Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
Adv Healthc Mater ; 12(29): e2301944, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37565378

RESUMEN

Porous tissue-engineered 3D-printed scaffolds are a compelling alternative to autografts for the treatment of large periorbital bone defects. Matching the defect-specific geometry has long been considered an optimal strategy to restore pre-injury anatomy. However, studies in large animal models have revealed that biomaterial-induced bone formation largely occurs around the scaffold periphery. Such ectopic bone formation in the periorbital region can affect vision and cause disfigurement. To enhance anatomic reconstruction, geometric mismatches are introduced in the scaffolds used to treat full thickness zygomatic defects created bilaterally in adult Yucatan minipigs. 3D-printed, anatomically-mirrored scaffolds are used in combination with autologous stromal vascular fraction of cells (SVF) for treatment. An advanced image-registration workflow is developed to quantify the post-surgical geometric mismatch and correlate it with the spatial pattern of the regenerating bone. Osteoconductive bone growth on the dorsal and ventral aspect of the defect enhances scaffold integration with the native bone while medio-lateral bone growth leads to failure of the scaffolds to integrate. A strong positive correlation is found between geometric mismatch and orthotopic bone deposition at the defect site. The data suggest that strategic mismatch >20% could improve bone scaffold design to promote enhanced regeneration, osseointegration, and long-term scaffold survivability.


Asunto(s)
Impresión Tridimensional , Andamios del Tejido , Porcinos , Animales , Porcinos Enanos , Materiales Biocompatibles/farmacología , Regeneración Ósea , Osteogénesis
2.
Biomaterials ; 282: 121392, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35134701

RESUMEN

Critical-sized midfacial bone defects present a unique clinical challenge due to their complex three-dimensional shapes and intimate associations with sensory organs. To address this challenge, a point-of-care treatment strategy for functional, long-term regeneration of 2 cm full-thickness segmental defects in the zygomatic arches of Yucatan minipigs is evaluated. A digital workflow is used to 3D-print anatomically precise, porous, biodegradable scaffolds from clinical-grade poly-ε-caprolactone and decellularized bone composites. The autologous stromal vascular fraction of cells (SVF) is isolated from adipose tissue extracts and infused into the scaffolds that are implanted into the zygomatic ostectomies. Bone regeneration is assessed up to 52 weeks post-operatively in acellular (AC) and SVF groups (BV/DV = 0.64 ± 0.10 and 0.65 ± 0.10 respectively). In both treated groups, bone grows from the adjacent tissues and restores the native anatomy. Significantly higher torque is required to fracture the bone-scaffold interface in the SVF (7.11 ± 2.31 N m) compared to AC groups (2.83 ± 0.23 N m). Three-dimensional microcomputed tomography analysis reveals two distinct regenerative patterns: osteoconduction along the periphery of scaffolds to form dense lamellar bone and small islands of woven bone deposits growing along the struts in the scaffold interior. Overall, this study validates the efficacy of using 3D-printed bioactive scaffolds with autologous SVF to restore geometrically complex midfacial bone defects of clinically relevant sizes while also highlighting remaining challenges to be addressed prior to clinical translation.


Asunto(s)
Fracción Vascular Estromal , Andamios del Tejido , Animales , Regeneración Ósea , Osteogénesis , Sistemas de Atención de Punto , Impresión Tridimensional , Porcinos , Porcinos Enanos , Microtomografía por Rayos X
3.
Science ; 360(6392): 992-997, 2018 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-29853681

RESUMEN

The surface of Pluto is more geologically diverse and dynamic than had been expected, but the role of its tenuous atmosphere in shaping the landscape remains unclear. We describe observations from the New Horizons spacecraft of regularly spaced, linear ridges whose morphology, distribution, and orientation are consistent with being transverse dunes. These are located close to mountainous regions and are orthogonal to nearby wind streaks. We demonstrate that the wavelength of the dunes (~0.4 to 1 kilometer) is best explained by the deposition of sand-sized (~200 to ~300 micrometer) particles of methane ice in moderate winds (<10 meters per second). The undisturbed morphology of the dunes, and relationships with the underlying convective glacial ice, imply that the dunes have formed in the very recent geological past.

4.
Science ; 351(6279): 1284-93, 2016 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-26989245

RESUMEN

NASA's New Horizons spacecraft has revealed the complex geology of Pluto and Charon. Pluto's encounter hemisphere shows ongoing surface geological activity centered on a vast basin containing a thick layer of volatile ices that appears to be involved in convection and advection, with a crater retention age no greater than ~10 million years. Surrounding terrains show active glacial flow, apparent transport and rotation of large buoyant water-ice crustal blocks, and pitting, the latter likely caused by sublimation erosion and/or collapse. More enigmatic features include tall mounds with central depressions that are conceivably cryovolcanic and ridges with complex bladed textures. Pluto also has ancient cratered terrains up to ~4 billion years old that are extensionally faulted and extensively mantled and perhaps eroded by glacial or other processes. Charon does not appear to be currently active, but experienced major extensional tectonism and resurfacing (probably cryovolcanic) nearly 4 billion years ago. Impact crater populations on Pluto and Charon are not consistent with the steepest impactor size-frequency distributions proposed for the Kuiper belt.

5.
Transl Res ; 162(6): 381-9, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23911638

RESUMEN

Catheter-based renal artery denervation has demonstrated to be effective in decreasing blood pressure among patients with refractory hypertension. The anatomic distribution of renal artery nerves may influence the safety and efficacy profile of this procedure. We aimed to describe the anatomic distribution and density of periarterial renal nerves in the porcine model. Thirty arterial renal sections were included in the analysis by harvesting a tissue block containing the renal arteries and perirenal tissue from each animal. Each artery was divided into 3 segments (proximal, mid, and distal) and assessed for total number, size, and depth of the nerves according to the location. Nerve counts were greatest proximally (45.62% of the total nerves) and decreased gradually distally (mid, 24.58%; distal, 29.79%). The distribution in nerve size was similar across all 3 sections (∼40% of the nerves, 50-100 µm; ∼30%, 0-50 µm; ∼20%, 100-200 µm; and ∼10%, 200-500 µm). In the arterial segments ∼45% of the nerves were located within 2 mm from the arterial wall whereas ∼52% of all nerves were located within 2.5 mm from the arterial wall. Sympathetic efferent fibers outnumbered sensory afferent fibers overwhelmingly, intermixed within the nerve bundle. In the porcine model, renal artery nerves are seen more frequently in the proximal segment of the artery. Nerve size distribution appears to be homogeneous throughout the artery length. Nerve bundles progress closer to the arterial wall in the distal segments of the artery. This anatomic distribution may have implications for the future development of renal denervation therapies.


Asunto(s)
Ablación por Catéter/métodos , Arteria Renal/inervación , Sus scrofa/anatomía & histología , Simpatectomía/métodos , Animales , Humanos , Hipertensión/terapia , Riñón/inervación , Modelos Anatómicos , Modelos Animales , Modelos Neurológicos , Sistema Nervioso Simpático/anatomía & histología , Investigación Biomédica Traslacional
6.
Appl Opt ; 43(9): 1926-37, 2004 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-15065723

RESUMEN

We have developed a spectrogonio radiometer to measure in the laboratory (-35 degrees C to +30 degrees C) the bidirectional reflectance and polarization distribution functions of various types of planetary material from the UV to the near-IR (310-4800 nm). The major, to our knowledge, novel feature of this instrument is that it is capable of measuring dark to translucent materials with a high degree of radiometric accuracy under most viewing geometries. The sample surface is illuminated with a large monochromatic and polarized parallel beam (incidence: 0 degrees-90 degrees ), and the total intensity and the two polarized components of the reflected light are measured (observation, 0 degrees-80 degrees; azimuth, 0 degrees-180 degrees). The scientific and technical constraints, the design, and the performances and limitations of the system are presented in this first paper.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA