Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
J Orthod Sci ; 13: 20, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38784083

RESUMEN

In most recent studies, long-term retention after orthodontic treatment has been hypothesized that may be necessary to maintain the stability of the dentition and avoid post-treatment changes. The bonded fixed retainer is characterized by its clinical effectiveness, patient acceptance, and lack of patient complaints as compared with a removable retainer. An electronic database (such as PubMed, PubMed Central, Web of Science, Science Direct, Cochrane Library, Scopus, and ResearchGate) has been collected using specific keywords. Of the 152 articles, only randomized clinical trials that investigated different types of fixed retainers or compared fixed with removable retainers were illustrated in tables and included in this review. The present review has gone some way towards enhancing our understanding of the bonded fixed retainer, types, material, bonding methods, and how to improve its the success rate, besides the importance of new technology in fixed orthodontic retention.

2.
Biomed Tech (Berl) ; 64(5): 555-562, 2019 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-30875315

RESUMEN

The aim of this study was to investigate the retention forces of secondary telescopic crowns made of polyetherketoneketone (PEKK) in combination with primary crowns made of four different dental alloys and to determine whether the retention forces change in the course of up to 5000 simulated wear cycles. A total of four groups of telescopic crowns were investigated: group 1: 10 primary crowns made of a gold alloy (NEOCAST®3), group 2: 10 primary crowns made of a non-precious metal alloy (Girobond NB), group 3: 10 primary crowns made of zirconium (Cercon®base) and group 4: 10 primary crowns made from PEKK (Pekkton®ivory). The corresponding secondary crowns were made from PEKK in all the four groups. Each pair was fixed axially in a wear simulator specifically designed for the study. Overall, 10,000 joining and separating cycles were performed for each group. To simulate intraoral conditions, a saliva substitute served as a lubricant. Force transducers were used to record the retention forces and after completing 10,000 cycles, the surface of each primary crown was examined using a scanning electron microscope (SEM). All groups showed an increase in the retention force for the first 2000 cycles which stayed constant for the remaining 8000 cycles. The Pekkton®ivory/Pekkton®ivory and NEOCAST®3/Pekkton®ivory combinations displayed mean retention force values of 16 N after a slight increase in the retention force. The Cercon®base/Pekkton®ivory and Girobond NB/Pekkton®ivory combinations displayed an initially high increase in the retention force and then showed a mean retention force of up to 29 N. All primary crowns displayed surface wear. Zirconium primary crowns showed the least wear compared to PEKK and the gold and non-precious metal alloys.


Asunto(s)
Análisis del Estrés Dental/instrumentación , Aleaciones de Oro/química , Coronas , Aleaciones Dentales , Humanos , Circonio
3.
Ann Anat ; 222: 146-152, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30599239

RESUMEN

The formation of the alveolar bone, which houses the dental primordia, and later the roots of tooth, may serve as a model to approach general questions of alveolar bone formation. In this respect, this study aimed to investigate the potential interactions between the alveolar bone formation and tooth eruption by using finite element (FE) methods, and to figure out whether the expanding tooth systems induce shear stresses that lead to alveolar bone formation. 3D geometric surface models were generated from the 3D histological data of the heads of mice (C57 Bl/6J) ranging from stages embryonic (E) to postnatal (P) stages E15 to P20 using the reconstruction software 3-Matic. Bone, dentin, enamel and dental follicle around the primordia were generated and converted into 3D FE models. Models were imported into the FE software package MSC.Marc/Mentat. As material parameters of embryonic dentine, pulp, enamel, dental follicle, and bony structures basically are unknown, these were varied from 1% to 100% of the corresponding known material parameters for humans and a sensitivity analysis was performed. Surface loads were applied to the outside surface of dental follicle ranging from 0.1 to 5.0N/mm2. The validity of the model was analysed by comparing the activity pattern of the alveolar bone as determined in the histological study with the loading pattern from the numerical analysis. The results show that when varying the surface loads, the distribution of shear stresses remained same, and while varying the material properties of the hard tissues, the location of highest shear stresses remained stable. Comparison of the histologically determined growth regions with the distribution of shear stresses computed in the numerical model showed a very close agreement. The results provide a strong proof to support Blechschmidt's hypothesis that the bone in general is created under the influence of shear forces.


Asunto(s)
Desarrollo Óseo/fisiología , Mandíbula/crecimiento & desarrollo , Diente Molar/crecimiento & desarrollo , Adulto , Proceso Alveolar/crecimiento & desarrollo , Animales , Animales Recién Nacidos , Esmalte Dental/crecimiento & desarrollo , Pulpa Dental/crecimiento & desarrollo , Saco Dental/crecimiento & desarrollo , Dentina/crecimiento & desarrollo , Femenino , Análisis de Elementos Finitos , Humanos , Imagenología Tridimensional , Mandíbula/embriología , Ratones , Ratones Endogámicos C57BL , Diente Molar/embriología , Embarazo , Erupción Dental
4.
Biomed Tech (Berl) ; 64(1): 103-110, 2019 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-29420301

RESUMEN

Poor stability of a complete denture is a common problem due to bone atrophy of the edentulous ridge. The aim of the present study was to analyze denture stability after receiving implants and to study the biomechanical properties of denture implants and the bone bed using conventional or mini implants. Five models based on computed tomography (CT) data of edentulous patients were created. The overdentures' connection to the implants was assured by means of ball head abutments and rubber rings. In three models, the denture was supported by two to four conventional implants and in two models, the overdenture was supported by three to five mini implants. The dentures were loaded according to the individual biting forces which was clinically measured by means of pressure sheets. After implantation, the biting forces and displacements of overdentures increased in comparison to complete dentures. Displacements and stresses were higher with mini implants than with conventional ones. Stress in the implants was markedly below the yield stress of titanium grade 5 (880 MPa). An increase in the stress in the bone around the implants was noticed as compared to the situation with complete dentures which was below the physiological range of bone loading (<4 MPa).


Asunto(s)
Implantes Dentales , Análisis del Estrés Dental/instrumentación , Mandíbula/fisiopatología , Fuerza de la Mordida , Análisis del Estrés Dental/métodos , Retención de Dentadura , Dentadura Completa , Prótesis de Recubrimiento , Humanos
5.
Clin Oral Investig ; 23(2): 771-777, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29850956

RESUMEN

OBJECTIVES: The aim of the present study was to find out whether the high-performance polymer PEKK is an equivalent alternative compared to cobalt chrome (CoCr)-made restorations, regarding to biocompatibility, stability, and comfort. MATERIALS AND METHODS: Twenty-two patients (m, 10; f, 12) who were indicated for a long-term temporary-fixed restoration were included. They were randomized through a lottery procedure into two groups: the first group was restored with veneered PEKK-made crowns and bridges (Pekkton ivory), while the second group was restored with veneered CoCr crowns. Clinical parameters (plaque index (PI), probing depth (PD), fracture, and chipping) were documented in a period of 3-5 months from the insertion of restoration. Furthermore, every patient completed the OHIP-14 questionnaire. An exchange of the restorations from the first to the alternative material was performed after a period of 3-5 months. RESULTS: All patients showed an improvement of the oral hygiene and probing depth after insertion of the temporary restorations. However, there were no significant differences between PEKK and CoCr-made restorations (P > 0.05). There was no chipping after 5 months for both kinds of materials. There was a noticeable reduction of pain and discomfort of patients after insertion of temporary restorations. However, there were no significant differences between the two materials (P > 0.05). CONCLUSIONS: PEKK-made temporary restorations offer a good and stable alternative to CoCr-made restorations. They have a high aesthetical advantage over CoCr restoration. CLINICAL RELEVANCE: Esthetic and price-efficient temporary crowns can be offered for the patient during periodontal therapy to improve its success, in particular by improving the oral hygiene.


Asunto(s)
Coronas , Diseño de Prótesis Dental , Restauración Dental Provisional , Cetonas/química , Polietilenglicoles/química , Adulto , Anciano , Benzofenonas , Materiales Biocompatibles/química , Aleaciones de Cromo/química , Materiales Dentales/química , Fracaso de la Restauración Dental , Diseño de Dentadura , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Polímeros , Encuestas y Cuestionarios
6.
PLoS One ; 13(7): e0200957, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30063761

RESUMEN

Dental implants are important tools for restoring the loss of teeth. The rapid growth and periodic regeneration of antlers make Sika deer a good and less invasive alternative model for studying bone remodelling in mammals. We developed a special loading device for antlers and analysed the bone reaction around unloaded implants and under immediate loading conditions until osseointegration occurred. In micro-computed tomography images, the density of antler tissue around the implants increased as the loading time increased. This finding was histologically confirmed by the good osseointegration observed in unloaded and loaded specimens. Antler tissue displays a similar healing process to human bone. The use of an antler model is a promising alternative for implant studies that does not require animal sacrifice.


Asunto(s)
Cuernos de Venado/fisiología , Ciervos/anatomía & histología , Implantes Dentales , Cicatrización de Heridas , Animales , Cuernos de Venado/diagnóstico por imagen , Conducta Animal , Fenómenos Biomecánicos , Densidad Ósea , Masculino , Proyectos Piloto , Soporte de Peso , Microtomografía por Rayos X
7.
Med Eng Phys ; 59: 8-14, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-30017665

RESUMEN

This study aimed to compare biomechanical characteristics of immediately loaded (IL) and osseointegrated (OS) dental implants inserted into Sika deer antler and lay a foundation for developing an alternative animal model for dental implants studies. Two implants per antler were inserted. One implant was loaded immediately via a self-developed loading device; the other was submerged and unloaded as control. IL implants were harvested after different loading periods. The unloaded implants were collected after OS and the shedding of antler. Specimens were scanned by µCT scanner and finite element models were generated. A vertical force of 10 N was applied on the implant. The mean values of maximum displacements, stresses and strains were compared. The results showed that the density of antler tissue around the implants dramatically increased as the loading time increased. After shedding the antler, 3 pairs of antlers were collected and the density of antler tissue remained in a similar value in all specimens. The maximum values of displacement and stresses in implant and stresses and strains in antler tissue were significantly different among OS models. In one antler, all the biomechanical parameters of IL model were significantly higher than those of OS model of the same animal (P < 0.05) and wider distributions were obtained from IL model. It can be concluded that implants inserted into Sika deer antler might not disturb the growth and calcification process of antler and the use of Sika deer antler model is a promising alternative for implant studies that does not require animal sacrifice.


Asunto(s)
Cuernos de Venado/fisiología , Ciervos , Implantes Dentales , Fenómenos Mecánicos , Oseointegración , Animales , Densidad Ósea , Módulo de Elasticidad , Análisis de Elementos Finitos , Masculino , Estrés Mecánico , Soporte de Peso
8.
Comput Methods Biomech Biomed Engin ; 21(4): 359-369, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29658297

RESUMEN

This study combines finite element method and animal studies, aiming to investigate tissue remodelling processes around dental implants inserted into sika deer antler and to develop an alternative animal consuming model for studying bone remodelling around implants. Implants were inserted in the antlers and loaded immediately via a self-developed loading device. After 3, 4, 5 and 6 weeks, implants and surrounding tissue were taken out. Specimens were scanned by µCT scanner and finite element models were generated. Immediate loading and osseointegration conditions were simulated at the implant-tissue interface. A vertical force of 10 N was applied on the implant. During the healing time, density and Young's modulus of antler tissue around the implant increased significantly. For each time point, the values of displacement, stresses and strains in the osseointegration model were lower than those of the immediate loading model. As the healing time increased, the displacement of implants was reduced. The 3-week immediate loading model (9878 ± 1965 µstrain) illustrated the highest strains in the antler tissue. Antler tissue showed similar biomechanical properties as human bone in investigating the bone remodelling around implants, therefore the use of sika deer antler model is a promising alternative in implant biomechanical studies.


Asunto(s)
Cuernos de Venado/fisiología , Remodelación Ósea , Ciervos/anatomía & histología , Implantes Dentales , Análisis Numérico Asistido por Computador , Animales , Densidad Ósea , Módulo de Elasticidad , Análisis de Elementos Finitos , Masculino , Oseointegración , Estrés Mecánico , Soporte de Peso
9.
Biomed Tech (Berl) ; 62(4): 393-405, 2017 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-28358711

RESUMEN

Mini dental implants (MDI) were once thought of as transitional implants for treatment in selected clinical situations. Their reduced diameter makes them a very attractive option for patients with poor tolerance to maxillary and mandibular prostheses. Using the method of finite element analysis, a series of different designed MDI prototypes have been investigated. The prototypes differed in the geometry of implant body and/or design of implant head. The load transfer of the implant prototypes to the idealised alveolar bone has been regarded and the prototypes have been compared to each other and to a number of standard commercial implants. The prototype models have been virtually placed in the idealised bone with a cortical thickness of 1.5 mm and loaded laterally 30° from the implant's long axis. The condition of immediate loading was assumed for the numerical analyses through defining a contact interface between the implant and bone bed. The numerical analysis in this study showed that the design of the investigated prototype MDI of group 3 (mini-ball head) is the most advantageous design.


Asunto(s)
Fuerza Compresiva/fisiología , Implantes Dentales , Diseño de Prótesis Dental/métodos , Análisis del Estrés Dental/métodos , Maxilar/cirugía , Diente/fisiología , Diente/cirugía , Análisis de Elementos Finitos , Humanos , Maxilar/fisiología
10.
Biomed Tech (Berl) ; 62(1): 103-108, 2017 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-27071143

RESUMEN

Small diameter (mini) dental implants have become more popular in recent years as alternatives to classical implant treatment in clinical cases with critical bony situations. However, an in-depth scientific analysis of the mechanical and biomechanical effects of small diameter implants has not yet been published. The aim of the present study was to investigate experimentally different commercial mini implants by measuring their displacements under immediate loading. Twelve commercially available mini implants were measured. Implants were inserted into porcine mandibular segments and loaded by means of a predefined displacement of 0.5 mm of the loading system. The implants were loaded at an angle of 30° to the implant long axis using the self-developed biomechanical hexapod measurement system. Implant displacements were registered. The experimental results were compared to the numerical ones from a previous study. Measured implant displacements were within the range of 39-194 µm. A large variation in the displacements was obtained among the different implant systems due to the different designs and thread profiles. Comparing experimental and numerical results, the displacements that were obtained numerically were within the range of 79-347 µm. The different commercial mini implants showed acceptable primary stability and could be loaded immediately after their insertion.


Asunto(s)
Implantación Dental Endoósea/normas , Implantes Dentales , Diseño de Prótesis Dental/métodos , Análisis del Estrés Dental/métodos , Mandíbula/fisiología , Animales , Implantación Dental Endoósea/métodos , Implantes Dentales/normas , Diseño de Prótesis Dental/normas , Humanos , Mandíbula/química , Porcinos
11.
J Prosthet Dent ; 117(2): 239-246.e2, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27671375

RESUMEN

STATEMENT OF PROBLEM: Conventional dental implants are not applicable in the mandibular interforaminal region if bone volume is limited. Mini-dental implants offer an alternative means of supporting mandibular overdentures in a narrow residual ridge, without additional surgery. PURPOSE: The purpose of this nonrandomized clinical trial was to compare the ability of mini-dental implants with that of conventional dental implants in supporting mandibular overdentures during a 2-year clinical follow-up. Bone quality, bone resorption, implant stability, and oral health were assessed radiographically. MATERIAL AND METHODS: A total of 32 participants with edentulism were included. Twenty-two participants (99 implants) received 4 to 5 mini-dental implants (diameter: 1.8-2.4 mm; length: 13-15 mm, study group), and 10 participants (35 implants) received 2 to 4 conventional dental implants (diameter: 3.3-3.7 mm; length: 11-13 mm, control group). The selection of the participants in the study or control group was based on the available bone volume in the mandible. The selection was not randomized. The density of cortical bone thickness was measured in Hounsfield units (HU) from computed tomography data, and patients were followed for 2 years. The participants were examined 3, 6, 12, and 24 months after surgery. Primary stability immediately after the insertion of dental implants (Periotest), secondary stability 6 months after implantation, modified plaque, bleeding on probing indices, and probing depth were measured and analyzed statistically (α=.05). RESULTS: The mean HU value 6 months after implantation in the participants who received mini-dental implants was significantly (P=.035) higher (1250 HU) than that in the participants who received conventional dental implants (1100 HU). The probing depths around the conventional dental implants (1.6 and 1.8 mm, respectively) were significantly higher than those around the mini-dental implants (1.3 and 1.2 mm, respectively) 12 and 24 months after surgery, respectively (P<.001). The mean primary and secondary stability values for conventional dental implants were -4.0 and -4.9, respectively. The primary and secondary stability values for the mini-dental implants were -0.3 and -1.4, respectively. The Periotest values of the primary (measured immediately after implant insertion) and secondary implant stabilities (measured 6 months after implant insertion) were significantly higher for the conventional dental implants than for the mini-dental implants (P<.001). CONCLUSIONS: Based on this 2-year clinical trial, patients receiving mini-dental implants had clinical outcomes similar to those of patients receiving conventional dental implants to support overdenture prostheses.


Asunto(s)
Prótesis Dental de Soporte Implantado , Prótesis de Recubrimiento , Anciano , Anciano de 80 o más Años , Pérdida de Hueso Alveolar/diagnóstico por imagen , Implantación Dental Endoósea/métodos , Prótesis Dental de Soporte Implantado/métodos , Dentadura Completa Inferior , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
12.
Ann Anat ; 208: 103-108, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27471005

RESUMEN

The aim of the present study has been to analyze the influence of residual root number and bone density on the loading distribution of restorations combining implant and residual tooth after tooth hemisection using finite element analysis. Based on the image data of two patients, one has one distal root and the other has two distal roots in the mandibular right first molar, eight models were created (four models for each patient): a single crown was placed on the implant and residual tooth in two different bone densities; two separate crowns for the implant and residual tooth in two different bone densities. Vertical force of 100-N was applied on the crowns. The results show that the increase in number of residual roots decreased the magnitude of all biomechanical parameters. Higher values were observed in models with low bone density, especially in one distal root models. The maximum values of strains in spongious bone with the model (one distal root, low spongious bone density, a single crown was placed on the implant and residual tooth) even reached 9000µstrain. From a biomechanical point of view, when two residual roots exist, a single crown placed on the implant and distal half of the molar or two separate crowns for them seem to be an acceptable treatment option, regardless of the bone density. If there is one residual root and the bone density is low, the prosthesis which combines implant with the root might not be used.


Asunto(s)
Fuerza de la Mordida , Implantes Dentales de Diente Único , Diente Molar/fisiología , Diente Molar/cirugía , Técnica de Perno Muñón/instrumentación , Raíz del Diente/fisiología , Densidad Ósea/fisiología , Terapia Combinada/instrumentación , Terapia Combinada/métodos , Fuerza Compresiva/fisiología , Coronas , Análisis del Estrés Dental/métodos , Análisis de Elementos Finitos , Humanos , Diente Molar/anatomía & histología , Procedimientos Quirúrgicos Preprotésicos Orales/instrumentación , Procedimientos Quirúrgicos Preprotésicos Orales/métodos , Estrés Mecánico , Resistencia a la Tracción/fisiología , Raíz del Diente/anatomía & histología , Raíz del Diente/cirugía , Resultado del Tratamiento
13.
Ann Anat ; 206: 96-103, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26851558

RESUMEN

Tooth hemisection preserves partial tooth structure and reduces the resorption of alveolar bone. The aim of this study was to analyze the feasibility of preserving a molar after hemisection and inserting a dental implant with different prosthetic superstructures by means of finite element analysis. First, the distance between the root of the mandibular second premolar and the distal root of the first molar were measured in 80 cone beam computed tomography (CBCT) data sets. Based on these data, the lower right posterior jaw segment was reconstructed and the geometries of the appropriate implant were imported. Four models were created: (1) Hemi-1: An implant (3.7×9mm) replaced the mesial root of the molar, and a single crown was placed on the implant and residual tooth. (2) Hemi-2: Two separate crowns were generated for the implant and the residual tooth. (3) Single: An implant (5.5×9mm) with crown replaced the whole molar. (4) FPD: A 3-unit fixed partial denture combined the distal residual part of the molar and premolar. The results indicated that stresses in the cortical bone and strains in the majority region of the spongious bone were below the physiological upper limits. There were higher stresses in implant with the Hemi-1 and Single models, which had the same maximum values of 45.0MPa. The FPD models represented the higher values of stresses in the teeth and strains in PDL compared to other models. From a biomechanical point of view, it can be concluded that a combination of an implant and residual molar after tooth hemisection is an acceptable treatment option.


Asunto(s)
Coronas , Diseño de Prótesis Dental/métodos , Modelos Biológicos , Diente Molar/fisiopatología , Diente Molar/cirugía , Procedimientos Quirúrgicos Preprotésicos Orales/instrumentación , Adolescente , Adulto , Terapia Combinada/instrumentación , Terapia Combinada/métodos , Simulación por Computador , Diseño Asistido por Computadora , Implantes Dentales de Diente Único , Análisis de Falla de Equipo , Femenino , Análisis de Elementos Finitos , Humanos , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Preprotésicos Orales/métodos , Radiografía Dental , Tomografía Computarizada por Rayos X , Adulto Joven
14.
Eur J Orthod ; 38(3): 300-7, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26174769

RESUMEN

INTRODUCTION: Biomechanical analysis of orthodontic tooth movement is complex, as many different tissues and appliance components are involved. The aim of this finite element study was to assess the relative effect of material alteration of the various components of the orthodontic appliance on the biomechanical behaviour of tooth movement. METHODS: A three-dimensional finite element solid model was constructed. The model consisted of a canine, a first, and a second premolar, including the surrounding tooth-supporting structures and fixed appliances. The materials of the orthodontic appliances were alternated between: (1) composite resin or resin-modified glass ionomer cement for the adhesive, (2) steel, titanium, ceramic, or plastic for the bracket, and (3) ß-titanium or steel for the wire. After vertical activation of the first premolar by 0.5mm in occlusal direction, stress and strain calculations were performed at the periodontal ligament and the orthodontic appliance. RESULTS: The finite element analysis indicated that strains developed at the periodontal ligament were mainly influenced by the orthodontic wire (up to +63 per cent), followed by the bracket (up to +44 per cent) and the adhesive (up to +4 per cent). As far as developed stresses at the orthodontic appliance are concerned, wire material had the greatest influence (up to +155 per cent), followed by bracket material (up to +148 per cent) and adhesive material (up to +8 per cent). LIMITATIONS: The results of this in silico study need to be validated by in vivo studies before they can be extrapolated to clinical practice. CONCLUSION: According to the results of this finite element study, all components of the orthodontic fixed appliance, including wire, bracket, and adhesive, seem to influence, to some extent, the biomechanics of tooth movement.


Asunto(s)
Diseño de Aparato Ortodóncico , Soportes Ortodóncicos , Alambres para Ortodoncia , Técnicas de Movimiento Dental/instrumentación , Diente Premolar/fisiología , Fenómenos Biomecánicos , Resinas Compuestas , Simulación por Computador , Cementos Dentales/química , Análisis de Elementos Finitos , Humanos , Ensayo de Materiales/métodos , Modelos Anatómicos , Modelos Dentales , Ligamento Periodontal/fisiología , Estrés Mecánico , Titanio
15.
Ann Anat ; 199: 3-8, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25770887

RESUMEN

The bone bed around dental implants is influenced by implant and augmentation materials, as well as the insertion technique used. The primary influencing factors include the dental implant design, augmentation technique, treatment protocol, and surgical procedure. In addition to these treatment-related factors, in the literature, local and systemic factors have been found to be related to the bone stability around implants. Bone is a dynamic organ that optimises itself depending on the loading condition above it. Bone achieves this optimisation through the remodelling process. Several studies have confirmed the importance of the implant design and direction of the applied force on the implant system. Equally dispersed strains and stresses in the physiological range should be achieved to ensure the success of an implant treatment. If a patient wishes to accelerate the treatment time, different protocols can be chosen. However, each one must consider the amount and quality of the available local bone. Immediate implantation is only successful if the primary stability of the implant can be provided from residual bone in the socket after tooth extraction. Immediate loading demands high primary stability and, sometimes, the distribution of mastication forces by splinting or even by inserting additional implants to ensure their success. Augmentation materials with various properties have been developed in recent years. In particular, resorption time and stableness affect the usefulness in different situations. Hence, treatment protocols can optimise the time for simultaneous implant placements or optimise the follow-up time for implant placement.


Asunto(s)
Huesos/fisiología , Implantes Dentales , Aumento de la Cresta Alveolar , Animales , Desarrollo Óseo , Implantación Dental Endoósea , Diseño de Prótesis Dental , Prótesis Dental de Soporte Implantado , Humanos , Carga Inmediata del Implante Dental
16.
Ann Anat ; 199: 52-7, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-24690291

RESUMEN

Understanding the changes in bone density after insertion of dental implants and their relation to immediate loading is essential to achieving improvements in their survival rate. Histological investigations of the bone bed in humans are limited, which in turn hampers opportunities to deepen knowledge about the remodelling process around dental implants. The aim of the present study was to follow the change in bone density by measuring the grey values of cone beam computed tomography (CBCT) at different periods subsequent to implant insertion. The CBCTs of 20 individual immediately loaded implants were evaluated at three time points: prior to surgery, one month following, and six months after the operation. The grey values were measured at different regions around the implants. Reduction in the grey values was observed with respect to the reference values after one month and six months from implant insertion in the apical, middle, and cervical regions. No correlation was detected either between the change in grey values and drilling method or with the measured primary and secondary stabilities by Osstell ISQ instrument. Cone beam computed tomography can be used as a qualitative method to support clinical follow up and monitor the changes in bone density around implants in critical cases.


Asunto(s)
Densidad Ósea/fisiología , Implantes Dentales , Carga Inmediata del Implante Dental , Adulto , Artefactos , Desarrollo Óseo , Huesos/anatomía & histología , Tomografía Computarizada de Haz Cónico , Implantación Dental Endoósea , Implantes Dentales de Diente Único , Femenino , Humanos , Masculino , Mandíbula/diagnóstico por imagen , Persona de Mediana Edad , Valores de Referencia , Titanio , Adulto Joven
17.
Ann Anat ; 199: 58-66, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-24877686

RESUMEN

The rigidity of framework materials and overload of the implant system directly affect the final transferred load of the bone around implants. The aim of the present study has been to analyse the influence of framework materials on the transferred load to the implant system and the surrounding bone. A finite element model of a long-span cementable implant-supported fixed prosthesis was created with two coping layers (gold and hybrid composite) to optimise the fitting of the prosthesis to the abutments. Three framework materials were analysed: titanium, gold alloy, and zirconia. The connection screws were first preloaded with 200 N. The framework was then loaded with 500 N vertically and at 30° to the framework long axis. Two loading conditions were considered: at the mesial and distal boundaries of the framework and at the centre of the framework. The stresses and strains within the framework materials and bone bed around the supporting implants were analysed. The region and angle of load applications showed an obvious effect on the values of the stresses and strains within the framework itself and, consequently, their distribution in the implant system and surrounding bone. A correlation of the framework material and stresses of the coping materials was observed as well. The gold framework showed acceptable values of stress within the cortical bone (92 MPa and 89 MPa with 30° loading at two points and at the centre, respectively) in comparison to titanium (92 MPa and 113 MPa) and zirconia (88 MPa and 115 MPa).


Asunto(s)
Cementos para Huesos , Tornillos Óseos , Implantes Dentales , Prótesis Dental de Soporte Implantado , Implantación de Prótesis/métodos , Aleaciones , Materiales Biocompatibles , Fenómenos Biomecánicos , Huesos/fisiología , Resinas Compuestas , Análisis de Elementos Finitos , Oro , Mandíbula/cirugía , Oseointegración , Titanio , Circonio
18.
Biomed Tech (Berl) ; 59(6): 507-13, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25153205

RESUMEN

The use of short implants has increased widely within the last years. However, the stability of these implants has not yet been comprehensively investigated, in particular the difference in geometry and dimension of short implants. The aim of the present study was to investigate experimentally the difference of the secondary stability of different commercial short implants by measuring their displacements. Eleven implant geometries were investigated in this study. A total of 22 implants were inserted in porcine rib segments, two implants for each system. Implant displacements were measured using a self-developed biomechanical hexapod measurement system (HexMeS). The highest displacement was observed with Straumann BL NC 3.3×8.0 mm (266 µm), followed by Straumann Standard 4.1×6.0 mm (156 µm), while the lowest displacement of 61 µm was shown by Dentaurum type 1 implant (4.2×5.0 mm). No obvious difference of displacements was observed between hammered and screw-shaped implants with relevant dimensions. The experimental results were in good agreement with the numerical ones (19-42%) for Dentaurum implants. However, a difference of 70-80% was obtained for the Astra implant (4.0×6.0 mm) and Bicon implant (6.0×5.7 mm). The geometry of short implants directly affects their stability within the bone.


Asunto(s)
Tornillos Óseos , Retención de Prótesis Dentales/instrumentación , Prótesis Dental de Soporte Implantado , Análisis del Estrés Dental/métodos , Costillas/fisiología , Costillas/cirugía , Animales , Diseño de Prótesis Dental , Retención de Prótesis Dentales/métodos , Análisis de Falla de Equipo , Fricción , Técnicas In Vitro , Movimiento (Física) , Porcinos
19.
Biomed Tech (Berl) ; 59(3): 203-12, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24695023

RESUMEN

Self-tapping dental implants offer the advantage of shortening the surgical insertion time of the implants and improve primary stability in poor bone quality. Using finite element analysis, a series of self-tapping implants with different diameters and lengths have been analysed with respect to their load transfer to the alveolar bone under axial and 45° loading conditions with a total force of 300 N. The implants were inserted in idealised bone beds with cortical thicknesses of 2 and 3 mm. The implants were considered to have osseointegrated condition. A linear decrease of the maximum stresses and strains in the bone around the implants was observed by increasing the diameter of the implants from 3.7 to 5.5 mm regardless of the length of these implants. Lateral loading of the implants caused a critical increase of the stresses and strains in the bone, in particular with the thin cortical layer of 2 mm. The determined biomechanical characteristics of the self-tapping implants showed their applicability in different bone qualities even with extreme reduced length of 7 mm.


Asunto(s)
Fuerza de la Mordida , Tornillos Óseos , Implantes Dentales , Retención de Prótesis Dentales/instrumentación , Análisis del Estrés Dental/métodos , Maxilar/fisiología , Fuerza Compresiva/fisiología , Simulación por Computador , Diseño de Prótesis Dental , Módulo de Elasticidad , Análisis de Falla de Equipo , Análisis de Elementos Finitos , Fricción , Humanos , Maxilar/cirugía , Modelos Biológicos , Oseointegración/fisiología , Estrés Mecánico , Torque
20.
Biomed Tech (Berl) ; 59(1): 1-5, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24293447

RESUMEN

In recent years, the application of small-diameter and mini dental implants to support removable and fixed prosthesis has dramatically increased. However, the success of these implants under functional biting forces and the reaction of the bone around them need to be analyzed. This review was aimed to present studies that deal with the fatigue life of small-diameter and mini dental implants under normal biting force, and their survival rate. The numerical and experimental studies concluded that an increase in the risk of bone damage or implant failure may be assumed in critical clinical situations and implants with <3 mm diameter have a risk of fracture in clinical practice. The survival rate of the small-diameter and mini dental implants over 5 years was 98.3-99.4%.


Asunto(s)
Fuerza de la Mordida , Fuerza Compresiva/fisiología , Implantes Dentales , Análisis del Estrés Dental/métodos , Maxilares/fisiología , Resistencia a la Tracción/fisiología , Soporte de Peso/fisiología , Análisis de Falla de Equipo , Fricción , Miniaturización , Procedimientos Quirúrgicos Ortognáticos , Diseño de Prótesis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA