1.
Osteoporos Int ; 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38767743

RESUMEN

This study investigates the effects of antiresorptive drugs and risk factors for medication-related osteonecrosis of the jaws in osteoporotic patients undergoing tooth extraction. Among the findings, antiresorptive-treated patients had thicker lamina dura and longer healing times. Additionally, corticosteroid intake and multi-rooted teeth carried a higher osteonecrosis risk. Bone sequestrum indicated osteonecrosis. PURPOSE: To describe the effects of antiresorptive drugs (ARD) in the maxilla and mandible and risk factors for medication-related osteonecrosis of the jaws (MRONJ) in osteoporotic patients undergoing tooth extractions using clinical data and cone beam computed tomography (CBCT). METHODS: This retrospective cohort study collected clinical and CBCT data from 176 patients. The study group (n = 78; 224 extractions) received ARD treatment, underwent tooth extraction, and had a pre-operative CBCT. Additionally, age-, sex-, and tooth-matched controls were selected (n = 98; 227 extractions). Radiographic examinations were performed independently by three calibrated examiners. Statistical analysis included Chi-square, Fisher's exact, Mann-Whitney U, and t-tests to contrast clinical and radiographic data between study and control, MRONJ + and MRONJ - , and bisphosphonate and denosumab patients/sites. Significance was set at p ≤ 0.05. RESULTS: From the study group, 4 patients (5%) and 5 sites (2%) developed MRONJ after tooth extraction. ARD-treated patients exhibited significantly more thickening of the lamina dura and a longer average mucosal healing time (4.4 weeks) than controls (2.6 weeks). In the study group, MRONJ risk significantly increased with corticosteroid intake and in multi-rooted teeth. No significant differences between bisphosphonates and denosumab use were seen in the tomographic features (p > 0.05). Lastly, bone sequestrum was exclusively observed in osteoporotic patients, who exhibited post-operative exposed bone or histological evidence of osteonecrosis. CONCLUSION: Osteoporotic patients under ARD may exhibit thickening of the lamina dura and prolonged post-operative healing. Among these patients, multi-rooted teeth are at higher risk for MRONJ than single-rooted teeth. Sequester formation is a radiographic indicator of osteonecrosis.

2.
Int J Paediatr Dent ; 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38769619

RESUMEN

BACKGROUND: Primary teeth segmentation on cone beam computed tomography (CBCT) scans is essential for paediatric treatment planning. Conventional methods, however, are time-consuming and necessitate advanced expertise. AIM: The aim of this study was to validate an artificial intelligence (AI) cloud-based platform for automated segmentation (AS) of primary teeth on CBCT. Its accuracy, time efficiency, and consistency were compared with manual segmentation (MS). DESIGN: A dataset comprising 402 primary teeth (37 CBCT scans) was retrospectively retrieved from two CBCT devices. Primary teeth were manually segmented using a cloud-based platform representing the ground truth, whereas AS was performed on the same platform. To assess the AI tool's performance, voxel- and surface-based metrics were employed to compare MS and AS methods. Additionally, segmentation time was recorded for each method, and intra-class correlation coefficient (ICC) assessed consistency between them. RESULTS: AS revealed high performance in segmenting primary teeth with high accuracy (98 ± 1%) and dice similarity coefficient (DSC; 95 ± 2%). Moreover, it was 35 times faster than the manual approach with an average time of 24 s. Both MS and AS demonstrated excellent consistency (ICC = 0.99 and 1, respectively). CONCLUSION: The platform demonstrated expert-level accuracy, and time-efficient and consistent segmentation of primary teeth on CBCT scans, serving treatment planning in children.

3.
J Dent ; 143: 104862, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38336018

RESUMEN

OBJECTIVES: To conduct a scoping review focusing on artificial intelligence (AI) applications in presurgical dental implant planning. Additionally, to assess the automation degree of clinically available pre-surgical implant planning software. DATA AND SOURCES: A systematic electronic literature search was performed in five databases (PubMed, Embase, Web of Science, Cochrane Library, and Scopus), along with exploring gray literature web-based resources until November 2023. English-language studies on AI-driven tools for digital implant planning were included based on an independent evaluation by two reviewers. An assessment of automation steps in dental implant planning software available on the market up to November 2023 was also performed. STUDY SELECTION AND RESULTS: From an initial 1,732 studies, 47 met eligibility criteria. Within this subset, 39 studies focused on AI networks for anatomical landmark-based segmentation, creating virtual patients. Eight studies were dedicated to AI networks for virtual implant placement. Additionally, a total of 12 commonly available implant planning software applications were identified and assessed for their level of automation in pre-surgical digital implant workflows. Notably, only six of these featured at least one fully automated step in the planning software, with none possessing a fully automated implant planning protocol. CONCLUSIONS: AI plays a crucial role in achieving accurate, time-efficient, and consistent segmentation of anatomical landmarks, serving the process of virtual patient creation. Additionally, currently available systems for virtual implant placement demonstrate different degrees of automation. It is important to highlight that, as of now, full automation of this process has not been documented nor scientifically validated. CLINICAL SIGNIFICANCE: Scientific and clinical validation of AI applications for presurgical dental implant planning is currently scarce. The present review allows the clinician to identify AI-based automation in presurgical dental implant planning and assess the potential underlying scientific validation.


Asunto(s)
Implantes Dentales , Humanos , Implantación Dental Endoósea/métodos , Inteligencia Artificial , Imagenología Tridimensional/métodos , Programas Informáticos
4.
Odontology ; 2024 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-38214844

RESUMEN

This study aimed to evaluate the influence of the metal post composition, tooth location in the dental arch, and metal artifact reduction (MAR) on vertical root fracture (VRF) diagnosis in cone beam computed tomography (CBCT). Twenty-two unirradicular premolars (12 sound and 10 fractured) and two alveolar sockets of a mandible (anterior and posterior regions) composed the sample. CBCT scans of each tooth with a metal post placed into the root canal-silver-palladium (Ag-Pd), cobalt-chromium (Co-Cr), or nickel-chromium (Ni-Cr)-were individually acquired for each mandibular region, and two conditions of MAR, using a OP300 device (Instrumentarium, Finland). Images were assessed by five evaluators independently for VRF detection. Diagnostic values were calculated and compared among all groups using multi-way ANOVA with Tukey post hoc test to investigate the effect of post material, anatomical region, and MAR on VRF diagnosis (α = 0.05). Values of area under the receiver operating curve and specificity were not influenced by the studied factors (p > 0.05). Sensitivity was influenced by the MAR in both mandibular regions (p < 0.05). In the anterior region, sensitivity values increased when the MAR was enabled, regardless of the metal post material (p < 0.05). Similar behavior was noticed in the posterior region for Ni-Cr (p < 0.05) but not for Ag-Pd and Co-Cr posts (p > 0.05). The MAR improved the sensitivity in VRF diagnosis for all tested metal posts in the mandibular anterior region and for the Ni-Cr post in the mandibular posterior region. Therefore, for images obtained in the OP300 CBCT device, activation of the MAR is suggested in these cases.

5.
Artículo en Inglés | MEDLINE | ID: mdl-37940483

RESUMEN

OBJECTIVE: We evaluated the influence of an adjacent zirconium implant, tube current (mA), and a metal artifact reduction algorithm (MARA) on horizontal root fracture (HRF) diagnosis in cone beam computed tomography (CBCT). STUDY DESIGN: Nineteen teeth (9 with HRF, 10 without) were individually placed in a human maxilla. Scan volumes were acquired without and with a zirconium implant adjacent to the tooth at settings of 4, 8, and 10 mA, with MARA disabled and enabled, using a 5×5 cm field of view, 0.085-mm voxel size, and 90 kV. Four maxillofacial radiologists individually assessed the scans. Diagnostic metrics were compared by multiway analysis of variance (α=5%). Inter- and intraexaminer agreements for HRF diagnosis were evaluated with the weighted kappa test. RESULTS: Area under the receiver operating characteristic curve (AUC), sensitivity, and specificity were significantly lower in the presence of the implant (P≤.005). AUC values were higher in scans obtained with 8 and 10 mA compared with 4 mA (P=0.010), but 10 mA without MARA was better with the implant present. MARA did not significantly influence outcomes (P≥0.240). Inter- and intraexaminer agreements ranged from moderate to almost perfect. CONCLUSIONS: The presence of the zirconium implant impairs HRF detection. Settings of 8 or 10 mA improve HRF detection regardless MARA condition without the implant. With an adjacent implant, 10 mA without MARA is recommended to improve diagnostic performance.


Asunto(s)
Fracturas de los Dientes , Raíz del Diente , Humanos , Raíz del Diente/diagnóstico por imagen , Circonio , Fracturas de los Dientes/diagnóstico por imagen , Artefactos , Tomografía Computarizada de Haz Cónico/métodos , Algoritmos
6.
Artículo en Inglés | MEDLINE | ID: mdl-37838553

RESUMEN

OBJECTIVE: We evaluated artifact expression in a root adjacent to a dental implant located in the endomass or exomass in cone beam computed tomography (CBCT). STUDY DESIGN: We placed a single titanium or zirconia implant adjacent to a premolar root in a dried human mandible and acquired CBCT scans using an OP300 Maxio and a Picasso Trio 3D unit exposing a 5x5cm field of view with the implant in the endomass or exomass (implant groups) or without an implant (control group). We measured the mean gray values (MGVs) for 8 lines of interest (LOIs) around the root canal of the premolar and compared the MGVs by analysis of variance, with significance established at P < 0.05. RESULTS: For the OP300 Maxio scans, the MGVs of both implant groups in the endomass were lower than the MGVs of the control group. In the exomass, the titanium group had MGVs similar to the control group, but the zirconia group produced significantly lower MGVs than control and titanium groups (P <.0001), indicating the presence of hypodense artifacts. For the Picasso Trio 3D scans, the MGVs of both implant groups in the endomass were similar to the MGVs of the control group. In the exomass, the zirconia group generated lower MGVs than control and titanium groups (P <.0001), indicating hypodense artifacts. CONCLUSIONS: When performing CBCT examination, titanium implants produce less artifact expression in the exomass, and zirconia implants have less artifact expression in the endomass.


Asunto(s)
Implantes Dentales , Titanio , Humanos , Artefactos , Circonio , Tomografía Computarizada de Haz Cónico/métodos
7.
Braz Dent J ; 34(4): 150-157, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37909638

RESUMEN

This study aimed to assess the influence of the file format on the image quality parameters (image noise, brightness, and uniformity) of periapical radiographs acquired with different digital systems. Radiographic images of an acrylic phantom were acquired with two digital systems - Digora Toto and Express, and exported into five different file formats - TIFF, BMP, DICOM, PNG, and JPEG. Image noise, image brightness (mean of gray values), and image uniformity (standard deviation of gray values) were evaluated in all images. A two-way analysis of variance with Tukey's test as a post-hoc test was used to compare the results, considering the file formats and radiographic systems as the studied factors. A significance level of 5% was adopted for all analyses. The DICOM image file format presented lower image noise, higher brightness (higher mean gray values), and greater image uniformity (p<0.001) than the other file formats, which did not differ from each other for both digital radiography systems (p>0.05). The Express system revealed lower image noise and greater image uniformity than the Digora Toto system regardless of the image file format (p<0.001). Moreover, the Express showed higher brightness than the Digora Toto for all image file formats (p<0.001), except for the DICOM image file format, which did not significantly differ between the digital radiography systems tested (p>0.05). The DICOM image file format showed lower image noise, higher brightness, and greater image uniformity than the other file formats (TIFF, BMP, PNG, and JPEG) in both digital radiography systems tested.


Asunto(s)
Radiografía Dental Digital , Radiografía Dental Digital/métodos
8.
Dentomaxillofac Radiol ; 52(8): 20230304, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37870051

RESUMEN

OBJECTIVES: To identify clinical and tomographic prognostic factors for conservative and surgical treatment of medication-related osteonecrosis of the jaws (MRONJ). METHODS: A retrospective search identified patients treated with antiresorptive drugs (ARDs), diagnosed with Stage 1, 2 or 3 MRONJ, and having CBCT scans previous to conservative or surgical treatment. Following data collection, imaging assessment of the following parameters on each MRONJ site was performed: involvement of teeth and/or implants, presence of osteosclerosis, osteolysis, sequestrum formation, periosteal reaction, and pathological fractures. For statistical analysis, patients and lesions were divided into conservative and surgical treatment. Comparisons were made between successful and unsuccessful outcomes. Significance was set at p ≤ 0.05. RESULTS: 115 ARD-treated patients who developed 143 osteonecrosis lesions were selected. 40 patients and 58 lesions received conservative treatment, of which 14 patients (35%) and 25 lesions (43%) healed. Additionally, 75 patients and 85 lesions underwent surgery, with 48 patients (64%) and 55 lesions (65%) that healed. Clinical and tomographic risk factors for conservative treatment were MRONJ staging, tooth involvement, extensive osteosclerosis, and deep sequestrum formation (p < 0.05). Complementarily, poor prognostic indicators for surgical therapy were a short bisphosphonate (BP) holiday, MRONJ staging, absence of sequestrum formation, and presence of periosteal reaction (p < 0.05). CONCLUSIONS: Lesions at Stage 3 MRONJ, with tooth involvement, or sequestrum formation showed poor outcomes when conservative treatment is chosen. Alternatively, surgical treatment is most effective when BPs are discontinued, in Stage 1 lesions, in the presence of sequestrum formation, and absence of periosteal reaction.


Asunto(s)
Osteonecrosis de los Maxilares Asociada a Difosfonatos , Conservadores de la Densidad Ósea , Osteosclerosis , Humanos , Osteonecrosis de los Maxilares Asociada a Difosfonatos/diagnóstico por imagen , Osteonecrosis de los Maxilares Asociada a Difosfonatos/cirugía , Estudios Retrospectivos , Conservadores de la Densidad Ósea/efectos adversos , Pronóstico , Osteosclerosis/diagnóstico por imagen
9.
Clin Oral Investig ; 27(11): 6451-6460, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37728617

RESUMEN

OBJECTIVES: To compare the multilayer panoramic radiography (MPAN) and conventional panoramic radiography (CPAN) in the evaluation of mandibular third molars using cone-beam computed tomography (CBCT) as a reference. METHODS: CPAN, MPAN, and CBCT scans from 33 dry human mandibles were acquired using the OP300 Maxio unit, totalizing 56 mandibular third molars to be evaluated. Three examiners evaluated each third molar according to their position, depth of impaction in the mandibular ramus, proximity between the dental root apexes and the mandibular canal, and the presence of radiographic signs of proximity to the mandibular canal. In addition, when there was a distance between the root apexes and the mandibular canal, it was measured. As a reference, these same parameters were assessed in the CBCT scans by a fourth examiner. For the statistical analysis, the weighted Kappa, Bland Altman, and Wilcoxon tests were performed (α = 0.05). RESULTS: The agreement between the assessments performed in the panoramic modalities with the CBCT ranged from 66.1% to 100.0% for the categorical variables. Overall, the agreement values of CPAN and MPAN with CBCT were similar. The distances between the dental root apex and the mandibular canal for both CPAN and MPAN were significantly underestimated compared to CBCT (p < 0.05). The intra- and interexaminer agreements of the examiners ranged from poor to almost perfect; in general, the agreements were higher in the evaluation performed in the MPAN than in the CPAN. CONCLUSIONS: The MPAN performs similarly to CPAN for evaluating mandibular third molars and their proximity relationship to the mandibular canal. CLINICAL RELEVANCE: Preoperative evaluation of lower mandibular third molars is usually performed using CPAN. Recently, a new tool, MPAN, was developed, which has not yet been tested for the evaluation of mandibular third molars and showed similar performance to CPAN in the present study. Future studies using MPAN are encouraged to evaluate other diagnostic tasks.


Asunto(s)
Tercer Molar , Diente Impactado , Humanos , Tercer Molar/cirugía , Radiografía Panorámica/métodos , Diente Molar , Mandíbula , Tomografía Computarizada de Haz Cónico/métodos
10.
Braz. dent. j ; 34(4): 150-157, July-Aug. 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO | ID: biblio-1520332

RESUMEN

Abstract This study aimed to assess the influence of the file format on the image quality parameters (image noise, brightness, and uniformity) of periapical radiographs acquired with different digital systems. Radiographic images of an acrylic phantom were acquired with two digital systems - Digora Toto and Express, and exported into five different file formats - TIFF, BMP, DICOM, PNG, and JPEG. Image noise, image brightness (mean of gray values), and image uniformity (standard deviation of gray values) were evaluated in all images. A two-way analysis of variance with Tukey's test as a post-hoc test was used to compare the results, considering the file formats and radiographic systems as the studied factors. A significance level of 5% was adopted for all analyses. The DICOM image file format presented lower image noise, higher brightness (higher mean gray values), and greater image uniformity (p<0.001) than the other file formats, which did not differ from each other for both digital radiography systems (p>0.05). The Express system revealed lower image noise and greater image uniformity than the Digora Toto system regardless of the image file format (p<0.001). Moreover, the Express showed higher brightness than the Digora Toto for all image file formats (p<0.001), except for the DICOM image file format, which did not significantly differ between the digital radiography systems tested (p>0.05). The DICOM image file format showed lower image noise, higher brightness, and greater image uniformity than the other file formats (TIFF, BMP, PNG, and JPEG) in both digital radiography systems tested.


Resumo Este estudo teve como objetivo avaliar a influência do formato do arquivo nos parâmetros de qualidade de imagem (ruído de imagem, brilho e uniformidade) de radiografias periapicais adquiridas com diferentes sistemas digitais. As imagens radiográficas de um fantoma de acrílico foram adquiridas com dois sistemas digitais - Digora Toto e Express, e exportadas em cinco formatos de arquivo diferentes - TIFF, BMP, DICOM, PNG e JPEG. O ruído da imagem, o brilho da imagem (média dos valores de cinza) e a uniformidade da imagem (desvio padrão dos valores de cinza) foram avaliados em todas as imagens. A análise de variância (ANOVA) bidirecional com o teste post-hoc de Tukey foi aplicada para comparar os resultados, considerando os formatos de arquivo e os sistemas radiográficos como os fatores estudados. Um nível de significância de 5% foi adotado para todas as análises. O formato de arquivo de imagem DICOM apresentou menor ruído de imagem, maior brilho (maiores valores médios de cinza) e maior uniformidade de imagem (p<0,001) do que os outros formatos de arquivo, que não diferiram entre si para ambos os sistemas de radiografia digital (p>0,05). O sistema Express apresentou menor ruído de imagem e maior uniformidade de imagem que o sistema Digora Toto, independentemente do formato do arquivo de imagem (p<0,001). Além disso, o Express mostrou maior brilho do que o Digora Toto para todos os formatos de arquivo de imagem (p<0,001), exceto para o formato de arquivo de imagem DICOM, que não diferiu significativamente entre os sistemas de radiografia digital testados (p>0,05). O formato de arquivo de imagem DICOM mostrou menor ruído de imagem, maior brilho e maior uniformidade de imagem do que os outros formatos de arquivo (TIFF, BMP, PNG e JPEG) em ambos os sistemas de radiografia digital testados.

11.
Dentomaxillofac Radiol ; 52(7): 20230147, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37493606

RESUMEN

OBJECTIVE: To compare cylindrical and convex triangular field-of-views (FOVs) concerning the magnitude of artefacts from high-density materials in cone-beam CT (CBCT). METHODS AND MATERIALS: Cylinders of amalgam, chromium-cobalt, titanium, and zirconia were individually placed in the anterior and posterior regions of a polymethylmethacrylate phantom and scanned using cylindrical and convex triangular FOVs of the Veraview X800 CBCT device. Using the Image J software, 15 square regions of interest (ROIs) were placed in the axial reconstruction around the middle level of the cylinder and at distances of 0.5, 1.0, and 1.5 cm from the centre of the cylinder. Mean grey value and standard deviation of each ROI were averaged for each distance and subtracted from the values of a control ROI to calculate the magnitude of the artefacts by the grey value mean difference (GVMD) and grey value standard deviation (GVSD). Multiway analysis of variance with Tukey post-hoc test with a significance level of 5% evaluated the effect of the shape of the FOV, position inside the FOV, high-density material, and the distance of the artefact from the material. RESULTS: The convex triangular FOV increased the GVSD for all materials in the anterior and posterior regions at 0.5 cm compared to the cylindrical FOV (p < 0.0001). The convex triangular FOV showed greater GVMD for chromium-cobalt and zirconium in the anterior region and all materials in the posterior region at all distances (p < 0.0001). CONCLUSION: The FOV shape influences the magnitude of artefacts from high-density materials. The convex triangular FOV showed greater artefact magnitude with variability among the high-density materials, region in the FOV, and distance from the material.


Asunto(s)
Artefactos , Tomografía Computarizada de Haz Cónico , Humanos , Cobalto , Cromo , Fantasmas de Imagen
12.
Artículo en Inglés | MEDLINE | ID: mdl-37468380

RESUMEN

OBJECTIVE: This study evaluated changes in image quality and the presence and size of artifacts on radiographs obtained with photostimulable phosphor (PSP) plates after disinfection with 70% ethyl alcohol and 70% isopropyl alcohol. STUDY DESIGN: Eight PSP receptors (4 Express and 4 VistaScan) were used for the investigation. Two Express and 2 VistaScan receptors were disinfected with 70% ethyl alcohol, and 2 Express and 2 VistaScan receptors were disinfected with 70% isopropyl alcohol. Before disinfection and after every 5 disinfections, 2 radiographs of an aluminum stepwedge and 2 radiographs of an acrylic block were acquired using each receptor. The gray values of the radiographs were analyzed regarding contrast, density, uniformity, and noise. Four oral radiologists evaluated the images for the presence of artifacts, and 2 measured the artifacts. RESULTS: Differences in image contrast were significantly larger with isopropyl alcohol (P < .0001). Artifact size was significantly greater with the VistaScan system when isopropyl alcohol was used as the disinfectant (P < .0001). The correlation between the number of disinfections and artifact size was moderately positive with the Express system (P < .05) and strongly positive with the VistaScan system (P < .05) with both disinfectants. CONCLUSIONS: Small artifacts restricted to the edges of the image were observed with disinfection using both types of alcohol, and a positive correlation was found between artifact size and the number of disinfections. However, artifacts appeared earlier and of greater size with the VistaScan system when disinfected with 70% isopropyl alcohol. Thus, we recommend using 70% ethyl alcohol to disinfect PSP receptors, with attention placed on its action and evaporation times.


Asunto(s)
2-Propanol , Radiografía Dental Digital , Humanos , Radiografía Dental Digital/métodos , Desinfección/métodos , Artefactos , Intensificación de Imagen Radiográfica/métodos , Etanol
13.
Sci Rep ; 13(1): 6266, 2023 04 17.
Artículo en Inglés | MEDLINE | ID: mdl-37069172

RESUMEN

Photon-counting computed tomography (PCCT) is an innovative technological advancement in relation to x-ray detectors which offers ultra-high-resolution images. The current study aimed to evaluate the visualization ability of PCCT compared to cone-beam computed tomographic (CBCT) devices for challenging endodontic diagnostic tasks. A reference image of an anthropomorphic phantom was acquired using an industrial micro-CT device. Thereafter, the phantom was scanned with three imaging devices, which included PCCT scanner (NAEOTOM Alpha) and two CBCT devices (3D Accuitomo 170 and NewTom VGi evo) having standard and high-resolution acquisition protocols. The diagnostic tasks involved visualizing fine endodontic structures (apical delta, narrow canal, and isthmus) and root cracks. Three experienced examiners assessed the images and were blinded to the PCCT and CBCT devices. Each image was rated according to a three-grade scale (appropriate, acceptable, or inappropriate) for the diagnostic tasks. In relation to fine endodontic structures grouped together, PCCT showed similar diagnostic performance compared to the reference image (p > 0.05). As for the CBCT devices, an excellent performance was only observed with the 3D Accuitomo 170 device at a high-resolution acquisition mode (p > 0.05). The visualization of root cracks was also better with 3D Accuitomo 170 compared to other devices (p < 0.05). Overall, PCCT and 3D Accuitomo 170 at a high-resolution setting showed similar performance for visualizing fine endodontic structures. In addition, the high-resolution CBCT protocol was superior for visualizing root cracks compared to both PCCT and other standard- and high-resolution CBCT protocols.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Tomografía Computarizada de Haz Cónico/métodos , Estudios de Factibilidad , Microtomografía por Rayos X , Fantasmas de Imagen
14.
Braz Dent J ; 34(1): 39-44, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36888843

RESUMEN

The study aimed to assess the influence of excessive use of a photostimulable phosphor plate (PSP) on the density, image noise, and contrast of radiographs. For that, radiographs of an acrylic block were acquired with a PSP of the Express intraoral system to assess the density and image noise. Initially, five images were obtained and exported (first group). After 400 exposures to X-rays and scannings of PSP, other five images were obtained and exported (second group). The same procedure was done after 800 (third group), 1200 (fourth group), 1600 (fifth group), and 2000 acquisitions (sixth group), resulting in 30 images to be evaluated. The mean and standard deviation of the gray values were calculated for the images using the ImageJ software. For contrast analysis, radiographs of an aluminum step-wedge were acquired with a new PSP following the same acquisition intervals. The percentage of contrast variation was calculated. Another two unused PSP receptors were employed to evaluate the method's reproducibility. The comparison of the results among the acquisition groups was performed with one-way Analysis of Variance (α=0.05). Intraclass Correlation Coefficient (ICC) assessed the reproducibility of the receptors. Image noise did not differ among the groups (p>0.05). There was a slight increase in density after 400 acquisitions and a slight difference in contrast for all acquisition groups without a pattern of increase or decrease (p<0.05). ICC showed excellent reliability for the methods. Therefore, excessive PSP use slightly affected the radiograph's density and contrast.


Asunto(s)
Radiografía Dental Digital , Radiografía Dental Digital/métodos , Reproducibilidad de los Resultados
15.
Clin Oral Implants Res ; 34(6): 565-574, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36906917

RESUMEN

OBJECTIVES: To develop and assess the performance of a novel artificial intelligence (AI)-driven convolutional neural network (CNN)-based tool for automated three-dimensional (3D) maxillary alveolar bone segmentation on cone-beam computed tomography (CBCT) images. MATERIALS AND METHODS: A total of 141 CBCT scans were collected for performing training (n = 99), validation (n = 12), and testing (n = 30) of the CNN model for automated segmentation of the maxillary alveolar bone and its crestal contour. Following automated segmentation, the 3D models with under- or overestimated segmentations were refined by an expert for generating a refined-AI (R-AI) segmentation. The overall performance of CNN model was assessed. Also, 30% of the testing sample was randomly selected and manually segmented to compare the accuracy of AI and manual segmentation. Additionally, the time required to generate a 3D model was recorded in seconds (s). RESULTS: The accuracy metrics of automated segmentation showed an excellent range of values for all accuracy metrics. However, the manual method (95% HD: 0.20 ± 0.05 mm; IoU: 95% ± 3.0; DSC: 97% ± 2.0) showed slightly better performance than the AI segmentation (95% HD: 0.27 ± 0.03 mm; IoU: 92% ± 1.0; DSC: 96% ± 1.0). There was a statistically significant difference of the time-consumed among the segmentation methods (p < .001). The AI-driven segmentation (51.5 ± 10.9 s) was 116 times faster than the manual segmentation (5973.3 ± 623.6 s). The R-AI method showed intermediate time-consumed (1666.7 ± 588.5 s). CONCLUSION: Although the manual segmentation showed slightly better performance, the novel CNN-based tool also provided a highly accurate segmentation of the maxillary alveolar bone and its crestal contour consuming 116 times less than the manual approach.


Asunto(s)
Inteligencia Artificial , Procesamiento de Imagen Asistido por Computador , Procesamiento de Imagen Asistido por Computador/métodos , Redes Neurales de la Computación , Tomografía Computarizada de Haz Cónico/métodos
16.
Braz. dent. j ; 34(1): 39-44, Jan.-Feb. 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO | ID: biblio-1420574

RESUMEN

Abstract The study aimed to assess the influence of excessive use of a photostimulable phosphor plate (PSP) on the density, image noise, and contrast of radiographs. For that, radiographs of an acrylic block were acquired with a PSP of the Express intraoral system to assess the density and image noise. Initially, five images were obtained and exported (first group). After 400 exposures to X-rays and scannings of PSP, other five images were obtained and exported (second group). The same procedure was done after 800 (third group), 1200 (fourth group), 1600 (fifth group), and 2000 acquisitions (sixth group), resulting in 30 images to be evaluated. The mean and standard deviation of the gray values were calculated for the images using the ImageJ software. For contrast analysis, radiographs of an aluminum step-wedge were acquired with a new PSP following the same acquisition intervals. The percentage of contrast variation was calculated. Another two unused PSP receptors were employed to evaluate the method's reproducibility. The comparison of the results among the acquisition groups was performed with one-way Analysis of Variance (α=0.05). Intraclass Correlation Coefficient (ICC) assessed the reproducibility of the receptors. Image noise did not differ among the groups (p>0.05). There was a slight increase in density after 400 acquisitions and a slight difference in contrast for all acquisition groups without a pattern of increase or decrease (p<0.05). ICC showed excellent reliability for the methods. Therefore, excessive PSP use slightly affected the radiograph's density and contrast.


Resumo Objetivou-se avaliar a influência do uso excessivo de uma placa de fósforo fotoestimulável (PSP) na densidade, ruído e contraste das radiografias. Foram adquiridas radiografias de um bloco de acrílico com uma PSP do sistema intraoral Express para avaliar a densidade e o ruído da imagem. Inicialmente, cinco imagens foram obtidas e exportadas (primeiro grupo). Após 400 exposições aos raios X e escaneamentos, outras cinco imagens foram obtidas e exportadas (segundo grupo). O mesmo procedimento foi feito após 800 (terceiro grupo), 1200 (quarto grupo), 1600 (quinto grupo) e 2000 aquisições (sexto grupo), resultando em 30 imagens a serem avaliadas. A média e o desvio padrão dos valores de cinza foram calculados para as imagens usando o software ImageJ. Para análise de contraste, foram adquiridas radiografias de uma escala de alumínio com uma nova PSP seguindo os mesmos intervalos de aquisição. A porcentagem de variação do contraste foi calculada. Outras duas PSP sem uso prévio foram utilizadas para avaliar a reprodutibilidade dos métodos. A comparação dos resultados entre os grupos de aquisição foi realizada pela Análise de Variância one-way (α=0,05). O Coeficiente de Correlação Intraclasse (ICC) avaliou a reprodutibilidade dos receptores. O ruído da imagem não diferiu entre os grupos (p>0,05). Houve um leve aumento na densidade após 400 aquisições e uma pequena diferença no contraste para todos os grupos de aquisição sem padrão de aumento ou diminuição (p<0,05). O ICC mostrou excelente confiabilidade para os métodos. Portanto, o uso excessivo da PSP afetou levemente a densidade e o contraste radiográfico.

17.
Artículo en Inglés | MEDLINE | ID: mdl-36566136

RESUMEN

OBJECTIVE: The aim of this study was to evaluate the influence of the extensive use of a photostimulable phosphor (PSP) receptor on the diagnosis of proximal carious lesions. STUDY DESIGN: Forty posterior teeth were paired and mounted in 20 phantoms. Using a PSP receptor of the Express intraoral system, 1 radiograph of each phantom was acquired, totaling 20 radiographs (group 1). After 400 acquisitions, another radiograph of each phantom was obtained, totaling 20 new radiographs (group 2). This procedure was also done after 800 (group 3), 1,200 (group 4), and 1,600 (group 5) acquisitions, resulting in 100 radiographs. Another 40 radiographs (20 phantoms × 2 groups) were obtained with a second PSP sensor to evaluate the diagnostic replicability of the receptors. All 140 radiographs were assessed independently by 5 examiners for the presence of proximal caries. Area under the receiver operating characteristic curve, sensitivity, and specificity were calculated and compared among the groups by analysis of variance. The Student t test evaluated the diagnostic replicability of the receptors. The significance level was set at 5% (P < .05). RESULTS: The diagnostic outcomes for proximal caries did not differ among the groups (P ≥ .37). The diagnostic values did not differ among the radiographs acquired with the 2 PSP receptors (P ≥ .75). CONCLUSIONS: The diagnosis of proximal carious lesions was not affected by extensive use of the PSP receptor.


Asunto(s)
Caries Dental , Radiografía de Mordida Lateral , Humanos , Caries Dental/diagnóstico por imagen , Diente Molar/diagnóstico por imagen , Diente Molar/patología , Sensibilidad y Especificidad
18.
Oral Maxillofac Surg ; 27(1): 17-23, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35304654

RESUMEN

PURPOSE: The aim of this study was to evaluate the morphology and topography of the mandibular canal in patients with different facial profiles, skeletal classes, and sexes. METHODS: Cone-beam computed tomography volumes of 103 patients were classified according to facial profile and skeletal class. Two examiners classified the mandibular canal into a linear, spoon-shaped, elliptical arc, or turning curvature and measured four related linear distances. The most frequent mandibular canal curvature was identified and multi-way ANOVA with Tukey's test compared the linear measurements between facial types, skeletal class, and sexes (α = 0.05). Kappa and intraclass correlation coefficients were used to assess the reproducibility of qualitative and quantitative variables, respectively. RESULTS: The examiners showed excellent reproducibility. The four curvatures of the mandibular canal were found, but the spoon-shaped and elliptical arch were the most frequent. No significant differences were observed for most of the linear measurements between the different facial profiles, skeletal classes, and sexes (p > 0.05). CONCLUSION: Spoon-shaped and elliptical arch are the most frequent curvatures of the mandibular canal; furthermore, its morphology and topography seem to be little influenced by the facial profile, skeletal class, and sex.


Asunto(s)
Mandíbula , Canal Mandibular , Humanos , Mandíbula/anatomía & histología , Reproducibilidad de los Resultados , Tomografía Computarizada de Haz Cónico/métodos , Cara
19.
J Prosthet Dent ; 129(5): 741-747, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-34399992

RESUMEN

STATEMENT OF PROBLEM: Knowledge about the location and dimensions of the mental foramen is important for surgical planning and implant placement in the posterior mandibular region. PURPOSE: The purpose of this clinical study was to assess the location and dimensions of the mental foramen in individuals of different facial type, skeletal class, and sex by means of cone beam computed tomography (CBCT) images. MATERIAL AND METHODS: CBCT images of 142 individuals (72 women and 70 men) were classified according to the facial type (dolichocephalic, mesocephalic, or brachycephalic) and skeletal class (I, II, or III). The vertical and horizontal locations of each mental foramen were evaluated on panoramic reconstructions, and the greatest height and width of the mental foramen were determined on multiplanar reconstructions. Also, the distances from the mental foramen to the alveolar crest and to the inferior cortex of the mandible were obtained. The data were compared by using the Kruskal-Wallis test and multiway analysis of variance (α=.05). RESULTS: The facial type, skeletal class, and sex did not influence the vertical (P=1.00) or the horizontal (P>.15) location of the mental foramen. The most frequent location of the mental foramen was between the first and second premolars and below their apices. The dimensions of the mental foramen were not influenced by the studied factors in men (P>.07); conversely, the mental foramen dimensions were influenced for women (P<.03). CONCLUSIONS: The most frequent location of the mental foramen was between the first and second premolars and below their apices. An influence of the facial type and skeletal class was observed on the dimensions of the mental foramen in women.


Asunto(s)
Foramen Mental , Tomografía Computarizada de Haz Cónico Espiral , Masculino , Humanos , Femenino , Mandíbula/diagnóstico por imagen , Cara/diagnóstico por imagen , Proceso Alveolar/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico/métodos
20.
J Dent ; 139: 104765, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-38353315

RESUMEN

OBJECTIVE: To compare a three-dimensional (3D) artificial intelligence (AI)- driven model with panoramic radiography (PANO) and cone-beam computed tomography (CBCT) in assessing the risk of inferior alveolar nerve (IAN) injury after mandibular wisdom tooth (M3M) removal through a within-patient controlled trial. METHODS: From a database of 6,010 patients undergoing M3M surgery, 25 patients met the inclusion criteria of bilateral M3M removal with postoperative unilateral IAN injury. In this within-patient controlled trial, preoperative PANO and CBCT images were available, while 3D-AI models of the mandibular canal and teeth were generated from the CBCT images using the Virtual Patient Creator AI platform (Relu BV, Leuven, Belgium). Five examiners, who were blinded to surgical outcomes, assessed the imaging modalities and assigned scores indicating the risk level of IAN injury (high, medium, or low risk). Sensitivity, specificity, and area under receiver operating curve (AUC) for IAN risk assessment were calculated for each imaging modality. RESULTS: For IAN injury risk assessment after M3M removal, sensitivity was 0.87 for 3D-AI, 0.89 for CBCT versus 0.73 for PANO. Furthermore, the AUC and specificity values were 0.63 and 0.39 for 3D-AI, 0.58 and 0.28 for CBCT, and 0.57 and 0.41 for PANO, respectively. There was no statistically significant difference (p>0.05) among the imaging modalities for any diagnostic parameters. CONCLUSION: This within-patient controlled trial study revealed that risk assessment for IAN injury after M3M removal was rather similar for 3D-AI, PANO, and CBCT, with a sensitivity for injury prediction reaching up to 0.87 for 3D-AI and 0.89 for CBCT. CLINICAL SIGNIFICANCE: This within-patient trial is pioneering in exploring the application of 3D AI-driven models for assessing IAN injury risk after M3M removal. The present results indicate that AI-powered 3D models based on CBCT might facilitate IAN risk assessment of M3M removal.


Asunto(s)
Tercer Molar , Extracción Dental , Traumatismos del Nervio Trigémino , Humanos , Inteligencia Artificial , Tomografía Computarizada de Haz Cónico/métodos , Mandíbula/diagnóstico por imagen , Mandíbula/cirugía , Nervio Mandibular/diagnóstico por imagen , Tercer Molar/diagnóstico por imagen , Tercer Molar/cirugía , Radiografía Panorámica/métodos , Medición de Riesgo , Extracción Dental/efectos adversos , Traumatismos del Nervio Trigémino/etiología
SELECCIÓN DE REFERENCIAS