Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 99
Filtrar
1.
J Arrhythm ; 40(3): 552-559, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38939776

RESUMEN

Background: Atrioventricular nodal reentrant tachycardia (AVNRT) sometimes recurs even after anatomical slow pathway (SP) ablation targeting the rightward inferior extension (RIE). This multicenter study aimed to determine the reasons for AVNRT recurrence. Methods and Results: Forty-six patients were treated successfully for recurrent AVNRT. Initial treatment was for 38 slow-fast AVNRTs, 3 fast-slow AVNRTs, 2 slow-slow AVNRTs, 2 slow-fast and fast-slow AVNRTs, and 1 noninducible AVNRT. All initial treatments were of RF application to the RIE; SP elimination was achieved in 11, dual AVN physiology was seen in 29, and AVNRT remained inducible in 5. The recurrent AVNRTs included 34 slow-fast AVNRTs, 6 fast-slow AVNRTs, 3 slow-slow AVNRTs, 2 slow-fast and fast-slow AVNRTs, and 1 slow-fast and slow-slow AVNRTs. Successful ablation site was within the RIE in 39 and left inferior extension in 7. In 30 of 39, the successful RIE site was in the same area or higher than that of the initial procedure. Conclusion: For a high majority (around 85%) of patients in whom AVNRT recurs after initial ablation success, the site of a second successful procedure will be within the RIE even though the RIE was originally targeted. Furthermore, a high majority (around 86%) of sites of successful ablation will be higher than those originally targeted.

2.
J Arrhythm ; 40(3): 423-433, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38939793

RESUMEN

Background: Despite the positive impact of implantable cardioverter defibrillators (ICDs) and wearable cardioverter defibrillators (WCDs) on prognosis, their implantation is often withheld especially in Japanese heart failure patients with reduced left ventricular ejection fraction (HFrEF) who have not experienced ventricular tachycardia (VT) or ventricular fibrillation (VF) for uncertain reasons. Recent advancements in heart failure (HF) medications have significantly improved the prognosis for HFrEF. Given this context, a critical reassessment of the treatment and prognosis of ICDs and WCDs is essential, as it has the potential to reshape awareness and treatment strategies for these patients. Methods: We are initiating a prospective multicenter observational study for HFrEF patients eligible for ICD in primary and secondary prevention, and WCD, regardless of device use, including all consenting patients. Study subjects are to be enrolled from 31 participant hospitals located throughout Japan from April 1, 2023, to December 31, 2024, and each will be followed up for 1 year or more. The planned sample size is 651 cases. The primary endpoint is the rate of cardiac implantable electronic device implementation. Other endpoints include the incidence of VT/VF and sudden death, all-cause mortality, and HF hospitalization, other events. We will collect clinical background information plus each patient's symptoms, Clinical Frailty Scale score, laboratory test results, echocardiographic and electrocardiographic parameters, and serial changes will also be secondary endpoints. Results: Not applicable. Conclusion: This study offers invaluable insights into understanding the role of ICD/WCD in Japanese HF patients in the new era of HF medication.

3.
Heart Rhythm ; 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38759918

RESUMEN

BACKGROUND: Novel diamond-embedded catheter enables precise temperature-controlled ablation. However, the effects of contact angle on lesion formation of this catheter are poorly understood. OBJECTIVE: The purpose of this study was to evaluate lesion formation using the temperature-controlled ablation catheter embedded with diamond at different angles in a porcine experimental model. METHODS: Freshly sacrificed porcine hearts were used. Radiofrequency catheter ablation was performed at 50 W for 15 seconds at an upper temperature setting of 60°C. The contact force (5g, 10g, 30g) and catheter contact angles (30°, 45°, 90°) were changed in each set (n = 13 each). Surface width, maximum lesion width, lesion depth, surface area, distance from the distal edge to the widest area, and impedance drop were evaluated. RESULTS: Surface width and maximum lesion width were longer at 30° than at 90° (P <.05). There were no significant differences in the lesion depth by catheter angle except at 30g. Surface area was larger at 30° than at 90° (P <.05). Distance from the distal edge to the widest area was longer at 30° than at 90° (P <.05). There were no significant differences in impedance drop according to catheter angle. CONCLUSION: With diamond-embedded temperature-controlled ablation catheters, lesion width increased at a shallower contact angle, whereas lesion depth did not. Surface area also increased at a shallower contact angle. This catheter created a large ablation lesion on the proximal side of the catheter, which looked like a "honey pot."

4.
J Arrhythm ; 40(2): 297-305, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38586850

RESUMEN

Background: The prognostic impact of atrial fibrillation (AF) and oral anticoagulation (OAC) therapy in patients with type B acute aortic dissection (AAD) remains unclear. Therefore, we investigated the prognostic impact of AF and OAC therapy in patients with type B AAD. Methods: Consecutive patients diagnosed with AAD were included in this single-center, retrospective study. Patients with type B AAD were selected from the study population and divided into three groups: AF(+)/OAC(+), AF(+)/OAC(-), and AF(-)/OAC(-). The primary end point was major adverse cardiovascular and cerebrovascular events (MACCE), including all-cause death, progressive aortic events, cerebral infarction, and organ malperfusion. Results: In total, 139 patients diagnosed with type B AAD were analyzed. AF was observed in 27 patients (19%). Among them, 13 patients (9%) received OAC therapy for AF. MACCE occurred in 32 patients (23%) during the observation period: all-cause death in four patients, progressive aortic events in 24 patients, cerebral infarction events in two patients, and malperfusion events in two patients. The incidence of MACCE was higher in the AF(+)/OAC(+) group than in the AF(+)/OAC(-) group (hazard ratio[HR]: 3.875; 95% confidence interval [CI]: 1.153-17.496). In contrast, there was no significant difference in the incidence of MACCE between the AF(+)/OAC(-) and AF(-)/OAC(-) groups (HR: 1.001, 95% CI: 0.509-1.802). Conclusion: Among patients with type B AAD, the use of OAC for AF was associated with a higher risk of MACCE.

5.
J Arrhythm ; 40(1): 131-142, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38333409

RESUMEN

Background: This study aimed to establish a systematic method for diagnosing atrioventricular nodal reentrant tachycardia (AVNRT) with a bystander concealed nodoventricular pathway (cNVP). Methods: We analyzed 13 cases of AVNRT with a bystander cNVP, 11 connected to the slow pathway (cNVP-SP) and two to the fast pathway (cNVP-FP), along with two cases of cNVP-related orthodromic reciprocating tachycardia (ORT). Results: The diagnostic process was summarized in three steps. Step 1 was identification of the presence of an accessory pathway by resetting the tachycardia with delay (n = 9) and termination without atrial capture (n = 4) immediately after delivery of a His-refractory premature ventricular contraction (PVC). Step 2 was exclusion of ORT by atrio-His block during the tachycardia (n = 4), disappearance of the reset phenomenon after the early PVC (n = 7), or dissociation of His from the tachycardia during ventricular overdrive pacing (n = 1). Moreover, tachycardia reset/termination without the atrial capture (n = 2/2) 1 cycle after the His-refractory PVC was specifically diagnostic. Exceptionally, the disappearance of the reset phenomenon was also observed in the two cNVP-ORTs. Step 3 was verification of the AVN as the cNVP insertion site, evidenced by an atrial reset/block preceding the His reset/block in fast-slow AVNRT with a cNVP-SP and slow-fast AVNRT with a cNVP-FP or His reset preceding the atrial reset in slow-fast AVNRT with a cNVP-SP. Conclusion: AVNRT with a bystander cNVP can be diagnosed in the three steps with few exceptions. Notably, tachycardia reset/termination without atrial capture one cycle after delivery of a His-refractory PVC is specifically diagnostic.

7.
Front Cardiovasc Med ; 10: 1278603, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37965084

RESUMEN

Background: Symptomatic gastric hypomotility (SGH) is a rare but major complication of atrial fibrillation (AF) ablation, but data on this are scarce. Objective: We compared the clinical course of SGH occurring with different energy sources. Methods: This multicenter study retrospectively collected the characteristics and clinical outcomes of patients with SGH after AF ablation. Results: The data of 93 patients (67.0 ± 11.2 years, 68 men, 52 paroxysmal AF) with SGH after AF ablation were collected from 23 cardiovascular centers. Left atrial (LA) ablation sets included pulmonary vein isolation (PVI) alone, a PVI plus a roof-line, and an LA posterior wall isolation in 42 (45.2%), 11 (11.8%), and 40 (43.0%) patients, respectively. LA ablation was performed by radiofrequency ablation, cryoballoon ablation, or both in 38 (40.8%), 38 (40.8%), and 17 (18.3%) patients, respectively. SGH diagnoses were confirmed at 2 (1-4) days post-procedure, and 28 (30.1%) patients required re-hospitalizations. Fasting was required in 81 (92.0%) patients for 4 (2.5-5) days; the total hospitalization duration was 11 [7-19.8] days. After conservative treatment, symptoms disappeared in 22.3% of patients at 1 month, 48.9% at 2 months, 57.6% at 3 months, 84.6% at 6 months, and 89.7% at 12 months, however, one patient required surgery after radiofrequency ablation. Symptoms persisted for >1-year post-procedure in 7 patients. The outcomes were similar regardless of the energy source and LA lesion set. Conclusions: The clinical course of SGH was similar regardless of the energy source. The diagnosis was often delayed, and most recovered within 6 months, yet could persist for over 1 year in 10%.

8.
J Arrhythm ; 39(3): 480-482, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37324762

RESUMEN

We report an adult case with JT, which could be differentiated from slow-fast AVNRT by premature atrial contractions and atrial overdrive pacing.

10.
J Cardiol ; 82(1): 76-83, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36935004

RESUMEN

BACKGROUND: A novel Diamond Temp™ (DT; Medtronic, Minneapolis, MN, USA) catheter has enabled performing a surface temperature-controlled ablation. The chemical vapor deposition diamond of the ablation catheter acts as a thermal radiator and is useful for effective cooling of the ablation catheter tip. However, a detailed analysis of the lesion formation with this catheter remains unknown. METHODS: DT catheters were used in an excised swine heart experimental model. A cross-sectional analysis of 60-s lesions [a combination of various energy power settings (30, 40, and 50 W), and various contact forces (CF) (10, 30, and 50 g)] and a longitudinal analysis [a combination of various powers (40 W or 50 W), various CFs (10, 30, and 50 g), and various ablation times (5 s, 10 s, 15 s, 20 s, 25 s, 30 s, and 60 s)] of the DT catheter were analyzed. RESULTS: The maximum lesion depth, maximum diameter, and lesion volume with a 10 g ablation were significantly lower than those with a 30 g or 50 g ablation. There were no significant differences in the lesion formation between the 30 g ablation and 50 g ablation under each radiofrequency (RF) power setting. The impedance drops with steam pops were significantly greater than those without steam pops (pop (+) vs. pop (-), 26.2 ±â€¯6.6 Ohm vs. 18.4 ±â€¯7.1 Ohm, p = 0.0001). A non-linear, time-dependent increase in the lesion depth and diameter was observed for all power and CF settings. Comparing the lesion depth and diameter between 40 W and 50 W under the same CF setting and same ablation time, most of the settings had no significant difference. CONCLUSION: Ablation lesions created with the DT catheter were similar to other catheters. Similar ablation lesions were created with the 40 W or 50 W ablation under the same CF setting and same ablation time. Regardless of the ablation power, monitoring the general impedance during the RF application was indispensable for a safe procedure.


Asunto(s)
Ablación por Catéter , Vapor , Animales , Porcinos , Estudios Transversales , Catéteres , Corazón , Ventrículos Cardíacos/patología , Ablación por Catéter/métodos , Diseño de Equipo
12.
BMJ Open ; 13(2): e068894, 2023 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-36792334

RESUMEN

INTRODUCTION: Data are lacking on the extent to which patients with non-valvular atrial fibrillation (AF) who are aged ≥80 years benefit from ablation treatment. The question pertains especially to patients' postablation quality of life (QoL) and long-term clinical outcomes. METHODS AND ANALYSIS: We are initiating a prospective, registry-based, multicentre observational study that will include patients aged ≥80 years with non-valvular AF who choose to undergo treatment by catheter ablation and, for comparison, such patients who do not choose to undergo ablation (either according to their physician's advice or their own preference). Study subjects are to be enrolled from 52 participant hospitals and three clinics located throughout Japan from 1 June 2022 to 31 December 2023, and each will be followed up for 1 year. The planned sample size is 660, comprising 220 ablation group patients and 440 non-ablation group patients. The primary endpoint will be the composite incidence of stroke/transient ischaemic attack (TIA) or systemic embolism (SE), another cardiovascular event, major bleeding and/or death from any cause. Other clinical events such as postablation AF recurrence, a fall or bone fracture will be recorded. We will collect standard clinical background information plus each patient's Clinical Frailty Scale score, AF-related symptoms, QoL (Five-Level Version of EQ-5D) scores, Mini-Mental State Examination (optional) score and laboratory test results, including measures of nutritional status, on entry into the study and 1 year later, and serial changes in symptoms and QoL will also be secondary endpoints. Propensity score matching will be performed to account for covariates that could affect study results. ETHICS AND DISSEMINATION: The study conforms to the Declaration of Helsinki and the Ethical Guidelines for Clinical Studies issued by the Ministry of Health, Labour and Welfare, Japan. Results of the study will be published in one or more peer-reviewed journals. TRIAL REGISTRATION NUMBER: UMIN000047023.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Accidente Cerebrovascular , Anciano , Humanos , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Calidad de Vida , Estudios Prospectivos , Esperanza de Vida Saludable , Factores de Riesgo , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/complicaciones , Sistema de Registros , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Resultado del Tratamiento
13.
Circ J ; 87(7): 939-946, 2023 06 23.
Artículo en Inglés | MEDLINE | ID: mdl-36464278

RESUMEN

BACKGROUND: A recent randomized trial demonstrated that catheter ablation for atrial fibrillation (AF) in patients with heart failure with reduced ejection fraction (EF) is associated with a reduction in death or heart failure. However, the effect of catheter ablation for AF in patients with heart failure with mid-range or preserved EF is unclear.Methods and Results: We screened 899 AF patients (72.4% male, mean age 68.4 years) with heart failure and left ventricular EF ≥40% from 2 Japanese multicenter AF registries: the Atrial Fibrillation registry to Follow the long-teRm Outcomes and use of aNTIcoagulants aftER Ablation (AF Frontier Ablation Registry) as the ablation group (525 patients who underwent ablation) and the Hokuriku-Plus AF Registry as the medical therapy group (374 patients who did not undergo ablation). Propensity score matching was performed in these 2 registries to yield 106 matched patient pairs. The primary endpoint was a composite of cardiovascular death and hospitalization for heart failure. At 24.6 months, the ablation group had a significantly lower incidence of the primary endpoint (hazard ratio 0.32; 95% confidence interval 0.13-0.70; P=0.004) than the medical therapy group. CONCLUSIONS: Compared with medical therapy, catheter ablation for AF in patients with heart failure and mid-range or preserved EF was associated with a significantly lower incidence of cardiovascular death or hospitalization for heart failure.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Insuficiencia Cardíaca , Humanos , Masculino , Anciano , Femenino , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Volumen Sistólico , Resultado del Tratamiento , Insuficiencia Cardíaca/terapia , Ablación por Catéter/efectos adversos , Sistema de Registros
14.
J Cardiovasc Electrophysiol ; 34(1): 71-81, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36378816

RESUMEN

INTRODUCTION: Local impedance (LI) parameters of IntellaNav STABLEPOINT for successful pulmonary vein isolation (PVI) of atrial fibrillation (AF) remain unclear. The purpose of this study was to seek LI data achieving successful PVI. METHODS: Consecutive AF patients who underwent catheter ablation with STABLEPOINT were prospectively enrolled in two centers. PVI was performed under a constant 35-or 40-watt power, 20-s duration, and >5-g contact force. The operators were blinded to the LI data. The characteristics of all ablation points with/without conduction gaps (Unsuccess or Success tags) after the first-attempt PVI were evaluated for the right/left PVs and anterior/posterior wall (RPV/LPV and AW/PW, respectively), and cutoff values of LI data were calculated for successful lesion formation. RESULTS: A total of 5257 ablation points in 102 patients (65 [58-72] years old, 65.7% male) were evaluated. The LI drop values were higher in the Success tags than Unsuccess tags on the LPV-AW and RPV-AW/PW (p < .001), except for the LPV-PW (p = .105). The %LI drop values (LI drop/initial LI) were higher for the Success tags in all areas (15.8 [12.2%-19.6%] vs. 11.6 [9.7%-15.6%] in LPV-AW: p < .001, 15.0 [11.5%-19.3%] vs. 11.4 [8.7%-17.3%] in LPV-PW: p = .035, 15.3 [11.5%-19.4%] vs. 9.9 [8.1%-13.7%] in RPV-AW: p < .001, and 13.3 [10.1%-17.4%] vs. 8.1 [6.3%-9.5%] in RPV-PW, p < .001). The LI drop and %LI drop cutoff values were 20.0 ohms and 11.6%, respectively. CONCLUSIONS: An insufficient LI drop with STABLEPOINT was associated with a gap formation during PVI, and the best cutoff values for the LI drop and %LI drop were 20.0 ohms and 11.6%, respectively.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , Impedancia Eléctrica , Resultado del Tratamiento , Frecuencia Cardíaca , Ablación por Catéter/efectos adversos , Recurrencia
15.
J Med Eng Technol ; 47(2): 141-146, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36426804

RESUMEN

The mechanical properties of the myocardium in the left ventricle and right atrium were estimated by simultaneously measuring the local impedance (LI) and contact force (CF) using an ablation catheter. Radiofrequency catheter ablation (RFCA) is a well-established arrhythmia treatment. Monitoring the RF power, CF and properties of myocardium during RFCA are necessary to estimate the effect of ablation. Indices, such as CF, lesion size index and ablation index, do not include the myocardium mechanical properties. Therefore, there is the risk of side effects, such as cardiac tamponade, by excessive catheter indentation into vulnerable areas. We propose the simultaneous measurement of LI and CF for estimating the myocardial mechanical properties to reduce the side effects. In this study, an in vitro experimental system was constructed to measure LI and CF via the catheter. The relationship between the porcine myocardial tissue thickness and CF-LI curve was investigated using the left ventricle and right atrium. Power function coefficients approximating the CF-LI curve increased with thicker left ventricle. The thickness of the myocardium can be estimated by simultaneously measuring LI and CF. Intraoperative measurement of the myocardial mechanical properties can be used to determine the ablation conditions at each site.


Asunto(s)
Arritmias Cardíacas , Ablación por Catéter , Porcinos , Animales , Impedancia Eléctrica , Ventrículos Cardíacos/cirugía , Ventrículos Cardíacos/patología , Catéteres , Ablación por Catéter/efectos adversos
16.
J Interv Card Electrophysiol ; 66(2): 485-492, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36074285

RESUMEN

BACKGROUND: The lesion size index (LSI) predicts radiofrequency (RF) ablation lesion size and is an established parameter for pulmonary vein isolation. However, the effectiveness and safety of LSI for cavotricuspid isthmus (CTI) linear ablation remain unclear. METHODS: This single-center retrospective study included 50 of patients (67 ± 10 years, 68% male) who underwent de novo CTI linear ablation between July 2020 and December 2020. The LSI target was set at 5.0 and 4.0 for the anterior 2/3 and posterior 1/3 segments, respectively. Acute procedural parameters of ablation were evaluated. RESULTS: Acute bidirectional CTI block was achieved in all patients with an RF application time of 4.0 min (3.1-5.0 min), RF application number of 15 ± 7, and length of CTI of 36.9 ± 9.3 mm. First-pass bidirectional conduction block of the CTI was achieved in 39/50 (78%) patients. No major complications were observed. The contact force (CF) per application was significantly lower in the gap tag group than in the non-gap tag group (7 g [7-8 g] vs. 10 g [7-12 g], P = 0.0284). CONCLUSIONS: LSI-guided CTI linear ablation is an effective and safe treatment approach. CF affects gap formation, even when the target LSI is the same.


Asunto(s)
Aleteo Atrial , Ablación por Catéter , Humanos , Masculino , Femenino , Aleteo Atrial/cirugía , Resultado del Tratamiento , Estudios Retrospectivos , Ablación por Catéter/efectos adversos , Válvula Tricúspide/cirugía
17.
J Arrhythm ; 38(6): 991-996, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36524028

RESUMEN

Background: Previous studies have identified noninvasive methods for predicting atrial fibrillation (AF) recurrence after catheter ablation (CA). We assessed the association between AF recurrence and atrial late potentials (ALPs), which were measured using P-wave signal-averaged electrocardiography (P-SAECG). Methods: Consecutive patients with paroxysmal AF who underwent their first CA at our institution between August 2015 and August 2019 were enrolled. P-SAECG was performed before CA. Two ALP parameters were evaluated: the root-mean-square voltage during the terminal 20 ms (RMS20) and the P-wave duration (PWD). Positive ALPs were defined as an RMS20 <2.2 µV and/or a PWD >115 ms. Patients were allocated to either the recurrence or nonrecurrence group based on the presence of AF recurrence at the 1-year follow-up post-CA. Results: Of the 190 patients (age: 65 ± 11 years, 37% women) enrolled in this study, 21 (11%) had AF recurrence. The positive ALP rate was significantly higher in the recurrence group than in the nonrecurrence group (86% vs. 64%, p = .04), despite the absence of differences in other baseline characteristics between the two groups. In the multivariate analysis, positive ALP was an independent predictor of AF recurrence (odds ratio: 3.83, 95% confidence interval: 1.05-14.1, p = .04). Conclusions: Positive ALP on pre-CA P-SAECG is associated with AF recurrence after CA.

18.
J Arrhythm ; 38(6): 1080-1087, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36524038

RESUMEN

Background: The local impedance (LI) is an emerging technology that monitors tissue-catheter coupling during radiofrequency (RF) ablation. The relationships between the LI, RF delivery time, and lesion formation remain unclear. Methods: Using an LI-enabled RF catheter in an ex vivo experimental model, RF lesions were created combined with various steps in the power (40 and 50 W), CF (10 g, 30 g, and 50 g), and time (10s, 20s, 30s, 40s, 50s, and 60s at 40 W and 5 s, 10s, 20s, 30s, 40s, 50s, and 60s at 50 W). The correlations between the LI drop, lesion size, and RF delivery time were evaluated. The rate of change in the time-dependent gain in the LI, depth, and diameter and the time to reach 90% decay of the peak dY/dT (time to 90% decay) were assessed. Results: The correlation between the LI drop and ablation time revealed non-linear changes. The time to a 90% decay in the LI drop differed depending on the RF ablation setting and was always shorter with the 50 W setting than 40 W setting. The LI drop always correlated with the lesion formation under all ablation power settings. Deeper or wider lesions were predominantly created within the time to 90% decay of the LI drop. Conclusion: The LI drop was useful for predicting lesion sizes. Deeper or wider lesions cannot be obtained with a longer ablation than the 90% decay time of the LI drop. A shorter ablation than the 90% decay time of the LI drop would be preferable for an effective ablation.

19.
J Cardiol Cases ; 26(5): 371-374, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36312773

RESUMEN

A 48-year-old male with ischemic cardiomyopathy was admitted because of cardiogenic shock due to incessant ventricular tachycardia (VT). Despite the introduction of multiple mechanical cardiac support (MCS) devices, his hemodynamics were unstable; therefore, VT ablation was performed. Due to the limited vascular and left ventricle (LV) access with the multiple MCS devices, only the left femoral artery and vein were accessible. In addition, the transseptal approach as an LV access was difficult because of the MitraClip (Abbott Park, IL, USA). Posterior papillary muscle-origin VT was successfully treated via a transaortic approach under the MCS. After the VT ablation, the patient recovered from the MCS. Learning objective: Mechanical cardiac support (MCS) devices are critical during ventricular tachycardia (VT) ablation in patients with left ventricular (LV) dysfunction. However, the ablation strategy for cases with limited access due to multiple MCS devices has not been established. In this case, VT was successfully treated via a transaortic approach using intracardiac echocardiography. The number of cases requiring VT ablation for patients with limited vascular and LV endocardial access would increase; therefore, the accumulation of those cases is required to find a better strategy.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA