Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 134
Filtrar
1.
BMC Cancer ; 24(1): 813, 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38973009

RESUMEN

BACKGROUND: Therapeutic options for early-stage hepatocellular carcinoma (HCC) in individual patients can be limited by tumor and location, liver dysfunction and comorbidities. Many patients with early-stage HCC do not receive curative-intent therapies. Stereotactic ablative body radiotherapy (SABR) has emerged as an effective, non-invasive HCC treatment option, however, randomized evidence for SABR in the first line setting is lacking. METHODS: Trans-Tasman Radiation Oncology Group (TROG) 21.07 SOCRATES-HCC is a phase II, prospective, randomised trial comparing SABR to other current standard of care therapies for patients with a solitary HCC ≤ 8 cm, ineligible for surgical resection or transplantation. The study is divided into 2 cohorts. Cohort 1 will compromise 118 patients with tumors ≤ 3 cm eligible for thermal ablation randomly assigned (1:1 ratio) to thermal ablation or SABR. Cohort 2 will comprise 100 patients with tumors > 3 cm up to 8 cm in size, or tumors ≤ 3 cm ineligible for thermal ablation, randomly assigned (1:1 ratio) to SABR or best other standard of care therapy including transarterial therapies. The primary objective is to determine whether SABR results in superior freedom from local progression (FFLP) at 2 years compared to thermal ablation in cohort 1 and compared to best standard of care therapy in cohort 2. Secondary endpoints include progression free survival, overall survival, adverse events, patient reported outcomes and health economic analyses. DISCUSSION: The SOCRATES-HCC study will provide the first randomized, multicentre evaluation of the efficacy, safety and cost effectiveness of SABR versus other standard of care therapies in the first line treatment of unresectable, early-stage HCC. It is a broad, multicentre collaboration between hepatology, interventional radiology and radiation oncology groups around Australia, coordinated by TROG Cancer Research. TRIAL REGISTRATION: anzctr.org.au, ACTRN12621001444875, registered 21 October 2021.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Radiocirugia , Nivel de Atención , Humanos , Neoplasias Hepáticas/patología , Neoplasias Hepáticas/terapia , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/cirugía , Carcinoma Hepatocelular/terapia , Carcinoma Hepatocelular/patología , Carcinoma Hepatocelular/radioterapia , Carcinoma Hepatocelular/cirugía , Radiocirugia/métodos , Estudios Prospectivos , Masculino , Femenino , Estadificación de Neoplasias , Persona de Mediana Edad , Ensayos Clínicos Controlados Aleatorios como Asunto , Anciano , Adulto
2.
Artículo en Inglés | MEDLINE | ID: mdl-38985969

RESUMEN

INTRODUCTION: Stereotactic ablative body radiotherapy (SABR) is a highly conformal technique utilising a high dose per fraction commonly employed in the re-treatment of spinal metastases. This study sought to determine the safety and efficacy of re-irradiation with SABR to previously treated spinal metastases. METHODS: This was a retrospective analysis of patients at three Australian centres who have undergone spinal SABR after previous spinal radiotherapy to the same or immediately adjacent vertebral level. Efficacy was determined in terms of rates of local control, while safety was characterised by rates of serious complications. RESULTS: Thirty-three spinal segments were evaluated from 32 patients. Median follow-up for all patients was 2.6 years, and median overall survival was 4.3 years. Eleven of 33 (33.3%) treated spinal segments had local progression, with a local control rate at 12 months of 71.4% (95% C.I. 55.2%-92.4%). Four patients (16.7%) went on to develop cauda equina or spinal cord compression. Thirteen out of 32 patients (40.6%) experienced acute toxicity, of which 12 were grade 2 or less. Five out of 30 spinal (16.7%) segments with follow-up imaging had a radiation-induced vertebral compression fracture. There was one case of radiation myelitis which occurred in a patient who had mediastinal radiotherapy with a treatment field which overlapped their prior spinal radiation. CONCLUSION: The patients in this study experienced long median survival, durable tumour control and high rates of freedom from long-term sequelae of treatment. These results support the use of SABR in patients who progress in the spine despite previous radiotherapy.

3.
Phys Med ; 124: 103423, 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38970949

RESUMEN

PURPOSE: This study aimed to analyse correlations between planning factors including plan geometry and plan complexity with robustness to patient setup errors. METHODS: Multiple-target brain stereotactic radiosurgery (SRS) plans were obtained through the Trans-Tasman Radiation Oncology Group (TROG) international treatment planning challenge (2018). The challenge dataset consisted of five intra-cranial targets with a 20 Gy prescription. Setup error was simulated using an in-house tool. Dose to targets was assessed via dose covering 99 % (D99 %) of gross tumour volume (GTV) and 98 % of planning target volume (PTV). Dose to organs at risk was assessed using volume of normal brain receiving 12 Gy and maximum dose covering 0.03 cc of brainstem. Plan complexity was assessed via edge metric, modulation complexity score, mean multi-leaf collimator (MLC) gap, mean MLC speed and plan modulation. RESULTS: Even for small (0.5 mm/°) errors, GTV D99 % was reduced by up to 20 %. The strongest correlation was found between lower complexity plans (larger mean MLC gap and lower edge metric) and higher robustness to setup error. Lower complexity plans had 1 %-20 % fewer targets/scenarios with GTV D99 % falling below the specified tolerance threshold. These complexity metrics correlated with 100 % isodose volume sphericity and dose conformity, though similar conformity was achievable with a range of complexities. CONCLUSIONS: A higher level of importance should be directed towards plan complexity when considering plan robustness. It is recommended when planning multi-target SRS, larger MLC gaps and lower MLC aperture irregularity be considered during plan optimisation due to higher robustness should patient positioning errors occur.

4.
Radiother Oncol ; 198: 110376, 2024 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-38857700

RESUMEN

INTRODUCTION: Use of stereotactic ablative radiotherapy (SABR) for central lung tumors can result in up to a 35% incidence of late pulmonary toxicity. We evaluated an automated scoring method to quantify post-SABR bronchial changes by using artificial intelligence (AI)-based airway segmentation. MATERIALS AND METHODS: Central lung SABR patients treated at Amsterdam UMC (AUMC, internal reference dataset) and Peter MacCallum Cancer Centre (PMCC, external validation dataset) were identified. Patients were eligible if they had pre- and post-SABR CT scans with ≤ 1 mm resolution. The first step of the automated scoring method involved AI-based airway auto-segmentation using MEDPSeg, an end-to-end deep learning-based model. The Vascular Modeling Toolkit in 3D Slicer was then used to extract a centerline curve through the auto-segmented airway lumen, and cross-sectional measurements were computed along each bronchus for all CT scans. For AUMC patients, airway stenosis/occlusion was evaluated by both visual assessment and automated scoring. Only the automated method was applied to the PMCC dataset. RESULTS: Study patients comprised 26 from AUMC, and 33 from PMCC. Visual scoring identified stenosis/occlusion in 8 AUMC patients (31 %), most frequently in the segmental bronchi. After airway auto-segmentation, minor manual edits were needed in 9 % of patients. Segmentation for a single scan averaged 83sec (range 73-136). Automated scoring nearly doubled detected airway stenosis/occlusion (n = 15, 58 %), and allowed for earlier detection in 5/8 patients who had also visually scored changes. Estimated rates were 48 % and 66 % at 1- and 2-years, respectively, for the internal dataset. The automated detection rate was 52 % in the external dataset, with 1- and 2-year risks of 56 % and 61 %, respectively. CONCLUSION: An AI-based automated scoring method allows for detection of more bronchial stenosis/occlusion after lung SABR, and at an earlier time-point. This tool can facilitate studies to determine early airway changes and establish more reliable airway tolerance doses.

5.
Phys Eng Sci Med ; 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38805104

RESUMEN

Motion management has become an integral part of radiation therapy. Multiple approaches to motion management have been reported in the literature. To allow the sharing of experiences on current practice and emerging technology, the University of Sydney and the New South Wales/Australian Capital Territory branch of the Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) held a two-day motion management workshop. To inform the workshop program, participants were invited to complete a survey prior to the workshop on current use of motion management techniques and their opinion on the effectiveness of each approach. A post-workshop survey was also conducted, designed to capture changes in opinion as a result of workshop participation. The online workshop was the most well attended ever hosted by the ACPSEM, with over 300 participants and a response to the pre-workshop survey was received from at least 60% of the radiation therapy centres in Australia and New Zealand. Motion management is extensively used in the region with use of deep inspiration breath-hold (DIBH) reported by 98% of centres for left-sided breast treatments and 91% for at least some right-sided breast treatments. Surface guided radiation therapy (SGRT) was the most popular session at the workshop and survey results showed that the use of SGRT is likely to increase. The workshop provided an excellent opportunity for the exchange of knowledge and experience, with most survey respondents indicating that their participation would lead to improvements in the quality of delivery of treatments at their centres.

6.
Artículo en Inglés | MEDLINE | ID: mdl-38757728

RESUMEN

Delineation of cardiac substructures is crucial for a better understanding of radiation-related cardiotoxicities and to facilitate accurate and precise cardiac dose calculation for developing and applying risk models. This review examines recent advancements in cardiac substructure delineation in the radiation therapy (RT) context, aiming to provide a comprehensive overview of the current level of knowledge, challenges and future directions in this evolving field. Imaging used for RT planning presents challenges in reliably visualising cardiac anatomy. Although cardiac atlases and contouring guidelines aid in standardisation and reduction of variability, significant uncertainties remain in defining cardiac anatomy. Coupled with the inherent complexity of the heart, this necessitates auto-contouring for consistent large-scale data analysis and improved efficiency in prospective applications. Auto-contouring models, developed primarily for breast and lung cancer RT, have demonstrated performance comparable to manual contouring, marking a significant milestone in the evolution of cardiac delineation practices. Nevertheless, several key concerns require further investigation. There is an unmet need for expanding cardiac auto-contouring models to encompass a broader range of cancer sites. A shift in focus is needed from ensuring accuracy to enhancing the robustness and accessibility of auto-contouring models. Addressing these challenges is paramount for the integration of cardiac substructure delineation and associated risk models into routine clinical practice, thereby improving the safety of RT for future cancer patients.

7.
Pract Radiat Oncol ; 2024 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-38705233

RESUMEN

PURPOSE: Functional lung avoidance (FLA) radiation therapy is an evolving field. The aim of FLA planning is to reduce dose to areas of functioning lung, with comparable target coverage and dose to organs at risk. Multicriteria optimization (MCO) is a planning tool that may assist with FLA planning. This study assessed the feasibility of using MCO to adapt radiation therapy plans to avoid functional regions of lung that were identified using a 68Ga-4D-V/Q positron emission tomography/computed tomography. METHODS AND MATERIALS: A prospective clinical trial U1111-1138-4421 was performed in which patients had a 68Ga-4D-V/Q positron emission tomography/computed tomography before radiation treatment. Of the 72 patients enrolled in this trial, 38 patients had stage III non-small cell lung cancer and were eligible for selection into this planning study. Functional lung target volumes HF lung (highly functioning lung) and F lung (functional lung) were defined using the ventilated and perfused lung. Using knowledge-based planning, a baseline anatomic plan was created, and then a functional adapted plan was generated using multicriteria optimization. The primary aim was to spare dose to HF lung. Using the MCO tools, a clinician selected the final FLA plan. Dose to functional lung, target volumes, organs at risk and measures of plan quality were compared using standard statistical methods. RESULTS: The HF lung volume was successfully spared in all patients. The F lung volume was successfully spared in 36 of the 38 patients. There were no clinically significant differences in dose to anatomically defined organs at risk. There were differences in the planning target volume near maximum and minimum doses. Across the entire population, there was a statistically significant reduction in the functional mean lung dose but not in the functional volume receiving 20 Gy. All trade-off decisions were made by the clinician. CONCLUSIONS: Using MCO for FLA was achievable but did result in changes to planning target volume coverage. A distinct advantage in using MCO was that all decisions regarding the cost and benefits of FLA could be made in real time.

8.
Phys Med ; 121: 103363, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38653119

RESUMEN

Dosimetry audits for passive motion management require dynamically-acquired measurements in a moving phantom to be compared to statically calculated planned doses. This study aimed to characterise the relationship between planning and delivery errors, and the measured dose in the Imaging and Radiation Oncology Core (IROC) thorax phantom, to assess different audit scoring approaches. Treatment plans were created using a 4DCT scan of the IROC phantom, equipped with film and thermoluminescent dosimeters (TLDs). Plans were created on the average intensity projection from all bins. Three levels of aperture complexity were explored: dynamic conformal arcs (DCAT), low-, and high-complexity volumetric modulated arcs (VMATLo, VMATHi). Simulated-measured doses were generated by modelling motion using isocenter shifts. Various errors were introduced including incorrect setup position and target delineation. Simulated-measured film doses were scored using gamma analysis and compared within specific regions of interest (ROIs) as well as the entire film plane. Positional offsets were estimated based on isodoses on the film planes, and point doses within TLD contours were compared. Motion-induced differences between planned and simulated-measured doses were evident even without introduced errors Gamma passing rates within target-centred ROIs correlated well with error-induced dose differences, while whole film passing rates did not. Isodose-based setup position measurements demonstrated high sensitivity to errors. Simulated point doses at TLD locations yielded erratic responses to introduced errors. ROI gamma analysis demonstrated enhanced sensitivity to simulated errors compared to whole film analysis. Gamma results may be further contextualized by other metrics such as setup position or maximum gamma.


Asunto(s)
Movimiento , Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador , Tórax , Tórax/diagnóstico por imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Humanos , Radiometría/instrumentación , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada , Tomografía Computarizada Cuatridimensional , Movimiento (Física)
9.
Artículo en Inglés | MEDLINE | ID: mdl-38679212

RESUMEN

PURPOSE: Stereotactic ablative body radiotherapy (SABR) is a novel option to treat primary renal cell carcinoma. However, a high radiation dose may be received by the treated kidney, which may affect its function posttreatment. This study investigates the dose-effect relationship of kidney SABR with posttreatment renal function. METHODS AND MATERIALS: This was a prespecified secondary endpoint of the multicenter FASTRACK II (Focal Ablative STereotactic RAdiotherapy for Cancers of the Kidney phase II) clinical trial (National Clinical Trial 02613819). Patients received either 26 Gy in a single fraction (SF) for tumors with a maximal diameter of 4 cm or less or 42 Gy in 3 fractions (multifraction [MF]) for larger tumors. To determine renal function change, 99mTc-dimercaptosuccinic acid (DMSA) single-photon emission computed tomography/computed tomography (SPECT/CT) scans were acquired, and the glomerular filtration rate was estimated at baseline, 12, and 24 months posttreatment. Imaging data sets were rigidly registered to the planning CT where kidneys were segmented to calculate dose-response curves. RESULTS: From 71 enrolled patients, 36 (51%) and 26 (37%) patients were included in this study based on availability of posttreatment data at 12 and 24 months, respectively. The ipsilateral kidney glomerular filtration rate decreased from baseline by 42% and 39% in the SF cohort and by 45% and 62% in the MF cohort, at 12 and 24 months, respectively (P < .03). The loss in renal function was 3.6%/Gy ± 0.8%/Gy and 4.5%/Gy ± 1.0%/Gy in the SF cohort and 1.7%/Gy ± 0.1%/Gy and 1.7%/Gy ± 0.2%/Gy in the MF cohort at 12 and 24 months, respectively. The major loss in renal function occurred in high-dose regions, where dose-response curves converged to a plateau. CONCLUSIONS: For the first time in a multicenter study, the dose-effect relationship at 12 and 24 months post-SABR treatment for primary renal cell carcinoma was quantified. Kidney function reduces linearly with dose up to 100 Gy BED3.

11.
Radiother Oncol ; 194: 110184, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38453055

RESUMEN

BACKGROUND AND PURPOSE: Safe reirradiation relies on assessment of cumulative doses to organs at risk (OARs) across multiple treatments. Different clinical pathways can result in inconsistent estimates. Here, we quantified the consistency of cumulative dose to OARs across multi-centre clinical pathways. MATERIAL AND METHODS: We provided DICOM planning CT, structures and doses for two reirradiation cases: head & neck (HN) and lung. Participants followed their standard pathway to assess the cumulative physical and EQD2 doses (with provided α/ß values), and submitted DVH metrics and a description of their pathways. Participants could also submit physical dose distributions from Course 1 mapped onto the CT of Course 2 using their best available tools. To assess isolated impact of image registrations, a single observer accumulated each submitted spatially mapped physical dose for every participating centre. RESULTS: Cumulative dose assessment was performed by 24 participants. Pathways included rigid (n = 15), or deformable (n = 5) image registration-based 3D dose summation, visual inspection of isodose line contours (n = 1), or summation of dose metrics extracted from each course (n = 3). Largest variations were observed in near-maximum cumulative doses (25.4 - 41.8 Gy for HN, 2.4 - 33.8 Gy for lung OARs), with lower variations in volume/dose metrics to large organs. A standardised process involving spatial mapping of the first course dose to the second course CT followed by summation improved consistency for most near-maximum dose metrics in both cases. CONCLUSION: Large variations highlight the uncertainty in reporting cumulative doses in reirradiation scenarios, with implications for outcome analysis and understanding of published doses. Using a standardised workflow potentially including spatially mapped doses improves consistency in determination of accumulated dose in reirradiation scenarios.


Asunto(s)
Neoplasias de Cabeza y Cuello , Neoplasias Pulmonares , Órganos en Riesgo , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Reirradiación , Humanos , Reirradiación/métodos , Neoplasias de Cabeza y Cuello/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Órganos en Riesgo/efectos de la radiación , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/diagnóstico por imagen , Tomografía Computarizada por Rayos X
12.
Lancet Respir Med ; 12(6): 467-475, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38490228

RESUMEN

BACKGROUND: Systematic mediastinal lymph node staging by endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) improves accuracy of staging in patients with early-stage non-small-cell lung cancer (NSCLC). However, patients with locally advanced NSCLC commonly undergo only selective lymph node sampling. This study aimed to determine the proportion of patients with locally advanced NSCLC in whom systematic endoscopic mediastinal staging identified PET-occult lymph node metastases, and to describe the consequences of PET-occult disease on radiotherapy planning. METHODS: This prospective, international, multicentre, single-arm, international study was conducted at seven tertiary lung cancer centres in four countries (Australia, Canada, the Netherlands, and the USA). Patients aged 18 years or older with suspected or known locally advanced NSCLC underwent systematic endoscopic mediastinal lymph node staging before combination chemoradiotherapy or high-dose palliative radiotherapy. The primary endpoint was the proportion of participants with PET-occult mediastinal lymph node metastases shown following systematic endoscopic staging. The study was prospectively registered with Australian New Zealand Clinical Trials Registry, ACTRN12617000333314. FINDINGS: From Jan 30, 2018, to March 23, 2022, 155 patients underwent systematic endoscopic mediastinal lymph node staging and were eligible for analysis. 58 (37%) of patients were female and 97 (63%) were male. Discrepancy in extent of mediastinal disease identified by PET and EBUS-TBNA was observed in 57 (37% [95% CI 29-44]) patients. PET-occult lymph node metastases were identified in 18 (12% [7-17]) participants, including 16 (13% [7-19]) of 123 participants with clinical stage IIIA or cN2 NSCLC. Contralateral PET-occult N3 disease was identified in nine (7% [2-12]) of 128 participants staged cN0, cN1, or cN2. Identification of PET-occult disease resulted in clinically significant changes to treatment in all 18 patients. In silico dosimetry studies showed the median volume of PET-occult lymph nodes receiving the prescription dose of 60 Gy was only 10·1% (IQR 0·1-52·3). No serious adverse events following endoscopic staging were reported. INTERPRETATION: Our findings suggests that systematic endoscopic mediastinal staging in patients with locally advanced or unresectable NSCLC is more accurate than PET alone in defining extent of mediastinal involvement. Standard guideline-recommended PET-based radiotherapy planning results in suboptimal tumour coverage. Our findings indicate that systematic endoscopic staging should be routinely performed in patients with locally advanced NSCLC being considered for radiotherapy to accurately inform radiation planning and treatment decision making in patients with locally advanced NSCLC. FUNDING: None.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Metástasis Linfática , Mediastino , Estadificación de Neoplasias , Humanos , Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Carcinoma de Pulmón de Células no Pequeñas/patología , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Masculino , Femenino , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/diagnóstico por imagen , Persona de Mediana Edad , Anciano , Estudios Prospectivos , Mediastino/patología , Metástasis Linfática/radioterapia , Australia , Países Bajos , Ganglios Linfáticos/patología , Ganglios Linfáticos/diagnóstico por imagen , Canadá , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Estados Unidos , Tomografía de Emisión de Positrones/métodos
13.
Phys Imaging Radiat Oncol ; 29: 100536, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38303922

RESUMEN

Background and purpose: Glioblastoma is one of the most common and aggressive primary brain tumours in adults. Though radiation therapy (RT) techniques have progressed significantly in recent decades, patient survival has seen little improvement. However, an area of promise is the use of fluorine-18-fluoroethyltyrosine positron-emission-tomography (18F-FET PET) imaging to assist in RT target delineation. This retrospective study aims to assess the impact of 18F-FET PET scan timing on the resultant RT target volumes and subsequent RT plans in post-operative glioblastoma patients. Materials and Methods: The imaging and RT treatment data of eight patients diagnosed with glioblastoma and treated at a single institution were analysed. Before starting RT, each patient had two 18F-FET-PET scans acquired within seven days of each other. The information from these 18F-FET-PET scans aided in the creation of two novel target volume sets. The new volumes and plans were compared with each other and the originals. Results: The median clinical target volume (CTV) 1 was statistically smaller than CTV 2. The median Dice score for the CTV1/CTV2 was 0.98 and, of the voxels that differ (median 6.5 cc), 99.7% were covered with a 5 mm expansion. Overall organs at risk (OAR) and target dosimetry were similar in the PTV1 and PTV2 plans. Conclusion: Provided the 18F-FET PET scan is acquired within two weeks of the RT planning and a comprehensive approach is taken to CTV delineation, the timing of scan acquisition has minimal impact on the resulting RT plan.

14.
Radiother Oncol ; 194: 110185, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38412905

RESUMEN

BACKGROUND: Locally advanced, bulky, unresectable sarcomas cause significant tumour mass effects, leading to burdensome symptoms. We have developed a novel Partially Ablative Body Radiotherapy (PABR) technique that delivers a high, ablative dose to the tumour core and a low, palliative dose to its periphery aiming to increase overall tumour response without significantly increasing treatment toxicity. AIM: This study aims to report the safety and oncologic outcomes of PABR in patients with bulky, unresectable sarcomas. METHODS AND MATERIALS: A total of 18 patients with histologically proven sarcoma treated with PABR from January 2020 to October 2023 were retrospectively reviewed. The primary endpoints were symptomatic and structural response rates. Secondary endpoints were overall survival, freedom from local progression, freedom from distant progression, and acute and late toxicity rates. RESULTS: All patients had tumours ≥5 cm with a median tumour volume of 985 cc, and the most common symptom was pain. The median age is 72.5 years and 44.5 % were ECOG 2-3. The most common regimen used was 20 Gy in 5 fractions with an intratumoral boost dose of 50 Gy (83.3 %). After a median follow-up of 11 months, 88.9 % of patients exhibited a partial response with a mean absolute tumour volume reduction of 49.5 %. All symptomatic patients experienced symptom improvement. One-year OS, FFLP and FFDP were 61 %, 83.3 % and 34.8 %, respectively. There were no grade 3 or higher toxicities. CONCLUSION: PABR for bulky, unresectable sarcomas appears to be safe and may provide good symptomatic response, tumour debulking, and local control. Further study is underway.


Asunto(s)
Cuidados Paliativos , Sarcoma , Humanos , Sarcoma/radioterapia , Sarcoma/patología , Sarcoma/cirugía , Sarcoma/mortalidad , Masculino , Cuidados Paliativos/métodos , Femenino , Anciano , Estudios Retrospectivos , Persona de Mediana Edad , Anciano de 80 o más Años , Carga Tumoral , Adulto , Dosificación Radioterapéutica
15.
Lancet Oncol ; 25(3): 308-316, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38423047

RESUMEN

BACKGROUND: Stereotactic ablative body radiotherapy (SABR) is a novel non-invasive alternative for patients with primary renal cell cancer who do not undergo surgical resection. The FASTRACK II clinical trial investigated the efficacy of SABR for primary renal cell cancer in a phase 2 trial. METHODS: This international, non-randomised, phase 2 study was conducted in seven centres in Australia and one centre in the Netherlands. Eligible patients aged 18 years or older had biopsy-confirmed diagnosis of primary renal cell cancer, with only a single lesion; were medically inoperable, were at high risk of complications from surgery, or declined surgery; and had an Eastern Cooperative Oncology Group performance status of 0-2. A multidisciplinary decision that active treatment was warranted was required. Key exclusion criteria were a pre-treatment estimated glomerular filtration rate of less than 30 mL/min per 1·73 m2, previous systemic therapies for renal cell cancer, previous high-dose radiotherapy to an overlapping region, tumours larger than 10 cm, and direct contact of the renal cell cancer with the bowel. Patients received either a single fraction SABR of 26 Gy for tumours 4 cm or less in maximum diameter, or 42 Gy in three fractions for tumours more than 4 cm to 10 cm in maximum diameter. The primary endpoint was local control, defined as no progression of the primary renal cell cancer, as evaluated by the investigator per Response Evaluation Criteria in Solid Tumours (version 1.1). Assuming a 1-year local control of 90%, the null hypothesis of 80% or less was considered not to be worthy of proceeding to a future randomised controlled trial. All patients who commenced trial treatment were included in the primary outcome analysis. This trial is registered with ClinicalTrials.gov, NCT02613819, and has completed accrual. FINDINGS: Between July 28, 2016, and Feb 27, 2020, 70 patients were enrolled and initiated treatment. Median age was 77 years (IQR 70-82). Before enrolment, 49 (70%) of 70 patients had documented serial growth on initial surveillance imaging. 49 (70%) of 70 patients were male and 21 (30%) were female. Median tumour size was 4·6 cm (IQR 3·7-5·5). All patients enrolled had T1-T2a and N0-N1 disease. 23 patients received single-fraction SABR of 26 Gy and 47 received 42 Gy in three fractions. Median follow-up was 43 months (IQR 38-60). Local control at 12 months from treatment commencement was 100% (p<0·0001). Seven (10%) patients had grade 3 treatment-related adverse events, with no grade 4 adverse events observed. Grade 3 treatment-related adverse events were nausea and vomiting (three [4%] patients), abdominal, flank, or tumour pain (four [6%]), colonic obstruction (two [3%]), and diarrhoea (one [1%]). No treatment-related or cancer-related deaths occurred. INTERPRETATION: To our knowledge, this is the first multicentre prospective clinical trial of non-surgical definitive therapy in patients with primary renal cell cancer. In a cohort with predominantly T1b or larger disease, SABR was an effective treatment strategy with no observed local failures or cancer-related deaths. We observed an acceptable side-effect profile and renal function after SABR. These outcomes support the design of a future randomised trial of SABR versus surgery for primary renal cell cancer. FUNDING: Cancer Australia Priority-driven Collaborative Cancer Research Scheme.


Asunto(s)
Carcinoma de Células Renales , Neoplasias Renales , Radiocirugia , Anciano , Femenino , Humanos , Masculino , Carcinoma de Células Renales/radioterapia , Neoplasias Renales/radioterapia , Neoplasias Renales/patología , Estudios Prospectivos , Radiocirugia/efectos adversos , Radiocirugia/métodos , Resultado del Tratamiento , Anciano de 80 o más Años
16.
J Appl Clin Med Phys ; 25(6): e14276, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38414322

RESUMEN

PURPOSE: Patient-specific quality assurance (PSQA) for vertebra stereotactic body radiation therapy (SBRT) presents challenges due to highly modulated small fields with high-dose gradients between the target and spinal cord. This study aims to explore the use of the SRS MapCHECK® (SRSMC) for vertebra SBRT PSQA. METHODS: Twenty vertebra SBRT treatment plans including prescriptions 20 Gy/1 fraction and 24 Gy/2 fractions were selected for each of Millennium (M)-Multileaf Collimator (MLC), and high-definition (HD)-MLC. All 40 plans were measured using Gafchromic EBT3 film (film) and SRSMC, using the StereoPHAN phantom. Plan complexity was assessed using modulation complexity score (MCS), edge metric (EM) (mm-1), modulation factor (MU/cGy), and average leaf pair opening (ALPO) (mm) and its correlation with gamma-pass rate was investigated. The high dose gradient between the target and the spinal cord was analyzed for film and SRSMC and compared against the treatment planning system (TPS). Applying the methodology proposed by AAPM TG-218, action and tolerance values specific to the SRSMC for vertebra SBRT were determined for ß values ranging from 5 to 8. RESULTS: Film and SRSMC gamma-pass rates showed no correlation (p > 0.05). A moderate negative correlation (R = -0.57, p = 0.01) is present between EM and SRSMC 3%/1 mm gamma-pass rate for HD-MLC plans. Both film and SRSMC accurately measured high dose gradients between the target and the spinal cord (R2 > 0.86, p ≤ 0.05). Notably, dose-gradient of HD-MLC plans is 22% steeper and has a smaller standard deviation to M-MLC plans (p ≤ 0.05). Applying TG-218, the film tolerance limit was 96% with action limit 95% for 5%/1 mm (ß = 6) and for the SRSMC tolerance limit was 97% with an action limit of 96% for 4%/1 mm (ß = 6). CONCLUSION: Our findings suggest that universal TG-218 limits may not be suitable for vertebra SBRT PSQA. This study demonstrates that SRSMC is a viable tool for vertebra SBRT PSQA, supported by TG-218 implementation of process-based tolerance and action limits.


Asunto(s)
Órganos en Riesgo , Fantasmas de Imagen , Garantía de la Calidad de Atención de Salud , Radiocirugia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Garantía de la Calidad de Atención de Salud/normas , Órganos en Riesgo/efectos de la radiación , Neoplasias de la Columna Vertebral/cirugía , Neoplasias de la Columna Vertebral/radioterapia
17.
Med Phys ; 51(7): 4767-4777, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38376454

RESUMEN

BACKGROUND: Auto-segmentation of organs-at-risk (OARs) in the head and neck (HN) on computed tomography (CT) images is a time-consuming component of the radiation therapy pipeline that suffers from inter-observer variability. Deep learning (DL) has shown state-of-the-art results in CT auto-segmentation, with larger and more diverse datasets showing better segmentation performance. Institutional CT auto-segmentation datasets have been small historically (n < 50) due to the time required for manual curation of images and anatomical labels. Recently, large public CT auto-segmentation datasets (n > 1000 aggregated) have become available through online repositories such as The Cancer Imaging Archive. Transfer learning is a technique applied when training samples are scarce, but a large dataset from a closely related domain is available. PURPOSE: The purpose of this study was to investigate whether a large public dataset could be used in place of an institutional dataset (n > 500), or to augment performance via transfer learning, when building HN OAR auto-segmentation models for institutional use. METHODS: Auto-segmentation models were trained on a large public dataset (public models) and a smaller institutional dataset (institutional models). The public models were fine-tuned on the institutional dataset using transfer learning (transfer models). We assessed both public model generalizability and transfer model performance by comparison with institutional models. Additionally, the effect of institutional dataset size on both transfer and institutional models was investigated. All DL models used a high-resolution, two-stage architecture based on the popular 3D U-Net. Model performance was evaluated using five geometric measures: the dice similarity coefficient (DSC), surface DSC, 95th percentile Hausdorff distance, mean surface distance (MSD), and added path length. RESULTS: For a small subset of OARs (left/right optic nerve, spinal cord, left submandibular), the public models performed significantly better (p < 0.05) than, or showed no significant difference to, the institutional models under most of the metrics examined. For the remaining OARs, the public models were inferior to the institutional models, although performance differences were small (DSC ≤ 0.03, MSD < 0.5 mm) for seven OARs (brainstem, left/right lens, left/right parotid, mandible, right submandibular). The transfer models performed significantly better than the institutional models for seven OARs (brainstem, right lens, left/right optic nerve, left/right parotid, spinal cord) with a small margin of improvement (DSC ≤ 0.02, MSD < 0.4 mm). When numbers of institutional training samples were limited, public and transfer models outperformed the institutional models for most OARs (brainstem, left/right lens, left/right optic nerve, left/right parotid, spinal cord, and left/right submandibular). CONCLUSION: Training auto-segmentation models with public data alone was suitable for a small number of OARs. Using only public data incurred a small performance deficit for most other OARs, when compared with institutional data alone, but may be preferable over time-consuming curation of a large institutional dataset. When a large institutional dataset was available, transfer learning with models pretrained on a large public dataset provided a modest performance improvement for several OARs. When numbers of institutional samples were limited, using the public dataset alone, or as a pretrained model, was beneficial for most OARs.


Asunto(s)
Neoplasias de Cabeza y Cuello , Procesamiento de Imagen Asistido por Computador , Órganos en Riesgo , Tomografía Computarizada por Rayos X , Órganos en Riesgo/efectos de la radiación , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/radioterapia , Aprendizaje Profundo , Conjuntos de Datos como Asunto
18.
Radiat Oncol ; 19(1): 23, 2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-38355495

RESUMEN

BACKGROUND: Stereotactic ablative body radiotherapy (SABR) is an emerging treatment for patients with primary renal cell carcinoma (RCC). However, its impact on renal function is unclear. This study aimed to evaluate incidence and clinical factors predictive of severe to end-stage chronic kidney disease (CKD) after SABR for RCC. METHODS AND MATERIALS: This was a Single institutional retrospective analysis of patients with diagnosed primary RCC receiving SABR between 2012-2020. Adult patients with no metastatic disease, baseline estimated glomerular filtration rate (eGFR) of ≥ 30 ml/min/1.73 m2, and at least one post-SABR eGFR at six months or later were included in this analysis. Patients with upper tract urothelial carcinoma were excluded. Primary outcome was freedom from severe to end-stage CKD, determined using the Kaplan-Meier estimator. The impact of baseline CKD, age, hypertension, diabetes, tumor size and fractionation schedule were assessed by Cox proportional hazard models. RESULTS: Seventy-eight consecutive patients were included, with median age of 77.8 years (IQR 70-83), tumor size of 4.5 cm (IQR 3.9-5.8) and follow-up of 42.2 months (IQR 23-60). Baseline median eGFR was 58 mls/min; 55% (n = 43) of patients had baseline CKD stage 3 and the remainder stage 1-2. By last follow-up, 1/35 (2.8%) of baseline CKD 1-2, 7/27 (25.9%) CKD 3a and 11/16 (68.8%) CKD 3b had developed CKD stage 4-5. The estimated probability of freedom from CKD stage 4-5 at 1 and 5 years was 89.6% (CI 83.0-97.6) and 65% (CI 51.4-81.7) respectively. On univariable analysis, worse baseline CKD (p < 0.0001) and multi-fraction SABR (p = 0.005) were predictive for development of stage 4-5 CKD though only the former remained significant in multivariable model. CONCLUSION: In this elderly cohort with pre-existing renal dysfunction, SABR achieved satisfactory nephron sparing with acceptable rates of severe to end-stage CKD. It can be an attractive option in patients who are medically inoperable.


Asunto(s)
Carcinoma de Células Renales , Carcinoma de Células Transicionales , Fallo Renal Crónico , Neoplasias Renales , Radiocirugia , Insuficiencia Renal Crónica , Neoplasias de la Vejiga Urinaria , Adulto , Humanos , Anciano , Anciano de 80 o más Años , Carcinoma de Células Renales/cirugía , Carcinoma de Células Renales/radioterapia , Neoplasias Renales/cirugía , Neoplasias Renales/patología , Estudios Retrospectivos , Radiocirugia/efectos adversos , Radiocirugia/métodos , Fallo Renal Crónico/etiología , Insuficiencia Renal Crónica/etiología
19.
Int J Radiat Oncol Biol Phys ; 118(3): 866-867, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38340772
20.
Radiother Oncol ; 190: 110042, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38043902

RESUMEN

The results of phase II and III trials on Stereotactic Body Radiation Therapy (SBRT) increased adoption of SBRT worldwide. The ability to replicate clinical trial outcomes in routine practice depends on the capability to reproduce technical and dosimetric procedures used in the clinical trial. In this systematic review, we evaluated if peer-reviewed publications of clinical trials in SBRT reported sufficient technical data to ensure safe and robust implementation in real world clinics. Twenty papers were selected for inclusion, and data was extracted by a working group of medical physicists created following the ESTRO 2021 physics workshop. A large variability in technical and dosimetric data were observed, with frequent lack of required information for reproducing trial procedures. None of the evaluated studies were judged completely reproducible from a technical perspective. A list of recommendations has been provided by the group, based on the analysis and consensus process, to ensure an adequate reproducibility of technical parameters in primary SBRT clinical trials. Future publications should consider these recommendations to assist transferability of the clinical trial in real world practice.


Asunto(s)
Radiocirugia , Humanos , Radiocirugia/métodos , Reproducibilidad de los Resultados , Radiometría , Planificación de la Radioterapia Asistida por Computador/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA