Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
ACS Sens ; 9(4): 1775-1784, 2024 04 26.
Artículo en Inglés | MEDLINE | ID: mdl-38591344

RESUMEN

Periprosthetic joint infections (PJIs) pose a significant challenge in orthopedic surgery, particularly total joint arthroplasty (TJA), due to the potential for implant failure and increased patient morbidity. Early and accurate detection of PJIs is crucial for timely intervention and better patient prognosis. Herein, we successfully screened a high-affinity aptamer targeting alpha-defensin complex human neutrophil protein 1-3 (HNP 1-3; potential PJI biomarkers in synovial fluid [SF]) for the first time using systematic evolution of ligands by exponential enrichment (SELEX) on an integrated microfluidic platform. The compact microfluidic device enabled efficient screening, with each round completed within <2 h, comprising five rounds of positive selection, two rounds of negative selection, and one round of competitive selection. A novel one-aptamer-one-antibody assay was further developed from the optimal aptamer screened, and it could accurately quantify HNP 1-3 in SF within 3 h with only ∼50 µL of SF. The assay demonstrated strong binding affinity and specificity for the target protein in SF. Thirteen PJI SF samples were accurately diagnosed and the assay was accurate over a wide dynamic range (0.32-100 mg/L). This study has showcased a rapid and accurate diagnostic tool for PJI detection, which should see widespread use in the clinic, holding promise for potential analytical applications in orthopedic surgery and improving patient care.


Asunto(s)
Aptámeros de Nucleótidos , Infecciones Relacionadas con Prótesis , Técnica SELEX de Producción de Aptámeros , Líquido Sinovial , alfa-Defensinas , alfa-Defensinas/análisis , Humanos , Infecciones Relacionadas con Prótesis/diagnóstico , Técnica SELEX de Producción de Aptámeros/métodos , Aptámeros de Nucleótidos/química , Líquido Sinovial/química , Dispositivos Laboratorio en un Chip , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos
2.
Anal Chem ; 95(19): 7693-7701, 2023 05 16.
Artículo en Inglés | MEDLINE | ID: mdl-37145768

RESUMEN

Post-arthroplasty periprosthetic joint infection (PJI) is a serious ailment that can be difficult to diagnose. Herein, we developed a novel integrated microfluidic system (IMS) capable of detecting two common PJI biomarkers, alpha defensin human neutrophil peptide 1 (HNP-1) and C-reactive protein (CRP), from synovial fluid (SF). A magnetic bead-based one-aptamer-one-antibody assay was carried out automatically within 45 min on a single chip for simultaneous detection of both biomarkers at concentration ranges of 0.01-50 (HNP-1) and 1-100 (CRP) mg/L. It is the first report for utilizing these two biomarkers as targets to establish the new one-aptamer-one-antibody assay to detect PJI on-chip, and the aptamers demonstrated high specificity to their SF targets. As 20 clinical samples were correctly diagnosed with our IMS (verified by a common gold standard kit), it could serve as a promising tool for PJI diagnostics.


Asunto(s)
Artritis Infecciosa , Infecciones Relacionadas con Prótesis , Humanos , Líquido Sinovial/química , Infecciones Relacionadas con Prótesis/diagnóstico , Microfluídica , Sensibilidad y Especificidad , Biomarcadores/metabolismo , Proteína C-Reactiva/análisis , Artritis Infecciosa/diagnóstico , Artritis Infecciosa/metabolismo
3.
Biosens Bioelectron ; 229: 115120, 2023 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-36963324

RESUMEN

The diagnosis of periprosthetic joint infection (PJI) remains a labor-intensive and challenging issue, with life-threatening complications associated with misdiagnoses. Superior diagnostic approaches are therefore urgently needed, and synovial biomarkers are gaining substantial attention in this capacity. A new aptamer-based sandwich assay was developed where the aptamer probes specific to one such biomarker, alpha-defensin human neutrophil protein 1 (HNP 1), was integrated herein into a new microfluidic platform. The magnetic beads coated with the primary aptamer probe were able to bind the target protein with high affinity and high specificity in synovial fluid and a fluorescent-labelled secondary aptamer were further used to quantify HNP 1 in a sandwich approach. Up to four clinical samples with low volume (∼50 µL each) in a much faster assay including detection within <60 min with 100% accuracy (with totally 13 clinical samples without the need of sample pretreatment) through the use of the aptamer-based sandwich assay were automatically detected on a single chip. The wide dynamic range of this compact device, 0.5-100 mg/L, highlights its utility for future PJI diagnostics in the clinic.


Asunto(s)
Artritis Infecciosa , Técnicas Biosensibles , alfa-Defensinas , Humanos , Microfluídica , Neutrófilos , Biomarcadores , Oligonucleótidos , Líquido Sinovial , Artritis Infecciosa/diagnóstico , Sensibilidad y Especificidad
4.
Anal Chim Acta ; 1281: 341879, 2023 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-38783735

RESUMEN

BACKGROUND: Total joint arthroplasty (TJA) has significantly improved the quality of life for millions suffering from end-stage arthritis. However, periprosthetic joint infections (PJI) remain a serious complication, necessitating extensive interventions and prolonged antimicrobial treatments. The aging population is expected to lead to a rise in TJA cases, subsequently increasing the incidence of PJI, particularly in the elderly who face higher mortality rates. Current diagnostic methods for suspected PJI, such as radiographs and biochemical markers like CRP and ESR, exhibit limited sensitivity. Therefore, there is a critical need for a specific synovial fluid biomarker assay to enhance PJI diagnosis using specific SF-based assay. RESULTS: This study introduces a novel microfluidic chip with a paper-based aptamer-sandwich assay for the quantitative detection of HNP 1, a crucial PJI biomarker, in synovial fluid. The assay leverages the advantages of aptamers over antibodies, demonstrating high selectivity and affinity for target molecules. The integration of a nitrocellulose (NC) membrane onto the microfluidic platform represents a significant advancement, reducing background signals and simplifying the assay procedure without intricate procedure and pre-treatment. The NC membrane-based microfluidic device offers rapid, cost-effective, and highly sensitive detection of HNP 1, with a limit of detection of 0.5 mg L-1. The microfluidic device demonstrates exceptional performance, detecting up to four clinical samples in approximately 42 min on a single chip with 100 % accuracy, as confirmed by analysis of 12 clinical samples and comparison with "gold-standard". Moreover, the assay exhibits a wide dynamic range of 0.5-100 mg L-1, underscoring its potential as a powerful tool for PJI diagnosis in clinical settings. SIGNIFICANCE: This work introduces a paper-based microfluidic system tailored for rapid HNP 1 detection using synovial fluid near joint region (and not serum via blood) for better diagnosis. The innovative paper-based aptamer-sandwich assay yields results within 42-min. Significantly, it boasts a wide dynamic range, detecting levels from an impressive 0.5 mg L-1, crucial in the 2.6 mg L-1 threshold region. This heightened sensitivity and expansive detection capability establish our assay as a leader in PJI diagnostics, promising unmatched precision and efficiency in clinical applications.


Asunto(s)
Aptámeros de Nucleótidos , Biomarcadores , Dispositivos Laboratorio en un Chip , Papel , Infecciones Relacionadas con Prótesis , Líquido Sinovial , alfa-Defensinas , Humanos , Aptámeros de Nucleótidos/química , Biomarcadores/análisis , Límite de Detección , Técnicas Analíticas Microfluídicas/instrumentación , Infecciones Relacionadas con Prótesis/diagnóstico , Líquido Sinovial/química , alfa-Defensinas/análisis
5.
Lab Chip ; 22(2): 250-261, 2022 01 18.
Artículo en Inglés | MEDLINE | ID: mdl-34918728

RESUMEN

Periprosthetic joint infections (PJIs) arising from joint arthroplasty are dreadful, yet difficult to diagnose in subtle cases. Definite diagnosis requires microbiological culture to confirm the causative pathogens. However, up to 40% of culture-negative PJI needs other surrogate biomarkers such as human neutrophil peptide 1 (HNP 1) to improve diagnostic accuracy or gauge therapeutic responses. To devise a diagnostic method, systematic evolution of ligands by exponential enrichment (SELEX) (five rounds) was used to screen PJI biomarkers on a compact (20 × 20 × 35 cm), integrated microfluidic system equipped with two separate Peltier devices and one magnetic control module where an aptamer with high affinity and specificity for HNP 1, which has been used as one of the synovial fluid (SF) biomarkers for detecting PJI, was identified for the first time. Two rounds of negative selection (with immunoglobulin G & human serum album) on-chip followed by one round of unique "competitive selection" with SF extracted from PJI patients validated the specificity of the HNP 1 aptamer. The dissociation constant was measured to be 19 nM. The applicability of SF HNP 1 levels for diagnosing PJI was then verified by a new aptamer-based enzyme-linked immunosorbent assay (ELISA)-like assay. It is envisioned that this new aptamer and the associated assay could be used in future clinical applications.


Asunto(s)
Infecciones Relacionadas con Prótesis , alfa-Defensinas , Biomarcadores/análisis , Humanos , Microfluídica , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Relacionadas con Prótesis/cirugía , Sensibilidad y Especificidad , Líquido Sinovial/química , alfa-Defensinas/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA