Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
Ann Med Surg (Lond) ; 86(7): 3880-3886, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38989172

RESUMEN

Background: Syncope is a serious consequence in patients with hypertrophic obstructive cardiomyopathy (HOCM). Percutaneous endocardial septal radiofrequency ablation (PESA) has emerged as a promising intervention to alleviate symptoms and enhance the quality of life for HOCM patients. However, little is known about the effects of PESA on syncope in HOCM. The authors aimed to study the effects of PESA on syncope in patients with HOCM. Materials and methods: Nineteen patients with HOCM and syncope were enrolled. The left ventricular outflow tract gradient (LVOTG) of the patients was more than 50 mmHg despite medication. The participants underwent PESA under the guidance of intracardiac echocardiography (ICE) combined with a three-dimensional electrophysiological mapping system. The patients were followed for 3 (3-5.5) months. Results: The mean age of the patients was 54.8±13.7 years. Out of the 19 participants, 7 (37%) were females. During the follow-up, the syncope was completely alleviated in 14 patients (73.7%) or the syncope episodes were reduced greater than or equal to 80% in 16 patients (84.2%). The mean NYHA functional class significantly improved from 2.2±0.7 at baseline to 1.7±0.6 during follow-up (P=0.002). The LVOTG and septal thickness showed a decreasing trend from baseline to follow-up (LVOTG: P=0.083, septal thickness: P=0.086). Conclusion: The authors' investigation provides evidence supporting the effectiveness of PESA in reducing syncope episodes in patients with HOCM.

2.
Asia Pac J Clin Oncol ; 20(2): 319-322, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36658669

RESUMEN

About 80% of hepatocellular carcinoma (HCC) patients are in advanced stages and ineligible for curative surgery. Palliative treatments just maintained limited survival, thus an effective downstaging therapy is badly needed. Here we report an initially unresectable patient who underwent radical hepatectomy after successful downstaging with selective internal radiation therapy (SIRT). A 34-year-old man was diagnosed with China Liver Cancer Staging (CNLC) IIIa HCC. Due to insufficient future liver remnant and vascular involvement, the patient was suggested to be unresectable. SIRT with yttrium-90 resin microspheres was given. At three months post-SIRT, a complete response was achieved. The tumor was downstaged to CNLC Ia stage. The patient underwent anatomical hepatectomy 5 months after SIRT. Histopathological examination of the resected specimen showed 4% viable tumor cells inside a necrotic mass. To our knowledge, this is the first case who underwent SIRT with yttrium-90 resin microspheres in China mainland. The success of the downstaging in this case renders a possible cure to be achieved in an initially unresectable patient. In addition, the nearly complete tumor necrosis in the resected specimen indicates a good prognosis post-surgery. This is the first case who underwent SIRT with yttrium-90 resin microspheres in China mainland. SIRT followed by anatomical hepatectomy is a potentially curative strategy for unresectable HCC, which deserves a confirmative trial in the future.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Masculino , Humanos , Adulto , Carcinoma Hepatocelular/radioterapia , Carcinoma Hepatocelular/cirugía , Carcinoma Hepatocelular/patología , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/cirugía , Neoplasias Hepáticas/patología , Hepatectomía , Microesferas , Radioisótopos de Itrio/uso terapéutico
3.
J Int Med Res ; 51(10): 3000605231208599, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37890144

RESUMEN

Haemophilia B is a rare inherited bleeding disorder in which patients have impaired coagulation. This study describes a patient with Haemophilia B and paroxysmal supraventricular tachycardia (PSVT) who underwent radio frequency catheter ablation (RFCA). The perioperative replacement therapy with coagulation factor IX (FIX) was agreed upon after an interdisciplinary consultation involving a team of specialists in haematology, cardiovascular medicine and cardiothoracic surgery. There were no obvious bleeding points or complications during the perioperative period following the treatment, nor recurrence of PSVT within a three-year follow-up period. In summary, RFCA can be performed safely in patients with haemophilia B on the premise of developing an individualized perioperative exogenous coagulation factor supplementation regimen based upon an adequate preoperative evaluation and clinical monitoring and management by an interdisciplinary team.


Asunto(s)
Ablación por Catéter , Hemofilia B , Taquicardia Paroxística , Taquicardia Supraventricular , Taquicardia Ventricular , Humanos , Taquicardia Supraventricular/cirugía , Hemofilia B/complicaciones , Hemofilia B/cirugía , Taquicardia Ventricular/cirugía
4.
BMC Cardiovasc Disord ; 22(1): 326, 2022 07 23.
Artículo en Inglés | MEDLINE | ID: mdl-35869446

RESUMEN

BACKGROUND: Percutaneous left atrial appendage (LAA) occlusion is effective for stroke prevention in patients with atrial fibrillation. LAA can have a complex anatomy, such as multiple lobes or a large orifice, which may render it unsuitable for occlusion using regular devices. We aimed to investigate the feasibility, safety, and short-term efficacy of the small-umbrella LAmbre device for morphologically complicated LAA. METHODS: We retrospectively enrolled 129 consecutive patients who underwent LAA occlusion using the LAmbre device; the small-umbrella LAmbre device was used in 30 of these patients. We analyzed patients' characteristics, procedural details, and outcomes. RESULTS: Twenty-two patients (73.3%) had multilobed (≥ 2) LAA. The umbrella of the occluder was anchored in the branch in 9 patients and in the common trunks of branches in 13 patients. The landing zone and orifice diameters were 19.0 ± 4.39 mm and 27.4 ± 3.95 mm, respectively. The sizes of the umbrella and occluder cover were 22.0 ± 3.42 mm and 34.3 ± 2.75 mm, respectively. At 3-month follow-up transesophageal echocardiography in 24 patients, no peri-device residual flow was reported. Device thrombosis was detected in one patient at 3 months and disappeared after 3 months of anticoagulation. Ischemic stroke occurred in one patient; no other adverse events were reported. CONCLUSIONS: Occlusion of morphologically complicated LAA using the small-umbrella LAmbre device was feasible, safe, and effective in patients with atrial fibrillation in this study. This occluder provides an alternative for patients who cannot be treated with regular-sized LAA occlusion devices.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Dispositivo Oclusor Septal , Accidente Cerebrovascular , Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Cateterismo Cardíaco/efectos adversos , Ecocardiografía Transesofágica/efectos adversos , Humanos , Estudios Retrospectivos , Dispositivo Oclusor Septal/efectos adversos , Accidente Cerebrovascular/complicaciones , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento
5.
Front Cardiovasc Med ; 9: 836392, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35571157

RESUMEN

Background: The 5-year outcomes and predictors of atrial fibrillation (AF) recurrence following cryoballoon (CB) ablation in Chinese population remain scarce. Our aim was to report 5-year outcomes and predictors of AF recurrence following a single CB ablation procedure in a Chinese population. Methods: From December 2013 to August 2016, we included 256 consecutive patients (mean age: 58 ± 10.9 years old; female: 41.0%) with paroxysmal or persistent AF successfully underwent first-generation CB ablation at Fuwai hospital in this prospective study. All patients were followed at least 5 years or when there was recurrent AF. Independent predictors of AF recurrence were determined by Cox proportional hazards regression analysis. Results: The 5-year success rate after pulmonary vein isolation (PVI) by a single procedure was 59.4%. The recurrence rate was the highest (14.5%) within the first year after the index procedure, and then stabilized. Patients with paroxysmal AF had a higher incidence of freedom from AF recurrence than patients with persistent AF (63.2% vs. 36.4%, log-rank P < 0.01). The overall incidence of complications related to CB ablation was 7.8%. Phrenic nerve injury (PNI) was the most common complication, with an incidence of 3.5%, and patients with PNI were recovered within the 1-year follow-up. Only persistent AF (HR 1.72, 95%CI 1.028-2.854, P < 0.05) was significantly and independently associated with an increased risk of AF recurrence after adjusting for other factors. Conclusion: Pulmonary vein isolation using CB ablation was safe and effective with an acceptable complication and 5-year success rate in a Chinese population with AF, and persistent AF was the independent predictor for 5-year AF recurrence after a single CB ablation procedure.

6.
Front Cardiovasc Med ; 8: 766571, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34869680

RESUMEN

Background: A variety of supraventricular arrhythmias (SVAs) may occur in patients with hypertrophic cardiomyopathy (HCM). The characteristics and long-term ablation outcomes of different types of SVAs in HCM have not been comprehensively investigated. Methods: We retrospectively enrolled 101 consecutive patients with HCM who were referred to the electrophysiology and arrhythmia service from May 2010 to October 2020. The clinical features and ablation outcomes were analyzed. Results: Seventy-eight patients had SVAs, which comprised 50 (64.1%) cases of atrial fibrillation (AF), 16 (20.5%) of atrial flutter (AFL), 15 (19.2%) of atrioventricular reentrant tachycardia (AVRT), 11 (14.1%) of atrial arrhythmia (AT), and 3 (3.8%) of atrioventricular nodal reentrant tachycardia (AVNRT). Thirty-four patients underwent catheter ablation and were followed up for a median (interquartile range) of 58.5 (82.9) months. There was no recurrence in patients with non-AF SVAs. In patients with AF, the 1- and 7-year AF-free survival rates were 87.5 and 49.5%, respectively. A receiver operator characteristic analysis showed that a greater left ventricular end-diastolic dimension (LVEDD) was associated with a higher recurrence of AF, with an optimum cutoff value of 47 mm (c-statistic = 0.91, p = 0.011, sensitivity = 1.00, specificity = 0.82). In Kaplan-Meier analysis, patients with a LVEDD ≥ 47 mm had worse AF-free survival than those with a LVEDD <47 mm (log-rank p = 0.014). Conclusions: In this unique population of HCM, AF was the most common SVA, followed in order by AFL, AVRT, AT, and AVNRT. The long-term catheter ablation outcome for non-AF SVAs in HCM is satisfactory. A greater LVEDD predicts AF recurrence after catheter ablation in patients with HCM.

7.
Front Cardiovasc Med ; 8: 705510, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34409078

RESUMEN

Background: Low-voltage zones (LVZs) were usually targeted for ablation in atrial fibrillation (AF). However, its relationship with AF initiation, perpetuation, and termination remains to be studied. This study aimed to explore such relationships. Methods: A total of 126 consecutive AF patients were enrolled, including 71 patients for AF induction protocol and 55 patients for AF termination protocol. Inducible and sustainable AF were defined as induced AF lasting over 30 and 300 s, respectively. Terminable AF was defined as those that could be terminated into sinus rhythm within 1 h after ibutilide administration. Voltage mapping was performed in sinus rhythm for all patients. LVZ was quantified as the percentage of the LVZ area (LVZ%) to the left atrium surface area. Results: The rates of inducible, sustainable, and terminable AF were 29.6, 18.3, and 38.2%, respectively. Inducible AF patients had no significant difference in overall LVZ% compared with uninducible AF patients (10.2 ± 11.8 vs. 8.5 ± 12.6, p = 0.606), while sustainable and interminable AF patients had larger overall LVZ% than unsustainable (16.2 ± 11.5 vs. 0.5 ± 0.7, p < 0.001) and terminable AF patients (44.6 ± 26.4 vs. 26.3 ± 22.3, p < 0.05), respectively. The segmental LVZ distribution pattern was diverse in the different stages of AF. Segmental LVZ% difference was initially observed in the anterior wall for patients with inducible AF, and the septum was further affected in those with sustainable AF, and the roof, posterior wall, and floor were finally affected in those with interminable AF. Conclusions: The associations between LVZ with AF initiation, perpetuation, and termination were different depending on its size and distribution.

8.
Herz ; 46(Suppl 1): 82-88, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32002565

RESUMEN

BACKGROUND: Cryoballoon ablation (CBA) is effective for patients with drug-refractory symptomatic atrial fibrillation (AF). For patients with a high risk of stroke (CHA2DS2-VASc score ≥2), life-long oral anticoagulation therapy should be continued even after successful catheter ablation. We investigated the safety and efficacy of concomitant use of a second-generation CBA catheter for pulmonary vein isolation (PVI) and a left atrial appendage closure (LAAC) device in patients with AF. METHODS: We enrolled 27 patients (64.7 ± 6.3 years, 74% male, 63% paroxysmal AF, 37% persistent AF, 4.8 ± 1.4 CHA2DS2-VASc score, and 3.6 ± 1.3 HAS-BLED score). In total, 85% of the patients had a prior stroke or TIA, and 30% of patients had a clinical history of bleeding. Patients received a CBA for PVI and underwent occlusion of the LAA with an LAAC device. The efficacy of CBA was defined as lack of arrhythmia recurrence (AF, atrial flutter, and/or atrial tachycardia lasting ≥30 s) after a 90-day blanking period. The success of LAAC was determined by the rate of stroke, TIA, and/or bleeding events. RESULTS: The mean procedural time for CBA and LAAC was 80 ± 16 min and 44 ± 12 min, respectively. Acute PVI by CBA was achieved in 100% of the procedures, and 96% of patients obtained acute LAAC device placement during the procedure. Upon complete release of the LAAC device, only 62% patients (16/26) had no detectable leakage during intraprocedural transesophageal echocardiography. Three patients experienced an acute complication: a pericardial effusion and two phrenic nerve palsy events. Mean follow-up was 18 months (range 9-23 months), and freedom from AF recurrence was 74% (20/27). CONCLUSION: The intraprocedural combination of CBA and LAAC is feasible in patients with non-valvular AF with a high risk of stroke, TIA, and/or bleeding. Larger long-term randomized studies are needed to judge the overall safety and efficacy of the combined procedure.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Procedimientos Quirúrgicos Cardíacos , Ablación por Catéter , Venas Pulmonares , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Femenino , Humanos , Masculino , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Resultado del Tratamiento
9.
J Geriatr Cardiol ; 18(12): 1019-1028, 2021 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-35136397

RESUMEN

BACKGROUND: Metabolic syndrome (MetS) has been reported as a risk factor of atrial fibrillation (AF) recurrence after radiofrequency catheter ablation. This study aimed to investigate the long-term influence of MetS on paroxysmal AF recurrence after a single cryoballoon ablation procedure, which was scarcely investigated yet in Chinese population. METHODS: In total, 137 paroxysmal AF patients who had successfully completed a single cryoballoon ablation procedure at Fuwai Hospital, Beijing, China from December 2013 to October 2015 were enrolled. Excepting for patients with AF recurrence, all patients were followed up for no less than five years. Independent predictors of AF recurrence were determined by Cox proportional hazards regression analysis. RESULTS: Among 137 paroxysmal AF patients, 91 patients (66.4%) had successfully achieved overall five-year follow-up after a single cryoballoon ablation procedure, and 44 patients (32.1%) had MetS. Patients with MetS had a significant lower incidence of freedom from AF recurrence than those without MetS (50.0% vs. 74.2%, log-rank P < 0.01) during the five-year follow-up. MetS (HR = 1.95, 95% CI: 1.069-3.551, P = 0.030) was an independent predictor of AF recurrence after adjusting for multiple factors. After the second year post cryoballoon ablation procedure, the recurrence rate of AF gradually increased in patients with MetS, in contrast, decreased recurrence rate of AF in patients without MetS. CONCLUSIONS: MetS is an independent predictor for five-year AF recurrence after a single cryoballoon ablation procedure in paroxysmal AF patients. Combination therapy of AF and MetS may improve the long-term outcomes of AF patients.

10.
J Arrhythm ; 36(6): 1016-1022, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33335618

RESUMEN

OBJECTIVES: This study aims to research the clinical features of atrial thrombi in patients with nonvalvular atrial fibrillation (AF). METHODS: This study included 191 patients of AF who had atrial thrombi. One hundred and twenty-eight of them were assigned into nonventricular cardiomyopathy group (non-VCM), and the remaining 63 into ventricular cardiomyopathy group (VCM). After atrial thrombi diagnosed, all patients had taken oral anticoagulant therapy. The resolution rates of thrombi within 12 months were compared between the two groups, as well as the locations of thrombi. RESULTS: Of all 191 patients, 161 had thrombi only detected in left atrial appendage (LAA), 20 in both left atrium (LA) and LAA, six in LA only, and four in right atrium only. More patients had thrombi out of LAA in the VCM group than in the non-VCM group (30.2% vs 8.6%, P < .001). After propensity score matching, the atrial thrombi were resolved faster in the non-VCM group than in the VCM group (mean time length: 22 ± 2 weeks vs 30 ± 3 weeks, P = .038), and the resolution rate within 12 months was higher in the non-VCM group than in the VCM group (88.7% vs 61.4%, Log-rank, P = .038). In Cox proportional hazards model, absence of ventricular cardiomyopathy was an independent predictor for the resolution of atrial thrombus (hazard ratio: 1.76; P = .035). CONCLUSIONS: The patients of atrial fibrillation with ventricular cardiomyopathies have higher incidence of thrombosis in the body of left atrium or right atrium. And the resolution rate was lower in these patients.

11.
J Cardiovasc Electrophysiol ; 31(12): 3223-3231, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33022772

RESUMEN

BACKGROUND: Supraventricular tachycardia (SVT) with coronary sinus (CS) ostial atresia (CSA) or coronary sinus stenosis (CSS) causes difficulty in electrophysiological procedures, but its characteristics are poorly understood. OBJECTIVE: Study the anatomical and clinical features of SVT patients with CSA/CSS. METHODS: Of 6128 patients with SVT undergoing electrophysiological procedures, consecutive patients with CSA/CSS were enrolled, and the baseline characteristics, imaging materials, intraoperative data, and follow-up outcomes were analyzed. RESULTS: Thirteen patients, seven with CSA and six with CSS, underwent the electrophysiological procedure. Decapolar catheters were placed into the proximal CS in three cases, while the rest were placed at the free wall of the right atrium. Fourteen arrhythmias were confirmed: four atrioventricular nodal reentrant tachycardias, five left-sided accessory pathways, three paroxysmal atrial fibrillations, and two atrial flutters (AFLs). In addition to three patients who underwent only an electrophysiological study, the acute ablation success rate was 100% in 10 cases, with no procedure-related complications. After a median follow-up period of 59.6 months, only one case of atypical AFL recurred. For those cases (seven CSA and two CSS) with a total of 10 anomalous types of CS drainage, three types were classified: from the CS to the persistent left superior vena cava (n = 3), from an unroofed CS (n = 3), and from the CS to the small cardiac vein (n = 3) or Thebesian vein (n = 1). CONCLUSION: Patients with CSA/CSS may develop different kinds of SVT. Electrophysiological procedures for such patients are feasible and effective. An individualized mapping strategy based on the three types of CS drainage will be helpful.


Asunto(s)
Ablación por Catéter , Seno Coronario , Taquicardia Supraventricular , Constricción Patológica , Seno Coronario/diagnóstico por imagen , Seno Coronario/cirugía , Electrocardiografía , Humanos , Prevalencia , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/epidemiología , Taquicardia Supraventricular/cirugía , Vena Cava Superior
12.
Int Heart J ; 61(5): 936-943, 2020 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-32879265

RESUMEN

On the basis of radiofrequency ablation of atrial fibrillation (AF), some studies suggested that early recurrences of atrial tachyarrhythmia (ERATs) were associated with late AF recurrence (LAFR), and some also suspected and challenged the current recommended 90 day blanking period. We aim to evaluate the impact of ERAT on long-term success and to determine the optimum blanking period after AF ablation using second-generation cryoballoon (sg-CB). From August 2016 to October 2018, 369 consecutive patients who successfully underwent initial AF ablation using sg-CB at the Fuwai Hospital were finally enrolled. All patients were followed up no less than 12 months. Receiver operating characteristic curve analysis was used to determine the optimum blanking period after AF ablation. There were 62 (16.8%) who experienced ERAT. After a median follow-up of 615 days, 74.5% were free of LAFR after the 90 day blanking period. Incidence of freedom from LAFR during the long-term follow-up was markedly lower in patients with ERAT than in those without ERAT (27.4% versus 84.0%; log-rank P < 0.001). Furthermore, only ERAT (HR 8.579; 95% CI 5.604-13.133; P < 0.001) was significantly associated with an increased risk of LAFR after adjusting for other factors. The optimum cut-off time point for the blanking period was 21.5 days (sensitivity: 71.1%, specificity: 94.1%). In conclusion, ERAT was an independent predictor of LAFR after AF ablation using sg-CB. Based on our findings, blanking period was advised to be shorten to 21.5 days or about 3 weeks instead of 90 days after CB ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía , Venas Pulmonares/cirugía , Recurrencia , Insuficiencia del Tratamiento , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Factores de Tiempo
13.
Cardiology ; 145(11): 710-719, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32841940

RESUMEN

BACKGROUND: There are several electrocardiographic algorithms to predict the origin of idiopathic outflow tract ventricular arrhythmias (OT-VAs). This study aimed to develop a more accurate and efficient stepwise electrocardiographic algorithm to discriminate left ventricular outflow tract (LVOT) from right ventricular outflow tract (RVOT) origin. METHODS AND RESULTS: We analyzed 12-lead electrocardiographic characteristics of 173 consecutive OT-VAs patients who underwent successful radiofrequency catheter ablation in the RVOT (n = 124) or LVOT (n = 49). Based on the areas under the receiver operating characteristic curves, the combination of transitional zone (TZ) index <0 and V2S/V3R index ≤1.5 exhibited 93.5% sensitivity, 85.9% specificity, and 87.3% accuracy. A further analysis was performed in the 71 OT-VAs with a V3-lead precordial transition. The sensitivity, specificity, and accuracy of the integration of V2S/V3R index ≤1.5 and R-wave deflection interval in lead V3 >80 ms were 91.7, 83.1, and 85.9%, respectively. In the prospective evaluation, the combination of TZ index and V2S/V3R index could identify the correct origin sites with 91.2% accuracy in the overall analysis, and the integration of V2S/V3R index ≤1.5 and R-wave deflection interval in lead V3 >80 ms exhibited 94% accuracy in V3-lead precordial transition. CONCLUSIONS: The combination of TZ index <0 and V2S/V3R index ≤1.5 is a simple and efficient stepwise electrocardiographic algorithm for predicting LVOT origin. For the OT-VAs with a V3-lead precordial transition, the integration of V2S/V3R index ≤1.5 and R-wave deflection interval in lead V3 >80 ms would be a better choice.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Algoritmos , Electrocardiografía , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/cirugía , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía
14.
Heart Rhythm ; 17(12): 2164-2171, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32653429

RESUMEN

BACKGROUND: The initial depolarization vector of outflow tract (OT) ventricular arrhythmia (VA) varies in different origins, which may help to predict OT-VA origin more accurately. OBJECTIVE: The purpose of this study was to develop a more accurate electrocardiographic (ECG) criterion for differentiating between left and right OT-VA origins. METHODS: We studied 275 patients with successful ablation in the right ventricular outflow tract (RVOT) (n = 207) or left ventricular outflow tract (LVOT) (n = 68) in the development cohort. Amplitude of the QRS complex within initial 40 ms (QRSi40) in precordial leads was measured. A novel criterion for identifying OT-VA origin was developed based on the development cohort. Predictive performance of novel criterion was further validated by comparing with previous ECG criteria (V2S/V3R index, V2 transition ratio, and transition zone index) in the validation cohort with 107 patients (RVOT 75; LVOT 32). RESULTS: QRSi40 of identical precordial leads were significantly greater in the LVOT group than the RVOT group (P <.05). In the development cohort, QRSi40 of V2 (V2QRSi40) exhibited the greatest area under the curve of 0.950, with cutoff ≥0.52 mV predicting LVOT origin (sensitivity 86.0%; specificity 94.6%). In the validation cohort, V2QRSi40 ≥0.52 mV outperformed previous criteria in predictive performance (accuracy 90.7%; sensitivity 84.4%; specificity 93.3%). This advantage of V2QRSi40 over previous criteria also held true for subgroups of transition zone index = 0 and V3 R/S transition. CONCLUSION: V2QRSi40 is a novel and accurate ECG criterion to predict OT-VA origin that outperforms previous criteria.


Asunto(s)
Electrocardiografía , Sistema de Conducción Cardíaco/fisiopatología , Ventrículos Cardíacos/fisiopatología , Complejos Prematuros Ventriculares/diagnóstico , Adulto , Ablación por Catéter/métodos , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Complejos Prematuros Ventriculares/fisiopatología , Complejos Prematuros Ventriculares/cirugía
15.
Am J Cardiol ; 126: 37-44, 2020 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-32336534

RESUMEN

Differentiation of outflow tract ventricular arrhythmias (OT-VAs) which originate from the posterior right ventricular outflow tract (RVOT), right coronary cusp (RCC) or near the His-bundle are still a challenge until now. This study was aimed to develop a stepwise electrocardiogram (ECG) algorithm to distinguish their locations. Seventy-five consecutive patients with VAs successfully ablated from the posterior RVOT (n = 57), near the His-bundle (n = 5) or RCC (n = 13) were enrolled in our study. Measurements with highest diagnostic performance were chosen to develop a diagnostic algorithm. Of all these ECG measurements, the R-wave amplitude in lead I and V2S/V3R index showed the best diagnostic performance to discriminate these anatomical sites. The optimal ECG discriminators were different combination of lead I and V2S/V3R index as follows: the posterior RVOT, Lead I R-wave amplitude <0.65 mV and V2S/V3R index>1.5 (96.2% sensitivity, 69.6% specificity); the near the His-bundle, lead I R-wave amplitude ≥0.65 mV and V2S/V3R index>1.5 (100% sensitivity, 70% specificity); RCC, lead I R-wave amplitude<0.65 mV and V2S/V3R index ≤1.5 (52.9% sensitivity, 93.1% specificity). Sequential algorithmic application of these criteria resulted in an overall accuracy of 83% in predicting site of OT-VA origin. A predominantly positive R-wave in lead I is seen in OT-VAs originated near the His-bundle. A stepwise ECG algorithm of combination with R-wave amplitude in lead I and V2S/V3R index could localize the origins of OT-VAs from the posterior RVOT, near the His-bundle and the RCC with a high accuracy.


Asunto(s)
Algoritmos , Fascículo Atrioventricular/fisiopatología , Electrocardiografía , Ventrículos Cardíacos/fisiopatología , Fibrilación Ventricular/fisiopatología , Adulto , Fascículo Atrioventricular/cirugía , Ablación por Catéter , Femenino , Ventrículos Cardíacos/cirugía , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad y Especificidad , Fibrilación Ventricular/cirugía
16.
Cardiology ; 145(5): 294-302, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32289773

RESUMEN

INTRODUCTION: Based on a small sample of patients with hypertension, a few studies have reported that the newly proposed SD + SV4 criterion for left ventricular hypertrophy (LVH) is better than traditional criteria. This study aimed to verify the diagnostic capability of the SD + SV4 criterion in a Chinese population with or without hypertension and to analyze the factors affecting the diagnostic accuracy of LVH. METHODS: A total of 248 patients with LVH or paroxysmal supraventricular tachycardia (PSVT) discharged from Fuwai Hospital from January 2010 to July 2018 were enrolled. Patients with LVH were diagnosed according to the left ventricular mass index calculated by the echocardiogram parameter as the gold standard in this study. The receiver operating curve (ROC) curve was performed to assess the diagnostic capability and cut-off values of the SD + SV4, RavL + SV3, and SV1 + RV5/RV6 criteria for LVH. Then, multivariate logistic regression analyses were performed to in-vestigate the factors affecting the accuracy of the SD + SV4 criterion. RESULTS: There were 170 (68.5%) patients with hypertension and 110 (44.4%) with PSVT. According to echocardiography, 107 (43.1%) patients were diagnosed with LVH. The area under the curve (AUC) of the SD + SV4 criterion was the largest compared with that of the RavL + SV3 and SV1 + RV5/RV6 criteria (AUC 0.765 vs. 0.718 vs. 0.713, respectively). The sex-specific SD + SV4 criterion had the highest consistency with the gold standard (r = 0.532 ± 0.054, p < 0.01), accompanied by the highest sensitivity (70.1%) and specificity (85.8%). The cut-off values of the sex-specific SD + SV4 criterion for LVH were ≥2.65 mV (male)/2.15 mV (female). The left ventricular ejection fraction (LVEF; OR 0.920, 95% CI 0.882-0.959, p < 0.001) was significantly different between the SD + SV4 criterion and the gold standard for LVH after adjusting for hypertension, PSVT history, body surface area, interventricular septum thickness, posterior wall thickness, and left ventricular internal diameter. CONCLUSION: The newly proposed SD + SV4 criterion provides improved sensitivity and accuracy for the diagnosis of LVH in the Chinese population. A decrease in LVEF is an independent factor affecting the diagnostic accuracy of LVH.


Asunto(s)
Hipertensión , Hipertrofia Ventricular Izquierda , Ecocardiografía , Electrocardiografía , Femenino , Humanos , Masculino , Volumen Sistólico , Función Ventricular Izquierda
17.
World J Clin Cases ; 8(2): 325-330, 2020 Jan 26.
Artículo en Inglés | MEDLINE | ID: mdl-32047781

RESUMEN

BACKGROUND: False tendon is a common intraventricular anatomical variation. It refers to a fibroid or fibromuscular structure that exists in the ventricle besides the normal connection of papillary muscle and mitral or tricuspid valve. A large number of clinical studies have suggested that there is a significant correlation between false tendons and premature ventricular complexes. However, few studies have verified this correlation during radiofrequency catheter ablation of premature ventricular complexes. CASE SUMMARY: A 45-year-old male was admitted to receive radiofrequency ablation for symptomatic premature ventricular complexes. A three-dimensional model of the left ventricle was established by intracardiac echocardiography using the CartoSoundTM mapping system. In addition to the left anterior papillary muscle, the posterior papillary muscle was mapped. False tendons were found at the base of the interventricular septum, and the other end was connected to the left ventricular free wall near the apex. An irrigated touch force catheter was advanced into the left ventricle via the retrograde approach. The earliest activation site was marked at the interventricular septum attachment of the false tendons and was successfully ablated. CONCLUSION: This case verified that false tendons can cause premature ventricular complexes and may be cured by radiofrequency ablation guided by intracardiac echocardiography with the CartoSoundTM system.

18.
J Electrocardiol ; 58: 46-50, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31715375

RESUMEN

OBJECTIVE: To investigate the characteristics of early recurrence (ER) of atrial tachyarrhythmia (ATA) defined as atrial fibrillation (AF), atrial tachycardia (AT), or atrial flutter (AFL) during a 90-day blanking period after pulmonary vein isolation by cryoablation (PVI-C) in patients with symptomatic drug refractory AF. Specifically, to determine if ER of ATA during the blanking period can predict late recurrence (LR) during a 12-month follow-up period. METHOD: A total of 51 patients with symptomatic AF (who received PVI-C) were monitored by trans-telephonic wireless electrocardiogram (TWECG) event recording during the landmark 90-day blanking period following an index ablation. Recurrent ATA was defined as any AF, AT, or AFL lasting longer than 30 s (as recorded by 12­lead ECG, 24-hour Holter monitor, or TWECG). For data analysis, patients were grouped into ER and non-ER cohorts during the 90-day blanking period and then cohorted into LR or non-LR groups during the 12-month follow-up. RESULTS: During the 90-day blanking period, 23 patients had an ER event of ATA while 28 patients had a non-ER experience. Also, during the 12-month follow-up period, 15 patients had a LR event while 36 patients were free from ATA (and placed in the non-LR cohort). Overall, the average success rate of cryoablation for AF was 70.6% at the 12-month follow-up period. Compared to the non-LR group, patients with LR showed a higher average percentage of diabetes mellitic (33.3% vs. 5.56%; P = 0.008) and had a larger mean left atrium diameter (41.2 ±â€¯4.3 mm vs. 36.5 ±â€¯4.2 mm; P = 0.0006). During evaluation of the 90-day blanking period, the LR group had more frequent attacks of ATA than compared to the non-LR group (27.7% vs. 2.4%; P < 0.001). Only two patients (7.1%) without ER in the blanking period (non-ER cohort) had relapsed into a LR of ATA during the one-year period. After multi-logistic regression analysis, ER could individually predict the risk of LR (RR = 58.8; P = 0.001). CONCLUSION: In our study, ER of ATA was a common phenomenon during the 90-day blanking period after PVI-C for AF, and it mostly occurred in the first month following the index ablation across all patients. ER is not equal to the LR of ATA; however, patients with an ER event had a higher risk of a LR during the 12-month follow-up period.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Electrocardiografía , Atrios Cardíacos , Humanos , Venas Pulmonares/cirugía , Recurrencia , Taquicardia , Resultado del Tratamiento
19.
Anatol J Cardiol ; 21(6): 314-321, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31142725

RESUMEN

OBJECTIVE: Little is known about left atrial appendage occlusion (LAAO) with WATCHMAN device in patients with atrial fibrillation (AF) in China. The aim of the present study was to evaluate the acute procedural performance and complication rate of LAAO procedures and patient selection in China. METHODS: A total of 658 consecutive Chinese patients who were referred to receive LAAO procedures with the WATCHMAN device between 2014 and 2017 were retrospectively included in the study. Patients were divided into four groups according to the year of procedures: Group 2014, Group 2015, Group 2016, and Group 2017. The procedural success, complication rates, and characteristics of Chinese patients, as well as the trends of patients' selection and management, were analyzed. RESULTS: The average age of the patients was 67.7+-9.2 years, the CHA2DS2-VASc score was 3.7+-1.6, and the HAS-BLED score was 2.5+-1.1. Both scores of patients in different years show obvious increasing trends (r=0.126, p=0.001 and r=0.145, p<0.001, respectively). Indications for LAAO included increased bleeding risk (45.6%), recent bleeding under oral anticoagulation (OAC) (9.0%), and non-compliance with OAC (51.4%). The implantation was successful in 643 (97.7%) patients, with a procedural complication rate of 0.6%. Approximately 80.1% of the patients received OAC after LAAO. CONCLUSION: In China, LAAO with WATCHMAN devices in patients with AF can be performed successfully with a low complication rate. Most of the target population had increased bleeding risk or non-compliance for OAC as indications and received OAC for antithrombotic therapy after the procedure.


Asunto(s)
Fibrilación Atrial/terapia , Atrios Cardíacos , Oclusión Terapéutica/instrumentación , Anciano , Fibrilación Atrial/diagnóstico por imagen , China , Ecocardiografía Transesofágica , Fibrinolíticos/uso terapéutico , Atrios Cardíacos/diagnóstico por imagen , Humanos , Persona de Mediana Edad , Prótesis e Implantes/clasificación , Estudios Retrospectivos
20.
Arq Bras Cardiol ; 110(5): 440-448, 2018 May.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-29898044

RESUMEN

BACKGROUND: The influence of pulmonary vein (PV) anatomy on cryo kinetics during cryoballoon (CB) ablation is unclear. OBJECTIVE: To investigate the relationship between PV anatomy and cryo kinetics during CB ablation for atrial fibrillation (AF). METHODS: Sixty consecutive patients were enrolled. PV anatomy, including ostial diameters (long, short and corrected), ratio between short and long diameters, ostium shape (round, oval, triangular, and narrow), and drainage pattern (typical, with common trunk, common antrum, ostial branch and supernumerary PV) were evaluated on multi-detector computed tomography (MDCT) images pre-procedure. Cryo kinetics parameters [balloon freeze time from 0 to -30ºC (BFT), balloon nadir temperature (BNT) and balloon warming time from -30 to +15ºC (BWT)] were recorded during procedure. All p values are two-sided, with values of p < 0.05 considered to be statistically significant. RESULTS: 606 times of freezing cycle were accomplished. Moderate negative correlation was documented between BNT and corrected PV diameter (r = -0.51, p < 0.001) when using 23-mm CBs, and mild negative correlation (r = - 0.32, p = 0.001) was found when using 28-mm CBs. Multivariate logistic regression analysis revealed that PV corrected ostial diameter (OR, 1.4; p = 0.004) predicted a BNT < -51ºC when using 23-mm CBs, while PV ostium oval shape (OR, 0.3; p = 0.033) and PV locations (left inferior PV: OR, 0.04; p = 0.005; right superior PV: OR, 4.3; p = 0.025) predicted BNT < -51ºC when using 28-mm CBs. CONCLUSIONS: MDCT can provide PV anatomy accurate evaluation prior CB ablation. PV anatomy is associated with cryo kinetics during ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Criocirugía/métodos , Venas Pulmonares/anatomía & histología , Anciano , Fibrilación Atrial/diagnóstico por imagen , Femenino , Humanos , Imagenología Tridimensional , Cinética , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/fisiopatología , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA