Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 111
Filtrar
1.
Insights Imaging ; 15(1): 160, 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38913106

RESUMEN

OBJECTIVES: This systematic review and meta-analysis aimed to assess the stroke detection performance of artificial intelligence (AI) in magnetic resonance imaging (MRI), and additionally to identify reporting insufficiencies. METHODS: PRISMA guidelines were followed. MEDLINE, Embase, Cochrane Central, and IEEE Xplore were searched for studies utilising MRI and AI for stroke detection. The protocol was prospectively registered with PROSPERO (CRD42021289748). Sensitivity, specificity, accuracy, and area under the receiver operating characteristic (ROC) curve were the primary outcomes. Only studies using MRI in adults were included. The intervention was AI for stroke detection with ischaemic and haemorrhagic stroke in separate categories. Any manual labelling was used as a comparator. A modified QUADAS-2 tool was used for bias assessment. The minimum information about clinical artificial intelligence modelling (MI-CLAIM) checklist was used to assess reporting insufficiencies. Meta-analyses were performed for sensitivity, specificity, and hierarchical summary ROC (HSROC) on low risk of bias studies. RESULTS: Thirty-three studies were eligible for inclusion. Fifteen studies had a low risk of bias. Low-risk studies were better for reporting MI-CLAIM items. Only one study examined a CE-approved AI algorithm. Forest plots revealed detection sensitivity and specificity of 93% and 93% with identical performance in the HSROC analysis and positive and negative likelihood ratios of 12.6 and 0.079. CONCLUSION: Current AI technology can detect ischaemic stroke in MRI. There is a need for further validation of haemorrhagic detection. The clinical usability of AI stroke detection in MRI is yet to be investigated. CRITICAL RELEVANCE STATEMENT: This first meta-analysis concludes that AI, utilising diffusion-weighted MRI sequences, can accurately aid the detection of ischaemic brain lesions and its clinical utility is ready to be uncovered in clinical trials. KEY POINTS: There is a growing interest in AI solutions for detection aid. The performance is unknown for MRI stroke assessment. AI detection sensitivity and specificity were 93% and 93% for ischaemic lesions. There is limited evidence for the detection of patients with haemorrhagic lesions. AI can accurately detect patients with ischaemic stroke in MRI.

2.
Diagnostics (Basel) ; 14(12)2024 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-38928698

RESUMEN

Community-acquired pneumonia is a common cause of acute hospitalisation. Identifying patients with community-acquired pneumonia among patients suspected of having the disease can be a challenge, which causes unnecessary antibiotic treatment. We investigated whether the circulatory pulmonary injury markers surfactant protein D (SP-D), Krebs von den Lungen-6 (KL-6), and Club cell protein 16 (CC16) could help identify patients with community-acquired pneumonia upon acute admission. In this multi-centre diagnostic accuracy study, SP-D, KL-6, and CC16 were quantified in plasma samples from acutely hospitalised patients with provisional diagnoses of community-acquired pneumonia. The area under the receiver operator characteristics curve (AUC) was calculated for each marker against the following outcomes: patients' final diagnoses regarding community-acquired pneumonia assigned by an expert panel, and pneumonic findings on chest CTs. Plasma samples from 339 patients were analysed. The prevalence of community-acquired pneumonia was 63%. AUCs for each marker against both final diagnoses and chest CT diagnoses ranged between 0.50 and 0.56. Thus, SP-D, KL-6, and CC16 demonstrated poor diagnostic performance for community-acquired pneumonia in acutely hospitalised patients. Our findings indicate that the markers cannot readily assist physicians in confirming or ruling out community-acquired pneumonia.

3.
Cardiovasc Intervent Radiol ; 47(4): 453-461, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38483602

RESUMEN

PURPOSE: Endophytic renal cancer treatment is a challenge. Due to difficulties in endophytic tumor visualization during surgical extirpation, image-guided percutaneous cryoablation (PCA) is an attractive alternative. The minimally invasive nature of PCA makes it favorable for comorbid patients as well as patients in which surgery is contraindicated. Oncological outcomes and complications after PCA of endophytic biopsy-proven renal cell carcinoma (RCC) were reviewed in this study. MATERIALS AND METHODS: Patients were included after a multidisciplinary team conference from January 2015 to November 2021. Inclusion criteria were endophytic biopsy-proven T1 RCC treated with PCA with one year of follow-up. Complications were reported according to the Cardiovascular and Interventional Radiological Society of Europe (CIRSE) classification system and the Clavien-Dindo classification (CDC) system. Major complications were defined as a grade ≥ 3 according to the CDC. RESULTS: Fifty-six patients were included with a total of 56 endophytic tumors treated during 61 PCA sessions. The median RENAL nephrometry score was 9 (IQR 2), and the mean tumor size was 25.7 mm (SD ± 8.9 mm). Mean hospitalization time was 0.39 (SD ± 1.1) days. At a mean follow-up of 996 days (SD ± 559), 86% of tumors were recurrence free after one PCA. No patients progressed to metastatic disease. According to the CIRSE classification, 10.7% (n = 6) had grade 3 complications, and 5.4% (n = 3) had CDC major complications. CONCLUSION: This study demonstrates that PCA of endophytic biopsy-proven T1 RCC is safe with few major complications and excellent local tumor control rates at almost three-year mean follow-up. LEVEL OF EVIDENCE 3: Retrospective cohort study.


Asunto(s)
Carcinoma de Células Renales , Criocirugía , Neoplasias Renales , Humanos , Carcinoma de Células Renales/diagnóstico por imagen , Carcinoma de Células Renales/cirugía , Carcinoma de Células Renales/patología , Estudios Retrospectivos , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/cirugía , Neoplasias Renales/patología , Riñón/patología , Resultado del Tratamiento
4.
Cardiovasc Intervent Radiol ; 47(5): 583-589, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38273129

RESUMEN

PURPOSE: Treatment of renal cell carcinoma (RCC) in patients with solitary kidneys remains challenging. The purpose of this multicentre cohort study was to explore how renal function is affected by percutaneous image-guided cryoablation in patients with solitary kidneys. MATERIAL AND METHODS: Data from the European Registry for Renal Cryoablation database were extracted on patients with RCC in solitary kidneys treated with image-guided, percutaneous cryoablation. Patients were excluded if they had multiple tumours, had received previous treatment of the tumour, or were treated with more than one cryoablation procedure. Pre- and post-treatment eGFR (within 3 months of the procedure) were compared. RESULTS: Of 222 patients with solitary kidneys entered into the database, a total of 70 patients met inclusion criteria. The mean baseline eGFR was 55.8 ± 16.8 mL/min/1.73 m2, and the mean 3-month post-operative eGFR was 49.6 ± 16.5 mL/min/1.73 m2. Mean eGFR reduction was - 6.2 mL/min/1.73 m2 corresponding to 11.1% (p = 0.01). No patients changed chronic kidney disease group to severe or end-stage chronic kidney disease (stage IV or V). No patients required post-procedure dialysis. CONCLUSION: Image-guided renal cryoablation appears to be safe and effective for renal function preservation in patients with RCC in a solitary kidney. Following cryoablation, all patients had preservation of renal function without the need for dialysis or progression in chronic kidney disease stage despite the statistically significant reduction in eGFR. LEVEL OF EVIDENCE 3: Observational study.


Asunto(s)
Carcinoma de Células Renales , Criocirugía , Tasa de Filtración Glomerular , Neoplasias Renales , Sistema de Registros , Tomografía Computarizada por Rayos X , Humanos , Criocirugía/métodos , Neoplasias Renales/cirugía , Neoplasias Renales/diagnóstico por imagen , Masculino , Femenino , Anciano , Europa (Continente) , Carcinoma de Células Renales/cirugía , Carcinoma de Células Renales/diagnóstico por imagen , Estudios Prospectivos , Persona de Mediana Edad , Tomografía Computarizada por Rayos X/métodos , Riñón Único/cirugía , Riñón Único/complicaciones , Radiografía Intervencional/métodos , Resultado del Tratamiento , Riñón/cirugía , Riñón/diagnóstico por imagen , Riñón/anomalías , Cirugía Asistida por Computador/métodos
5.
Ultrasound Med Biol ; 50(2): 277-284, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38040522

RESUMEN

OBJECTIVE: Focused assessment with sonography for trauma (FAST) is a valuable ultrasound procedure in emergency settings, and there is a need for evidence-based education in FAST to ensure competencies. Immersive virtual reality (IVR) is a progressive training modality gaining traction in the field of ultrasound training. IVR holds several economic and practical advantages to the common instructor-led FAST courses using screen-based simulation (SBS). METHODS: This prospective, interventional cohort study investigated whether training FAST using IVR unsupervised and out-of-hospital was non-inferior to a historical control group training at a 90 min SBS course in terms of developing FAST competencies in novices. Competencies were assessed in both groups using the same post-training simulation-based FAST test with validity evidence, and a non-inferiority margin of 2 points was chosen. RESULTS: A total of 27 medical students attended the IVR course, and 27 junior doctors attended the SBS course. The IVR group trained for a median time of 117 min and scored a mean 14.2 ± 2.0 points, compared with a mean 13.7 ± 2.5 points in the SBS group. As the lower bound of the 95% confidence interval at 13.6 was within the range of the non-inferiority margin (11.7-13.7 points), training FAST in IVR for a median of 117 min was found non-inferior to training at a 90 min SBS course. No significant correlation was found between time spent in IVR and test scores. CONCLUSION: Within the limitations of the use of a historical control group, the results suggest that IVR could be an alternative to SBS FAST training and suitable for unsupervised, out-of-hospital courses in basic FAST competencies.


Asunto(s)
Evaluación Enfocada con Ecografía para Trauma , Realidad Virtual , Humanos , Estudios de Cohortes , Estudios Prospectivos , Ultrasonografía , Competencia Clínica
6.
Cancer Imaging ; 23(1): 127, 2023 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-38124111

RESUMEN

BACKGROUND: Artificial intelligence (AI) systems are proposed as a replacement of the first reader in double reading within mammography screening. We aimed to assess cancer detection accuracy of an AI system in a Danish screening population. METHODS: We retrieved a consecutive screening cohort from the Region of Southern Denmark including all participating women between Aug 4, 2014, and August 15, 2018. Screening mammograms were processed by a commercial AI system and detection accuracy was evaluated in two scenarios, Standalone AI and AI-integrated screening replacing first reader, with first reader and double reading with arbitration (combined reading) as comparators, respectively. Two AI-score cut-off points were applied by matching at mean first reader sensitivity (AIsens) and specificity (AIspec). Reference standard was histopathology-proven breast cancer or cancer-free follow-up within 24 months. Coprimary endpoints were sensitivity and specificity, and secondary endpoints were positive predictive value (PPV), negative predictive value (NPV), recall rate, and arbitration rate. Accuracy estimates were calculated using McNemar's test or exact binomial test. RESULTS: Out of 272,008 screening mammograms from 158,732 women, 257,671 (94.7%) with adequate image data were included in the final analyses. Sensitivity and specificity were 63.7% (95% CI 61.6%-65.8%) and 97.8% (97.7-97.8%) for first reader, and 73.9% (72.0-75.8%) and 97.9% (97.9-98.0%) for combined reading, respectively. Standalone AIsens showed a lower specificity (-1.3%) and PPV (-6.1%), and a higher recall rate (+ 1.3%) compared to first reader (p < 0.0001 for all), while Standalone AIspec had a lower sensitivity (-5.1%; p < 0.0001), PPV (-1.3%; p = 0.01) and NPV (-0.04%; p = 0.0002). Compared to combined reading, Integrated AIsens achieved higher sensitivity (+ 2.3%; p = 0.0004), but lower specificity (-0.6%) and PPV (-3.9%) as well as higher recall rate (+ 0.6%) and arbitration rate (+ 2.2%; p < 0.0001 for all). Integrated AIspec showed no significant difference in any outcome measures apart from a slightly higher arbitration rate (p < 0.0001). Subgroup analyses showed higher detection of interval cancers by Standalone AI and Integrated AI at both thresholds (p < 0.0001 for all) with a varying composition of detected cancers across multiple subgroups of tumour characteristics. CONCLUSIONS: Replacing first reader in double reading with an AI could be feasible but choosing an appropriate AI threshold is crucial to maintaining cancer detection accuracy and workload.


Asunto(s)
Neoplasias de la Mama , Femenino , Humanos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/epidemiología , Estudios Retrospectivos , Tamizaje Masivo/métodos , Inteligencia Artificial , Detección Precoz del Cáncer , Mamografía/métodos
7.
Eur Radiol ; 2023 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-37938386

RESUMEN

OBJECTIVES: To validate an AI system for standalone breast cancer detection on an entire screening population in comparison to first-reading breast radiologists. MATERIALS AND METHODS: All mammography screenings performed between August 4, 2014, and August 15, 2018, in the Region of Southern Denmark with follow-up within 24 months were eligible. Screenings were assessed as normal or abnormal by breast radiologists through double reading with arbitration. For an AI decision of normal or abnormal, two AI-score cut-off points were applied by matching at mean sensitivity (AIsens) and specificity (AIspec) of first readers. Accuracy measures were sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and recall rate (RR). RESULTS: The sample included 249,402 screenings (149,495 women) and 2033 breast cancers (72.6% screen-detected cancers, 27.4% interval cancers). AIsens had lower specificity (97.5% vs 97.7%; p < 0.0001) and PPV (17.5% vs 18.7%; p = 0.01) and a higher RR (3.0% vs 2.8%; p < 0.0001) than first readers. AIspec was comparable to first readers in terms of all accuracy measures. Both AIsens and AIspec detected significantly fewer screen-detected cancers (1166 (AIsens), 1156 (AIspec) vs 1252; p < 0.0001) but found more interval cancers compared to first readers (126 (AIsens), 117 (AIspec) vs 39; p < 0.0001) with varying types of cancers detected across multiple subgroups. CONCLUSION: Standalone AI can detect breast cancer at an accuracy level equivalent to the standard of first readers when the AI threshold point was matched at first reader specificity. However, AI and first readers detected a different composition of cancers. CLINICAL RELEVANCE STATEMENT: Replacing first readers with AI with an appropriate cut-off score could be feasible. AI-detected cancers not detected by radiologists suggest a potential increase in the number of cancers detected if AI is implemented to support double reading within screening, although the clinicopathological characteristics of detected cancers would not change significantly. KEY POINTS: • Standalone AI cancer detection was compared to first readers in a double-read mammography screening population. • Standalone AI matched at first reader specificity showed no statistically significant difference in overall accuracy but detected different cancers. • With an appropriate threshold, AI-integrated screening can increase the number of detected cancers with similar clinicopathological characteristics.

8.
Eur J Radiol ; 168: 111126, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37804650

RESUMEN

PURPOSE: To estimate the ability of a commercially available artificial intelligence (AI) tool to detect acute brain ischemia on Magnetic Resonance Imaging (MRI), compared to an experienced neuroradiologist. METHODS: We retrospectively included 1030 patients with brain MRI, suspected of stroke from January 6th, 2020 to 1st of April 2022, based on these criteria: Age ≥ 18 years, symptoms within four weeks before the scan. The neuroradiologist reinterpreted the MRI scans and subclassified ischemic lesions for reference. We excluded scans with interpretation difficulties due to artifacts or missing sequences. Four MRI scanner models from the same vendor were used. The first 800 patients were included consecutively, remaining enriched for less frequent lesions. The index test was a CE-approved AI tool (Apollo version 2.1.1 by Cerebriu). RESULTS: The final analysis cohort comprised 995 patients (mean age 69 years, 53 % female). A case-based analysis for detecting acute ischemic lesions showed a sensitivity of 89 % (95 % CI: 85 %-91 %) and specificity of 90 % (95 % CI: 87 %-92 %). We found no significant difference in sensitivity or specificity based on sex, age, or comorbidities. Specificity was reduced in cases with DWI artifacts. Multivariate analysis showed that increasing ischemic lesion size and fragmented lesions were independently associated with higher sensitivity, while non-acute lesion ages lowered sensitivity. CONCLUSIONS: The AI tool exhibits high sensitivity and specificity in detecting acute ischemic lesions on MRI compared to an experienced neuroradiologist. While sensitivity depends on the ischemic lesions' characteristics, specificity depends on the image quality.


Asunto(s)
Isquemia Encefálica , Aprendizaje Profundo , Accidente Cerebrovascular , Humanos , Femenino , Anciano , Adolescente , Masculino , Estudios Retrospectivos , Inteligencia Artificial , Accidente Cerebrovascular/patología , Imagen por Resonancia Magnética/métodos , Isquemia Encefálica/diagnóstico por imagen , Isquemia Encefálica/patología , Encéfalo/patología , Algoritmos , Pruebas Diagnósticas de Rutina , Imagen de Difusión por Resonancia Magnética/métodos
9.
BMJ Open ; 13(10): e077702, 2023 10 17.
Artículo en Inglés | MEDLINE | ID: mdl-37848298

RESUMEN

OBJECTIVE: The implementation of point-of-care ultrasound (POCUS) in general practice varies, but it is unknown what determines this variation. The purpose of this study was to explore (1) the overall proportion of POCUS-users among general practitioners (GPs), (2) the current use of POCUS by GPs, (3) factors related to the implementation of POCUS in general practice and (4) GPs' concerns related to POCUS use in general practice. DESIGN: An online survey was distributed in June 2019. SETTING: General practice. PARTICIPANTS: GPs working in office-based primary care clinics in Denmark. MAIN OUTCOME MEASURES: The questionnaire was developed using mixed methods and included questions about participants' characteristics, past POCUS training and experience, capability, opportunity and motivation for using POCUS in the primary care setting. Results were summarised using descriptive statistics. Association between GPs' background characteristics and POCUS use was tested using logistics regression. RESULTS: Responses were analysed from 1216 questionnaires corresponding to 36.4% of all GPs in Denmark. The majority (72.3%) of participants had previous POCUS experience, 14.7% had access to a POCUS device and 11.5% used POCUS. Several factors motivated participants to use POCUS. However, barriers existed such as lack of remuneration and high workload. Additionally, many GPs questioned their ability to scan with sufficient diagnostic accuracy and the impact of POCUS on the consultation. Of non-users, 28.7% believed they would be using POCUS in the future. CONCLUSION: Although, the majority of GPs had past experience with POCUS and felt motivated to use it, few had implemented POCUS. Several factors influenced the GPs' capability, opportunity and motivation for using POCUS and several concerns were registered by non-users.


Asunto(s)
Medicina General , Médicos Generales , Humanos , Sistemas de Atención de Punto , Encuestas y Cuestionarios , Ultrasonografía/métodos , Dinamarca , Atención Primaria de Salud
10.
BMJ Case Rep ; 16(10)2023 Oct 19.
Artículo en Inglés | MEDLINE | ID: mdl-37857535

RESUMEN

This case presents CT-guided percutaneous cryoablation as a treatment option in a patient with oligometastatic breast cancer who previously had received standard-of-care treatment for metastatic breast cancer. Before cryoablation, the patient received two systemic lines of therapy, several surgeries and radiotherapy for oligometastatic disease. The cryoablation was performed in a single 7 mm subpleural oligometastatic lesion 42 months after diagnosis of metastatic breast cancer. It was performed without complications, and the patient experienced no complaints or discomfort after the procedure. A 3-month, 6-month, 9-month and 12-month follow-up fluorodeoxyglucose-positron emission tomography/CT scans showed no sign of disease progression.


Asunto(s)
Neoplasias de la Mama , Criocirugía , Humanos , Femenino , Neoplasias de la Mama/cirugía , Neoplasias de la Mama/patología , Criocirugía/métodos , Resultado del Tratamiento , Tomografía Computarizada por Rayos X , Tomografía de Emisión de Positrones , Estudios Retrospectivos
11.
BMC Infect Dis ; 23(1): 580, 2023 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-37670282

RESUMEN

BACKGROUND: Many factors determine empirical antibiotic treatment of community-acquired pneumonia (CAP). We aimed to describe the empirical antibiotic treatment CAP patients with an acute hospital visit and to determine if the current treatment algorithm provided specific and sufficient coverage against Legionella pneumophila, Mycoplasma pneumoniae, and Clamydophila pneumoniae (LMC). METHODS: A descriptive cross-sectional, multicenter study of all adults with an acute hospital visit in the Region of Southern Denmark between January 2016 and March 2018 was performed. Using medical records, we retrospectively identified the empirical antibiotic treatment and the microbiological etiology for CAP patients. CAP patients who were prescribed antibiotics within 24 h of admission and with an identified bacterial pathogen were included. The prescribed empirical antibiotic treatment and its ability to provide specific and sufficient coverage against LMC pneumonia were determined. RESULTS: Of the 19,133 patients diagnosed with CAP, 1590 (8.3%) patients were included in this study. Piperacillin-tazobactam and Beta-lactamase sensitive penicillins were the most commonly prescribed empirical treatments, 515 (32%) and 388 (24%), respectively. Our analysis showed that 42 (37%, 95% CI: 28-47%) of 113 patients with LMC pneumonia were prescribed antibiotics with LMC coverage, and 42 (12%, 95% CI: 8-15%) of 364 patients prescribed antibiotics with LMC coverage had LMC pneumonia. CONCLUSION: Piperacillin-tazobactam, a broad-spectrum antibiotic recommended for uncertain infectious focus, was the most frequent CAP treatment and prescribed to every third patient. In addition, the current empirical antibiotic treatment accuracy was low for LMC pneumonia. Therefore, future research should focus on faster diagnostic tools for identifying the infection focus and precise microbiological testing.


Asunto(s)
Infecciones Comunitarias Adquiridas , Legionella pneumophila , Neumonía , Humanos , Adulto , Mycoplasma pneumoniae , Estudios Transversales , Estudios Retrospectivos , Antibacterianos , Combinación Piperacilina y Tazobactam , Servicio de Urgencia en Hospital
12.
Acta Radiol Open ; 12(9): 20584601231205986, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37767057

RESUMEN

Background: Management of the distal radius fracture (DRF) is to some extent based on radiographic characterization of fracture displacement. It remains unclear, however, if the measurements used to quantify displacement are accurate. Purpose: To quantify accuracy of two radiographic measurements: dorsal/volar tilt and fracture compression, measured indirectly as ulnar variance (UV), using radiostereometric analyses (RSA) as reference standard. Material and Methods: Twenty-one fresh frozen non-fractured human cadaveric forearms (right = 11, left = 10) were thawed and eligible for inclusion. The forearms were mounted on a custom made platform that allowed for controlled forearm rotation, and they underwent two rounds of imaging (both rounds consisted of RSA and radiographs). In round one, the non-fractured forearms were radiographed. In round two, artificial DRF´s with compression and dorsal angulation were created and imaging procedures repeated. Change in tilt and UV between the non-fractured and later fractured forearms was defined as fracture-induced deformity. Deformity was measured radiographically and additionally calculated using RSA. Bland Altman analyses were used to estimate agreement between radiographically measured, and RSA calculated, fracture-induced deformity. Results: Our results indicated that radiographs underestimate the amount of fracture-induced deformity. Mean measured differences (bias) in dorsal tilt deformity between radiographs and RSA were -2.5° for both observers. The corresponding values for UV were -1.4 mm and -1.5 mm. Conclusion: Quantifying fracture-induced deformity on radiographs underestimated the actual deformity when compared to RSA calculated deformity. These findings suggest that clinicians, at least in part, base fracture management and potentially corrective surgery on inaccurate measurements.

13.
J Clin Imaging Sci ; 13: 20, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37559875

RESUMEN

Objectives: Using virtual reality (VR), students of radiography can practice acquisition and positioning of musculoskeletal radiographs and get immediate feedback on their performance within the simulator. The purpose of this study was to assess usability of a newly developed VR simulator and to explore self-perceived clinical readiness (SPCR) of radiography students before and after training acquisition of wrist radiographs in the VR simulator. Material and Methods: A prospective methodology was applied where the students (n = 10) estimated their own SPCR in regard to acquisition of wrist radiographs pre- and post-VR training. A questionnaire on usability, realism, and educational value of the simulator was answered post-VR training. Usability and SPCR scores were calculated. The student's paired t-test was applied to explore the impact of VR training on SPCR. Results: The students (90%) reported that the simulator was realistic and they thought that it could contribute to learning. The pre- and post-SPCR scores were 75 (95% confidence interval [CI]: 54-96) and 77 (95% CI: 59-95), respectively. There was no significant difference (P = 0.4574) between the pre- and post-SPCR scores. Conclusion: Results indicated that the concept of training acquisition and positioning of wrist radiographs in a VR simulator is feasible with positive feedback from the students. The SPCR scores improved slightly, although not statistically significant, after completion of the training session.

14.
Acta Radiol Open ; 12(3): 20584601231183900, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37546523

RESUMEN

Background: In suspected community-acquired pneumonia (CAP), chest CT is superior to the routinely obtained radiographs (CXR), but administers higher radiation doses. However, ultra-low-dose CT (ULDCT) has shown promising results. Purpose: To compare radiation dose and image quality using standard and ULDCT protocols designed for a multicenter study encompassing three CT scanner models from GE, Canon, and Siemens. Material and methods: Patients with suspected CAP were referred for non-contrast standard dose chest CT (NCCT) and ULDCT. Effective radiation dose and Contrast-to-Noise Ratio (CNR) was calculated. Results: Mean effective doses were GE (n = 10) 6.93 mSv in NCCT and 0.27 mSv in ULDCT; Canon (n = 9) 3.48 in mSv NCCT and 1.11 mSv in ULDCT; Siemens (n = 10) 2.85 mSv in NCCT and 0.45 mSv in ULDCT. CNR was reduced by 29-39% in ULDCT. Conclusion: The proposed CT protocols yielded dose reductions of 96%, 68%, and 84% using a GE, Canon, and Siemens scanner, respectively.

15.
J Endourol ; 37(10): 1149-1155, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37578120

RESUMEN

Background: Percutaneous cryoablation (PCA) of renal tumors is a well-established alternative to partial nephrectomy, but the effects on renal function after the procedure are not well-documented. The purpose of this study was to evaluate renal function after computed tomography-guided PCA. Materials and Methods: A retrospective cohort study including 259 patients treated with PCA at Odense University Hospital, Denmark from January 1, 2015 to December 31, 2019. Both patients with malignant (96%) and benign tumors (4%) were included. Mean age of patients was 66.5 years (standard deviation [SD] = 10.9, range: 27-91) and 174 (67%) patients were men. Baseline estimated glomerular filtration rate (eGFR) was recorded at baseline and 12 months after cryoablation. Results: Mean tumor size was 27.5 mm (SD = 10.0) distributed in seven different histopathological types, mainly clear cell renal-cell carcinoma (RCC) (64%) and papillary RCC (22%). Mean eGFR at baseline was 73.7 mL/min/1.73 m2 (SD = 23.2) with a follow-up mean eGFR of 69.7 (SD = 23.7) (p < 0.0001). At baseline before intervention 190 patients (73%) had eGFR matching chronic kidney disease (CKD) groups 1 and 2 (normal to mild CKD), 64 patients (24%) matching CKD group 3 (average CKD), and 1% in groups 4 and 5. At 12-month follow-up, 171 patients (66%) had eGFR matching CKD groups 1 and 2, 77 patients (30%) matching CKD group 3 and 11 patients (4%) matching CKD groups 4 and 5. In patients with skewed renography who had PCA in the kidney with better excretion, eGFR at baseline was 64.7 and 61.2 at follow-up (p = 0.703). Conclusions: This study showed minimal decline in renal function 12 months after PCA, even for patients with reduced renal function. PCA is therefore considered a safe and relevant intervention.

16.
Cancers (Basel) ; 15(13)2023 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-37444432

RESUMEN

This study aims to evaluate the safety, efficacy, and renal function preservation of percutaneous cryoablation (PCA) for small renal masses (SRMs) in inherited RCC syndromes. Patients with inherited T1N0M0 RCCs (<7 cm) undergoing PCA from 2015 to 2021 were identified from the European Registry for Renal Cryoablation (EuRECA). The primary outcome was local recurrence-free survival (LRFS). The secondary outcomes included technical success, peri-operative outcomes, and other oncological outcomes estimated using the Kaplan-Meier method. Simple proportions, chi-squared tests, and t-tests were used to analyse the peri-operative outcomes. A total of 68 sessions of PCA were performed in 53 patients with RCC and 85 tumours were followed-up for a mean duration of 30.4 months (SD ± 22.0). The overall technical success rate was 99%. The major post-operative complication rate was 1.7%. In total, 7.4% (2/27) of patients had >25% reduction in renal function. All oncological events were observed in VHL patients. Estimated 5-year LRFS, metastasis-free survival, cancer-specific survival, and overall survival were 96.0% (95% CI 75-99%), 96.4% (95% CI 77-99%), 90.9% (95% CI 51-99%), and 90.9% (95% CI 51-99%), respectively. PCA of RCCs for patients with hereditary RCC SRMs appears to be safe, offers low complication rates, preserves renal function, and achieves good oncological outcomes.

17.
Urol Case Rep ; 49: 102450, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37288320

RESUMEN

A 67-year-old female patient was diagnosed with bilateral renal metastases from adenoid cystic carcinoma (AdCC) of salivary gland origin five years after the primary diagnosis of minor salivary gland AdCC. Bilateral renal core needle biopsies were performed to distinguish primary renal cell carcinoma (RCC) from metastases and to guide treatment strategy. Few similar cases have been reported; none had bilateral metastases at the time of discovery or biopsy-verified AdCC metastases prior to the treatment decision. RCC was a tentative diagnosis and renal metastases of AdCC have previously been mistaken for RCC.

18.
Acta Radiol Open ; 12(4): 20584601231167146, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37101460

RESUMEN

Background: Dorsal/volar tilt is an important radiographic measurement commonly included in the treatment decision of distal radius fractures (DRFs). However, studies have shown that forearm positioning relative to rotation (i.e., supination and pronation) can affect the measured tilt value but with substantial interobserver variance. Purpose: To examine whether interobserver agreement on radiographic tilt measurement is influenced by forearm rotation. Material and Methods: We radiographed 21 cadaveric forearms at 5° rotational intervals between 15° supination and 15° pronation on lateral radiographs. A radiologist and a hand surgeon measured tilt in a blinded and randomized fashion. Bland-Altman analyses with bias and limits of agreement (LoA) were used to estimate interobserver agreement for forearms in all degrees of rotation, non-rotated forearms, supinated forearms, and pronated forearms. Results: Interobserver agreement varied with forearm rotation. Bias (95% confidence interval [CI]; LoA) was -1.54° (95% CI: -2.53, -0.55; LoA: -13.46, 10.38) when measuring tilt on radiographs with all degrees of forearm rotation, and -1.48° (95% CI: -4.13, 1.17; LoA: -12.88, 9.92) when measuring tilt on true lateral 0° radiographs. When measuring on supinated and pronated radiographs, bias was -0.03° (95% CI: -1.35, 1.29; LoA: -8.34, 8.28) and -3.23° (95% CI: -5.41, -1.06; LoA: -16.90, 10.44), respectively. Conclusion: Interobserver agreement on tilt was similar when comparing measurements made on true lateral radiographs to those made on the group with all degrees of forearm rotation. However, interobserver agreement improved with supination and worsened with pronation.

19.
JAMA Otolaryngol Head Neck Surg ; 149(6): 531-539, 2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-37052913

RESUMEN

Importance: Scintigraphy and ultrasonography are common imaging modalities for the preoperative localization of enlarged parathyroid glands in primary hyperparathyroidism. When comparing the 2 modalities, the benefits of ultrasonography in terms of convenience, patient comfort, duration, cost, and lack of radiation should be taken into account. Objective: To investigate whether surgeon-performed ultrasonography, with or without contrast-enhanced ultrasonography (CEUS), is noninferior to scintigraphy for localizing pathological parathyroid glands in patients with primary hyperparathyroidism. Design, Setting, and Participants: Prospective, paired, noninferiority cohort study performed at a high-volume tertiary referral center for parathyroidectomy with blinded examiners and a 6-month follow-up. Participants were adults (age ≥18 years) referred for parathyroidectomy due to primary hyperparathyroidism. Of 207 eligible patients, 35 were excluded, leaving 172 enrolled in the study. Inclusion lasted from September 2019 until February 2021. Follow-up ended in December 2021. Exposures: 99mTechnetium-pertechnetate/99mtechnetium-sestamibi subtraction scintigraphy with 99mtechnetium-sestamibi single-photon emission computed tomography/computed tomography, followed by surgeon-performed ultrasonography and CEUS. Main Outcomes and Measures: The sensitivity of each imaging modality in localizing pathological parathyroid glands, calculated on a per-quadrant and a per-patient basis, respectively. The a priori noninferiority margin was a lower 95% confidence limit for the difference in sensitivity not falling below -10%. Results: Out of 172 participants, 139 (80.8%) were women, the median (range) age was 65 (24-87) years, and the median (IQR) follow-up was 200.5 (181-280.25) days. Quadrant sensitivity (95% CI) was 70.9% (63.2%-78.5%) for ultrasonography, 68.4% (60.4%-76.5%) for ultrasonography plus CEUS, and 67.0% (60.0%-74.0%) for scintigraphy. The sensitivity difference (95% CI) compared with scintigraphy was 3.9% (-4.1% to 11.8%) for ultrasonography and 1.5% (-6.4% to 9.3%) for ultrasonography plus CEUS, establishing noninferiority for both modalities. Per-patient sensitivity was 81.4% (74.8%-86.9%) for ultrasonography and 79.1% (72.2%-84.9%) for both scintigraphy and ultrasonography plus CEUS. The sensitivity difference compared with scintigraphy was 2.3% (-6.8% to 11.4%) for ultrasonography and 0.0% (-9.1% to 9.1%) for ultrasonography plus CEUS, establishing noninferiority for both modalities. Conclusions and Relevance: In this cohort study, conventional ultrasonography by an experienced parathyroid surgeon-sonographer was noninferior to scintigraphy and may constitute a valid first-line imaging modality in patients with primary hyperparathyroidism, even without the addition of CEUS. Further imaging should be reserved for cases that are equivocal or nonlocalizing on ultrasonography.


Asunto(s)
Hiperparatiroidismo Primario , Cirujanos , Adulto , Humanos , Femenino , Adolescente , Anciano , Anciano de 80 o más Años , Masculino , Hiperparatiroidismo Primario/diagnóstico por imagen , Hiperparatiroidismo Primario/cirugía , Estudios de Cohortes , Estudios Prospectivos , Tecnecio Tc 99m Sestamibi , Cintigrafía , Glándulas Paratiroides/diagnóstico por imagen , Ultrasonografía/métodos , Paratiroidectomía , Sensibilidad y Especificidad
20.
Neurology ; 100(10): e1048-e1061, 2023 03 07.
Artículo en Inglés | MEDLINE | ID: mdl-36878720

RESUMEN

BACKGROUND AND OBJECTIVES: A causal relationship between statin use and intracerebral hemorrhage (ICH) is uncertain. We hypothesized that an association between long-term statin exposure and ICH risk might vary for different ICH locations. METHODS: We conducted this analysis using linked Danish nationwide registries. Within the Southern Denmark Region (population 1.2 million), we identified all first-ever cases of ICH between 2009 and 2018 in persons aged ≥55 years. Patients with medical record-verified diagnoses were classified as having a lobar or nonlobar ICH and matched for age, sex, and calendar year to general population controls. We used a nationwide prescription registry to ascertain prior statin and other medication use that we classified for recency, duration, and intensity. Using conditional logistic regression adjusted for potential confounders, we calculated adjusted ORs (aORs) and corresponding 95% CIs for the risk of lobar and nonlobar ICH. RESULTS: We identified 989 patients with lobar ICH (52.2% women, mean age 76.3 years) who we matched to 39,500 controls and 1,175 patients with nonlobar ICH (46.5% women, mean age 75.1 years) who we matched to 46,755 controls. Current statin use was associated with a lower risk of lobar (aOR 0.83; 95% CI, 0.70-0.98) and nonlobar ICH (aOR 0.84; 95% CI, 0.72-0.98). Longer duration of statin use was also associated with a lower risk of lobar (<1 year: aOR 0.89; 95% CI, 0.69-1.14; ≥1 year to <5 years aOR 0.89; 95% CI 0.73-1.09; ≥5 years aOR 0.67; 95% CI, 0.51-0.87; p for trend 0.040) and nonlobar ICH (<1 year: aOR 1.00; 95% CI, 0.80-1.25; ≥1 year to <5 years aOR 0.88; 95% CI 0.73-1.06; ≥5 years aOR 0.62; 95% CI, 0.48-0.80; p for trend <0.001). Estimates stratified by statin intensity were similar to the main estimates for low-medium intensity therapy (lobar aOR 0.82; nonlobar aOR 0.84); the association with high-intensity therapy was neutral. DISCUSSION: We found that statin use was associated with a lower risk of ICH, particularly with longer treatment duration. This association did not vary by hematoma location.


Asunto(s)
Inhibidores de Hidroximetilglutaril-CoA Reductasas , Humanos , Femenino , Anciano , Masculino , Inhibidores de Hidroximetilglutaril-CoA Reductasas/efectos adversos , Sistema de Registros , Estudios de Casos y Controles , Hemorragia Cerebral/inducido químicamente , Hemorragia Cerebral/epidemiología , Duración de la Terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA