1.
Int J Prosthodont ; 36(5): 588-594, 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-33651033

RESUMEN

PURPOSE: To evaluate the efficacy of cleaning protocols for the decontamination of organic compounds from polished zirconium oxide samples. MATERIALS AND METHODS: A total of 24 rectangular plate specimens were sintered from zirconium oxide. All samples were polished with commercially available polishers (coarse, fine, and superfine) and polishing paste. During the first step of the protocol, all specimens were cleaned with steam. Samples were then randomly assigned to one of three groups (n = 8 each): A, B, or C. In group A, no additional cleaning was performed, while specimens in group B underwent ultrasonic cleaning in distilled water. Group C specimens were cleaned in an ultrasonic bath with a special detergent solution. After washing, samples were subjected to energy-dispersive x-ray spectroscopy (EDX) and scanning electron microscopy (SEM) examination. In order to detect organic materials, the level of carbon atoms was measured. RESULTS: EDX analysis revealed that samples in group A had the highest percent of carbon atoms (9.57 ± 3.67) on the surface compared to other cleaning protocols. Following the Group B cleaning protocol resulted in lower carbon levels (4.73 ± 3.56), but this difference was not significant compared to group A (P = .439). None of the specimens in group C had detectable carbon atoms (0), which implies that all wax molecules were removed (P < .05). CONCLUSION: Total decontamination of organic compounds from a polished zirconium surface can be expected only following the C cleaning protocol; therefore, it is advised to employ an ultrasonic bath with detergent solution for cleaning procedures of zirconium abutments before delivery. Int J Prosthodont 2023;36:588-594.


Asunto(s)
Detergentes , Circonio , Circonio/química , Propiedades de Superficie , Microscopía Electrónica de Rastreo , Carbono , Ensayo de Materiales , Pulido Dental
2.
Int J Oral Maxillofac Implants ; 37(2): 320-327, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35476860

RESUMEN

PURPOSE: To determine the effect of 0.7- and 2.4-mm transmucosal abutment height titanium bases on the crestal bone stability and peri-implant soft tissue condition of bone-level implants with platform switching in patients with vertically thick soft tissues. MATERIALS AND METHODS: Sixty bone-level platform-switched implants were placed in the molar and premolar regions of both arches in 60 patients. All epicrestally inserted nonsubmerged implants had a 4.1-mm diameter and, after osteointegration, were randomly allocated into two groups: (1) the short group, with a titanium base of 0.7-mm transmucosal abutment height, and (2) the high group with a 2.4-mm height. Monolithic zirconia restorations were fabricated for all implants. Parallel intraoral radiographs were obtained after the delivery of restorations (T1) and after 1 year (T2). Crestal bone levels and peri-implant soft tissue conditions were calculated for each implant. The significance level was set at α = .05. RESULTS: After 1 year, 55 patients were evaluated, with a mean bone loss of 0.6 ± 0.51 mm (median: 0.71, range: 0 to 2.09 mm) in the short group (23 patients) and 0.45 ± 0.59 mm (median: 0.65, range: 0 to 2.12 mm) in the high group (22 patients), showing no significant difference between groups (P = .168). A significant increase in marginal bone height was noted between the T1 and T2 time points in the short and high (P = .029 and .001, respectively) groups. The peri-implant soft tissue health parameters did not show statistically significant differences. CONCLUSION: Crestal bone stability after 1 year of follow-up around epicrestally placed platform-switched implants is not influenced by transmucosal abutment height, if the vertical soft tissue thickness is ≥ 3 mm.


Asunto(s)
Pérdida de Hueso Alveolar , Implantes Dentales , Pérdida de Hueso Alveolar/diagnóstico por imagen , Pérdida de Hueso Alveolar/etiología , Implantación Dental Endoósea , Estudios de Seguimiento , Humanos , Titanio
3.
Clin Implant Dent Relat Res ; 23(2): 259-269, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33527729

RESUMEN

BACKGROUND: The relation between implant abutment disconnection (AD) and increased crestal bone loss is still debated. PURPOSE: To compare bone changes below implant-abutment junction of subcrestally placed implants between: (1) implant level restorations, that underwent four ADs and (2) implants with immediate tissue level abutment with no AD, 1 month (T2) and 1-year (T3) after final restoration delivery. MATERIALS AND METHODS: Sixty-four patients received 64 bone level implants with platform-switching and conical connection in edentulous sites of posterior mandible and maxilla. All implants were placed 1.5 mm subcrestally and distributed among: (1) control group, that received a regular healing abutment and (2) test group with immediate tissue level (ITL) abutment, which was torqued to implants during surgery, transforming bone level implant to tissue level type. After 2-3 months of healing and a 1-month temporization, final zirconia-based screw-retained crowns were delivered to both groups. Crestal bone levels were calculated after final crown delivery (T2); after 1-year follow-up (T3) and compared using Mann-Whitney U test (p ≤ .05). RESULTS: Early bone loss of the test and control groups was 0.14 ± 0.27 mm and 0.64 ± 0.64 mm, respectively; the 0.5 mm difference was statistically significant (p = .0001). Late bone loss was 0.06 ± 0.16 mm and 0.21 ± 0.56 mm for the test and control group, respectively; the 0.15 mm difference between the groups was no more statistically significant (p = .22). Both groups displayed bone gain, 0.08 and 0.43 mm, respectively, and the overall crestal bone loss was reduced. CONCLUSIONS: Immediate tissue level abutments can significantly reduce early bone loss when measured 1 month after final prosthesis delivery, however, after 1-year follow-up, difference between the groups was no more statistically significant.


Asunto(s)
Pérdida de Hueso Alveolar , Implantes Dentales , Pérdida de Hueso Alveolar/etiología , Coronas , Diseño de Implante Dental-Pilar , Implantación Dental Endoósea , Restauración Dental Provisional , Estudios de Seguimiento , Humanos
4.
Clin Implant Dent Relat Res ; 22(4): 497-506, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32250061

RESUMEN

PURPOSE: Aims of the study were: (a) to register crestal bone loss around 1.5 mm subcrestally placed implants and epicrestally placed implants with soft tissue tenting technique, (b) to record bone remodeling in subcrestal group, and (c) to determine the increase of vertical soft tissues after tenting. MATERIALS AND METHODS: Thirty-two patients with vertically thin tissues of 2 mm or less received 40 submerged bone level platform-switched implants, divided into two groups-(a) 1.5 mm subcrestally placed implants and (b) epicrestally placed implants with soft tissue tenting over 2 mm healing abutments. At the second stage surgery, implants received 4 mm healing abutments, soft tissue thickness was measured in epicrestal group, and later implants were restored with zirconia-based screw-retained single restorations. Radiological images were taken at the second stage surgery, restoration delivery and after 2 years of follow-up. Bone loss was calculated as a distance between implant neck and first radiographically visible bone-to-implant contact. Bone remodeling was calculated as a distance between the bone crest and implant neck. Mann-Whitney U test was used for statistical analysis, significance set to 0.05. RESULTS: After 2 years of follow-up, Group 1 (subcrestal) had 0.18 ± 0.32 mm of bone loss, Group 2 (epicrestal with 2 mm healing abutment) had 0.51 ± 0.4 mm of bone loss, with statistically significant difference (P = .001). Bone remodeling in Group 1 (subcrestal) was 1.17 ± 0.51 mm. Vertical tissue thickness in epicrestal group before the intervention was 1.85 ± 0.26 and 3.65 ± 0.41 mm after the use of 2 mm healing abutment, with a statistical difference (P = .005). CONCLUSION: Subcrestal implant placement can significantly reduce crestal bone loss, compared to vertical soft tissue thickening by tenting of epicrestally placed implants, although soft tissue tenting can significantly increase soft tissue thickness.


Asunto(s)
Pérdida de Hueso Alveolar , Implantes Dentales , Pérdida de Hueso Alveolar/diagnóstico por imagen , Pérdida de Hueso Alveolar/etiología , Remodelación Ósea , Huesos , Implantación Dental Endoósea , Humanos
5.
Int J Prosthodont ; 33(2): 217-223, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32069347

RESUMEN

PURPOSE: To evaluate the surface roughness values of zirconium oxide samples that were gradually polished using a commercially available polishing system and polishing paste. MATERIALS AND METHODS: A total of 50 rectangular specimens of predetermined size (10 × 10 × 3 mm) were sintered from zirconium oxide. Samples were randomly assigned to one of five groups (n = 10 each): control, coarse (Co), fine (F), super fine (SF), or polishing paste (PP). In the control group, no polishing was done; in the Co group, a coarse polisher was used; and the specimens in the remaining three groups underwent additional processing with a fine rubber abrasive. For SF and PP samples, subsequent treatment with a super fine polisher was applied. Finally, for the PP group, a goat-hair brush with diamond polishing paste was used. An optical profilometer was used to evaluate roughness average (Ra) in micrometers (µm). ANOVA and Games-Howell post hoc tests were utilized to detect differences between groups. The significance level was set to α = .05. RESULTS: Surface roughness gradually decreased with further polishing throughout the groups: control Ra = 0.525 ± 0.099 µm; Co Ra = 0.252 ± 0.038 µm; F Ra = 0.196 ± 0.035 µm; SF Ra = 0.114 ± 0.031 µm; and PP Ra = 0.054 ± 0.020 µm. Statistically significant differences were detected among all groups (P < .05). CONCLUSION: A surface roughness of 0.054 µm can be achieved if a full zirconia polishing protocol is used. Zirconium oxide can be polished to various surface roughnesses using commercially available polishing products.


Asunto(s)
Pulido Dental , Circonio , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Propiedades de Superficie