Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 99
Filtrar
1.
Braz Oral Res ; 37(suppl 1): e120, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38055571

RESUMEN

The aim of this paper was to present a summary of the process of developing and preparing the final documents of the national consensus for teaching undergraduate Brazilian dental students the dental caries curriculum in the Portuguese language. The final document was developed in three steps: a) The ABENO and LAOHA cariology group invited experts from all five regions of Brazil to participate in the discussion. The theoretical support for crafting the first draft of the consensus was based on two publications: National Curriculum Guidelines of the Dentistry graduation in Brazil, Ministry of Education (2021) and the competences described in the European Core Curriculum for Cariology (ORCA-ADEE, 2011); b) The group of experts was divided into 5 working groups: G1-Domain, Main and Specific Competences, G2-Essential knowledge, G3-Life course perspective, G4-Social determinants and dental caries, G5- Glossary. The document was finalized by thoroughly reviewing the process using Delphi methodology; c) The 5-chapter document (one from each working group) was submitted to three open public consultations in 2022 (May-June, August, and October) using Google-forms. The suggestions (content/wording) were discussed within the group as: totally accepted, partially accepted, and rejected. A total of 192 suggestions were registered from 31 dental schools in all regions of Brazil. The number of suggestions received per Group were: 84, 28, 26, 24, 30 suggestions for G1, G2, G3, G4 and G5, respectively. The majority of suggestions were totally accepted by the group of experts (n = 172, 89.6%), 15 were partially accepted (7.8%), and 5 were rejected. Conclusion The final document could be considered to be the first national consensus for teaching the dental caries curriculum in Brazil.


Asunto(s)
Caries Dental , Humanos , Consenso , Brasil , Caries Dental/prevención & control , Facultades de Odontología , Portugal , Educación en Odontología , Curriculum , Lenguaje
2.
Braz. oral res. (Online) ; 37(supl.1): e120, 2023. graf
Artículo en Inglés | LILACS-Express | LILACS, BBO | ID: biblio-1528138

RESUMEN

Abstract The aim of this paper was to present a summary of the process of developing and preparing the final documents of the national consensus for teaching undergraduate Brazilian dental students the dental caries curriculum in the Portuguese language. The final document was developed in three steps: a) The ABENO and LAOHA cariology group invited experts from all five regions of Brazil to participate in the discussion. The theoretical support for crafting the first draft of the consensus was based on two publications: National Curriculum Guidelines of the Dentistry graduation in Brazil, Ministry of Education (2021) and the competences described in the European Core Curriculum for Cariology (ORCA-ADEE, 2011); b) The group of experts was divided into 5 working groups: G1-Domain, Main and Specific Competences, G2-Essential knowledge, G3-Life course perspective, G4-Social determinants and dental caries, G5- Glossary. The document was finalized by thoroughly reviewing the process using Delphi methodology; c) The 5-chapter document (one from each working group) was submitted to three open public consultations in 2022 (May-June, August, and October) using Google-forms. The suggestions (content/wording) were discussed within the group as: totally accepted, partially accepted, and rejected. A total of 192 suggestions were registered from 31 dental schools in all regions of Brazil. The number of suggestions received per Group were: 84, 28, 26, 24, 30 suggestions for G1, G2, G3, G4 and G5, respectively. The majority of suggestions were totally accepted by the group of experts (n = 172, 89.6%), 15 were partially accepted (7.8%), and 5 were rejected. Conclusion The final document could be considered to be the first national consensus for teaching the dental caries curriculum in Brazil.

3.
Imaging Sci Dent ; 53(4): 335-344, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38174036

RESUMEN

Purpose: This bibliometric analysis aimed to provide a comprehensive overview of the characteristics, trends, and level of diagnostic efficacy of studies on cone-beam computed tomography (CBCT) published in Imaging Science in Dentistry (ISD) from 2011 to 2022. Materials and Methods: Publications related to CBCT identified in the electronic collection of ISD were selected according to eligibility criteria by 2 independent reviewers who collected data on the characteristics of the articles (year, authors, and country). The type and topic of studies were analyzed using VOSviewer v.1.6.18 (Centre for Science and Technology Studies, Leiden University, Leiden, Netherlands). The research articles were classified according to the hierarchical scale of diagnostic efficacy. Results: Of the 236 articles included, most were from South Korea and Brazil. Bong-Hae Cho and Yun-Hoa Jung were the most prolific authors on the topic of CBCT. The most frequently published types of studies were cross-sectional and laboratory-based. The most popular topics WERE related to the diagnosis of pathologies and/or alterations, as well as anatomical variations. On the diagnostic efficacy scale, most studies were rated level 1 (technical efficacy) or 2 (diagnostic accuracy efficacy). Conclusion: A steady increase was observed in publications related to CBCT, which are of both clinical and academic interest. The trends in these publications were analyzed, revealing that most are cross-sectional studies primarily exploring the capabilities of CBCT in diagnosing pathologies and/or changes in the oral and maxillofacial complex. These studies were typically classified as level 1 or 2 on the diagnostic efficacy scale.

4.
J Conserv Dent ; 25(5): 521-525, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36506636

RESUMEN

Context: Although preservation of the tooth structure is quoted as the main advantage of sealing of carious lesions, there are no long-term studies comparing the maintenance of dental tissue after restoration or after caries sealing. Aim: To measure the radiographically visible loss of dental tissue after conventional restoration and sealing of carious lesions. Subjects and Methods: This study was a secondary analysis of two randomized controlled clinical trials, one conducted in Brazil and another in Belgium, which evaluated two different therapies for the treatment of occlusal carious lesions in permanent teeth: sealant (SE) without previous carious tissue removal or restoration (RE) with total removal of carious dentin. The greater depth and width of sealed carious lesions and restorations were compared. Statistical Analysis: The independent t-test was used to compare therapies at different time points, while the paired t-test was used to compare the same therapy over time. Results: Carious lesions in the RE and SE groups showed similar measurements at baseline (P > 0.05). Over time, significantly greater loss of tooth structure was observed in the RE group than in the SE group. No increase in lesion depth or width was observed in the SE group, suggesting no progression of sealed lesions. Conclusion: Sealing of carious lesions resulted in greater preservation of dental tissue.

5.
Braz Oral Res ; 36: e069, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36507756

RESUMEN

This study aimed to compare the physicochemical properties of MTA Angelus (MTA-A), MTA Repair HP (MTA-HP), and Biodentine (BD). Setting times (n = 7) were determined in accordance with ASTM C266-15. Solubility (n = 11), pH (n = 10), and calcium ion release (n = 10) were evaluated up to 28 days in accordance with ANSI/ADA specification no. 57. Radiopacity was assessed by ANSI/ADA (n = 10) and the tissue simulator method (n = 10). In both methods, the specimens were radiographed using an aluminum stepwedge and the digital radiographs were analyzed in Adobe Photoshop, determining the mean grayscale pixel values of the materials, of the 3-mm aluminum stepwedge, and of the dentin, the latter of which was analyzed on the tissue simulator. The data obtained from each test were statistically analyzed and compared (p < 0.05). MTA-A presented longer final setting time compared with the other materials. There were no significant differences in the mass values of materials during the experiment. All materials presented an alkaline pH. BD promoted greater calcium ion release in most of the experimental periods. All materials presented appropriate radiopacity. BD showed lower radiopacity than MTA-A in the tissue simulator method. All groups presented higher radiopacity in the tissue simulator when compared with the ANSI/ADA method. MTA-A, MTA-HP, and BD showed appropriate physicochemical properties and radiopacity, and were considered suitable to be used in clinical practice.


Asunto(s)
Compuestos de Aluminio , Materiales de Obturación del Conducto Radicular , Compuestos de Aluminio/química , Materiales de Obturación del Conducto Radicular/química , Calcio , Aluminio , Ensayo de Materiales , Silicatos/química , Compuestos de Calcio/química , Óxidos/química , Combinación de Medicamentos
6.
Braz Oral Res ; 36: e053, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35442382

RESUMEN

This study assessed the ability of XP-endo Finisher R (FKG, La Chaux-de-Fonds, Switzerland) to remove filling remnants from curved mesiobuccal canals of maxillary molars, using the passive ultrasonic irrigation (PUI) technique as a comparison. Twenty-four curved main mesiobuccal canals (MB1) of maxillary molars were instrumented with Wave One (#25/07) and filled with gutta-percha points and AH Plus Sealer. Samples were then re-treated with a standardized protocol with Wave One (#35/06) as the master apical file. Micro-CT scans measured baseline volume of remaining filling material (in mm3). Samples were divided into two groups (n = 12) according to the supplementary cleaning approach: (PUI) or XP-endo Finisher R. Statistics compared baseline and final volume of filling material (within-group); and the percentage of filling material reduction (between-group). Mean baseline volumes, final volumes, and percentages of reduction (%) of filling material for XP-endo Finisher R and PUI were respectively: 0.060 mm3, 0.042 mm3, and 31.28%; and 0.064 mm3, 0.054 mm3, and 16.57%. Both tested protocols reduced the amount of filling material (p < 0.05). XP-endo Finisher R had higher percentage of reduction as compared to PUI (p < 0.05). XP-endo Finisher R and PUI used as supplementary cleaning protocols during re-treatment improved the removal of root filling material in curved canals; but XP-endo Finisher R was approximately twice more efficient. The complete filling material removal during re-treatment procedures is still a challenge. Supplementary cleaning protocols may help to remove the remaining material after the complete mechanical preparation of curved canals. XP-endo Finisher R was approximately twice more efficient than PUI.


Asunto(s)
Materiales de Obturación del Conducto Radicular , Obturación del Conducto Radicular , Cavidad Pulpar/diagnóstico por imagen , Retratamiento , Materiales de Obturación del Conducto Radicular/uso terapéutico , Preparación del Conducto Radicular , Ultrasonido
7.
Braz. oral res. (Online) ; 36: e069, 2022. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO | ID: biblio-1374746

RESUMEN

Abstract: This study aimed to compare the physicochemical properties of MTA Angelus (MTA-A), MTA Repair HP (MTA-HP), and Biodentine (BD). Setting times (n = 7) were determined in accordance with ASTM C266-15. Solubility (n = 11), pH (n = 10), and calcium ion release (n = 10) were evaluated up to 28 days in accordance with ANSI/ADA specification no. 57. Radiopacity was assessed by ANSI/ADA (n = 10) and the tissue simulator method (n = 10). In both methods, the specimens were radiographed using an aluminum stepwedge and the digital radiographs were analyzed in Adobe Photoshop, determining the mean grayscale pixel values of the materials, of the 3-mm aluminum stepwedge, and of the dentin, the latter of which was analyzed on the tissue simulator. The data obtained from each test were statistically analyzed and compared (p < 0.05). MTA-A presented longer final setting time compared with the other materials. There were no significant differences in the mass values of materials during the experiment. All materials presented an alkaline pH. BD promoted greater calcium ion release in most of the experimental periods. All materials presented appropriate radiopacity. BD showed lower radiopacity than MTA-A in the tissue simulator method. All groups presented higher radiopacity in the tissue simulator when compared with the ANSI/ADA method. MTA-A, MTA-HP, and BD showed appropriate physicochemical properties and radiopacity, and were considered suitable to be used in clinical practice.

8.
Braz. oral res. (Online) ; 36: e053, 2022. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO | ID: biblio-1374749

RESUMEN

Abstract: This study assessed the ability of XP-endo Finisher R (FKG, La Chaux-de-Fonds, Switzerland) to remove filling remnants from curved mesiobuccal canals of maxillary molars, using the passive ultrasonic irrigation (PUI) technique as a comparison. Twenty-four curved main mesiobuccal canals (MB1) of maxillary molars were instrumented with Wave One (#25/07) and filled with gutta-percha points and AH Plus Sealer. Samples were then re-treated with a standardized protocol with Wave One (#35/06) as the master apical file. Micro-CT scans measured baseline volume of remaining filling material (in mm3). Samples were divided into two groups (n = 12) according to the supplementary cleaning approach: (PUI) or XP-endo Finisher R. Statistics compared baseline and final volume of filling material (within-group); and the percentage of filling material reduction (between-group). Mean baseline volumes, final volumes, and percentages of reduction (%) of filling material for XP-endo Finisher R and PUI were respectively: 0.060 mm3, 0.042 mm3, and 31.28%; and 0.064 mm3, 0.054 mm3, and 16.57%. Both tested protocols reduced the amount of filling material (p < 0.05). XP-endo Finisher R had higher percentage of reduction as compared to PUI (p < 0.05). XP-endo Finisher R and PUI used as supplementary cleaning protocols during re-treatment improved the removal of root filling material in curved canals; but XP-endo Finisher R was approximately twice more efficient. The complete filling material removal during re-treatment procedures is still a challenge. Supplementary cleaning protocols may help to remove the remaining material after the complete mechanical preparation of curved canals. XP-endo Finisher R was approximately twice more efficient than PUI.

9.
Clinics (Sao Paulo) ; 76: e3056, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34614114

RESUMEN

OBJECTIVES: Owing to the fact that obstructive sleep apnea (OSA) is an underreported disease, the strategy used for the diagnosis of OSA has been extensively dissected to devise a simplified process that can be accessed by the public health services. Polysomnography (PSG) type I, the gold standard for the diagnosis of OSA, is expensive and difficult to access by low-income populations. In this study, we aimed to verify the accuracy of the oxyhemoglobin desaturation index (ODI) in comparison to the apnea-hypopnea index (AHI) using a portable monitor. METHODS: We evaluated 94 type III PSG home test results of 65 elderly patients (69.21±6.94 years old), along with information, such as the body mass index (BMI) and sex, using data obtained from a clinical trial database. RESULTS: A significant linear positive correlation (r=0.93, p<0.05) was observed between ODI and AHI, without any interference from sex, BMI, and positional component. The sensitivity of ODI compared to that of AHI increased with an increase in the severity of OSA, while the specificity of ODI in comparison to that of AHI was high for all degrees of severity. The accuracy of ODI was 80.7% for distinguishing between patients with mild and moderate apnea and 84.4% for distinguishing between patients with moderate and severe apnea. CONCLUSION: The ODI values obtained in uncontrolled conditions exhibited high sensitivity for identifying severe apnea compared to the AHI values, and correctly identified the severity of OSA in more than 80% of the cases. Thus, oximetry is promising strategy for diagnosing OSA.


Asunto(s)
Apnea Obstructiva del Sueño , Anciano , Índice de Masa Corporal , Humanos , Persona de Mediana Edad , Oximetría , Polisomnografía , Apnea Obstructiva del Sueño/diagnóstico
10.
J. res. dent ; 9(5): 15-19, sep.-oct2021.
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1362914

RESUMEN

Introduction: Different NiTi rotary systems have been developed to improve efficiency and retreatment success rates. Aim: To evaluate the Protaper Universal retreatment system and WaveOne instrument in removing the filling material from curved canals during retreatment. Materials and Methods: Thirty mesial root canals of extracted human mandibular molar teeth were randomly allocated into 2 groups (n=15). In the PT group, retreatment was performed with ProTaper Universal Retreatment according to the manufacturer's instructions. In the WO group, was used WaveOne Primary. ProTaper Universal F2 and F3 were used to achieve the apical diameter in both groups. The samples were scanned by micro-computed tomography pre and postoperatively to evaluate the filling material remaining. The percentage of material filling was compared between groups using Student's T test and in the same group among thirds was compared using Kruskal-Wallis followed by Dunn's post hoc test. Results: The filling material remaining was not statistically different between the groups (p≥0.05). The apical third presented a greater amount of remaining filling material when compared with the cervical third for both groups (p<0.05). Conclusion: Rotary and reciprocating techniques can effectively, but not completely, remove the filling materials from the root canal system. The apical third presented a more significant amount of remaining filling material.

11.
Clinics ; 76: e3056, 2021. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1339714

RESUMEN

OBJECTIVES: Owing to the fact that obstructive sleep apnea (OSA) is an underreported disease, the strategy used for the diagnosis of OSA has been extensively dissected to devise a simplified process that can be accessed by the public health services. Polysomnography (PSG) type I, the gold standard for the diagnosis of OSA, is expensive and difficult to access by low-income populations. In this study, we aimed to verify the accuracy of the oxyhemoglobin desaturation index (ODI) in comparison to the apnea-hypopnea index (AHI) using a portable monitor. METHODS: We evaluated 94 type III PSG home test results of 65 elderly patients (69.21±6.94 years old), along with information, such as the body mass index (BMI) and sex, using data obtained from a clinical trial database. RESULTS: A significant linear positive correlation (r=0.93, p<0.05) was observed between ODI and AHI, without any interference from sex, BMI, and positional component. The sensitivity of ODI compared to that of AHI increased with an increase in the severity of OSA, while the specificity of ODI in comparison to that of AHI was high for all degrees of severity. The accuracy of ODI was 80.7% for distinguishing between patients with mild and moderate apnea and 84.4% for distinguishing between patients with moderate and severe apnea. CONCLUSION: The ODI values obtained in uncontrolled conditions exhibited high sensitivity for identifying severe apnea compared to the AHI values, and correctly identified the severity of OSA in more than 80% of the cases. Thus, oximetry is promising strategy for diagnosing OSA.


Asunto(s)
Humanos , Persona de Mediana Edad , Anciano , Apnea Obstructiva del Sueño/diagnóstico , Oximetría , Índice de Masa Corporal , Polisomnografía
12.
Braz. oral res. (Online) ; 35: e009, 2021. graf
Artículo en Inglés | LILACS, BBO | ID: biblio-1132746

RESUMEN

Abstract: This study analyzed the consequences of the disordered expansion of Dentistry courses on the distribution of professionals, the job market, and limitations of the National System of Higher Education Assessment (SINAES) developed as a guarantee of education quality. This observational, descriptive, and analytical study used secondary data from several official databases. The number of courses was obtained from the e-MEC registry. From the Higher Education Census, the study collected historical series of courses offered, number of candidates per open seat, number of individuals who initiated and completed the course, and information about professors in the public and private schools. The reports related to Dentistry courses from the National Health Council were also analyzed. The performance of undergraduate students was assessed from synthesis reports of Enade from 2004 to 2016. The number of dentists and their regional distribution was based on the Federal Dental Council, and Brazilian population and gross domestic product were collected from the Brazilian Institute of Geography and Statistics. Dentistry courses in Brazil grew exponentially from 1856 to 2020; among the 544 authorized courses, 82 currently have not yet started their activities. The fast expansion of courses in Brazil has worsened the regional asymmetries in the supply of dentist, and the SINAES has not been able to fully assure the quality of Dentistry courses. Brazilian dentistry, which has increased its scientific and technological development since the 19th century, with outstanding intellectual production, is at risk of a collapse due to a plethora of dentists.


Asunto(s)
Humanos , Instituciones Académicas , Estudiantes , Brasil , Odontología , Escolaridad
13.
Braz Oral Res ; 35: e009, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33206782

RESUMEN

This study analyzed the consequences of the disordered expansion of Dentistry courses on the distribution of professionals, the job market, and limitations of the National System of Higher Education Assessment (SINAES) developed as a guarantee of education quality. This observational, descriptive, and analytical study used secondary data from several official databases. The number of courses was obtained from the e-MEC registry. From the Higher Education Census, the study collected historical series of courses offered, number of candidates per open seat, number of individuals who initiated and completed the course, and information about professors in the public and private schools. The reports related to Dentistry courses from the National Health Council were also analyzed. The performance of undergraduate students was assessed from synthesis reports of Enade from 2004 to 2016. The number of dentists and their regional distribution was based on the Federal Dental Council, and Brazilian population and gross domestic product were collected from the Brazilian Institute of Geography and Statistics. Dentistry courses in Brazil grew exponentially from 1856 to 2020; among the 544 authorized courses, 82 currently have not yet started their activities. The fast expansion of courses in Brazil has worsened the regional asymmetries in the supply of dentist, and the SINAES has not been able to fully assure the quality of Dentistry courses. Brazilian dentistry, which has increased its scientific and technological development since the 19th century, with outstanding intellectual production, is at risk of a collapse due to a plethora of dentists.


Asunto(s)
Instituciones Académicas , Estudiantes , Brasil , Odontología , Escolaridad , Humanos
15.
Clin Oral Investig ; 23(4): 1837-1844, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30215147

RESUMEN

OBJECTIVES: This study aimed to compare WaveOne Gold with ProTaper and RaCe systems regarding remaining filling material, apical transportation (AT), and working time (WT) after (i) filling removal and (ii) shaping of curved canals. METHODS: Thirty mesiobuccal canals of maxillary molars were prepared and filled. After 30 days, they were randomly assigned into three groups (n = 10), according to the instruments used for filling removal and shaping, respectively: WOG-WaveOne Gold Primary and Medium; PTG-ProTaper Retreatment and ProTaper Next; RCG-D-RaCe and RaCe. Micro-CT analysis assessed the residual filling material and AT. WT was recorded. Data were statistically analyzed (α = .05). RESULTS: There was no significant difference between groups in the amount of filling material at any evaluated moment (P > .05). All groups presented low AT values. The WT was similar in all groups in filling removal (P > .05), and in shaping step WOG was faster than PTG and RCG (P < .05). CONCLUSIONS: Neither system could completely remove the filling material. The instruments evaluated were safe and the reciprocating system was faster than the rotary systems in shaping the canals. CLINICAL RELEVANCE: This study provided consistent information on filling material removal capacity of WaveOne Gold. Considering that all tested systems were safe, WaveOne Gold may be an alternative with cost-effectiveness and shorter learning curve for endodontic retreatment.


Asunto(s)
Obturación del Conducto Radicular , Preparación del Conducto Radicular/instrumentación , Microtomografía por Rayos X , Cavidad Pulpar , Humanos , Retratamiento , Materiales de Obturación del Conducto Radicular
17.
Gen Dent ; 66(3): 26-31, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29714696

RESUMEN

Endodontic management of 3-rooted maxillary premolars is a challenge due to their complex anatomy and narrow root canal walls. This study aimed to evaluate, by microcomputed tomography (µCT), the apical enlargement and centering ability promoted by hand, rotary, and reciprocating instrumentation in 3-rooted maxillary premolars. Eighteen teeth were divided into 3 groups (n = 6) according to the preparation technique: crown-down hand, rotary, and reciprocating instrumentation. Instruments with similar apical diameters were used (25 and 40 mm for buccal and palatal canals, respectively). Centering ability and canal enlargement were evaluated through the comparison of µCT images obtained before and after instrumentation. Distances of 0, 2, 4, and 6 mm from the apical stop were considered. Differences between canal areas before and after instrumentation were calculated. In addition, distances between the original canal center and the prepared canal center at the apical stop were measured in both the mesiodistal and buccopalatal directions. Significant differences in enlargement areas and centering ability among the techniques were determined using 2-way analysis of variance and Tukey post hoc test (P > 0.05). Root canal enlargement was similar for all techniques. Excessive enlargement was observed in only a few specimens, and root perforation did not occur. Some specimens presented untreated canal areas. In mesiobuccal and distobuccal roots, reciprocating instrumentation promoted more centered preparations than hand instrumentation when measured in the mesiodistal direction (P > 0.05). There were no other statistically significant differences. The results established that hand, rotary, and reciprocating techniques presented similar safety margins for instrumentation of the apical third of 3-rooted maxillary premolars. Reciprocating instrumentation presented some advantages over hand preparation regarding centering ability.


Asunto(s)
Diente Premolar/anomalías , Radiografía Dental , Preparación del Conducto Radicular/métodos , Raíz del Diente/anomalías , Microtomografía por Rayos X , Diente Premolar/diagnóstico por imagen , Diente Premolar/cirugía , Humanos , Maxilar , Preparación del Conducto Radicular/instrumentación , Raíz del Diente/diagnóstico por imagen , Raíz del Diente/cirugía
18.
Braz Dent J ; 28(5): 592-596, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29215684

RESUMEN

The aim of this study was to evaluate the radiopacity of different gutta-percha points (Endo Points®, Dentsply®, Tanari®, Meta®, Roeko® and Odous®) in samples of 1 mm thick as established by ANSI/ADA Specification #57 and ISO 6876/2001, in comparison with thinner samples. Twelve test specimens for each material, four for each thickness (0.3, 0.6, and 1 mm and diameter of 8 mm), were laminated and compressed between two polished glass plates until the desirable thickness. Digital radiographs were obtained along with a graduated aluminum stepwedge varying from 1 to 10 mm in thickness. The X-ray unit was set at 70 kVp, 10 mA and 0.4 s exposure time, at a focal distance of 36 cm. One calibrated observer quantified the average values of pixels with Adobe Photoshop® software. Data were analyzed using ANOVA and Tukey tests, at 5% significance level. At 0.6 and 1 mm thickness, all the tested materials showed radiopacity higher than 3 mm of aluminum (reference value). At 0.3 mm thickness, Odous and Tanari presented significantly less radiopacity than the reference, and the other materials showed similar radiopacity to the reference. The study concluded that the materials demonstrated different radiopacities and all had values above the minimum recommended by ANSI/ADA specification #57, being Odous and Tanari less radiopaque than the reference value in thinner samples (0.3mm).


Asunto(s)
Gutapercha , Ensayo de Materiales
19.
Rev. Bras. Odontol. Leg. RBOL ; 4(3): [13-23], set.-dez.2017.
Artículo en Portugués | LILACS, BBO | ID: biblio-912413

RESUMEN

Introdução: A determinação do desenvolvimento esquelético é uma prática comum ao exercício da Odontologia, tanto para fins ortodônticos quanto forenses. Diversos métodos utilizam radiografias e, tendo em vista o crescente emprego da tomografia computadorizada, torna-se importante o conhecimento de todas as potencialidades destas imagens na prática pericial. Objetivo: O objetivo deste estudo foi descrever parâmetros morfológicos das vértebras cervicais C1 e C2 em imagens axiais de tomografia computadorizada por feixe cônico (TCFC) em cada um dos seis estágios maturacionais propostos por Hassel e Farman (1995) para a análise das vértebras no plano sagital. Material e Método: A partir de um banco de dados, foram avaliadas imagens de TCFC de 73 indivíduos de 8 a 18 anos, as quais foram classificadas no plano sagital. Em seguida, as vértebras C1 e C2 foram avaliadas no plano axial e suas características morfológicas registradas em um instrumento de coleta de dados. Foram, então, calculados os percentuais de cada característica dentro dos estágios maturacionais. Resultados: Observou-se na caracterização morfológica axial da C2 a tendência de fusionamento da sincondrose subdental nas fases de Maturação (5) e Finalização (6), ocorrendo em 90% e 66,6% dos casos, respectivamente. Conclusão: O estudo identificou padrões morfológicos axiais da C2 predominantes nas fases 5 e 6 de maturação das vértebras cervicais propostas por Hassel e Farman (1995), podendo contribuir para casos forenses de estimativa da idade.


Introduction: The skeletal development determination is a common practice in Dentistry, both for orthodontic and for forensic purposes. Several methods are based on radiographs, but considering the increase in computed tomography exams more contemporary investigations of these methods became important to explore their forensic purposes. Objective: This study aimed to describe the morphological parameters of the C1 and C2 vertebrae in axial cone beam computed tomography (CBCT) images, at each of the six maturational stages proposed by Hassel and Farman. Material and Method: From a database, CBCT images of 73 individuals aged 8 to 18 years were evaluated and classified in the sagittal plane. Then the C1 and C2 vertebrae were evaluated in the axial plane and their morphological characteristics were recorded in a data collection instrument. The percentage of each feature within the maturational stages was calculated. Results: In the axial morphological characterization of C2, the tendency of fusion of the subdental was marked in Maturation (5) and Finishing (6) phases, with 90% and 66.6% of cases, respectively. Conclusion: The study identified axial morphological patterns of C2 that predominate in phases 5 and 6 of maturation of the cervical vertebrae proposed by Hassel and Farman, and may contribute to age estimation in forensic cases.


Asunto(s)
Humanos , Masculino , Femenino , Vértebras Cervicales , Tomografía Computarizada de Haz Cónico , Odontología Forense , Antropología Forense , Crecimiento y Desarrollo
20.
Braz. dent. j ; 28(5): 592-596, Sept.-Oct. 2017. tab, graf
Artículo en Inglés | LILACS | ID: biblio-888696

RESUMEN

Abstract The aim of this study was to evaluate the radiopacity of different gutta-percha points (Endo Points®, Dentsply®, Tanari®, Meta®, Roeko® and Odous®) in samples of 1 mm thick as established by ANSI/ADA Specification #57 and ISO 6876/2001, in comparison with thinner samples. Twelve test specimens for each material, four for each thickness (0.3, 0.6, and 1 mm and diameter of 8 mm), were laminated and compressed between two polished glass plates until the desirable thickness. Digital radiographs were obtained along with a graduated aluminum stepwedge varying from 1 to 10 mm in thickness. The X-ray unit was set at 70 kVp, 10 mA and 0.4 s exposure time, at a focal distance of 36 cm. One calibrated observer quantified the average values of pixels with Adobe Photoshop® software. Data were analyzed using ANOVA and Tukey tests, at 5% significance level. At 0.6 and 1 mm thickness, all the tested materials showed radiopacity higher than 3 mm of aluminum (reference value). At 0.3 mm thickness, Odous and Tanari presented significantly less radiopacity than the reference, and the other materials showed similar radiopacity to the reference. The study concluded that the materials demonstrated different radiopacities and all had values above the minimum recommended by ANSI/ADA specification #57, being Odous and Tanari less radiopaque than the reference value in thinner samples (0.3mm).


Resumo O objetivo deste estudo foi avaliar a radipacidade de diferentes pontas de guta-percha (Endo Points®, Dentsply®, Tanari®, Meta®, Roeko® e Odous®) em amostras de 1 mm de espessura, conforme estabelecido pela especificação #57 da ANSI/ADA e pela ISO 6876/2001, em comparação com amostras de menor espessura. Doze amostras de cada material, quatro para cada espessura (0,3, 0,6 e 1 mm; 8 mm de diâmetro), foram confeccionadas por meio de laminação e compressão entre duas lâminas de vidro polidas, até a espessura desejada. Radiografias digitais foram obtidas juntamente com uma escala de alumínio graduada, com espessuras variando de 1 a 10 mm. O aparelho de raios X foi ajustado para 70 kVp, 10 mA, 0,4s de tempo de exposição, com distância focal de 36 cm. Um observador calibrado quantificou a média dos valores de pixel no programa Adobe Photoshop®. Os dados foram analisados utilizando os testes ANOVA e Tukey, com nível de significância de 5%. Nas espessuras de 0,6 e 1 mm, todos os materiais testados apresentaram radiopacidade maior do que 3 mm de alumínio (valor de referência). Na espessura de 0,3 mm, Odous e Tanari apresentaram radiopacidade significativamente menor que a referência, e as outras marcas mostraram radiopacidade semelhante à referência. Conclui-se que os materiais apresentaram diferentes radiopacidades e todos mostraram valores acima do mínimo recomendado pela especificação #57 da ANSI/ADA, sendo Odous e Tanari menos radiopacos do que o valor de referência nas amostras mais finas (0.3 mm).


Asunto(s)
Gutapercha , Ensayo de Materiales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA