Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Sensors (Basel) ; 24(13)2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-39001164

RESUMEN

Hyperspectral detection of the change rate of organic matter content in agricultural remote sensing requires a high signal-to-noise ratio (SNR). However, due to the large number and efficiency limitation of the components, it is difficult to improve the SNR. This study uses high-efficiency convex grating with a diffraction efficiency exceeding 50% across the 360-850 nm range, a back-illuminated Complementary Metal Oxide Semiconductor (CMOS) detector with a 95% efficiency in peak wavelength, and silver-coated mirrors to develop an imaging spectrometer for detecting soil organic matter (SOM). The designed system meets the spectral resolution of 10 nm in the 360-850 nm range and achieves a swath of 100 km and a spatial resolution of 100 m at an orbital height of 648.2 km. This study also uses the basic structure of Offner with fewer components in the design and sets the mirrors of the Offner structure to have the same sphere, which can achieve the rapid adjustment of the co-standard. This study performs a theoretical analysis of the developed Offner imaging spectrometer based on the classical Rowland circular structure, with a 21.8 mm slit length; simulates its capacity for suppressing the +2nd-order diffraction stray light with the filter; and analyzes the imaging quality after meeting the tolerance requirements, which is combined with the surface shape characteristics of the high-efficiency grating. After this test, the grating has a diffraction efficiency above 50%, and the silver-coated mirrors have a reflection value above 95% on average. Finally, the laboratory tests show that the SNR over the waveband exceeds 300 and reaches 800 at 550 nm, which is higher than some current instruments in orbit for soil observation. The proposed imaging spectrometer has a spectral resolution of 10 nm, and its modulation transfer function (MTF) is greater than 0.23 at the Nyquist frequency, making it suitable for remote sensing observation of SOM change rate. The manufacture of such a high-efficiency broadband grating and the development of the proposed instrument with high energy transmission efficiency can provide a feasible technical solution for observing faint targets with a high SNR.

2.
Opt Express ; 32(7): 11774-11793, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38571017

RESUMEN

The imaging spectrometer's high performance in practical applications may be compromised by environmental factors, particularly temperature variations, posing a challenge to its stability. Temperature fluctuations can induce spectral shift, directly impacting the accuracy of spectral measurements, subsequently influencing the precision of radiometric measurements. To address this issue, this study investigates a dual-channel UV imaging spectrometer. This instrument boasts a wavelength calibration accuracy of 0.01 nm. This paper conducts an in-depth analysis of the various mechanisms through which temperature changes influence the spectral line offset in the imaging spectrometer, integrating actual orbital temperature data to discuss the instrument's temperature load settings. The impact of temperature on spectral shift is examined using finite element analysis and optical design software. Estimations of spectral shift were made based on temperature variations. Simulation results indicated that the maximum deviation of spectral shift is estimated at 0.018 nm under a temperature condition of 16 ± 1°C. Under a more controlled orbital temperature condition (16 ± 0.3°C), the maximum deviation of spectral shift decreased to 0.01 nm. Experimental data revealed that at 16 ± 1°C, the maximum deviation of spectral shift did not exceed 0.01 nm. This effectively corroborates our theoretical analysis. The relationship between temperature and spectral shift offers a crucial theoretical foundation for calibrating spectral measurements and managing the thermal conditions of the instrument.

3.
Opt Express ; 31(21): 35054-35067, 2023 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-37859246

RESUMEN

Immersion gratings have high dispersion efficiency and have important application value in miniaturized imaging spectrometers, but its serious dispersion nonlinearity causes difficulties in calibration and image processing, which limits its application range. To solve this, this paper presents a design method for a two-material linear dispersion immersion grating device design method, and a compact small F-number immersion grating spectrometer based on it. First the vector form dispersion equation of the two-material immersion grating is derived and the linear spectral dispersion immersion grating design process is given, then a compact small F-number uniform dispersion imaging spectrometer is given as a design example using the proposed method. The results show that when the operating band of the system is 1590-1675 nm, the spectral resolution is better than 0.25 nm, and F-number can achieve better than 2. Compared with traditional single-material immersion grating imaging spectrometer, the designed imaging spectrometer dispersion linearity is significantly improved. Finally, the influence of prism materials, structure parameters and grating parameters on dispersion nonlinearity is analyzed. Design and analysis results show that the proposed two-material immersion grating device has much better spectral dispersion nonlinearity correction ability, and its design method can provide reference to the compact spectrometer design based on immersion gratings.

4.
Materials (Basel) ; 16(20)2023 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-37895633

RESUMEN

There are multiple routes to prepare semi-solid slurries with a globular microstructure for semi-solid forming. The variations in the microstructure of semi-solid slurries prepared using different routes may lead to significant differences in the flow behavior and mechanical properties of rheo-diecasting parts. Therefore, it is crucial to have a comprehensive understanding of the microstructure evolution associated with different slurry preparation routes and their resulting effects. In this study, the gas-induced semi-solid process (GISS) and the swirl enthalpy equilibrium device (SEED) routes were employed to prepare semi-solid Al-Si-Mg slurries for their simplicity and productivity in potential industrial applications. The prepared slurries were then injected into the shoot sleeves of a high-pressure die casting (HPDC) machine to produce tensile test bars. Subsequently, the bars underwent T6 treatment to enhance their mechanical properties. The microstructure, segregation, and mechanical properties of the samples were investigated and compared with those of conventional HPDC. The results indicated that the GISS and SEED can produce semi-solid slurries containing a spherical α-Al primary phase, as opposed to the dendritic structure commonly found in conventional castings. The liquid fraction had a significant effect on the flow behavior, resulting in variations in liquid segregation and mechanical properties. It was observed that a higher solid fraction (>75%) had a suppressing effect on surface liquid segregation. In addition, the tendency for liquid segregation gradually increased along the filling direction due to the special flow behavior of the semi-solid slurry with a low solid fraction. Furthermore, under the same die-casting process parameters, the conventional HPDC samples exhibit higher yield stress (139 ± 3 MPa) compared to SEED-HPDC and GISS-HPDC samples, which may be attributed to the small grain size and the distribution of eutectic phases. After undergoing the T6 treatment, both SEED-HPDC and GISS-HPDC samples showed a significant improvement in yield and tensile strength. These improvements are a result of solution and precipitation strengthening effects as well as the spheroidization of the eutectic Si phase. Moreover, the heat-treated SEED-HPDC samples demonstrate higher ultimate strength (336 ± 5 MPa) and elongation (13.7 ± 0.3%) in comparison to the GISS-HPDC samples (307 ± 4 MPa, 8.8 ± 0.2%) after heat treatment, mainly due to their low porosity density. These findings suggest that both GISS-HPDC and SEED-HPDC processes can be utilized to produce parts with favorable mechanical properties by implementing appropriate heat treatments. However, further investigation is required to control the porosities of GISS-HPDC samples during heat treatment.

5.
Molecules ; 28(18)2023 Sep 16.
Artículo en Inglés | MEDLINE | ID: mdl-37764427

RESUMEN

Strontium (Sr) is a trace element in the human body that can promote bone formation and inhibit bone absorption. A conversion coating of strontium phosphate (Sr-P) on the surface of titanium (Ti) can improve its biological properties and has many potential applications in the fields of dentistry and orthopedics. In the present study, Sr-P coatings with SrHPO4 and Sr3(PO4)2 crystals on Ti are prepared by a phosphate chemical conversion (PCC) treatment and the effect of pH values on the properties of the Sr-P coatings is researched. The results prove that the phase composition, morphology, and corrosion resistance of the coated Ti vary according to the pH values of the PCC solution. The morphology of the conversion deposition on Ti changes from plat-like to cluster-like and then to homogeneous microcrystals as the pH value changes from 2.50 to 3.25. Only discrete SrHPO4 crystals are generated on the substrate at lower pH values, while relatively stable Sr3(PO4)2 and SrHPO4 crystals grow and subsequently form an integrated coating on the Ti as the pH exceeds 2.50. The cross-sectional morphologies and bonding strength of different coatings are also researched. The corrosion resistance of coated Ti improves compared with that of bare Ti because of the Sr-P coatings with a Sr3(PO4)2 phase. In addition, it is indicated that the Sr-P coatings on Ti can improve the adhesion and differentiation of BMSCs.

6.
Materials (Basel) ; 16(18)2023 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-37763423

RESUMEN

The non-dendritic microstructure plays a crucial role in determining the rheological properties of semi-solid alloys, which are of the utmost importance for the successful industrial application of the thixoforging process. To further understand the impact of the reheating process on the evolution of microstructure and thixotropic deformation behavior in the semi-solid state, a hot extruded and T6 treated 7075 aluminum alloy was reheated to the selected temperature ranges using varying heating rates. Subsequently, thixo-compression tests were performed. The study found that during reheating and isothermal holding, the elongated microstructure of the as-supplied alloy can transform into equiaxed or spherical grains. The presence of recrystallized grains was found to be closely linked to the penetration of the liquid phase into the recrystallized grain boundaries. Furthermore, it was observed that higher heating rates resulted in smaller grain sizes. The thixotropic flow behavior of the alloy with various microstructures was analyzed using the true stress-strain curves obtained by thixo-compression experiments, which exhibited three stages: a rapid increase in true stress to a peak value, followed by a decrease in true stress and a steady stress until the end of compression. The stress fluctuated with strain during the formation of the slurry at a strain rate of 10 s-1, indicating the significant role of strain rate in material flow during semisolid formation.

7.
Sensors (Basel) ; 23(10)2023 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-37430522

RESUMEN

Spectral reflectance or transmittance measurements provide intrinsic information on the material of an object and are widely used in remote sensing, agriculture, diagnostic medicine, etc. Most reconstruction-based spectral reflectance or transmittance measurement methods based on broadband active illumination use narrow-band LEDs or lamps combined with specific filters as spectral encoding light sources. These light sources cannot achieve the designed spectral encoding with a high resolution and accuracy due to their low degree of freedom for adjustment, leading to inaccurate spectral measurements. To address this issue, we designed a spectral encoding simulator for active illumination. The simulator is composed of a prismatic spectral imaging system and a digital micromirror device. The spectral wavelengths and intensity are adjusted by switching the micromirrors. We used it to simulate spectral encodings according to the spectral distribution on micromirrors and solved the DMD patterns corresponding to the spectral encodings with a convex optimization algorithm. To verify the applicability of the simulator for spectral measurements based on active illumination, we used it to numerically simulate existing spectral encodings. We also numerically simulated a high-resolution Gaussian random measurement encoding for compressed sensing and measured the spectral reflectance of one vegetation type and two minerals through numerical simulations. We reconstructed the spectral transmittance of a calibrated filter through an experiment. The results show that the simulator can measure the spectral reflectance or transmittance with a high resolution and accuracy.

8.
Sensors (Basel) ; 23(11)2023 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-37299777

RESUMEN

As spectroscopic detection technology rapidly advances, back-illuminated InGaAs detectors with a wider spectral range have emerged. Compared to traditional detectors such as HgCdTe, CCD, and CMOS, InGaAs detectors offer a working range of 400-1800 nm and exhibit a quantum efficiency of over 60% in both the visible and near-infrared bands. This is leading to the demand for innovative designs of imaging spectrometers with wider spectral ranges. However, the widening of the spectral range has led to the presence of significant axial chromatic aberration and secondary spectrum in imaging spectrometers. Additionally, there is difficulty in aligning the system optical axis perpendicular to the detector image plane, resulting in increased challenges during post-installation adjustment. Based on chromatic aberration correction theory, this paper presents the design of a wide spectral range transmission prism-grating imaging spectrometer with a working range of 400-1750 nm using Code V. The spectral range of this spectrometer covers both the visible and near-infrared regions, which is beyond the capability of traditional PG spectrometers. In the past, the working spectral range of transmission-type PG imaging spectrometers has been limited to 400-1000 nm. This study's proposed chromatic aberration correction process involves selecting optical glass materials that match the design requirements and correcting the axial chromatic aberration and secondary spectrum, ensuring that the system axis is perpendicular to the detector plane and easy to adjust during installation. The results show that the spectrometer has a spectral resolution of 5 nm, a root-mean-square spot diagram less than 8 µm over the full field of view, and an optical transfer function MTF greater than 0.6 at a Nyquist frequency of 30 lp/mm. The system size is less than 90 mm. Spherical lenses are employed in the system design to reduce manufacturing costs and complexity while meeting the requirements of wide spectral range, miniaturization, and easy installation.


Asunto(s)
Fabaceae , Lentes , Diagnóstico por Imagen , Comercio , Vidrio
9.
R Soc Open Sci ; 5(10): 172410, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30473800

RESUMEN

The applications of magnesium (Mg) alloys as biodegradable orthopedic implants are mainly restricted due to their rapid degradation rate in the physiological environment. In this study, Si-CaP micro-arc oxidation (MAO) coatings were prepared on a Mg-Zn-Ca alloy by a second-step MAO process at different voltages in order to decrease the degradation rate and increase the bioactivity of the alloy. The microstructure and morphology of the samples were characterized using XRD, FT-IR SEM and EDS. The degradation behaviours of samples were evaluated using electrochemical techniques, and immersion tests in simulated body fluid (SBF). The results indicate that the morphology of the Si-CaP coatings changed significantly with the increase in Ca/P ratio as the second-step voltage increased. The Si-CaP containing coating produced at 450 V could significantly decrease the degradation rate of Mg and caused a slow increase in pH of the SBF solution. The haemolysis test concluded that the coating C3 did not cause a haemolytic reaction. The corrosion resistance of Mg alloy was greatly improved with the Si-CaP coatings, and the Mg alloy with Si-CaP coating prepared at 450 V had the best corrosion resistance, which indicates that the Si-CaP coatings are promising for improving the biodegradation properties of Mg-based orthopedic implants. Haemolysis tests indicated that the Si-CaP coating prepared at 450 V conforms to the given standard (YY/T0127.1-93).

10.
Phys Chem Chem Phys ; 19(23): 15110-15119, 2017 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-28561125

RESUMEN

Magnesium alloys are the most promising implant materials due to their excellent biodegradability. However, their high degradation rate limits their practical application. In this study, we produced a calcium-phosphate (Ca-P) coating and a calcium-phosphate-silicon (Ca-P-Si) coating via one-step and two-step micro-arc oxidation processes, respectively. The microstructure and chemical composition of the MAO coatings were characterized using SEM, XRD and EDS. The degradation behaviors of the MAO coatings and the substrate were investigated using electrochemical techniques and immersion tests in simulated body fluid (SBF). The results show that the silicate was successfully incorporated into the Ca-P coating in the second MAO step, and this also increased the thickness of the coating. The Ca-P-Si coatings remarkably reduced the corrosion rate of the Mg alloy and Ca-P coating during 18 days of immersion in SBF. In addition, the bone-like apatite layer on the sample surface demonstrated the good biomineralization ability of the Ca-P-Si coating. Potentiodynamic polarization results showed that the MAO coating could clearly enhance the corrosion resistance of the Mg alloy. Moreover, we propose the growth mechanism of the MAO coating in the second step.

11.
Biointerphases ; 11(3): 031006, 2016 09 20.
Artículo en Inglés | MEDLINE | ID: mdl-27440396

RESUMEN

Calcium phosphate coatings were prepared on the surface of self-designed Mg-Zn-Ca-Mn alloy using microarc oxidization technology. To characterize the microstructures, cross-section morphologies, and compositions of the coatings, the authors used scanning electron microscopy equipped with an energy-disperse spectrometer, x-ray diffraction, and Fourier transform infrared spectroscopy. Potentiodynamic polarization in the simulated body fluid (SBF) was used to evaluate the corrosion behaviors of the samples. An SBF immersion test was used to evaluate the coating bioactivity and degradability. After the immersion tests, some bonelike apatite formed on the coating surfaces indicate that bioactivity of the coatings is excellent. The coating prepared in electrolyte containing (NaPO3)6 had slower degradation rate after immersion test for 21 days.


Asunto(s)
Aleaciones/química , Cementos para Huesos/química , Materiales Biocompatibles Revestidos/química , Fosfatos/análisis , Propiedades de Superficie , Aleaciones/farmacología , Cementos para Huesos/farmacología , Materiales Biocompatibles Revestidos/farmacología , Microscopía Electrónica de Rastreo , Espectrometría por Rayos X , Espectroscopía Infrarroja por Transformada de Fourier , Difracción de Rayos X
SELECCIÓN DE REFERENCIAS