Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38914371

RESUMEN

OBJECTIVES: In remodeling valve-sparing root replacement with external annuloplasty, we compare long-term outcomes of a calibrated expansible extra-aortic ring with a homemade Dacron ring. METHODS: All patients (2003-2020) operated for root aneurysm with/without aortic insufficiency (AI) were included. The standardized CAVIAAR (conservation aortique valvulaire dans les insuffisances aortiques et anévrysmes de la racine-Valve sparing in aortic insufficiencies and root aneurysms) technique was root remodeling and external annuloplasty ring with the EXTRA-AORTIC Ring or homemade Dacron ring. RESULTS: Among 486 patients (age 52.3 ± 14.0 years) operated for root aneurysm, 375 (repair rate: 77.1%) underwent root remodeling with annuloplasty (extra-aortic ring, n = 289, vs Dacron ring, n = 86). At 10 years (median follow-up, 4.08 years' interquartile range, 1.95-7.61), unmatched and matched analysis showed that patients with extra-aortic ring had greater survival, similar to the general population (93.3% vs 79.9%, P = .097), lower reoperation incidence (2.0% vs 9.7%, P = .0098), and lower AI grade >2 recurrence (1.9% vs 11.2%, P = .0042), compared with patients with a Dacron ring. Mixed-effect model showed that with extra-aortic ring annuloplasty, annular dilation over time (P = .0033) was prevented and, compared with the homemade Dacron ring, root expansibility was better preserved (3.22% vs 2.12%, P = .002) and mean transvalvular gradient was lower (6.58 mm Hg vs 7.94 mm Hg, P = .001). Tricuspid and bicuspid valves with extra-aortic ring had similar reoperation (4.3% vs 0.85%, P = .65) and AI grade >2 incidence (2.7% vs 1.2%, P = .61), expansibility (P = .29), and diameter (P = .47), whereas mean transvalvular gradient was lower for tricuspid valves (5.58 mm Hg vs 7.60 mm Hg, P = .004). CONCLUSIONS: Valve-sparing root remodeling with calibrated expansible extra-aortic ring annuloplasty improves the outcomes of reoperation and recurrent AI compared with a homemade Dacron ring. It prevents dilation and maintains physiological root dynamics for durable valve repair.

2.
Surg Technol Int ; 432023 11 30.
Artículo en Inglés | MEDLINE | ID: mdl-38038175

RESUMEN

Redo aortic surgery poses significant challenges, particularly in complex scenarios involving congenital heart conditions that have been previously operated on several years prior. The integration of three-dimensional (3D) reconstruction and printing holds immense potential to greatly improve surgical precision, particularly in critical situations.

3.
J Thorac Cardiovasc Surg ; 165(4): 1335-1342.e2, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-33985805

RESUMEN

OBJECTIVE: During the last decade, special concerns have been raised about the anatomic relationships among the sinotubular junction, ventricular-aortic junction, and virtual basal ring to improve the results of root reconstruction. The aim of this study is to evaluate the in vivo anatomy of the aortic root after reimplantation with the Valsalva graft and the anatomic relationship between its components. METHODS: We analyzed 10 consecutive patients with tricuspid aortic valves who underwent reimplantation with the Valsalva graft between September and December 2019. Surgical clips were applied as markers at the level of proximal annular knots and at the distal reimplanted commissures on the neo-sinotubular junction. Electrocardiogram-gated computed tomography scan of the aortic root was performed. Coordinates of the markers were exported on a 3-dimensional modeling software, and the distances between the virtual basal ring and the Dacron graft basal landmarks were measured. RESULTS: The mean heights of Dacron graft basal landmarks from virtual basal ring were right-left commissure 7.1 ± 5.1 mm; right sinus 4.7 ± 4.1 mm; right-noncoronary commissure 2.8 ± 2.2 mm; noncoronary sinus 1.4 ± 1.6 mm; left-noncoronary commissure 2.2 ± 2.3 mm; and left sinus 2.0 ± 0.9 mm. The mean planar distances of basal Dacron graft landmarks from virtual basal ring (thickness) were right-left commissure 5.3 ± 3.1 mm; right sinus 2.8 ± 1.4 mm; right-noncoronary commissure 2.2 ± 1.5 mm; noncoronary sinus 1.5 ± 1.5 mm; left-noncoronary commissure 1.3 ± 1.0 mm; and left sinus 3.4 ± 2.5 mm. CONCLUSIONS: After reimplantation, despite a complete dissection of the root, slight asymmetry of graft proximal seating exists. The inner annuloplasty is on the virtual basal ring, and the proximal edge of the Dacron graft is on the ventricular-aortic junction at a slightly different thickness and height along the annular circumference. At the level of the right sinus and left/right commissure, the Dacron graft is higher than the virtual basal ring and the relative wall thickness is increased. The annular stabilization is unaffected.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Válvula Aórtica , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Válvula Aórtica/anatomía & histología , Aorta Torácica , Tereftalatos Polietilenos , Aorta/diagnóstico por imagen , Aorta/cirugía , Reimplantación , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/cirugía
4.
J Card Surg ; 37(10): 3428-3431, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35989513

RESUMEN

Although mid- and long-term outcomes after the Ross procedure for aortic valve disease have been increasingly improving over the years, this is still a rather challenging operation in neonates and small children. This is particularly true for patients with associated congenital heart defects and critical clinical conditions. Herein we describe the application of this procedure as a rescue operation in emergency circumstances in a low-birth-weight neonate with severe aortic stenosis, aortic regurgitation and mitral regurgitation after a previous aortic coartectomy.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Válvula Pulmonar , Válvula Aórtica/anomalías , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/congénito , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Niño , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Recién Nacido de Bajo Peso , Recién Nacido , Válvula Mitral/cirugía , Válvula Pulmonar/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
5.
Surg Technol Int ; 412022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35920336

RESUMEN

BACKGROUND: Transplantation in the management of end-stage organ failure in patients with Anderson- Fabry disease is still a matter of debate due to a lack of data regarding long-term outcomes and prognosis. OBSERVATIONS: Most of the cases in the literature did not receive enzyme-replacement therapy (ERT), or received it only years after transplantation. Based on our experience, we describe here the long-term results of heart transplant in combination with early ERT. CONCLUSIONS: Transplantation combined with lifelong ERT should be considered to offer patients a chance of good long-term outcomes and quality of life.

6.
Eur J Cardiothorac Surg ; 61(4): 888-896, 2022 03 24.
Artículo en Inglés | MEDLINE | ID: mdl-34962258

RESUMEN

OBJECTIVES: The goal of this multicentre retrospective study was to compare long-term clinical and haemodynamic outcomes of the Carpentier-Edwards Magna Ease (CEME) bioprosthesis by patient age. METHODS: We included consecutive patients who underwent isolated and combined surgical aortic valve replacement (AVR) with CEME valve between January 2008 and March 2020 at 4 cardiac surgery centres in Italy. Survival distribution was evaluated at follow-up according to age and surgery type (combined or isolated AVR), together with freedom from structural valve deterioration (SVD), reoperation and combined events, i.e. SVD, reoperation, endocarditis and thromboembolic events. RESULTS: A total of 1027 isolated and 1121 combined AVR were included; 776 patients were younger than 65 years whereas 1372 were 65 years or older. The 30-day Valve-Academic-Research-Consortium mortality was 2% (<65 years) and 6% (≥ 65 years) (P < 0.001), whereas it was 3% for isolated AVR and 7% for combined AVR (P < 0.001). The 12-year survival was 81% for those younger than 65 years vs 45% for those equal to or older than 65 years (P < 0.001), whereas they were 61% vs 49% for isolated and combined AVR (P = 0.10). The 12-year freedom from combined events, excluding death, was 79% for those younger than 65 years vs 87% for those equal to or older than (P = 0.51), whereas they were 83% for isolated and 86% for combined AVR (P = 0.10). The 12-year freedom from SVD was 93% and 93% in patients younger than 65 and those equal to or older than 65 years (P = 0.63), and the results were comparable even in cases with isolated and combined AVR (92% vs 94%, P = 0.21). A multivariable Cox analysis including gender, presence of patient-prosthesis mismatch, isolated AVR and age showed that only the age was an independent risk factor for the incidence of SVD (P = 0.029). CONCLUSIONS: Outcomes from this large multicentre analysis demonstrated that a CEME bioprosthesis provides good clinical results and long-term durability even in patients younger than 65 years. Furthermore, the hazard for SVD has been shown to be lower for older age. CLINICAL TRIAL REGISTRATION NUMBER: 105n/AO/21.


Asunto(s)
Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Estudios de Seguimiento , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Diseño de Prótesis , Falla de Prótesis , Reoperación , Estudios Retrospectivos
7.
Semin Thorac Cardiovasc Surg ; 34(3): 844-851, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34216751

RESUMEN

Aortic annuloplasty has demonstrated to be a protective factor in valve-sparing root replacement and aortic valve repair. Both reimplantation for aortic root aneurysms and external ring annuloplasty for isolated aortic regurgitation have demonstrated good long-term results. The aim of this anatomical study is to compare aortic reimplantation with Valsalva graft with aortic external ring annuloplasty in bicuspid aortic valves, analyzing their morphological features with CT scan. We selected 56 patients with bicuspid aortic valve who underwent reimplantation procedure with Valsalva graft or external ring annuloplasty; after propensity-matching, 2 homogeneous groups of 10 patients each were obtained. Through multiplanar ECG-gated CT-Scan reconstructions, pre- and postoperative, aortic annular, and valve geometrical characteristics were compared (diameters, perimeter, area and ellipticity index for the annulus; effective height, coaptation length and commissural height for the valve). Aortic root volume was also analyzed. Postoperative comparison of the two groups showed similar geometric features of the aortic annulus in terms of major and minor diameters, perimeter, area and ellipticity index. Analysis of valve's parameters showed similar results in terms of effective height and coaptation length (respectively 10.9 ± 2.1 mm and 7.5 ± 1.9 mm in External Ring group and 10.1 ± 2.0 mm and 7.6 ± 1.6 mm in the Reimplantation group). Both techniques achieve an efficient annuloplasty with similar anatomical results on bicuspid the aortic valves. The stability of these results needs to be confirmed by long-term clinical and echocardiographic follow-up.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Anuloplastia de la Válvula Cardíaca , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Anuloplastia de la Válvula Cardíaca/efectos adversos , Humanos , Reimplantación , Resultado del Tratamiento
8.
Surg Technol Int ; 35: 197-201, 2020 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-32120449

RESUMEN

INTRODUCTION: Progressive saphenous vein graft (SVG) failure remains a key limitation to the long-term success of coronary artery bypass grafting (CABG). SVG disease after the first year is dominated by intimal hyperplasia, which predisposes the SVG to thrombosis and accelerated atherosclerosis. The objective of this study was to review and summarize the latest experimental and clinical data on the use of mechanical external stents for vein grafts. METHODS: In January 2020, the PubMed database was searched using the terms "external stent", "CABG", "saphenous vein graft" and "intimal hyperplasia". The results were reviewed and only randomized experimental and clinical studies that analyzed the effect of external stenting on venous intimal hyperplasia were included in the analysis, together with studies that investigated the clinical benefit of external stenting. RESULTS: Eight experimental and four clinical trials met the search criteria. Controlled trials in different large animal models concluded that external stenting significantly reduced intimal hyperplasia 3-6 months post implantation, and reduced both thrombosis rates and the development of lumen irregularities. Data from randomized controlled trials with a follow-up period of 1-4.5 years supported the pre-clinical findings and demonstrated that external stents significantly reduced vein graft disease. CONCLUSION: Strong evidence indicates that supporting the vein with external stents is safe and leads to clear advantages at both the anatomical and cellular levels. With the further accumulation of consistent positive results, external stenting of SVG may become the standard of care in future CABG.


Asunto(s)
Puente de Arteria Coronaria/métodos , Oclusión de Injerto Vascular/prevención & control , Vena Safena/trasplante , Stents , Túnica Íntima/patología , Animales , Aterosclerosis/etiología , Aterosclerosis/prevención & control , Implantación de Prótesis Vascular/métodos , Oclusión de Injerto Vascular/etiología , Humanos , Hiperplasia/cirugía , Ensayos Clínicos Controlados Aleatorios como Asunto , Vena Safena/cirugía , Trombosis/etiología , Trombosis/prevención & control , Túnica Íntima/cirugía , Grado de Desobstrucción Vascular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA