Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Mol Imaging Radionucl Ther ; 23(1): 16-20, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24653930

RESUMEN

OBJECTIVE: SUVmax is often calculated at FDG PET examinations in systematic studies as well as at clinical examinations. Since SUVmax represents a very small portion of a lesion it may be questioned how statistically reliable the figure is. This was studied by assessing the repeatability of SUVmax between two FDG acquisitions acquired immediately upon each other in patients with chest lesions. METHODS: In 100 clinical patients with a known chest lesion, two identical 3 min PET registrations (PET1 and PET2, respectively) were initiated within 224±31 sec of each other. The difference in SUVmax between the lesion for the two PET scans (ΔSUVmax) was calculated and the uncertainty expressed as the coefficient of variation, CV (%). The correlation between ΔSUVmax and the lowest SUVmax from PET1 or PET2, the approximate metabolic lesion volume, the time from FDG injection to PET1 and the time between PET1 and PET2, respectively, was also assessed. RESULTS: In 56 patients SUVmax increased at the second acquisition and in 44 patients it decreased. Mean of SUVmax was 7.8±6.1 and 7.8±6.2 for PET1 and PET2, respectively. The mean percentage difference was 0.9±7.8. The difference was not significant (p=0.20). CV gave an uncertainty of 4.3% between the two measurements which is a strong indicator of equivalence. There was no correlation between ΔSUVmax and any of the assessed four parameters. The difference between the acquisitions, 0.9%, was much lower compared to the 3 previous published similar, but more restricted studies where the difference was 2.5-8.2%. CONCLUSION: From camera and computational perspectives, SUVmax is a stable parameter Conflict of interest:None declared.

2.
J Nucl Med Technol ; 42(1): 33-6, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24436472

RESUMEN

UNLABELLED: Diagnosis of new bone growth in patients with compound tibia fractures or deformities treated using a Taylor spatial frame is difficult with conventional radiography because the frame obstructs the images and creates artifacts. The use of Na(18)F PET studies may help to eliminate this difficulty. METHODS: Patients were positioned on the pallet of a clinical PET/CT scanner and made as comfortable as possible with their legs immobilized. One bed position covering the site of the fracture, including the Taylor spatial frame, was chosen for the study. A topogram was performed, as well as diagnostic and attenuation correction CT. The patients were given 2 MBq of Na(18)F per kilogram of body weight. A 45-min list-mode acquisition was performed starting at the time of injection, followed by a 5-min static acquisition 60 min after injection. The patients were examined 6 wk after the Taylor spatial frame had been applied and again at 3 mo to assess new bone growth. RESULTS: A list-mode reconstruction sequence of 1 × 1,800 and 1 × 2,700 s, as well as the 5-min static scan, allowed visualization of regional bone turnover. CONCLUSION: With Na(18)F PET/CT, it was possible to confirm regional bone turnover as a means of visualizing bone remodeling without the interference of artifacts from the Taylor spatial frame. Furthermore, dynamic list-mode acquisition allowed different sequences to be performed, enabling, for example, visualization of tracer transport from blood to the fracture site.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Tomografía de Emisión de Positrones/métodos , Fluoruro de Sodio , Adulto , Artefactos , Humanos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Radioisótopos de Sodio
3.
J Autism Dev Disord ; 42(2): 313-8, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21487836

RESUMEN

Specific biological markers for autism spectrum disorder (ASD) have not yet been established. Functional studies have shown abnormalities in the anatomo-functional connectivity of the limbic-striatal "social" brain. This study aimed to investigate regional cerebral blood flow (rCBF) at rest. Thirteen patients with ASD of normal intelligence and ten IQ-, sex- and age-matched healthy controls (HC) underwent PET/CT using [1-(11)C]butanol, a perfusion tracer. As compared to HC, ASD showed significant CBF increases in the right parahippocampal, posterior cingulate, primary visual and temporal cortex, putamen, caudatus, substantia nigra and cerebellum. No statistically significant correlation between CBF and IQ was found. The limbic, posterior associative and cerebellar cortices showed increased blood flow in ASD, confirming previous findings about the neurobiology of ASD.


Asunto(s)
Encéfalo/diagnóstico por imagen , Circulación Cerebrovascular/fisiología , Trastornos Generalizados del Desarrollo Infantil/diagnóstico por imagen , Inteligencia/fisiología , Adulto , Encéfalo/fisiopatología , Niño , Trastornos Generalizados del Desarrollo Infantil/fisiopatología , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Imagen Multimodal , Tomografía de Emisión de Positrones , Tomografía Computarizada por Rayos X
4.
J Clin Nurs ; 15(3): 301-7, 2006 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-16466479

RESUMEN

AIM: To study the effectiveness of this procedure, an intra-individual pilot study comparing the distribution of an instilled radiolabelled saline solution and an inhaled nebulized radiolabelled saline solution was performed using a scintigraphic technique. BACKGROUND: In patients treated with mechanical ventilation, we have routinely used instillation of saline solution in the endotracheal tube before suctioning with the aim of softening mucus and facilitating removal of secretions. In our experience, the effectiveness of this procedure is doubtful. It may also have adverse effects. METHODS: Nine patients on mechanical ventilation were examined with Single Photon Emission Computed Tomography on the same occasion using both humidification methods. The entire examination was carried out with the patient kept in a constant position in relation to the gamma camera, thereby allowing subtraction of the first registration from the second registration and subsequent evaluation and digital comparison of the two humidification methods. RESULTS: Most of the instilled fluid goes to the posterior portion of the right lower pulmonary lobe. Compared with direct instillation, nebulized solution is more uniformly distributed between and within the lungs. With nebulization, distribution is less influenced by gravitation than with instillation. The aerosol reaches the periphery of the lung to a larger extent. CONCLUSIONS: Through the use of an aerosol with specific size characteristics, it may be possible to optimize the distribution of a fluid in the respiratory tract and achieve a more homogenous humidification. It is recommended to replicate the study using 25 subjects. Relevance to clinical practice. Direct instillation of saline should not be used with mechanical ventilation.


Asunto(s)
Nebulizadores y Vaporizadores , Respiración Artificial/métodos , Cloruro de Sodio/administración & dosificación , Administración por Inhalación , Adulto , Aerosoles , Anciano , Investigación en Enfermería Clínica , Femenino , Gravitación , Humanos , Humedad , Instilación de Medicamentos , Intubación Intratraqueal/métodos , Intubación Intratraqueal/enfermería , Masculino , Persona de Mediana Edad , Proyectos Piloto , Postura , Radiofármacos/administración & dosificación , Radiofármacos/farmacocinética , Respiración Artificial/instrumentación , Cloruro de Sodio/farmacocinética , Succión/métodos , Succión/enfermería , Pentetato de Tecnecio Tc 99m/administración & dosificación , Pentetato de Tecnecio Tc 99m/farmacocinética , Distribución Tisular , Tomografía Computarizada de Emisión de Fotón Único
5.
Eur J Nucl Med Mol Imaging ; 29(1): 67-75, 2002 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-11807609

RESUMEN

The increasing implementation of standardisation techniques in brain research and clinical diagnosis has highlighted the importance of reliable baseline data from normal control subjects for inter-subject analysis. In this context, knowledge of the regional cerebral blood flow (rCBF) distribution in normal ageing is a factor of the utmost importance. In the present study, rCBF was investigated in 50 healthy volunteers (25 men, 25 women), aged 31-78 years, who were examined at rest by means of single-photon emission tomography (SPET) using technetium-99m d, l-hexamethylpropylene amine oxime (HMPAO). After normalising the CBF data, 27 left and 27 right volumes of interest (VOIs) were selected and automatically outlined by standardisation software (computerised brain atlas). The heavy load of flow data thus obtained was reduced in number and grouped in factors by means of principal component analysis (PCA). PCA extracted 12 components explaining 81% of the variance and including the vast majority of cortical and subcortical regions. Analysis of variance and regression analyses were performed for rCBF, age and gender before PCA was applied and subsequently for each single extracted factor. There was a significantly higher CBF on the right side than on the left side ( P<0.001). In the overall analysis, a significant decrease was found in CBF ( P=0.05) with increasing age, and this decrease was particularly evident in the left hemisphere ( P=0.006). When gender was specifically analysed, CBF was found to decrease significantly with increasing age in females ( P=0.037) but not in males. Furthermore, a significant decrease in rCBF with increasing age was found in the brain vertex ( P=0.05), left frontotemporal cortex ( P=0.012) and temporocingulate cortex ( P=0.003). By contrast, relative rCBF in central structures increased with age ( P=0.001). The ability of standardisation software and PCA to identify functionally connected brain regions might contribute to a better understanding of the relationships between rCBF at rest, anatomically defined brain structures, ageing and gender.


Asunto(s)
Circulación Cerebrovascular , Radiofármacos , Exametazima de Tecnecio Tc 99m , Tomografía Computarizada de Emisión de Fotón Único , Adulto , Anciano , Envejecimiento/fisiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valores de Referencia , Descanso , Caracteres Sexuales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA