Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros




Base de datos
Asunto de la revista
Intervalo de año de publicación
1.
Diagnostics (Basel) ; 12(11)2022 Oct 31.
Artículo en Inglés | MEDLINE | ID: mdl-36359490

RESUMEN

This is a retrospective single-center study that included 87 subjects. All subjects had chronic hepatitis B or HBV cirrhosis and underwent nucleos(t)ide analogs (NUC) treatment for more than one year. The study aimed to evaluate the dynamic changes in liver stiffness (LS) measured by transient elastography (TE) during a median interval of 64 months. Patients were assessed prior to starting therapy and followed up annually. Liver stiffness measurements (LSM) were performed annually, and ten valid LSMs were obtained in each session. Reliable LSMs were defined as the median value of 10 measurements with Interquartile range/median (IQR/M) ≤ 30%. A significant decrease in liver stiffness values (p < 0.001) was observed during follow-up. In patients with liver cirrhosis, the LSMs decreased significantly after only one year, 24.6 ± 4.3 kPa vs. 13.5 ± 4.2 kPa (p = 0.007), whereas the decrease in non-cirrhotic patients was not significant, 7.31 ± 3.62 vs. 6.80 ± 2.41 (p = 0.27). Liver stiffness decrease was more significant in patients with initially higher transaminases. Undetectable viral load was achieved in 73.5% of patients in year one, 82.7% in year two, and 90.8% in year three of treatment. In conclusion, our study reveals a decrease in liver stiffness by TE in patients with chronic hepatitis B when undergoing anti-HBV therapy in the first two years. It can be used as a method for follow-up in patients undergoing NUC therapy.

2.
Clujul Med ; 90(1): 28-32, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28246494

RESUMEN

The aim of the paper was to propose a score for performance evaluation in colonoscopy units. METHOD: We proposed a score (CDCD score - Cecal intubation, polyp Detection rate, Cleansing and Documentation of cecal intubation) based on the following parameters that assess the quality of colonoscopy units: total colonoscopies rate, polyp detection rate, rate of cecal intubation photo record, rate of recorded Boston bowel preparation scale (BBPS) (rated 1 to 5 stars). The mean score obtained based on the above mentioned criteria was used as a quality parameter of the endoscopy unit. We applied and calculated this score in all screening colonoscopies performed in our Endoscopy Department during the last 4 years. RESULTS: The study group included 856 screening colonoscopies. The rate of total colonoscopies was 92.1% (789/856 cases) and the polyp detection rate was 23.9%. Regarding the quality of bowel preparation, the BBPS was recorded in 51.1% cases. The cecal intubation was photo recorded in 44% of cases. We considered that of the 4 parameters, the highest weight for an excellent quality belonged to the cecal intubation rate, followed by the polyp detection rate, because they evaluate the endoscopic technique, while the other 2 are more administrative. Thus, for the unit's assessment we used the following equation: UNIT'S QUALITY CDCD SCORE = (3×cecal intubation rate+3×polyp detection rate+1×photo documentation+1×BBPS documentation)/8. Thus, the CDCD Score for our unit was ≈4 stars (3.7 stars). CONCLUSION: The proposed CDCD score may be an objective tool for the quality assessment in different endoscopy units.

3.
Ann Hepatol ; 11(5): 691-5, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22947531

RESUMEN

AIM: Liver biopsy (LB) is often essential for the diagnosis and staging of chronic viral hepatitis. The aim of our paper was to establish if the size of the biopsy needle influences the number of portal tracts obtained through LB. MATERIAL AND METHODS: We conducted a retrospective study on 596 echoassisted percutaneous LBs performed in the Department of Gastroenterology and Hepatology Timisoara during a 4 years period. We included only those biopsy results that had mentioned both the type of needle and the number of portal tracts. All LBs were echoassisted and performed with Menghini modified needles 1.4 and 1.6 mm in diameter (technique with two passages into the liver). The liver fragments were analyzed by a senior pathologist and Knodell score was used to describe necroinflammatory activity as well as fibrosis. We compared the number of portal tracts obtained with 1.4 vs. 1.6 Menghini needles. RESULTS: Type 1.4 mm Menghini needles were used for 80 LBs, while 1.6 mm type were used in 516 LBs. Liver fragments obtained with 1.6 mm Menghini needles had a significantly higher mean number of portal tracts as compared to those obtained with 1.4 needles (24.5 ± 10.6 vs. 20.8 ± 8.6, p = 0.003). CONCLUSION: The 1.6 mm Menghini needles provide better liver biopsy specimens, with higher number of portal tracts, as compared to 1.4 mm Menghini needles.


Asunto(s)
Biopsia/instrumentación , Hepatopatías/patología , Hígado/patología , Agujas , Adulto , Distribución de Chi-Cuadrado , Diseño de Equipo , Femenino , Hepatitis B Crónica/patología , Hepatitis C Crónica/patología , Humanos , Cirrosis Hepática/patología , Cirrosis Hepática/virología , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico , Estudios Retrospectivos , Rumanía , Índice de Severidad de la Enfermedad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA