Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros




Asunto de la revista
Intervalo de año de publicación
1.
Int. braz. j. urol ; 50(3): 277-286, May-June 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1558082

RESUMEN

ABSTRACT Purpose: CT-guided MWA is a safe and effective tool that should be utilized in the treatment of small renal masses (SRMs). We aim to clarify the utility of CT-guided MWA by examining patient outcomes such as recurrence, treatment success, changes in renal function, and complications. Methods: A retrospective review of consecutive patients with SRMs who underwent same day renal mass biopsy (RMB) and CT-guided MWA between 2015 and 2022 was performed. Treatment safety was assessed by 30-day complications according to the Clavien-Dindo system and change in eGFR >30 days post-procedure. Treatment efficacy was defined by local recurrence and incomplete treatment rates and calculated using the Kaplan-Meier method. Results: A total of 108 renal masses were found in 104 patients. The overall complication rate was 7.4% (8/108), of which 4 were major complications (3.7%). For those with renal function available >30 days post ablation, the median eGFR was 47.2 (IQR: 36.0, 57), compared to 52.3 (IQR: 43.7, 61.5) pre-ablation, p<0.0001. 5-year local recurrence free survival was 86%. Among those with biopsy proven malignancy (n= 66), there were five local recurrences (7.54%) occurring at a median of 25.1 months (IQR 19.9, 36.2) and one case (1.5%) of incomplete treatment. Conclusions: As the medical field continues to evolve towards less invasive interventions, MWA offers a valuable tool in the management of renal masses. With low major complication and recurrence rates, our findings support the utility of CT-guided MWA as a tool for treatment of SRMs.

2.
Int Braz J Urol ; 50(3): 277-286, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38598830

RESUMEN

PURPOSE: CT-guided MWA is a safe and effective tool that should be utilized in the treatment of small renal masses (SRMs). We aim to clarify the utility of CT-guided MWA by examining patient outcomes such as recurrence, treatment success, changes in renal function, and complications. METHODS: A retrospective review of consecutive patients with SRMs who underwent same day renal mass biopsy (RMB) and CT-guided MWA between 2015 and 2022 was performed. Treatment safety was assessed by 30-day complications according to the Clavien-Dindo system and change in eGFR >30 days post-procedure. Treatment efficacy was defined by local recurrence and incomplete treatment rates and calculated using the Kaplan-Meier method. RESULTS: A total of 108 renal masses were found in 104 patients. The overall complication rate was 7.4% (8/108), of which 4 were major complications (3.7%). For those with renal function available >30 days post ablation, the median eGFR was 47.2 (IQR: 36.0, 57), compared to 52.3 (IQR: 43.7, 61.5) pre-ablation, p<0.0001. 5-year local recurrence free survival was 86%. Among those with biopsy proven malignancy (n= 66), there were five local recurrences (7.54%) occurring at a median of 25.1 months (IQR 19.9, 36.2) and one case (1.5%) of incomplete treatment. CONCLUSIONS: As the medical field continues to evolve towards less invasive interventions, MWA offers a valuable tool in the management of renal masses. With low major complication and recurrence rates, our findings support the utility of CT-guided MWA as a tool for treatment of SRMs.


Asunto(s)
Técnicas de Ablación , Carcinoma de Células Renales , Ablación por Catéter , Neoplasias Renales , Humanos , Neoplasias Renales/patología , Carcinoma de Células Renales/patología , Microondas/uso terapéutico , Resultado del Tratamiento , Técnicas de Ablación/efectos adversos , Técnicas de Ablación/métodos , Estudios Retrospectivos , Ablación por Catéter/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA