Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
Pacing Clin Electrophysiol ; 35(4): 403-8, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22309354

RESUMEN

BACKGROUND: This study aimed to describe the influence on dual-chamber devices' expected longevity of devices' settings. METHODS: Data from patients implanted with dual chamber devices (Symphony™, SORIN CRM SAS, Clamart, France) from 2003 to 2006 were collected in registries. Programmer files were retrieved: device-estimated longevity, assessed through algorithm prediction, was analyzed according to device settings. RESULTS: One thousand sixty-eight recipients of dual chamber pacemaker in sinus rhythm (75.3±11.1 years, 54.5% male, ventricular block 30%, brady-tachy syndrome 21%, and sinus node dysfunction 49%) were followed up to 14.2±12.1 months (ranging from first quartile Q1: 2.9 months to fourth quartile Q4: 49.3 months) after implantation. DDD with automatic mode conversion and minimized ventricular pacing (SafeR) modes were programmed in 34.3%, 2.9%, and 62.8% of the patients, respectively. The mean total longevity estimated by the device was 134.1±31.5 months (11.2±2.6 years). Significant increase in longevity was observed in devices undergoing at least one reprogramming (134.4±31.4 months) versus device presenting no reprogramming (103.4±32.3 months, P=0.0005). The parameters associated with the major increase in mean longevity were the mode (mean longevity increase of +23.9 months in SafeR as compared to DDD mode, P<0.0001) and the atrial (A) and ventricular (V) amplitudes (mean longevity increase of +29.6 and +26.9 months for a decrease of less than 1V in A and V outputs respectively, P<0.0001). CONCLUSION: This study provides information on dual chamber pacemakers' longevity and highlights the impact of devices' reprogramming on expected longevities.


Asunto(s)
Marcapaso Artificial , Anciano , Anciano de 80 o más Años , Algoritmos , Bradicardia/terapia , Estimulación Cardíaca Artificial/métodos , Femenino , Bloqueo Cardíaco/terapia , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Síndrome del Seno Enfermo/terapia , Síndrome , Taquicardia/terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA