave radar data to validate the model. Experimental results show that despite the shortened data length, the average heart rate measurement accuracy of the algorithm remains above 95% with no loss of estimation accuracy. This study contributes an efficient heart rate variability estimation algorithm to the domain of non-contact vital sign detection, offering significant practical application value.


Asunto(s)
Aprendizaje Profundo , Frecuencia Cardíaca , Radar , Determinación de la Frecuencia Cardíaca , Algoritmos
3.
Sensors (Basel) ; 24(7)2024 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-38610269

RESUMEN

An increasing number of studies on non-contact vital sign detection using radar are now beginning to turn to data-driven neural network approaches rather than traditional signal-processing methods. However, there are few radar datasets available for deep learning due to the difficulty of acquiring and labeling the data, which require specialized equipment and physician collaboration. This paper presents a new model of heartbeat-induced chest wall motion (CWM) with the goal of generating a large amount of simulation data to support deep learning methods. An in-depth analysis of published CWM data collected by the VICON Infrared (IR) motion capture system and continuous wave (CW) radar system during respiratory hold was used to summarize the motion characteristics of each stage within a cardiac cycle. In combination with the physiological properties of the heartbeat, appropriate mathematical functions were selected to describe these movement properties. The model produced simulation data that closely matched the measured data as evaluated by dynamic time warping (DTW) and the root-mean-squared error (RMSE). By adjusting the model parameters, the heartbeat signals of different individuals were simulated. This will accelerate the application of data-driven deep learning methods in radar-based non-contact vital sign detection research and further advance the field.


Asunto(s)
Pared Torácica , Humanos , Radar , Movimiento (Física) , Movimiento , Simulación por Computador
4.
J Neural Eng ; 20(6)2023 11 23.
Artículo en Inglés | MEDLINE | ID: mdl-37972395

RESUMEN

Objective. The OSort algorithm, a pivotal unsupervised spike sorting method, has been implemented in dedicated hardware devices for real-time spike sorting. However, due to the inherent complexity of neural recording environments, OSort still grapples with numerous transient cluster occurrences during the practical sorting process. This leads to substantial memory usage, heavy computational load, and complex hardware architectures, especially in noisy recordings and multi-channel systems.Approach. This study introduces an optimized OSort algorithm (opt-OSort) which utilizes correlation coefficient (CC), instead of Euclidean distance as classification criterion. TheCCmethod not only bolsters the robustness of spike classification amidst the diverse and ever-changing conditions of physiological and recording noise environments, but also can finish the entire sorting procedure within a fixed number of cluster slots, thus preventing a large number of transient clusters. Moreover, the opt-OSort incorporates two configurable validation loops to efficiently reject cluster outliers and track recording variations caused by electrode drifting in real-time.Main results. The opt-OSort significantly reduces transient cluster occurrences by two orders of magnitude and decreases memory usage by 2.5-80 times in the number of pre-allocated transient clusters compared with other hardware implementations of OSort. The opt-OSort maintains an accuracy comparable to offline OSort and other commonly-used algorithms, with a sorting time of 0.68µs as measured by the hardware-implemented system in both simulated datasets and experimental data. The opt-OSort's ability to handle variations in neural activity caused by electrode drifting is also demonstrated.Significance. These results present a rapid, precise, and robust spike sorting solution suitable for integration into low-power, portable, closed-loop neural control systems and brain-computer interfaces.


Asunto(s)
Neuronas , Procesamiento de Señales Asistido por Computador , Neuronas/fisiología , Algoritmos , Electrodos , Sistemas de Computación , Potenciales de Acción/fisiología
5.
IEEE Trans Neural Netw Learn Syst ; 34(11): 9274-9286, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35312624

RESUMEN

Recently, synchrosqueenzing transform (SST)-based time-frequency analysis (TFA) methods have been developed for achieving the highly concentrated TF representation (TFR). However, SST-based methods suffer from two drawbacks. The first one is that the TFRs are unsatisfactory when dealing with the multicomponent signals, the instantaneous frequencies (IFs) of which are closely adjacent or intersected. Besides, the exhaustive adjustment of window length is required for SST-based methods to obtain the optimal TFR. To tackle these problems, in this article, we first analyze the concentration of TFRs for SST-based methods. A deep learning (DL)-based end-to-end replacement scheme for SST-based methods, named TFA-Net, is then proposed, which learns complete basis functions to obtain various TF characteristics of time series. The 2-D filter kernels are subsequently used for energy concentration. Different from the two-step SST-based methods where the TF transform and energy concentration are separated, the proposed end-to-end architecture makes the basis functions used for extracting TF features more beneficial to energy concentration. The comprehensive numerical experiments are conducted to demonstrate the effectiveness of the TFA-Net. The applications of the proposed method to real-world vital signs, undersea voices and micro-Doppler signatures show its great potential in analyzing nonstationary signals.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA