Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
J Dent Educ ; 2024 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-38764166

RESUMEN

OBJECTIVES: Conceptualizing the next patient interaction is logical, essential, and largely done intuitively with limited literature. The first objective is to elicit student thought experiences to four questions. The secondary objective is to classify responses for respective questions and to review faculty assessments. METHODS: Forty-two students completed the exercise in the first clinical prosthodontics experience after a simulation course, in the fall of 2023. Four open-ended questions were 1) differentiation from the ideal, 2) desired outcome(s), 3) self-capabilities, and 4) consequences/prognosis. Nine different faculty assessed the exercise. RESULTS: 100% of students responded to all four questions and 83% of responses were judged by faculty to grasp the concept in the question. The authors categorized responses into natural categories for each question. Authors separately assigned responses to categories. The agreement rate was 90%. Little to no overlap in responses was observed among the four questions. The sequence of questions led students to thought experiences from empathy in Question #1, to compassion in Question #2, and to self-reflection in Question #3 to social projection in Question #4. CONCLUSIONS: The main objective was met by engaging students in thought-provoking responses to questions the experienced clinician asks of every patient encounter. The exercise elicited different kinds of thought experiences on four topics. The format was succinct with acceptance by students and faculty. The project has progressed from a concept some years ago to a recent pilot to full implementation with the current project. The next steps will be refinement and follow-up in some years. The project follows an emulation model for critical thinking.

2.
Materials (Basel) ; 17(9)2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38730851

RESUMEN

AIM: This in vitro study aimed to compare the light-transmission properties of two chairside CAD/CAM lithium disilicate (LD) ceramics (a novel fully crystallized and a traditional pre-crystallized) across varying thicknesses. MATERIALS AND METHODS: One hundred flat specimens were obtained from precrystallized (e.max CAD, Ivoclar Vivadent, Schaan, Liechtenstein) and fully crystallized (LiSi GC Block; GC, Tokyo, Japan) LD at five different thicknesses (0.5, 0.75, 1.0, 1.50 and 2.0 mm). All specimens were polished with a polishing system for lithium disilicate restorations following recommendations from the manufacturer. Light transmission was evaluated with a radiometer. The statistical analysis between e.max CAD and LiSi GC Block was performed using a Mann-Whitney test for each thickness at a significance level of 0.05 (p < 0.05), followed by a Kruskal-Wallis test to compare the light transmission between the thicknesses of e.max CAD and LiSi GC Block. RESULTS: Light transmittance was significantly affected by ceramic thickness. The 0.5 mm thick specimens exhibited the highest transmittance values compared to all other groups, while a light transmittance of 0.00 was observed in the 2.0 mm thick specimens for both e.max CAD and LiSi GC Block. In the comparison between e.max CAD and LiSi GC Block according to thickness, there was a statistically significant difference exclusively between groups with a thickness of 1.50 mm (p = 0.002). CONCLUSIONS: Light transmission for pre- and fully crystallized CAD/CAM lithium disilicate ceramics only showed a statistical difference at the thickness of 1.50 mm (p = 0.002). E.max CAD demonstrated acceptable light transmission up to a thickness of 1.5 mm. CLINICAL SIGNIFICANCE: A thickness of 2 mm for chairside CAD/CAM lithium disilicate ceramics, whether pre-crystallized or fully crystallized, necessitates the use of dual-cure resin luting cement due to reduced light transmission.

3.
Case Rep Dent ; 2024: 5572481, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38560367

RESUMEN

This case report details the esthetic rehabilitation of a 32-year-old male patient suffering from sleep bruxism, primarily manifesting as a fracture and significant loss of tooth structure in the anterior maxillary central incisors. To address these concerns, the patient underwent a restorative treatment involving the application of semidirect resin composite veneers on the maxillary incisors and direct resin composite restoration on the incisal regions of the maxillary canines. This approach not only restored the functional integrity of the teeth but also significantly enhanced the patient's esthetic appearance.

4.
J Prosthodont ; 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38666691

RESUMEN

PURPOSE: This systematic review aims to compare clinical outcomes of digital dentures with conventional dentures. MATERIALS AND METHODS: This study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines and was registered in Prospero. The formulated population, intervention, comparison, outcome (PICO) question was "What is the clinical outcome of digital versus conventional complete dentures (CDs) in edentulous patients?". The search strategy used three main electronic databases and an additional manual search was completed in August 2023 by following an established search strategy. Initial inclusion was based on titles and abstracts, followed by a detailed review of selected studies, and clinical studies that evaluated the clinical outcome of digital (milled or 3D-printed) versus conventional CDs were included. A qualitative analysis for clinical studies was used to assess the risk of bias. The certainty of the evidence was assessed according to the grading of recommendations, assessment, development, and evaluations (GRADE) system. In addition, a single-arm meta-analysis was performed to evaluate the retention between digital versus conventional CDs. RESULTS: The initial search yielded a total of 947 articles, out of which 19 were selected for a comprehensive review, and six met the eligibility criteria to be included in this systematic review. The computer-aided design and computer-aided manufacturing (CAD-CAM) CDs showed increased retention, no relevant differences in oral health-related quality of life (OHRQoL), and shorter working time compared to conventional dentures. Two studies were eligible for meta-analysis; retention was significantly better among CAD-CAM fabricated dentures (standardized mean difference [SMD] 0.501) than conventional dentures. The heterogeneity between studies was high (95% CI: 0.049-0.952). CONCLUSIONS: Clinically, both the milled and the 3D-printed CD fared better than conventional dentures in terms of retention, reduction in the number of appointments, improved patient comfort, and improved predictable maintenance of the denture. Patients' perceptions and satisfaction were independent of the digital and conventional fabricated dentures.

5.
Dent J (Basel) ; 12(3)2024 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-38534286

RESUMEN

BACKGROUND: We compared the repeatability of the shade determination of resin composite restorations and acrylic teeth in light and darker shades at baseline and after an aging process through two digital tooth color-matching methods: using a Trios 3Shape intraoral scanner and using a Vita Easyshade Compact spectrophotometer. MATERIAL AND METHODS: Forty upper central incisor acrylic teeth in the shade A1 (n = 10) and A3 (n = 10) were randomly assigned to be restored with Filtek Bulk Fill in the shade A1 (n = 10) or A3 (n = 10). Subsequently, 20 Class V cavities were prepared in a standardized manner (mesio-distal = 3.0 mm, cervical-occlusal = 2.0 mm, depth = 1.5 mm). Cavities were restored using an universal adhesive system and resin composite in two increments and were light-cured. The shade difference between the resin composite Class V restorations in acrylic teeth of the A1 and A3 shades was evaluated at baseline and after aging. Aging was simulated using ultraviolet light for 120 h. An Easyshade device and an intraoral scanner were used under D65 illumination. Measurements were taken five times, on top of the restoration and on the acrylic teeth, in a randomized manner. RESULTS: Data analysis was on the calculation of the arithmetic mean for the percentage of repeatability conducted by the Trios scanner and the Easyshade device. There was no statistically significant comparison between the shade measurement devices (p > 0.05). At baseline, the repeatability for both the Trios intraoral scanner and the Vita Easyshade Compact device for artificial teeth in the shades A1 and A3 was 100%. After aging, the trueness recorded by the intraoral scanner and the Easyshade device for artificial teeth in the shade A1 was 80%. For Class V restoration with shade A1, the intraoral scanner recorded 80% trueness and the Easyshade device recorded 60% trueness at baseline. For shade A3, the intraoral scanner recorded 60% trueness and the Easyshade device recorded 60% trueness. CONCLUSIONS: The intraoral scanner and Easyshade device are reliable for baseline shade selection, but their accuracy decreases after aging, particularly for darker shades.

6.
Medicina (Kaunas) ; 60(2)2024 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-38399547

RESUMEN

With the life expectancy increasing, there is a growing need for prosthetic dental treatments to restore the oral health, function, and quality of life of edentulous patients. Presently, only a few articles are available describing the oral rehabilitation of patients with severely resorbed ridges with milled complete dentures. This clinical case report provides a straightforward protocol consisting of a combination of analog and digital techniques for the rehabilitation of edentulous patients with severely resorbed ridges with milled fixed and removable complete dentures. This technique permits the minimization of the number of appointments, improves patient comfort, allows for the digital archiving of important clinical data, and permits the manufacture of prostheses with improved mechanical properties. These favorable outcomes were achieved by using the patient's existing PMMA complete denture as a custom tray for a final impression with light-bodied Polyvinylsiloxane. Subsequently, the resulting models were digitized, and a digital complete denture was designed and manufactured in an expedited manner using CAD-CAM techniques. Therefore, this case report highlights the potential of CAD/CAM technology to predictably restabilize oral functions and improve patients' quality of life.


Asunto(s)
Boca Edéntula , Calidad de Vida , Humanos , Dentadura Completa , Boca Edéntula/rehabilitación , Diseño Asistido por Computadora
7.
J Prosthodont ; 33(4): 313-323, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37794763

RESUMEN

PURPOSE: This systematic review was conducted to evaluate the prevalence of interproximal contact loss (ICL) between implant restorations and adjacent teeth in relation to age, gender, follow-up time, and arch location. METHODS: This study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines and was registered in the Open Science Framework (OSF). The formulated population, intervention, comparison, outcome (PICO) question was "What is the prevalence of the ICL between implant restoration and adjacent teeth?" The search strategy used four main electronic databases and an additional manual search was performed until February 2023. Clinical studies that evaluated the prevalence of interproximal open contact between implant restorations and adjacent teeth were included. A qualitative analysis for clinical studies was used to assess the risk of bias. In addition, a single-arm meta-analysis of proportion was performed to evaluate the percentage of mesial versus distal open contact and total ICL between implant restoration and adjacent teeth. RESULTS: Fifteen studies published between 2014 and 2023 met the eligibility criteria. Seven studies presented ICL rates higher than 20%. All studies evaluated ICL in posterior regions (molar, premolar area). Five studies had an ICL rate lower than 50% and three studies had an ICL rate higher than 50%. One study assessed the interproximal contact at three months post-restoration insertion, four studies assessed the interproximal contact at 1-year follow-up and nine studies evaluated the interproximal contact over 2 years of follow-up. Mesial and distal ICL rates were 44.2% (95% CI: 30.6% to 58.6%) and 27.5% (95% CI: 10.5% to 55.0%), respectively. The heterogeneity between studies was high (I2 (95% CI) = 87.8% (75.9% to 93.8%). CONCLUSION: Based on the results of the included studies, the prevalence of ICL was high, occurring more frequently at the mesial contact. There were no significant differences in relation to age, gender, and arch location.


Asunto(s)
Implantes Dentales , Boca Edéntula , Diente , Humanos , Implantes Dentales/efectos adversos , Implantación Dental Endoósea , Diente Molar
8.
Eur J Dent ; 17(4): 964-973, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36716787

RESUMEN

This article compares the accuracy of intraoral scanners (IOSs) used in the digital impression of full arches to fabricate implant-supported complete prostheses. This study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines and was registered in the Open Science Framework (DOI 10.17605/OSF.IO/CPM9K). Six electronic databases, gray literature databases, and a manual search were performed in April 2022. Studies that evaluated the accuracy of intraoral scan impressions compared with conventional impressions in full-arch impressions were included for complete implant-supported prostheses. In addition, an adapted checklist for reporting in vitro studies was used to assess the risk of bias. Meta-analysis was conducted using a random-effects Hunter- Schmidt model. Nine studies were included in the analysis. IOS impressions present higher accuracy (137.86 µm) than conventional impressions (182.51 µm) (p<0.001). The heterogeneity of the study's methodology was I2»18.34. However, impression accuracy varies significantly with scan body type, IOS type, scanning strategy, and modification technique. For most IOS systems, the acceptable clinical threshold of linear accuracy of 200 µm can be achieved, except for the True Definition Scanner in one of the studies. Based on the results of the included studies, digital impressions using IOS present similar or better linear accuracy than conventional impression techniques.

9.
J Dent ; 127: 104346, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36414990

RESUMEN

OBJECTIVES: To compare the degree of satisfaction (SD) and the impact on oral health-related quality of life (OHRQoL) of edentulous patients treated with conventional complete dentures (CCDs) and mandibular overdentures (IODs) with a short anteroposterior spread (S-APS) or a large antero-posterior spread (L-APS). MATERIALS AND METHODS: Edentulous patients were treated with CCDs and subsequently randomly allocated to receive a bar clip mandibular overdenture retained by 2 interforaminal implants (Control) or 4 (Test: 2 additional implants distal to the mental foramen). The Oral Health Impact Profile Edent questionnaire (OHIP-20E) and the Visual Analogue Scale (VAS) were applied at a mean follow-up of 38.5 months to assess the impact on OHRQoL and DS, respectively. Comparisons between the type of prosthesis and the extension of the AP spread were made with Student's t test for paired samples and for independent samples, respectively, at a significance level of 5%. RESULTS: The IODs had significantly lower OHRQoL values ​​in the dimensions "functional limitation" (p=0.03), "physical pain" (p=0.02), "psychological discomfort" (p<0.01), "disability physical" (p<0.01) and "general score" (p<0.01) (n=20 patients). The IODs presented DS values ​​significantly for "aesthetics" (p=0.04), "stability" (p=0.03), "masticatory capacity" (p<0.01), "function" (p<0.01) and "oral condition" (p=0.03). The S-APS group (control) resulted in significantly lower values ​​in the dimensions "physical pain" (p<0.01) and "general score" (p<0.01) and no domain with statistical difference in the VAS scale. CONCLUSIONS: IODs significantly improved OHRQoL and DS. The increase in AP spread did not result in benefits for the patient's OHRQOL and DS in this clinical study. (Study Protocol Number: 1.452.492) CLINICAL SIGNIFICANCE: Implantology has experienced in the last 20 years a permanent evolution that aim at increasing predictability and improving long-term clinical performance. Placement of short implants distally to the mental foramen, for instance, and the resulting increase of the anterior-posterior spread, is a promising approach and is worthy of investigation.


Asunto(s)
Implantes Dentales , Boca Edéntula , Humanos , Prótesis de Recubrimiento , Calidad de Vida , Satisfacción Personal , Prótesis Dental de Soporte Implantado , Satisfacción del Paciente , Estética Dental , Boca Edéntula/psicología , Dolor
10.
J Clin Exp Dent ; 14(8): e615-e620, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36046166

RESUMEN

Background: The purpose of this in vitro study was to evaluate the color difference between the Vita Classical Shade Guide and composite veneers using the dual-layer technique. Material and Methods: Thirty samples were fabricated using a custom-made mold (Easy Layering Shade Guide Kit, 3M) using two resin composites: Filtek Supreme Ultra (3M); and Estelite Omega (Tokuyama) (n=3). The composite veneers were made by layering the different enamel and body or dentin shades from each composite. The color measurements were taken using a spectrophotometer (Vita Easyshade V®, Vita Zahnfabrik). The ΔE00 between the Vita Classical Shade Guide (Vita Zahnfabrik) and the composite veneers were calculated using the CIEDE2000 formula. Results: For the composite veneers using Filtek Supreme Ultra, the best match for A1 Vita shade was achieved layering either EA1 with DA2 or DA3; EA2 with DA1 or DA2 (ΔE00= 1.53 ~ 1.96 ± 0.4). For A2 Vita shade the best match would be EA3 with DA3 or EA3 with DA2 (ΔE00= 1.40 ~ 1.85 ± 0.1); or for A3 Vita shade the best match would be EA3 with DA2 2.50±(0.6). For the composite veneers using Estelite Omega, the were no best match for neither A1, A2 or A3 Vita shade (ΔE00> 2.5). Conclusions: The combination of enamel and dentin shades from Filtek Supreme Ultra provided acceptable color match for A1, A2 and A3 shades from the Vita Shade Guide, while Estelite Omega did not provide acceptable color match for any of the Vita Shade Guide standard shades tested. Key words:Color, color matching, optical properties, resin composite, layering.

11.
Int J Prosthodont ; 35(1): 27-36, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35230353

RESUMEN

PURPOSE: To digitally evaluate the static and dynamic occlusion of patients treated with both removable conventional complete dentures (CCDs) and implant-retained removable overdentures (IODs) and to correlate two different methods of occlusal analysis. MATERIALS AND METHODS: Eleven totally edentulous patients were treated with bimaxillary CCDs. Later, mandibular CCDs were replaced by IODs retained by either two or four implants. The distribution of the occlusal contacts in static and dynamic occlusion was compared by means of the digital method (DM; T-Scan III) and the analog method (AM; articulating paper). Scores 0, 1, and 2 were assigned for inadequate, satisfactory, and adequate distribution of the occlusal contacts, respectively. The frequencies of scores were compared in relation to the types of denture by means of Fisher exact test (P < .05). The correlation between methods was assessed by means of the kappa agreement coefficient (κ) and the correlation coefficient phi (φ) (P < .05). RESULTS: Significant differences between CCDs and IODs were found in the right lateral mandibular movement (DM, P = .024; AM, P = .008), as well as in the left lateral mandibular movement (DM, P = .035). The methods of analysis of the occlusion showed a moderate agreement (κ = 0.604; P < .001) and a moderate correlation (φ = 0.605; P < .001). CONCLUSION: The digital and analog methods showed a significant agreement and moderate correlation, irrespective of the type of complete denture. The T-Scan III digital system seems to be a consistent and reproducible method to analyze occlusion.


Asunto(s)
Implantes Dentales , Retención de Dentadura , Prótesis Dental de Soporte Implantado/métodos , Retención de Dentadura/métodos , Dentadura Completa , Dentadura Completa Inferior , Prótesis de Recubrimiento , Humanos , Mandíbula , Satisfacción del Paciente , Estudios Prospectivos , Calidad de Vida
12.
Prosthes. Esthet. Sci ; 7(26): 20-27, 20180100. ilus
Artículo en Portugués | LILACS, BBO | ID: biblio-884314

RESUMEN

Este artigo descreve o passo a passo da execução do molde em sobredentaduras mandibulares, contemplando a reprodução da área basal com excelência e a transferência dos implantes com precisão.


This article describes the mandibular overdenture impression step by step, showing the optimal reproduction of the basal area and the precise implants transference.


Asunto(s)
Humanos , Implantes Dentales , Técnica de Impresión Dental , Prótesis de Recubrimiento , Prótesis e Implantes
13.
Prosthes. Lab. Sci ; 7(25): 14-21, out.-dez. 2017. ilus
Artículo en Portugués | LILACS, BBO | ID: biblio-880534

RESUMEN

Este artigo descreve os passos para a utilização da filosofia da Técnica da Zona Neutra. Através dessa filosofia, procura-se localizar uma área, em boca, onde as forças geradas pela língua são neutralizadas pelas forças geradas pelos lábios e bochechas, estabilizando assim a prótese.


This article describes step-by-step the application of the Neutral Zone technique philosophy. It is based upon the concept that for each individual patient, there is within the denture space a specific area where the function of the musculature will not unseat the denture and where forces generated by the tongue are neutralized by the forces generated by the lips and cheeks.


Asunto(s)
Humanos , Fenómenos Biomecánicos , Técnica de Impresión Dental , Oclusión Dental Balanceada , Diseño de Dentadura/métodos , Retención de Dentadura , Dentadura Completa Inferior
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA