Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Comput Biol Med ; 168: 107817, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38064852

RESUMEN

Titanium patient-specific (CAD/CAM) plates are frequently used in mandibular reconstruction. However, titanium is a very stiff, non-degradable material which also induces artifacts in the imaging. Although magnesium has been proposed as a potential material alternative, the biomechanical conditions in the reconstructed mandible under magnesium CAD/CAM plate fixation are unknown. This study aimed to evaluate the primary fixation stability and potential of magnesium CAD/CAM miniplates. The biomechanical environment in a one segmental mandibular reconstruction with fibula free flap induced by a combination of a short posterior titanium CAD/CAM reconstruction plate and two anterior CAD/CAM miniplates of titanium and/or magnesium was evaluated, using computer modeling approaches. Output parameters were the strains in the healing regions and the stresses in the plates. Mechanical strains increased locally under magnesium fixation. Two plate-protective constellations for magnesium plates were identified: (1) pairing one magnesium miniplate with a parallel titanium miniplate and (2) pairing anterior magnesium miniplates with a posterior titanium reconstruction plate. Due to their degradability and reduced stiffness in comparison to titanium, magnesium plates could be beneficial for bone healing. Magnesium miniplates can be paired with titanium plates to ensure a non-occurrence of plate failure.


Asunto(s)
Colgajos Tisulares Libres , Reconstrucción Mandibular , Humanos , Colgajos Tisulares Libres/cirugía , Reconstrucción Mandibular/métodos , Magnesio , Titanio , Mandíbula/diagnóstico por imagen , Mandíbula/cirugía , Placas Óseas
2.
Br J Oral Maxillofac Surg ; 62(1): 45-50, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38008679

RESUMEN

Impaired bony healing following bilateral sagittal split osteotomy (BSSO) is a major unmet medical need for affected patients, and rare occurrences can hinder the identification of underlying risk factors. We hypothesised that osseous union following BSSO can be quantified using volumetric analysis, and we aimed to identify the risk factors for impaired bone healing. The percentage change in bony volume was measured in orthognathic patients following BSSO using two consecutive postoperative cone-beam computed tomography scans. Patients' characteristics and treatment parameters were documented, and correlation and regression analyses of these variables performed. Thirty-six patients (23 men and 13 women) with a mean (SD) age of 33.28 (11.86) years were included. The gap site (lingual versus buccal) (p < 0.01) had a significant impact on the change in volume. Age (p = 0.06) showed a trend towards significance. Initial width of the osteotomy gap, sex, and indication for surgery did not influence osseous healing. Increased age at surgery and the side of the buccal osteotomy are independent risk factors for impaired osseous healing following BSSO.


Asunto(s)
Mandíbula , Cirugía Ortognática , Masculino , Humanos , Femenino , Adulto , Mandíbula/diagnóstico por imagen , Mandíbula/cirugía , Osteotomía Sagital de Rama Mandibular/efectos adversos , Osteotomía Sagital de Rama Mandibular/métodos , Estudios Retrospectivos , Tomografía Computarizada de Haz Cónico/métodos
3.
Head Face Med ; 19(1): 43, 2023 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-37784107

RESUMEN

BACKGROUND: Mechanical and morphological factors have both been described to influence the rate of pseudarthrosis in mandibular reconstruction. By minimizing mechanical confounders, the present study aims to evaluate the impact of bone origin at the intersegmental gap on osseous union. METHODS: Patients were screened retrospectively for undergoing multi-segment fibula free flap reconstruction of the mandible including the anterior part of the mandible and osteosynthesis using patient-specific 3D-printed titanium reconstruction plates. Percentage changes in bone volume and width at the bone interface between the fibula/fibula and fibula/mandible at the anterior intersegmental gaps within the same patient were determined using cone-beam computed tomography (CBCT). Additionally, representative samples of the intersegmental zones were assessed histologically and using micro-computed tomography (µCT). RESULTS: The bone interface (p = 0.223) did not significantly impact the change in bone volume at the intersegmental gap. Radiotherapy (p < 0.001), time between CBCT scans (p = 0.006) and wound healing disorders (p = 0.005) were independent risk factors for osseous non-union. Preliminary analysis of the microstructure of the intersegmental bone did not indicate morphological differences between fibula-fibula and fibula-mandible intersegmental bones. CONCLUSIONS: The bone interface at the intersegmental gap in mandibular reconstruction did not influence long-term bone healing significantly. Mechanical and clinical properties seem to be more relevant for surgical success.


Asunto(s)
Colgajos Tisulares Libres , Neoplasias Mandibulares , Reconstrucción Mandibular , Seudoartrosis , Humanos , Reconstrucción Mandibular/métodos , Neoplasias Mandibulares/diagnóstico por imagen , Neoplasias Mandibulares/cirugía , Estudios Retrospectivos , Peroné/diagnóstico por imagen , Peroné/cirugía , Seudoartrosis/diagnóstico por imagen , Seudoartrosis/etiología , Seudoartrosis/cirugía , Microtomografía por Rayos X , Mandíbula/diagnóstico por imagen , Mandíbula/cirugía , Trasplante Óseo/métodos
4.
J Clin Med ; 12(20)2023 Oct 16.
Artículo en Inglés | MEDLINE | ID: mdl-37892681

RESUMEN

BACKGROUND: Isolated limb perfusion (ILP) for soft tissue sarcomas (STS) is usually performed with tumor necrosis factor alpha (TNF-α) and melphalan. ILP regularly leads to a total blood loss (BLt) of 1.5-2 L/patient. Blood inflow from the central blood circulation to the limb is influenced by unstable pressure gradients and pain reactions after the administration of melphalan. With perioperative regional anesthesia (RA), pain levels can be reduced, and the pressure gradient stabilized resulting in a reduced BLt. The aim of this study was to compare the BLt with and without RA in patients with ILP during circulation of drugs. METHODS: Patients were treated according to the following protocol: After the establishment of limb circulation, ILP was started with the administration of TNF-α. Half the dose of melphalan was given as a bolus after 30 min, and the remaining dose was continuously administered in the following 30 min. The extremity was washed out after 90 min. ILP with perioperative RA (supraclavicular plexus block/peridural catheter) was performed prospectively in 17 patients and compared to a matched retrospective control group of 17 patients without RA. BLt was documented and perioperative anesthesiological data were analyzed for response rates after the application of melphalan (RaM). RESULTS: BLt and RaM tended to be lower for the intervention group with RA if compared to the control group without RA in all analyses. The trend of lower BLt and RaM in ILP with RA was more pronounced for the upper extremity compared to the lower extremity. Results were not statistically significant. CONCLUSION: These findings indicate that the use of RA can help to stabilize hemodynamic anesthetic management and reduce the BLt in ILP, especially during perfusion of the upper extremities.

5.
Biomed Eng Online ; 22(1): 84, 2023 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-37641065

RESUMEN

BACKGROUND: The challenges in developing new bone replacement materials and procedures reside not solely in technological innovation and advancement, but also in a broader patient therapy acceptance. Therefore, there is a need to assess patients' perspectives on the materials and approaches in use as well as the ones being developed to better steer future progress in the field. METHODS: A self-initiating cross-sectional questionnaire aimed at people seeking treatment at the university hospital environment of Charité Berlin was formulated. The survey contained 15 close-ended questions directed toward the participant's epidemiological profile, willingness, acceptance, and agreement to receive different bone replacement materials, as well as, worries about the post-surgical consequences that can arise post bone replacement surgery. Descriptive and categorical analysis was performed to compare the observed number of subjects, their profile and each related response (Pearson's chi-square test or Fischer's test, p < 0.05). RESULTS: A total of 198 people engaged with the questionnaire, most of them Millennials. Overall patients trusted scientifically developed biomaterials designed for bone replacement, as demonstrated by their willingness to participate in a clinical trial, their acceptance of alloplastic materials, and the none/few worries about the presence of permanent implants. The data revealed the preferences of patients towards autologous sources of cells and blood to be used with a biomaterial. The data have also shown that both generation and education influenced willingness to participate in a clinical trial and acceptance of alloplastic materials, as well as, worries about the presence of permanent implants and agreement to receive a material with pooled blood and cells. CONCLUSION: Patients were open to the implantation of biomaterials for bone replacement, with a preference toward autologous sources of blood and/or tissue. Moreover, patients are concerned about strategies based on permanent implants, which indicates a need for resorbable materials. The knowledge gained in this study supports the development of new bone biomaterials.


Asunto(s)
Sustitutos de Huesos , Humanos , Estudios Transversales , Materiales Biocompatibles , Hospitales
6.
Front Physiol ; 14: 1152301, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37008011

RESUMEN

The mandible (lower jaw) bone is aesthetically responsible for shaping the lower face, physiologically in charge of the masticatory movements, and phonetically accountable for the articulation of different phonemes. Thus, pathologies that result in great damage to the mandible severely impact the lives of patients. Mandibular reconstruction techniques are mainly based on the use of flaps, most notably free vascularized fibula flaps. However, the mandible is a craniofacial bone with unique characteristics. Its morphogenesis, morphology, physiology, biomechanics, genetic profile, and osteoimmune environment are different from any other non-craniofacial bone. This fact is especially important to consider during mandibular reconstruction, as all these differences result in unique clinical traits of the mandible that can impact the results of jaw reconstructions. Furthermore, overall changes in the mandible and the flap post-reconstruction may be dissimilar, and the replacement process of the bone graft tissue during healing can take years, which in some cases can result in postsurgical complications. Therefore, the present review highlights the uniqueness of the jaw and how this factor can influence the outcome of its reconstruction while using an exemplary clinical case of pseudoarthrosis in a free vascularized fibula flap.

7.
Acta Biomater ; 157: 720-733, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36460289

RESUMEN

Bioabsorbable magnesium implants for orthopedic fixation of bone have recently become available for different fields of indication. While general questions of biocompatibility have been answered, tailoring suitable degradation kinetics for specific applications as well as long-term tissue integration remain the focus of current research. The aim of this study was the evaluation of the long-term degradation behavior and osseointegration of Mg-Ca-Zn (ZX00MEO) based magnesium implants with plasma-electrolytic oxidation (PEO) surface modification (ZX00MEO-PEO) in comparison to non-surface modified implants in vivo and in vitro. Besides a general evaluation of the biological performance of the alloy over a prolonged period, the main hypothesis was that PEO surface modification significantly reduces implant degradation rate and improves tissue interaction. In vitro, the microstructure and surface of the bioabsorbable screws were characterized by SEM/EDS, cytocompatibility and degradation testing facilitating hydrogen gas evolution, carried out following ISO 10993-5/-12 and ASTM F3268-18a/ASTM G1-03 (E1:2017). In vivo, screws were implanted in the frontal bone of Minipigs for 6, 12, and 18 months, following radiological and histomorphometric analysis. A slower and more uniform degradation and improved cytocompatibility could be shown for the ZX00MEO-PEO group in vitro. A significant reduction of degradation rate and enhanced bone formation around the ZX00MEO-PEO screws in vivo was confirmed. Proficient biocompatibility and tissue integration could generally be shown in vivo regardless of surface state. The tested magnesium alloy shows generally beneficial properties as an implant material, while PEO-surface modification further improves the bioabsorption behavior both in vitro and in vivo. STATEMENT OF SIGNIFICANCE: Devices from bioabsorbable Magnesium have recently been introduced to orthopedic applications. However, the vast degradation of Magnesium within the human body still gives limitations. While reliable in-vivo data on most promising surface treatments such as Plasma-electrolytic-Oxidation is generally scarce, long-time results in large animals are to this date completely missing. To overcome this lack of evidence, we studied a Magnesium-Calzium-Zinc-alloy with surface enhancement by PEO for the first time ever over a period of 18 months in a large animal model. In-vitro, surface-modified screws showed significantly improved cytocompatibility and reduction of degradation confirmed by hydrogen gas evolution testing, while in-vivo radiological and histological evaluation generally showed good biocompatibility and bioabsorption as well as significantly enhanced reduction of degradation and faster bone regeneration in the PEO-surface-modified group.


Asunto(s)
Magnesio , Prótesis e Implantes , Porcinos , Animales , Humanos , Porcinos Enanos , Magnesio/farmacología , Magnesio/química , Aleaciones/farmacología , Aleaciones/química , Hidrógeno , Ensayo de Materiales
8.
Front Bioeng Biotechnol ; 10: 1005022, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36466355

RESUMEN

Due to their advantages in applicability, patient-specific (CAD/CAM) reconstruction plates are increasingly used in fibula free flap mandible reconstruction. In addition, recently, CAD/CAM miniplates, with further advantages in postoperative management, have been introduced. However, biomechanical conditions induced by CAD/CAM systems remain partially unknown. This study aimed to evaluate the primary fixation stability of CAD/CAM fixators. For a patient-specific scenario, the biomechanical conditions induced in a one segmental fibula free flap stabilized using either a CAD/CAM reconstruction plate or CAD/CAM miniplates were determined using finite element analysis. The main output parameters were the strains between intersegmental bone surfaces and stresses in the fixation systems due to different biting scenarios. CAD/CAM miniplates resulted in higher mechanical strains in the mesial interosseous gap, whereas CAD/CAM reconstruction plate fixation resulted in higher strains in the distal interosseous gap. For all investigated fixation systems, stresses in the fixation systems were below the material yield stress and thus material failure would not be expected. While the use of CAD/CAM miniplates resulted in strain values considered adequate to promote bone healing in the mesial interosseous gap, in the distal interosseous gap CAD/CAM reconstruction plate fixation might result in more beneficial tissue straining. A mechanical failure of the fixation systems would not be expected.

9.
Biomater Adv ; 136: 212788, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35929320

RESUMEN

Bone defects of the craniofacial skeleton are often associated with aesthetic and functional impairment as well as loss of protection to intra- and extracranial structures. Solid titanium plates and individually adapted bone cements have been the materials of choice, but may lead to foreign-body reactions and insufficient osseointegration. In contrast, porous scaffolds are thought to exhibit osteoconductive properties to support bone ingrowth. Here, we analyse in critical size defects of the calvaria in sheep whether different bone replacement materials may overcome those remaining challenges. In a critical size defect model, bilateral 20 × 20 × 5-mm craniectomies were performed on either side of the sagittal sinus in 24 adult female blackheaded sheep. Bony defects were randomised to one of five different bone replacement materials (BRMs): titanium scaffold, biodegradable poly(d,l-lactic acid) calcium carbonate scaffold (PDLLA/CC), polyethylene 1 (0.71 mm mean pore size) or 2 (0.515 mm mean pore size) scaffolds and polymethyl methacrylate (PMMA)-based bone cement block. Empty controls (n = 3) served as references. To evaluate bone growth over time, three different fluorochromes were administered at different time points. At 3, 6 and 12 months after surgery, animals were sacrificed and the BRMs and surrounding bone analysed by micro-CT and histomorphometry. The empty control group verified that the calvaria defect in this study was a reliable critical size defect model. Bone formation in vivo was detectable in all BRMs after 12 months by micro-CT and histomorphometric analysis, except for the non-porous PMMA group. A maximum of bone formation was detected in the 12-months group for titanium and PDLLA/CC. Bone formation in PDLLA/CC starts to increase rapidly between 6 and 12 months, as the BRM resorbs over time. Contact between bone and BRM influenced bone formation inside the BRM. Empty controls exhibited bone formation solely at the periphery. Overall, porous BRMs offered bone integration to different extent over 12 months in the tested calvaria defect model. Titanium and PDLLA/CC scaffolds showed remarkable osseointegration properties by micro-CT and histomorphometric analysis. PDLLA/CC scaffolds degraded over time without major residues. Pore size influenced bone ingrowth in polyethylene, emphasising the importance of porous scaffold structure.


Asunto(s)
Sustitutos de Huesos , Animales , Cementos para Huesos/química , Sustitutos de Huesos/química , Femenino , Polietilenos , Polimetil Metacrilato/química , Ovinos , Cráneo/diagnóstico por imagen , Titanio
10.
Dentomaxillofac Radiol ; 51(7): 20220131, 2022 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-35762353

RESUMEN

OBJECTIVES: Pseudarthrosis after mandibular reconstruction leads to chronic overload of the osteosynthesis and impedes dental rehabilitation. This study evaluates the impact of gap site on osseous union in mandible reconstruction using a new volumetric analysis method with repeated cone-beam computed tomography (CBCT). METHODS: The degree of bone regeneration was evaluated in 16 patients after mandible reconstruction with a fibula free flap and patient-specific reconstruction plates. Percentual bone volume and width changes in intersegmental gaps were retrospectively analyzed using a baseline CBCT in comparison to a follow-up CBCT. Patients' characteristics, plate-related complications, and gap sites (anterior/posterior) were analyzed. Detailed assessments of both gap sites (buccal/lingual/superior/inferior) were additionally performed. RESULTS: Intersegmental gap width (p = 0.002) and site (p < 0.001) significantly influence bone volume change over two consecutive CBCTs. An initial larger gap width resulted in a lower bone volume change. In addition, anterior gaps showed significantly less bone volume changes. Initial gap width was larger at posterior segmental gaps (2.97 vs 1.65 mm, p = 0.017). CONCLUSIONS: A methodology framework has been developed that allows to quantify pseuarthrosis in reconstructed mandibles using CBCT imaging. The study identifies the anterior segmental gap as a further risk factor for pseudarthrosis in reconstructions with CAD/CAM reconstruction plates. Future research should evaluate whether this outcome is related to the biomechanics induced at this site.


Asunto(s)
Colgajos Tisulares Libres , Neoplasias Mandibulares , Reconstrucción Mandibular , Seudoartrosis , Trasplante Óseo/métodos , Humanos , Mandíbula/diagnóstico por imagen , Mandíbula/cirugía , Reconstrucción Mandibular/métodos , Seudoartrosis/diagnóstico por imagen , Seudoartrosis/etiología , Seudoartrosis/cirugía , Estudios Retrospectivos
11.
J Orthop Res ; 40(7): 1492-1504, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35451170

RESUMEN

Knee osteoarthritis, the most prevalent degenerative joint disorder worldwide, is driven by chronic low-grade inflammation and subsequent cartilage degradation. Clinical data on the role of the Hoffa or infrapatellar fat pad in knee osteoarthritis are, however, scarce. The infrapatellar fat pad is a richly innervated intracapsular, extrasynovial adipose tissue, and an abundant source of adipokines and proinflammatory and catabolic cytokines, which may contribute to chronic synovial inflammation, cartilage destruction, and subchondral bone remodeling during knee osteoarthritis. How the infrapatellar fat pad interacts with neighboring tissues is poorly understood. Here, we review available literature with regard to the infrapatellar fat pad's interactions with cartilage, synovium, bone, menisci, ligaments, and nervous tissue during the development and progression of knee osteoarthritis. Signaling cascades are described with a focus on immune cell populations, pro- and anti-inflammatory cytokines, adipokines, mesenchymal stromal cells, and molecules derived from conditioned media from the infrapatellar fat pad. Understanding the complex interplay between the infrapatellar fat pad and its neighboring articular tissues may help to better understand and treat the multifactorial pathogenesis of osteoarthritis.


Asunto(s)
Osteoartritis de la Rodilla , Adipoquinas/metabolismo , Tejido Adiposo/metabolismo , Citocinas/metabolismo , Humanos , Inflamación/metabolismo , Articulación de la Rodilla/patología , Osteoartritis de la Rodilla/patología
12.
Materials (Basel) ; 15(3)2022 Jan 27.
Artículo en Inglés | MEDLINE | ID: mdl-35160928

RESUMEN

Cranioplasty is a frequently performed procedure after craniectomy and includes several techniques with different materials. Due to high overall complication rates, alloplastic implants are removed in many cases. Lack of implant material osseointegration is often assumed as a reason for failure, but no study has proven this in cranioplasty. This study histologically evaluates the osteointegration of a computer-aided design and computer-aided manufacturing (CAD/CAM) titanium scaffold with an open mesh structure used for cranioplasty. A CAD/CAM titanium scaffold was removed due to late soft tissue complications 7.6 years after cranioplasty. The histological analyses involved the preparation of non-decalcified slices from the scaffold's inner and outer sides as well as a light-microscopic evaluation, including the quantification of the bone that had formed over the years. Within the scaffold pores, vital connective tissue with both blood vessels and nerves was found. Exclusive bone formation only occurred at the edges of the implant, covering 0.21% of the skin-facing outer surface area. The inner scaffold surface, facing towards the brain, did not show any mineralization at all. Although conventional alloplastic materials for cranioplasty reduce surgery time and provide good esthetic results while mechanically protecting the underlying structures, a lack of adequate stimuli could explain the limited bone formation found. CAD/CAM porous titanium scaffolds alone insufficiently osseointegrate in such large bone defects of the skull. Future research should investigate alternative routes that enable long-term osteointegration in order to reduce complication rates after cranioplasty. Opportunities could be found in mechano-biologically optimized scaffolds, material modifications, surface coatings, or other routes to sustain bone formation.

13.
Materials (Basel) ; 16(1)2022 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-36614440

RESUMEN

In fractures of the mandible, osteosynthesis with titanium plates is considered the gold standard. Titanium is an established and reliable material, its main disadvantages being metal artefacts and the need for removal in case of osteosynthesis complications. Magnesium, as a resorbable material with an elastic modulus close to cortical bone, offers a resorbable alternative osteosynthesis material, yet mechanical studies in mandible fracture fixation are still missing. The hypothesis of this study was that magnesium miniplates show no significant difference in the mechanical integrity provided for fracture fixation in mandible fractures under load-sharing indications. In a non-inferiority test, a continuous load was applied to a sheep mandible fracture model with osteosynthesis using either titanium miniplates of 1.0 mm thickness (Ti1.0), magnesium plates of 1.75 mm (Mg1.75), or magnesium plates of 1.5 mm thickness (Mg1.5). No significant difference (p > 0.05) was found in the peak force at failure, stiffness, or force at vertical displacement of 1.0 mm between Mg1.75, Mg1.5, and Ti1.0. This study shows the non-inferiority of WE43 magnesium miniplates compared to the clinical gold standard titanium miniplates.

14.
Mater Sci Eng C Mater Biol Appl ; 129: 112380, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34579899

RESUMEN

Magnesium is a highly promising candidate with respect to its future use as a material for resorbable implants. When magnesium degrades, hydrogen gas is released. High doses of gas emergence are reported to impair osseointegration and may therefore lead to fixation failure. The successful delay and reduction of the degradation rate by applying plasma electrolytic oxidation (PEO) as a post processing surface modification method for magnesium alloy has recently been demonstrated. The aim of this study was thus to compare the degradation behavior of a WE43-based plate system with and without respective PEO surface modification and to further investigate osseointegration, as well as the resulting effects on the surrounding bony tissue of both variants in a miniature pig model. WE43 magnesium screws and plates without (WE43) and with PEO surface modification (WE43-PEO) were implanted in long bones of Göttingen Miniature Pigs. At six and twelve months after surgery, micro-CT and histomorphometric analysis was performed. Residual screw volume (SV/TV; WE43: 28.8 ± 21.1%; WE43-PEO: 62.9 ± 31.0%; p = 0.027) and bone implant contact area (BIC; WE43: 18.1 ± 21.7%; WE43-PEO: 51.6 ± 27.7%; p = 0.015) were increased after six months among the PEO-modified implants. Also, surrounding bone density within the cortical bone was not affected by surface modification (BVTV; WE43: 76.7 ± 13.1%; WE43-PEO: 73.1 ± 16.2%; p = 0.732). Intramedullar (BV/TV; WE43: 33.2 ± 16.7%; WE43-PEO 18.4 ± 9.0%; p = 0.047) and subperiosteal (bone area; WE43: 2.6 ± 3.4 mm2; WE43-PEO: 6,9 ± 5.2 mm2; p = 0.049) new bone formation was found for both, surface-modified and non-surface-modified groups. After twelve months, no significant differences of SV/TV and BV/TV were found between the two groups. PEO surface modification of WE43 plate systems improved osseointegration and significantly reduced the degradation rate within the first six months in vivo. Osteoconductive and osteogenic stimulation by WE43 magnesium implants led to overall increased bone growth, when prior PEO surface modification was conducted.


Asunto(s)
Magnesio , Oseointegración , Aleaciones , Animales , Tornillos Óseos , Porcinos , Porcinos Enanos
15.
Front Bioeng Biotechnol ; 9: 672176, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34026745

RESUMEN

Mandibular fracture fixation and reconstruction are usually performed using titanium plates and screws, however, there is a need to improve current fixation techniques. Animal models represent an important step for the testing of new designs and materials. However, the validity of those preclinical models in terms of implant biomechanics remains largely unknown. In this study, we investigate the biomechanics of the sheep mandible as a preclinical model for testing the mechanical strength of fixation devices and the biomechanical environment induced on mandibular fractures. We aimed to assess the comparability of the biomechanical conditions in the sheep mandible as a preclinical model for human applications of fracture fixation devices and empower analyses of the effect of such defined mechanical conditions on bone healing outcome. We developed 3D finite element models of the human and sheep mandibles simulating physiological muscular loads and three different clenching tasks (intercuspal, incisal, and unilateral). Furthermore, we simulated fractures in the human mandibular body, sheep mandibular body, and sheep mandibular diastema fixated with clinically used titanium miniplates and screws. We compared, at the power stroke of mastication, the biomechanical environment (1) in the healthy mandibular body and (2) at the fracture sites, and (3) the mechanical solicitation of the implants as well as the mechanical conditions for bone healing in such cases. In the healthy mandibles, the sheep mandibular body showed lower mechanical strains compared to the human mandibular body. In the fractured mandibles, strains within a fracture gap in sheep were generally not comparable to humans, while similar or lower mechanical solicitation of the fixation devices was found between the human mandibular body fracture and the sheep mandibular diastema fracture scenarios. We, therefore, conclude that the mechanical environments of mandibular fractures in humans and sheep differ and our analyses suggest that the sheep mandibular bone should be carefully re-considered as a model system to study the effect of fixation devices on the healing outcome. In our analyses, the sheep mandibular diastema showed similar mechanical conditions for fracture fixation devices to those in humans.

16.
Acta Biomater ; 133: 46-57, 2021 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-33974949

RESUMEN

To present knowledge, macrophages are found in all tissues of the human body. They are a cell population with high plasticity which come with a multitude of functions which appear to be adapted to the respective tissue niche and micro-environment in which they reside. Bone harbors multiple macrophage subpopulations, with the osteoclasts as classical representative of a bone resorbing cells and osteomacs as a bone tissue resident macrophage first described by the expression of F4/80. Both subtypes are found throughout all phases in bone healing. In vivo data on bone regeneration have demonstrated their essential role in initiating the healing cascade (inflammatory phase) but also of the later phases of healing (e.g. endochondral and intramembranous bone formation). To participate in such diverse processes macrophages have to be highly plastic in their functionality. Thus, the widely used M1/M2 paradigm to distinguish macrophage subpopulations may not mirror the comprehensive role of the dynamics of macrophage plasticity. From a clinical perspective it is especially relevant to distinguish what drives macrophages in impaired healing scenarios, implant loosening or infections, where their specific role of a misbalanced inflammatory setting is so far only partially known. With this review we aim at illustrating current knowledge and gaps of knowledge on macrophage plasticity and function during the cascades of regeneration and reconstitution of bone tissue. We propose aspects of the known biological mechanisms of macrophages and their specific subsets that might serve as targets to control their function in impaired healing and eventually support a scar-free regeneration. STATEMENT OF SIGNIFICANCE: Macrophages are essential for successful regeneration. In scar-free healing such as in bone, a complete failure of healing was shown if macrophages were depleted; the M1/M2 switch appears to be key to the progression from pro-inflammation to regeneration. However, experimental data illustrate that the classical M1/M2 paradigm does not completely mirror the complexity of observed macrophage functions during bone healing and thus demands a broader perspective. Within this review we discuss the high degree of plasticity of macrophages and the relevant contribution of the different and more specific M2 subtypes (M2a-M2f) during (bone) regeneration. It summarizes the versatile roles of macrophages in skeletal regeneration and thereby highlights potential target points for immunomodulatory approaches to enable or even foster bone repair.


Asunto(s)
Regeneración Ósea , Macrófagos , Huesos , Humanos , Osteogénesis , Cicatrización de Heridas
17.
Front Bioeng Biotechnol ; 9: 803103, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-35223813

RESUMEN

Titanium fixation devices are the gold standard for the treatment of mandibular fractures; however, they present serious limitations, such as non-degradability and generation of imaging artifacts. As an alternative, biodegradable magnesium alloys have lately drawn attention due to their biodegradability and biocompatibility. In addition, magnesium alloys offer a relatively high modulus of elasticity in comparison to biodegradable polymers, being a potential option to substitute titanium in highly loaded anatomical areas, such as the mandible. This study aimed to evaluate the biomechanical competence of magnesium alloy WE43 plates for mandibular fracture fixation in comparison to the clinical standard or even softer polymer solutions. A 3D finite element model of the human mandible was developed, and four different fracture scenarios were simulated, together with physiological post-operative loading and boundary conditions. In a systematic comparison, the material properties of titanium alloy Ti-6Al-4V, magnesium alloy WE43, and polylactic acid (PLA) were assigned to the fixation devices, and two different plate thicknesses were tested. No failure was predicted in the fixation devices for any of the tested materials. Moreover, the magnesium and titanium fixation devices induced a similar amount of strain within the healing regions. On the other hand, the PLA devices led to higher mechanical strains within the healing region. Plate thickness only slightly influenced the primary fixation stability. Therefore, magnesium alloy WE43 fixation devices seem to provide a suitable biomechanical environment to support mandibular fracture healing in the early stages of bone healing. Magnesium WE43 showed a biomechanical performance similar to clinically used titanium devices with the added advantages of biodegradability and radiopacity, and at the same time it showed a remarkably higher primary stability compared to PLA fixation devices, which appear to be too unstable, especially in the posterior and more loaded mandibular fracture cases.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA