Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Orthop Res Rev ; 16: 233-242, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39385973

RESUMEN

The Anterior Cruciate Ligament (ACL) is considered the most commonly injured ligament of the knee. Magnetic Resonance Imaging (MRI) has become an indispensable imaging tool and modality of choice for assessing and managing knee conditions. This article outlines an effective MRI imaging technique that improves the diagnostic accuracy of ACL injuries of the knee, covering the appropriate pulse sequences and optimal imaging planes. Furthermore, the article provides a comprehensive review of the appearance of complete and partial ACL tears on MRI in the acute and chronic phases. In addition, it identifies and illustrates the primary MRI signs (signs related to the absence or abnormal visualization of the ACL fibers) and secondary MRI signs (signs related to the mechanism of injury or associated knee injuries) of ACL injury.

2.
Orthop Rev (Pavia) ; 16: 120049, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39105053

RESUMEN

Background: The wrist is a complex joint that plays a role in several everyday tasks. Various radiological indices have been created to assess the alignment and structure of the wrist using standard X-ray images. Nevertheless, these indicators may differ based on variables such as age, gender, ethnicity, handedness, and wrist position. This research aimed to assess the radiological indices of the wrist in a group of healthy people from Jordan and investigate the impact of age and gender on these indices. Methods: We obtained data from a sample of 385 patients who presented at our hospital with minor non-specific wrist pain and satisfied the specified criteria for inclusion. We conducted measurements of radial inclination, radial height, volar tilt, ulnar variance, and carpal height ratio using both anteroposterior and lateral views of the wrist. We used linear regression and independent sample t-test to examine the correlation between age, gender, and radiological indicators. The reliability of the measurements was assessed using the intraclass correlation coefficient (ICC). Results: Our study revealed a negative correlation between age and carpal height ratio (r = -0.13, p = 0.03). However, no significant gender differences were seen in any of the radiological indices (p > 0.05). Our findings indicate that ulnar variance had the greatest level of reliability across observers, with an intra-observer intraclass correlation coefficient (ICC) of 0.95 and an inter-observer ICC of 0.8. Conversely, volar tilt exhibited the lowest inter-observer reliability, with an ICC of 0.1.Our results provide a valuable point of reference for the wrist morphology and alignment in the Jordanian population. Our suggestion is that the carpal height ratio might indicate alterations in the wrist joint due to aging, whereas ulnar variation may serve as a dependable indicator of wrist alignment. We suggest doing more research to investigate the biological and anatomical factors behind these results and to compare them with other demographic groups.

3.
BMC Musculoskelet Disord ; 25(1): 524, 2024 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-38982384

RESUMEN

INTRODUCTION: The wrist joint is a complex anatomical structure, and various radiographic parameters are utilized to assess its normal alignment and orientation. Among these parameters are carpal height ratio (CHR) and ulnar variance (UV). Previous literature has indicated that factors such as age and gender may influence these parameters; However, there is a lack of studies investigating these differences specifically in the Middle East or Jordan. Additionally, no prior research has explored the relationship between UV and CHR. Therefore, the objective of this study is to investigate these critical radiological parameters and their associations. METHODOLOGY: A cross-sectional study design was employed, wherein a total of 385 normal wrist X-rays were reviewed, and CHR and UV were measured. Intra-observer and inter-observer reliability assessments were conducted to ensure the consistency and accuracy of measurements. Additionally, the association between UV and CHR was measured and plotted for further analysis. RESULTS: In our study, the mean CHR was 0.5 (range: 0.4 to 1.5), and the mean UV was - 0.3 mm (range: -5.8 mm to 4.1 mm). We found a significant negative correlation between CHR and age (p < 0.05). No significant gender differences were observed in UV and CHR. Additionally, a weak positive correlation was found between UV and CHR (Pearson correlation coefficient = 0.13, p = 0.01; adjusted R2 = 0.014, p = 0.02). CONCLUSION: Age correlated significantly with a decline in carpal height ratio. Additionally, ulnar variance had a week positive yet significant correlation with carpal height ratio. LEVEL OF EVIDENCE: Cross-sectional study, Level III.


Asunto(s)
Huesos del Carpo , Radiografía , Cúbito , Articulación de la Muñeca , Humanos , Masculino , Femenino , Estudios Transversales , Cúbito/diagnóstico por imagen , Cúbito/anatomía & histología , Huesos del Carpo/diagnóstico por imagen , Huesos del Carpo/anatomía & histología , Adulto , Persona de Mediana Edad , Articulación de la Muñeca/diagnóstico por imagen , Articulación de la Muñeca/anatomía & histología , Anciano , Adulto Joven , Adolescente , Jordania , Anciano de 80 o más Años , Reproducibilidad de los Resultados
4.
J Bone Joint Surg Am ; 105(2): 145-156, 2023 01 18.
Artículo en Inglés | MEDLINE | ID: mdl-36651890

RESUMEN

BACKGROUND: There is currently a lack of evidence to identify the optimal patellar implant design in total knee arthroplasty (TKA). The aim of this study was to assess clinical, intraoperative, radiographic, and scintigraphic differences between inlay (IN), onlay round (OR), and onlay oval (OO) patellar implants. METHODS: A parallel-group, double-blinded, randomized trial compared IN, OR, and OO patellar implants using the same posterior-stabilized TKA prosthesis for each. Patient outcomes were prospectively followed for a minimum of 2 years, with survivorship outcomes followed for a mean of 5 years. The primary outcome was the between-group differences in the mean Kujala score change from preoperatively to 2 years postoperatively. The secondary outcomes included differences in other knee-specific and general health outcomes, intraoperative characteristics, radiographic parameters, patellar vascularity, and implant survivorship. RESULTS: A total of 121 participants (40 in the IN group, 41 in OR group, 40 in the OO group) were allocated to 1 of 3 implant designs. At 2 years postoperatively, there were no significant differences in Kujala score changes between groups (p = 0.7; Kruskal-Wallis test). Compared with the IN group, the OR group showed greater improvements in Knee injury and Osteoarthritis Outcome Score (KOOS) Activities of Daily Living and in KOOS Quality of Life compared with the OO group. However, the OO design exhibited better bone coverage and lower lateral facetectomy rates compared with the IN and OR designs. The IN group had more lateral contact compared with the OO group (p = 0.02; Fisher exact test), but the overall value for lateral contact was not significant (p = 0.09; chi-square test). There were no differences in postoperative scintigraphic vascularity (p = 0.8; chi-square test). There was 1 revision for infection at 3 years postoperatively in the OO group, and no revision in the other groups. CONCLUSIONS: Patellar design did not influence patellofemoral outcomes or survivorship. However, OR implants showed improvements in some secondary patient-reported outcome measures, and OO implants exhibited superior bone coverage and improvements in several intraoperative, radiographic, and scintigraphic outcomes. These findings, combined with superior long-term implant survivorship from previous studies, add support for the use of onlay designs in TKA. LEVEL OF EVIDENCE: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Actividades Cotidianas , Calidad de Vida , Resultado del Tratamiento , Articulación de la Rodilla/cirugía , Rótula/diagnóstico por imagen , Rótula/cirugía , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/cirugía
5.
ANZ J Surg ; 91(9): 1914-1918, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34152666

RESUMEN

BACKGROUND: Portable accelerometer-based navigation devices (PAD) in total knee arthroplasty (TKA) have been proposed to combine the alignment precision of computer navigation with the efficiency of conventional instrumentation (CON). The aim of this study was to determine if PAD was more effective than CON in TKA in improving clinical outcomes at medium term follow-up. METHODS: Participants undergoing primary TKA were randomly assigned to either PAD or CON. The primary outcome was the mean between-group difference in the four subscales of the Knee injury and Osteoarthritis Outcome Score (∆KOOS4 ) between preoperative status and latest follow-up. Secondary outcomes included analysis of between-group differences in all KOOS subscales, Western Ontario and McMaster Universities Osteoarthritis Index (∆WOMAC) scores, complications and reoperation rates. RESULTS: Of the 178 participants allocated to a treatment arm, 159 (89.3%) completed follow-up at a mean of 4.3 years (range 3.2-5.8 years). There was no statistically significant or clinically meaningful difference in ∆KOOS4 between preoperative status and latest follow-up (PAD = 41, CON = 43; p = 0.5). There was no difference in mean ∆WOMAC scores (PAD = 39, CON = 41; p = 0.9) or ∆KOOS subscales between groups. In addition, there were no differences in complications or reoperations between groups. CONCLUSIONS: PAD was not superior to CON in improving patient-reported outcomes or reducing complications and reoperation rates at medium term follow-up. The use of PAD in TKA to improve clinical outcomes alone cannot be justified based on the results of this study.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Humanos , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Reoperación , Factores de Tiempo , Resultado del Tratamiento
6.
ANZ J Surg ; 90(7-8): 1303-1309, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32455501

RESUMEN

BACKGROUND: Despite debate over the role of patellar resurfacing in total knee arthroplasty, many surgeons feel it decreases re-operation rates and anterior pain, and an increasing number are adopting resurfacing. This study compares intra-operative characteristics of different patellar implants to assist surgeons in gaining better understanding of these implants. METHODS: The three most commonly used patellar implants (inset, onlay round and onlay oval) were allocated randomly to 120 patients undergoing total knee arthroplasty. We compared the groups in terms of implant size, bone coverage, lateral underhang (uncovered lateral facet) and need for partial lateral facetectomy. We also compared the patient-reported outcome measures between the groups at 6 months post-operatively. RESULTS: The inset, onlay round and onlay oval designs had bone coverage of 48.5%, 65.9% and 85.9%, respectively (P < 0.01). Similarly, the onlay-oval implant was found to have the smallest lateral underhang of all three designs (inset 11.6 mm; onlay round 6.9 mm, onlay oval 1.6 mm, P < 0.01). The onlay-oval design was the largest implant with a median size of 35 mm, compared to 23 mm for the inset and 32 mm for the onlay round (P < 0.01). In addition, patellae using onlay-oval implants required significantly fewer lateral facetectomies due to improved bone coverage (inset 95%; onlay round 87%; onlay oval 3%; P < 0.01). Finally, comparison of patient-reported outcome measures between the groups showed no difference at an early assessment of 6 months. CONCLUSION: Onlay-oval design allows for the use of a larger implant, improving bone coverage and reducing the need for partial lateral facetectomy; however, early assessment of outcomes shows no difference between the three designs.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Rótula/cirugía , Diseño de Prótesis , Reoperación , Resultado del Tratamiento
7.
Orthop Rev (Pavia) ; 12(4): 8833, 2020 Dec 31.
Artículo en Inglés | MEDLINE | ID: mdl-33585025

RESUMEN

Amid the current pandemic of coronavirus disease 2019 (COVID-19), orthopaedic surgery was one of the fewer specialties that remained active managing emergent and urgent orthopaedic and trauma cases. On the other hand, with the continued spread of this pandemic and its associated socioeconomic confinement and unpredictability of the pandemic curve; many health care facilities were forced into halting all elective and non-urgent activities including orthopaedic specialties. This in part was to help in reallocation of required resources and focusing on the proper management of COVID-19 patients, and to prevent the transmission of infection among health care workers and patients. In this article we analyzed developments and recommendations of international reports about the current outbreak and its impact on the practice of orthopaedic surgery. Our aim was to provide comprehensive and easy guidelines for the management of urgent and emergent cases in hot zones and for the process of returning to usual orthopaedic work flow in a balanced strategy to assure safe practice and providing quality care without the risk of exhausting institutional resources or the risk of COVID- 19 transmission among health care workers or patients.

8.
J Arthroplasty ; 34(2): 290-294.e1, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30389257

RESUMEN

BACKGROUND: Soft tissue balance is believed to be a major determinant of improved outcomes in total knee arthroplasty (TKA). We conducted this study to assess the accuracy of surgeon-defined assessment (SDA) of knee balance compared to pressure sensor data. We also assessed for any association between experience (learning curve) and accuracy of SDA. METHODS: A total of 308 patients undergoing 322 mechanically aligned TKA were prospectively analyzed. Femoral and tibial trial implants were inserted before performing knee balancing. We compared the surgeon determination on knee balance at 10°, 45°, and 90° of flexion to sensor data at the same flexion angles. RESULTS: Accuracy of SDA was 63%, 57.5%, and 63.8% at 10°, 45°, and 90°, respectively, when compared to sensor data. SDA had an overall sensitivity of 81% and specificity of 37.7%. Capacity to determine an unbalanced knee worsened at higher knee flexion angles with SDA test specificity of 53.5%, 34.8%, and 24.8% at 10°, 45°, and 90°, respectively (P = .0004 at 10° vs 45°, P < .0001 at 10° vs 90°). Cohen's kappa coefficient was 0.29 at 10° indicating fair agreement, and 0.14 and 0.12 at 45° and 90°, respectively, indicating poor agreement. The use of sensor had no time-based learning effect on capacity to determine knee balance. CONCLUSION: SDA is a poor predictor of the true soft tissue balance when compared to sensor data, particularly in assessing whether a knee is unbalanced. In addition, increased use of sensors did not improve surgeon capacity to determine knee balance.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/instrumentación , Articulación de la Rodilla/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/métodos , Femenino , Fémur/cirugía , Humanos , Articulación de la Rodilla/fisiología , Prótesis de la Rodilla , Curva de Aprendizaje , Masculino , Persona de Mediana Edad , Presión , Rango del Movimiento Articular , Rotación , Cirujanos , Tibia/cirugía
9.
Knee ; 25(6): 1262-1271, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30409497

RESUMEN

BACKGROUND: Standard radiographic views for patellofemoral joint assessment do not reflect loading at which TKA patients may describe post-operative anterior symptoms. A novel weight bearing (WB) Merchant view has been described and demonstrated a number of tracking changes that correlated with clinical outcomes. In this study, we aim to validate the WB Merchant view and assess relationships with patient outcome scores. METHODS: Patients were randomly allocated to receive one of the three commonly used patellar implants with a single TKA prosthesis. Patients were evaluated at six months post-operatively using both NWB and WB Merchant views. Indicators of patellar tracking were correlated with improvement in KOOS, WOMAC and Kujala scores. For reliability assessment, radiographs were assessed twice by two readers. RESULTS: The WB Merchant view showed a reduction in the percentage of outliers of tracking indices in comparison to the NWB view (Congruence angle: NWB = 37%, WB = 24%; Displacement: NWB = 2%, WB = 0%; Tilt angle: NWB = 60%, WB = 56%). There was an increase in the lateral contact state with the WB Merchant view (Type I: NWB = 19%, WB = 28%; Type II: NWB = 3%, WB = 4%). The state of lateral contact had a consistent and statistically significant correlation with the improvement in KOOS, WOMAC and Kujala scores (p value = 0.01, 0.01 and 0.03, respectively). All radiographic indices had good reliability with accepted variability. CONCLUSION: The WB Merchant radiograph is an easy to perform and reliable view for the evaluation of patellar tracking and may provide additional information to the routinely used NWB view.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Prótesis de la Rodilla/estadística & datos numéricos , Articulación Patelofemoral/cirugía , Diseño de Prótesis/estadística & datos numéricos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/cirugía , Rótula/diagnóstico por imagen , Rótula/cirugía , Articulación Patelofemoral/diagnóstico por imagen , Reproducibilidad de los Resultados , Soporte de Peso
10.
ANZ J Surg ; 88(5): 497-501, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29457342

RESUMEN

BACKGROUND: Sensor-guided assessment for soft tissue balance in total knee arthroplasty (TKA) has been reported to improve patient satisfaction and self-reported outcome scores. As more surgeons adopt this technology in TKA, we performed this study to identify if there is a learning curve with its use. METHODS: Analysis of a total of 90 consecutive cases was performed in this study. Initial and final intercompartmental pressure differences were recorded before and after knee ligament balancing. The first 45 patients (group 1) were compared to the last 45 patients (group 2) in terms of operative time and the final state of knee balance. A balanced knee was defined as pressure difference between medial and lateral compartments of ≤15 pounds. RESULTS: Group 1 had 10 unbalanced knees in the final pressure difference assessment, while all cases in group 2 were balanced (P < 0.001). There was no statistically significant difference in mean operative time between the two groups. A scatter plot of intercompartmental pressure difference identified that after 30 cases, the capacity to achieve knee ligament balance improved. CONCLUSION: This study suggests that there is a learning curve with the use of sensor-guided assessment in TKA in achieving knee balance; however, the differences noted between initial and final groups were small and may not be of clinical significance.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Inestabilidad de la Articulación/prevención & control , Ligamentos Articulares/fisiología , Osteoartritis de la Rodilla/cirugía , Satisfacción del Paciente/estadística & datos numéricos , Anciano , Fenómenos Biomecánicos , Humanos , Prótesis de la Rodilla , Curva de Aprendizaje , Persona de Mediana Edad , Osteoartritis de la Rodilla/diagnóstico por imagen , Medición de Resultados Informados por el Paciente , Estudios Prospectivos , Rango del Movimiento Articular/fisiología , Resultado del Tratamiento
11.
J Arthroplasty ; 32(3): 777-782, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-27667534

RESUMEN

BACKGROUND: Accelerometer-based, portable navigation devices have been introduced as a less invasive and simpler technique to perform navigated surgical implantation of knee prostheses. They have been postulated to have better accuracy than conventional instruments in restoration of alignment in total knee arthroplasty. METHODS: A total of 190 patients were enrolled in this prospective, randomized controlled trial and underwent total knee arthroplasty using either the KneeAlign or conventional guides. Multiplanar alignment was evaluated with a CT imaging protocol. RESULTS: A total of 86.5% of portable navigation device and 82.2% of conventional group had a postoperative hip-knee angle within 3° of neutral alignment (P = .54). There was no significant difference between the 2 groups for component coronal and sagittal plane alignment. Portable navigation device did not significantly increase the time to perform the surgery. CONCLUSION: Portable navigation device demonstrates accurate restoration of alignment; however, there was no statistically significant difference when compared with conventional guides.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/instrumentación , Cirugía Asistida por Computador/instrumentación , Acelerometría , Anciano , Artroplastia de Reemplazo de Rodilla/métodos , Femenino , Humanos , Rodilla/cirugía , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Cirugía Asistida por Computador/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA