Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 97
Filtrar
2.
Clin Chem Lab Med ; 2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-39008654

RESUMEN

The healthcare systems are a prime target for cyber-attacks due to the sensitive nature of the information combined with the essential need for continuity of care. Medical laboratories are particularly vulnerable to cyber-attacks for a number of reasons, including the high level of information technology (IT), computerization and digitization. Based on reliable and widespread evidence that medical laboratories may be inadequately prepared for cyber-terrorism, a panel of experts of the Task Force Preparation of Labs for Emergencies (TF-PLE) of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) has recognized the need to provide some general guidance that could help medical laboratories to be less vulnerable and better prepared for the dramatic circumstance of a disruptive cyber-attack, issuing a number of consensus recommendations, which are summarized and described in this opinion paper.

4.
Int J Infect Dis ; 143: 107028, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38583825

RESUMEN

OBJECTIVES: An increase evasion of the SARS-CoV-2 virus toward vaccination strategies and natural immunity has been rapidly described notably because of the mutations in the spike receptor binding domain and the N-terminal domain. METHODS: Participants of the CRO-VAX HCP study who received the bivalent booster were followed up at 6 months. A pseudovirus-neutralization test was used to assess the neutralization potency of antibodies against D614G, Delta, BA.1, BA.5, XBB.1.5, BA.2.86, FL.1.5.1, and JN-1. RESULTS: The neutralizing capacity of antibodies against the Omicron variant or its subvariants was significantly reduced compared with D614G and Delta (P <0.0001). The lowest neutralizing response that was observed with JN-1 (geometric mean titers [GMTs] = 22.1) was also significantly lower than XBB.1.5 (GMT = 29.5, P <0.0001), BA.2.86 (GMT = 29.6, P <0.0001), and FL.1.5.1 (GMT = 25.2, P <0.0001). Participants who contracted a breakthrough infection because of XBB.1.5 had significantly higher neutralizing antibodies against all variants than uninfected participants, especially against the Omicron variant and its subvariants. CONCLUSIONS: Our results confirm that JN.1 is one of the most immune-evading variants to date and that the BA.2.86 subvariant did not show an increased immunity escape compared with XBB.1.5. The stronger response in breakthrough infection cases with the Omicron variant and its subvariants supports the need to use vaccine antigens that target circulating variants.


Asunto(s)
Anticuerpos Neutralizantes , Anticuerpos Antivirales , Vacuna BNT162 , COVID-19 , Inmunización Secundaria , SARS-CoV-2 , Humanos , Anticuerpos Neutralizantes/sangre , Anticuerpos Neutralizantes/inmunología , Anticuerpos Antivirales/sangre , Anticuerpos Antivirales/inmunología , COVID-19/prevención & control , COVID-19/inmunología , SARS-CoV-2/inmunología , Masculino , Femenino , Vacuna BNT162/inmunología , Vacuna BNT162/administración & dosificación , Adulto , Persona de Mediana Edad , Vacunas contra la COVID-19/inmunología , Vacunas contra la COVID-19/administración & dosificación , Glicoproteína de la Espiga del Coronavirus/inmunología , Pruebas de Neutralización
5.
Virology ; 595: 110082, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38636363

RESUMEN

Vaccines against SARS-CoV-2 were developed during the pandemic including the BNT162b2 and the mRNA-1273. We evaluated the levels of binding antibodies against the receptor binding domain and the levels of NAbs in individuals who developed a breakthrough infection after having received three doses of mRNA-1273. A total of 51 participants were included. The breakthrough group was compared to a 1:1 matched-control group. Among the 51 individuals, 18 (35%) developed a breakthrough infection. The GMT of NAbs against the BA.1 in the BK population was 278.1 (95%CI: 168.1-324.1). This titer was significantly lower compared to the matched-control group when considering all data (GMT = 477.4; 95%CI: 316.2-541.0; p = 0.0057). Results were similar for the BA.5 (GMT = 152.0 (95%CI: 76.9-172.9) for breakthrough and 262.0 (95%CI: 171.3-301.8) for control (p = 0.0043)). Our study found that individuals receiving the mRNA-1273 booster and who developed a breakthrough infection presented lower levels of binding antibodies and NAbs before the infection as compared to a matched-control group.


Asunto(s)
Vacuna nCoV-2019 mRNA-1273 , Anticuerpos Neutralizantes , Anticuerpos Antivirales , Vacunas contra la COVID-19 , COVID-19 , Personal de Salud , Inmunización Secundaria , SARS-CoV-2 , Humanos , Anticuerpos Neutralizantes/inmunología , Anticuerpos Neutralizantes/sangre , Vacuna nCoV-2019 mRNA-1273/inmunología , Vacuna nCoV-2019 mRNA-1273/administración & dosificación , COVID-19/inmunología , COVID-19/virología , COVID-19/prevención & control , Anticuerpos Antivirales/inmunología , Anticuerpos Antivirales/sangre , SARS-CoV-2/inmunología , SARS-CoV-2/genética , Masculino , Femenino , Adulto , Vacunas contra la COVID-19/inmunología , Vacunas contra la COVID-19/administración & dosificación , Persona de Mediana Edad , Vacuna BNT162/administración & dosificación , Vacuna BNT162/inmunología , Glicoproteína de la Espiga del Coronavirus/inmunología , Glicoproteína de la Espiga del Coronavirus/genética , Infección Irruptiva
7.
J Med Virol ; 96(1): e29365, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38185981

RESUMEN

Studies about the duration of the humoral and cellular response following the bivalent booster administration are still scarce. We aimed at assessing the humoral and cellular response in a cohort of healthcare workers that received this booster. Blood samples were collected before the administration of the bivalent booster from Pfizer-BioNTech and after 14, 28, 90, and 180 days. Neutralizing antibodies against either the D614G strain, the delta variant, the BA.5 variant, or the XBB.1.5 subvariant were measured. The cellular response was assessed by measurement of the release of interferon gamma from T cells in response to an in vitro SARS-CoV-2 stimulation. A substantial waning of neutralizing antibodies was observed after 6 months (23.1-fold decrease), especially considering the XBB.1.5 subvariant. The estimated T1/2 of neutralizing antibodies was 16.1 days (95% CI = 10.2-38.4 days). Although most participants still present a robust cellular response after 6 months (i.e., 95%), a significant decrease was also observed compared to the peak response (0.95 vs. 0.41 UI/L, p = 0.0083). A significant waning of the humoral and cellular response was observed after 6 months. These data can also help competent national authorities in their recommendation regarding the administration of an additional booster.


Asunto(s)
Vacuna BNT162 , Terapias Complementarias , Humanos , Inmunidad Celular , Anticuerpos Neutralizantes , Personal de Salud
8.
Antibiotics (Basel) ; 13(1)2024 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-38247626

RESUMEN

Molecular diagnostic testing is assumed to enable fast respiratory pathogen identification and contribute to improved pneumonia management. We set up a prospective clinical trial at a tertiary hospital intensive care unit including adult patients suspected of severe pneumonia from whom a lower respiratory tract sample could be obtained. During control periods (CPs), routine testing was performed, and during intervention periods (IPs), this testing was completed with the FilmArray Pneumonia Panel plus test (FA-PNEU) executed 24/7. The main objective was to measure the impact of FA-PNEU results in terms of reduced time to targeted antimicrobial treatment administration. Over a 10-month period, analysis was performed on 35 CP and 50 IP patients. The median time to targeted antimicrobial treatment administration was reduced to 4.3 h in IPs compared to 26.4 h in CPs, with 54% of IP patients having FA-PNEU results that led to a treatment modification, of which all but one were targeted. Modifications included 10 (37%) de-escalations, 7 (25.9%) escalations, 3 (11.1%) regimen switches, and 7 (25.9%) complete antimicrobial discontinuations. FA-PNEU results were available with a 42.3 h gain compared to routine identification. This prospective study confirmed retrospective data demonstrating the benefit of FA-PNEU testing in severe pneumonia management of critically ill patients through improved antimicrobial use.

11.
EJIFCC ; 34(3): 213-219, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37868082

RESUMEN

Background: The EFLM Task Force Preparation of Labs for Emergencies (TF-PLE) created a survey that has been distributed to its members for gathering information on the key hazards experienced by European medical laboratories during the COVID-19 pandemic. Methods: The survey was distributed to over 12,000 potential contacts (laboratory workers) via an EFLM newsletter, with responses collected between May 8 and June 8, 2023. Results: Two hundred replies were collected and examined from European laboratories. 69.7% and 78.1% of all responders said they were short on non-COVID and COVID reagents, respectively. Exactly half of respondents (50.0%) said that they could not complete all laboratory tests required for a specific period, but this figure climbed to 61.2% for COVID tests. Finally, 72.3% of respondents expressed exhaustion during the pandemic, and 61.2% reported increasing patient hostility. Conclusions: The COVID-19 pandemic had a significant impact on laboratory medicine in Europe. Cultural change, proactive planning, and even re-engineering in some parts of the laboratory industry may thus be necessary to prepare for future challenges.

12.
Clin Chim Acta ; 550: 117534, 2023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-37739023

RESUMEN

INTRODUCTION: Urinalysis is essential for diagnosing kidney-related medical conditions. Urine test strip analysis serves as an initial and efficient screening method for reflex testing with accurate quantitative methods. MATERIALS AND METHODS: Freshly voided urines (n = 206) were analysed using two urine test strip brands on UC-MAX (Menarini) and cobas u 601 (Roche Diagnostics) instruments. Ordinal scale categories and reflectance signals (if available) were both used for the comparison with reference quantitative methods for glucose, proteins and albumin (cobas 503). Samples were considered positive when glucose > 15 or ≥ 54 mg/dL, proteins ≥ 200 mg/L and albumin ≥ 10 mg/L. Optimized reflectance thresholds were calculated by ROC curve analysis. Analytical performance specifications (APS) for trueness of test strip were gathered from the EFLM guideline (FPD, FNG, FNC). RESULTS: Reflectance signals were significantly lower in urine samples considered positive by the reference method (p < 0.0001). Reflectance signals were also correlated with quantitative measurements, showing strong correlation (0.754 to 0.969). Only the use of optimized reflectance thresholds on cobas u 601 achieved at least the minimum EFLM APS (FPD < 20%, FNG < 50% and FNC < 10%). CONCLUSION: The use of reflectance signals from urine test strips enhanced accuracy for glucose, proteins, and albumin measurement and may contribute to improve diagnosis of diverse kidney-related conditions.


Asunto(s)
Tiras Reactivas , Urinálisis , Humanos , Urinálisis/métodos , Glucosa/análisis , Proteínas , Albúminas
16.
Clin Chem Lab Med ; 61(10): 1875-1885, 2023 09 26.
Artículo en Inglés | MEDLINE | ID: mdl-37078220

RESUMEN

OBJECTIVES: To assess the long-term humoral immunity induced by booster administration, as well as the ability of binding antibody and surrogate virus neutralization tests (sVNT) to predict neutralizing antibodies (NAbs) against the SARS-CoV-2 Omicron variant. METHODS: A total of 269 sera samples were analyzed from 64 healthcare workers who had received a homologous booster dose of BNT162b2. Neutralizing antibodies assessed by sVNT and anti-RBD IgG measured with the sCOVG assay (Siemens Healthineers®) were analyzed at five timepoints; before and up to 6 months following the booster. Antibody titers were correlated with neutralizing antibodies against the Omicron BA.1 variant obtained by pseudovirus neutralization test (pVNT) as a reference method. RESULTS: While Wild-type sVNT percentage of inhibition (POI) remained above 98.6% throughout the follow-up period after booster administration, anti-RBD IgG and NAbs assessed by Omicron BA.1 pVNT showed respectively a 3.4-fold and 13.3-fold decrease after 6 months compared to the peak reached at day 14. NAbs assessed by Omicron sVNT followed a steady decline until reaching a POI of 53.4%. Anti-RBD IgG and Omicron sVNT assays were strongly correlated (r=0.90) and performed similarly to predict the presence of neutralizing antibodies with Omicron pVNT (area under the ROC: 0.82 for both assays). In addition, new adapted cut-off values of anti-RBD IgG (>1,276 BAU/mL) and Omicron sVNT (POI>46.6%) were found to be better predictors of neutralizing activity. CONCLUSIONS: This study showed a significant drop in humoral immunity 6 months after booster administration. Anti-RBD IgG and Omicron sVNT assays were highly correlated and could predict neutralizing activity with moderate performance.


Asunto(s)
Anticuerpos Neutralizantes , COVID-19 , Humanos , SARS-CoV-2 , Pruebas de Neutralización , Vacuna BNT162 , Cinética , Inmunoglobulina G , Anticuerpos Antivirales
18.
J Clin Virol ; 161: 105419, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36905798

RESUMEN

BACKGROUND: A SARS-CoV-2+Flu A/B+RSV Combo Rapid test may be more relevant than Rapid Antigen Diagnostic (RAD) tests targeting only SARS-CoV-2 since we are facing a concurrent circulation of these viruses during the winter season. OBJECTIVES: To assess the clinical performance of a SARS-CoV-2+Flu A/B+RSV Combo test in comparison to a multiplex RT-qPCR. STUDY DESIGN: Residual nasopharyngeal swabs issued from 178 patients were included. All patients, adults and children, were symptomatic and presented at the emergency department with flu-like symptoms. Characterization of the infectious viral agent was done by RT-qPCR. The viral load was expressed as cycle threshold (Ct). Samples were then tested using the multiplex RAD test Fluorecare®à¸ SARS-CoV-2 & Influenza A/B & RSV Antigen Combo Test. Data analysis was carried out using descriptive statistics. RESULTS: The sensitivity of the test varies according to the virus, with the highest sensitivity observed for Influenza A (80.8.% [95%CI: 67.2 - 94.4]) and the lowest sensitivity observed for RSV (41.5% [95%CI: 26.2 - 56.8]). Higher sensitivities were observed for samples with high viral loads (Ct < 20) and decrease with low viral loads. The specificity for SARS-CoV-2, RSV and Influenza A and B was >95%. CONCLUSIONS: The Fluorecare® combo antigenic presents satisfying performance in real-life clinical setting for Influenza A and B in samples with high viral load. This could be useful to allow a rapid (self-)isolation as the transmissibility of these viruses increase with the viral load. According to our results, its use to rule-out SARS-CoV-2 and RSV infection is not sufficient.


Asunto(s)
COVID-19 , Gripe Humana , Infecciones por Virus Sincitial Respiratorio , Adulto , Niño , Humanos , Gripe Humana/diagnóstico , SARS-CoV-2 , COVID-19/diagnóstico , Infecciones por Virus Sincitial Respiratorio/diagnóstico , Pruebas Inmunológicas , Sensibilidad y Especificidad
19.
Clin Chem Lab Med ; 61(9): 1670-1675, 2023 08 28.
Artículo en Inglés | MEDLINE | ID: mdl-36999398

RESUMEN

OBJECTIVES: The BNT162b2 messenger RNA vaccine is highly effective in reducing COVID-19 infection, hospitalization and death. However, many subjects developed a breakthrough infection despite a full vaccination scheme. Since the waned efficacy of mRNA vaccines is correlated with the decrease of antibodies occurring over time, we aimed at evaluating whether lower levels of antibodies were associated with an increased risk of breakthrough infection in a cohort of breakthrough subjects that received three vaccine doses. METHODS: Total binding antibodies against the RBD of the S1 subunit (Roche Diagnostics, Machelen, Belgium) and neutralizing antibodies using the Omicron B.1.1.529 variant pseudovirus were measured. Based on individual kinetic curves, the antibody titer of each subject was interpolated just before the breakthrough infection and compared to a matched-control group that did not develop a breakthrough infection. RESULTS: Lower levels of total binding and neutralizing antibodies were observed compared to the control group (6.900 [95% CI; 5.101-9.470] vs. 11.395 BAU/mL [8.627-15.050] [p=0.0301] and 26.6 [18.0-39.3] vs. 59.5 dilution titer-1 [32.3-110] [p=0.0042], respectively). The difference between breakthrough and control subjects was mostly observed for neutralizing antibodies before three months after the homologous booster administration (46.5 [18.2-119] vs. 381 [285-509] [p=0.0156]). Considering the measurement of total binding antibodies before 3 months, there was no significant difference (p=0.4375). CONCLUSIONS: In conclusion, our results showed that subjects that developed a breakthrough infection had lower levels of neutralizing and total binding antibodies compared to controls. The difference was mostly noticeable considering neutralizing antibodies, especially for infections occurring before 3 months after the booster administration.


Asunto(s)
COVID-19 , Humanos , Infección Irruptiva , Vacuna BNT162 , Anticuerpos Neutralizantes , Atención a la Salud , Anticuerpos Antivirales
20.
Clin Chem Lab Med ; 61(8): 1420-1427, 2023 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-36785905

RESUMEN

OBJECTIVES: The aim of this study was to compare the results of five methods for the determination of total 25(OH)D. For that purpose, two mass spectrometry and three immunoassay methods were used. METHODS: A total of 124 serum samples were analyzed on five different methods (i.e., a reference LC-MS/MS, Cascadion, Lumipulse, Roche Elecsys II and Roche Elecsys III). Analytical performance against LC-MS/MS was evaluated and compared to the Milan models 1 (analytical performance based on the clinical outcome using thresholds of 12, 20 and 30 ng/mL) and 2 (analytical performance based on biological variation). Additionally, imprecision studies and accuracy using NIST SRM972a samples were carried out. RESULTS: Compared to the reference LC-MS/MS method, the Lumipulse and the Roche Elecsys III assays reached the optimal criterion for bias, while the Cascadion met the desirable one. The Roche Elecsys II was not able to reach the minimal criteria. The proportion of correctly classified patients was higher using the Cascadion (95.2%) compared to the three immunoassays. In addition to its better precision, the Cascadion was not impacted by a high concentration of 3-epi-25(OH)D3 compared to the three immunoassays. CONCLUSIONS: Compared to the LC-MS/MS reference method, the Cascadion presented the highest level of concordance at medical decision cut-offs for total 25(OH)D and reached the desirable specification for bias. Moreover, the presence of 3-epi-25(OH)D3 in enriched samples was only problematic in immunoassay methods, and especially considering Roche Elecsys methods. The release of performant fully automated mass spectrometry assays with high throughput might therefore facilitate the wide scale adoption of LC-MS/MS, even in non-specialized clinical laboratories.


Asunto(s)
Espectrometría de Masas en Tándem , Vitamina D , Humanos , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Inmunoensayo/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA