Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Interact Cardiovasc Thorac Surg ; 32(4): 499-505, 2021 04 19.
Artículo en Inglés | MEDLINE | ID: mdl-33881147

RESUMEN

OBJECTIVES: Durability of sutureless aortic bioprosthetic valves remains a major issue. The aim of this study was to assess structural valve deterioration (SVD) and bioprosthetic valve failure (BVF) of the Perceval bioprosthesis using the new proposed standardized definitions. METHODS: All patients who underwent aortic valve replacement with sutureless Perceval S prostheses up to September 2016 were included. Clinical and echocardiographic follow-up was performed. New standardized definitions were used to assess the durability of sutureless bioprosthetic valves. From 2013 to 2016, 214 patients were included. RESULTS: The mean age and EuroSCORE II were 79 years and 2.74. Thirty-day mortality was 0.47%. The survival rate was 96.8%, 88.1% and 85.7% at 1, 3 and 4 years, respectively. The median echocardiographic follow-up was 3.28 years. The mean pressure gradient was 11.3 mmHg. No cases showed evidence of severe SVD, 17 patients had moderate SVD with a mean pressure gradient of 24 mmHg and 8 patients had definite late BVF. The incidence of moderate SVD and BVF at 4 years was 8.8% and 2.9%, respectively. CONCLUSIONS: Mid-term follow-up to 6.3 years after aortic valve replacement with the Perceval bioprosthesis documents favourable haemodynamic and clinical outcomes and low rates of SVD and BVF.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Bioprótesis , Consenso , Humanos , Diseño de Prótesis , Resultado del Tratamiento
2.
Interact Cardiovasc Thorac Surg ; 33(2): 195-202, 2021 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-33792711

RESUMEN

OBJECTIVES: This study aims to evaluate the efficacy, safety and long-term outcomes of a renoprotective non-contrast, transoesophageal echocardiography-guided transapical (TA) transcatheter aortic valve replacement (TAVR) strategy with a balloon-expandable prosthesis, as well as to determine its impact on renal function. METHODS: Between 2009 and 2019, 200 consecutive patients underwent a non-contrast, transoesophageal echocardiography-guided TA TAVR with a balloon-expandable prosthesis. RESULTS: The device success rate was 95.5%. Transoesophageal echocardiography-guided deployment demonstrated a low rate of procedure-related complications: 9.5% of acute kidney injury, 8% postoperative bleeding, 6% low-cardiac output, 4.5% postprocedural aortic regurgitation ≥+2, 4% implantation of permanent pacemaker and 2% stroke. There were no significant differences between preoperative and on discharge estimated glomerular filtration rate (53.9 ± 22.2 vs 54.3 ± 22.9 ml/min/1.73 m2, P = 0.60). Logistic regression analysis confirmed postoperative bleeding as an independent predictor for acute kidney injury (odds ratio (OR) 11.148, 95% confidence interval 3.537-35.140, P < 0.001). In-hospital mortality was 7.5%. The mean follow-up was 48.5 ± 39.9 months. Renal function and patient's chronic kidney disease stage did not significantly vary during follow-up. Long-term cumulative survival at 1, 5 and 10 years was 84.2 ± 0.027%, 42.9 ± 0.038% and 32.5 ± 0.044%, respectively. Renal function affected on neither in-hospital mortality nor long-term survival. CONCLUSIONS: Non-contrast, transoesophageal echocardiography-guided TA TAVR is a safe and reproducible technique with a low incidence of periprocedural complications that avoids the use of contrast and mitigates the incidence of acute kidney injury.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
3.
Interact Cardiovasc Thorac Surg ; 33(2): 173-180, 2021 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-33782703

RESUMEN

OBJECTIVES: This study aims to analyse the risks associated with valve-in-valve procedures for treating structural valve deterioration in Mitroflow bioprostheses, as well as to determine the impact of the original Mitroflow size on the patients' long-term outcomes. METHODS: Between January 2012 and September 2019, 21 patients (61.9% males; mean age 82.4 ± 5.4 years) were treated for Mitroflow deterioration with valve-in-valve procedures (12 transapical and 9 transfemoral). RESULTS: Mean EuroSCORE I and EuroSCORE II were 28.2% ± 13.6% and 10.5% ± 6.1%, respectively. Six patients presented an indexed aortic root diameter <14 mm/m2 and 7 patients a diameter of sinus of Valsalva <30 mm. Implanted transcatheter valve sizes were 20 mm in 6 cases, 23 mm in 14 cases and 26 mm in 1 patient. A Valve Academic Research Consortium-2 complication occurred in 23.8% of cases, including 3 coronary occlusions. In-hospital mortality was 9.5%. The 20 mm transcatheter valves presented significantly higher postoperative peak and mean aortic gradients than other sizes (54.1 ± 11.3 mmHg vs 29.9 ± 9.6 mmHg, P = 0.003; and 29.3 ± 7.7 mmHg vs 17.4 ± 5.9 mmHg, P = 0.015, respectively). There were 12 cases of patient-prosthesis mismatch (57.1%) and 3 cases (14.3%) of severe patient-prosthesis mismatch. Cumulative survival was 85.7% ± 7.6% at 1 year, 74.3% ± 10% at 2 years and 37.1% ± 14.1% at 5 years. CONCLUSIONS: Valve-in-valve procedures with balloon-expandable transcatheter valves associate a high risk of coronary occlusion in patients with indexed aortic root diameter <14 mm/m2 and low coronary ostia <12 mm. Valve-in valve procedures with 20 mm balloon-expandable transcatheter valves in ≤21 mm Mitroflow bioprosthesis leave significant residual transvalvular gradients that might obscure patients' long-term outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Ecocardiografía , Femenino , Fluoroscopía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Diseño de Prótesis , Falla de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
4.
Thorac Cardiovasc Surg ; 67(5): 393-394, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29462824

RESUMEN

We describe the "auto-sliding graft" technique, a different anastomotic option for reconstructive prosthetic procedures on the ascending aorta especially in patients at risk of circulatory arrest with mild aortic dilatation. This simple technique provides not only an important hemostatic reinforcement for the distal aortic graft anastomosis but also a protective effect on the native ascending aorta beyond the suture line.


Asunto(s)
Aorta/cirugía , Implantación de Prótesis Vascular/métodos , Técnicas de Sutura , Anastomosis Quirúrgica , Aorta/diagnóstico por imagen , Aorta/fisiopatología , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Puente Cardiopulmonar , Humanos , Selección de Paciente , Tereftalatos Polietilenos , Diseño de Prótesis , Factores de Riesgo , Resultado del Tratamiento
5.
J Card Surg ; 33(7): 356-362, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29790206

RESUMEN

OBJECTIVES: Bioprostheses with pericardial leaflets mounted externally on the stent pose a high risk for valve-in-valve (ViV) procedures. This study analyzed the efficacy and safety of ViV procedures for treating structural valve deterioration (SVD) in Mitroflow bioprostheses. METHODS: Between January 2012 and August 2017, 11 patients (mean age 80.3 ± 5.6 years) were treated for SVD of Mitroflow bioprostheses with transcatheter ViV procedures (six transapical [TA] and five transfemoral [TF]) using balloon expandable bioprostheses. RESULTS: All patients but one were in NYHA class III-IV. Mean STS PROM, euroSCORE I, and euroSCORE II were 8 ± 6.5%, 27.8 ± 11.5%, and 12 ± 5.9%, respectively. Two patients had a "porcelain aorta." The size of implanted valves were 23 mm in 10 cases and 26 mm in one case. One patient suffered a coronary occlusion during a TF approach. The mean volume of contrast used in TF implants was 163 ± 69.8 mL. No contrast media were used in TA procedures. There was one in-hospital death (10%). At 1 year of follow-up, peak and mean aortic gradients were 25.5 ± 5.8 mmHg and 15.5 ± 5.7 mmHg, respectively. One patient had mild paravalvular regurgitation. Cumulative survival was 90.9% at 1 year, 70.7% at 2 years, and 53% at 3 years. CONCLUSIONS: ViV procedures with balloon-expandable aortic valves provide good hemodynamic and clinical mid-term results for treating patients with a degenerated Mitroflow aortic bioprosthesis. Special care must be taken in small aortic roots, when the stented valve is in the supra-annular position to avoid coronary ostial obstruction.


Asunto(s)
Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Enfermedades de las Válvulas Cardíacas/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Falla de Prótesis/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Enfermedades de las Válvulas Cardíacas/fisiopatología , Hemodinámica , Humanos , Masculino , Seguridad , Stents , Resultado del Tratamiento
6.
Eur J Cardiothorac Surg ; 54(4): 689-695, 2018 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-29659806

RESUMEN

OBJECTIVES: The objective of this study is to compare early and long-term results in terms of survival and aortic complications for traumatic aortic injuries depending on the initial management strategy. METHODS: From January 1980 to January 2017, 101 patients with aortic injuries were divided into 3 groups according to management strategy at admission: 60 patients, conservative management; 26 patients, open surgery and 15 patients, endovascular repair. The groups were similar in terms of gender and trauma severity scores. RESULTS: All but 1 aortic-related complications and aortic-related mortality occurred in the conservative group (11.6% conservative vs 2.4% in both surgical and endovascular groups, P = 0.091). Total follow-up was 1109.27 patient-years. Survival in the conservative, surgical and endovascular group was 71.7%, 80.8% and 79.4% at 1 year, 68.2%, 80.8% and 79.4% at 5 years and 63.9%, 72.7% and 79.4% at 10 years, respectively (log-rank = 0.218). The rate of aortic-related complications was 58.3% in the conservative cohort. Cox regression identified the following risk factors for aortic-related complications: aortic injuries grade >I [odds ratio (OR), 3.05; P = 0.021], Trauma Injury Severity Score >50% (OR 1.21; P = 0.042) and the decade of treatment (OR 0.49; P = 0.011). CONCLUSIONS: Minimal aortic injuries seem to be an amenable target for medical management, but patients remain at risk of developing aortic-related complications. Close, long-term imaging surveillance is mandatory to detect such complications at an early stage.


Asunto(s)
Aorta/lesiones , Tratamiento Conservador/métodos , Manejo de la Enfermedad , Lesiones del Sistema Vascular/terapia , Heridas no Penetrantes/terapia , Enfermedad Aguda , Adulto , Aortografía , Femenino , Humanos , Puntaje de Gravedad del Traumatismo , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , España/epidemiología , Tasa de Supervivencia/tendencias , Resultado del Tratamiento , Lesiones del Sistema Vascular/diagnóstico , Lesiones del Sistema Vascular/mortalidad , Heridas no Penetrantes/diagnóstico
7.
Eur J Heart Fail ; 20(2): 385-394, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-28580728

RESUMEN

AIM: To analyse the incidence, risk factors and clinical outcomes of late graft failure after heart transplantation. METHODS AND RESULTS: We conducted an observational, single-centre study based on 547 patients who underwent cardiac transplantation from 1991 to 2014 and who survived the in-hospital postoperative period. Late graft failure was defined as the first hospitalization due to this condition after discharge. Over a mean follow-up of 8.4 ± 6 years, 178 (32.5%) patients were hospitalized due to late graft failure [incidence rate: 3.6 cases per 100 patient-years, 95% confidence interval (CI) 3.1-4.2]. Pre-transplant diabetes, higher pre-transplant transpulmonary pressure gradient and lower donor-recipient weight ratio were independently associated with higher risk of graft failure. Cardiac allograft vasculopathy, cellular rejection grade ≥1R, and antibody-mediated rejection grade ≥1 were detected in 50.6%, 44.9% and 19.2% patients, respectively, admitted due to graft failure. Left ventricular ejection fraction was ≥50% in 60.1% of these patients. Re-transplant free survival 1, 5, 10 and 15 years after the diagnosis of late graft failure was 72.2%, 38.4%, 18.4%, and 7.5%, respectively; the incidence rate of re-hospitalization due to decompensated heart failure was 40.9 episodes per 100 patient-years (95% CI 36.6-46.1). The need for inotropes, the presence of cardiac allograft vasculopathy, higher creatinine serum levels, lower ejection fraction and lower sodium serum levels were independent predictors of worse outcomes. CONCLUSIONS: Late graft failure is frequent after heart transplantation, as it is associated with poor outcomes. Rejection and cardiac allograft vasculopathy are the most frequent underlying causes.


Asunto(s)
Rechazo de Injerto/epidemiología , Insuficiencia Cardíaca/cirugía , Trasplante de Corazón/efectos adversos , Medición de Riesgo , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/mortalidad , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Factores de Riesgo , España/epidemiología , Tasa de Supervivencia/tendencias , Factores de Tiempo
8.
Rev Esp Cardiol (Engl Ed) ; 70(8): 639-645, 2017 Aug.
Artículo en Inglés, Español | MEDLINE | ID: mdl-28209304

RESUMEN

INTRODUCTION AND OBJECTIVES: To study the prognostic impact of preoperative nutritional status, as assessed through the nutritional risk index (NRI), on postoperative outcomes after heart transplantation (HT). METHODS: We conducted a retrospective, single-center study of 574 patients who underwent HT from 1991 to 2014. Preoperative NRI was calculated as 1.519 × serum albumin (g/L) + 41.7 × (body weight [kg] / ideal body weight [kg]). The association between preoperative NRI and postoperative outcomes was analyzed by means of multivariable logistic regression and multivariable Cox regression. RESULTS: Mean NRI before HT was 100.9 ± 9.9. According to this parameter, the prevalence of severe nutritional risk (NRI < 83.5), moderate nutritional risk (83.5 ≤ NRI < 97.5), and mild nutritional risk (97.5 ≤ NRI < 100) was 5%, 22%, and 10%, respectively. One year post-transplant mortality rates in these 4 categories were 18.2%, 25.3%, 7.9% and 10.2% (P < .001), respectively. The NRI was independently associated with a lower risk of postoperative infection (adjusted OR, 0.97; 95%CI, 0.95-1.00; P = .027) and prolonged postoperative ventilator support (adjusted OR, 0.96; 95%CI, 0.94-0.98; P = .001). Patients at moderate or severe nutritional risk had significantly higher 1-year post-HT mortality (adjusted HR, 1.55; 95%CI, 1.22-1.97; P < .001). CONCLUSIONS: Malnourished patients have a higher risk of postoperative complications and mortality after HT. Preoperative NRI determination may help to identify HT candidates who might benefit from nutritional intervention.


Asunto(s)
Insuficiencia Cardíaca/cirugía , Trasplante de Corazón/efectos adversos , Desnutrición/diagnóstico , Evaluación Nutricional , Femenino , Insuficiencia Cardíaca/mortalidad , Trasplante de Corazón/mortalidad , Humanos , Tiempo de Internación/estadística & datos numéricos , Masculino , Desnutrición/mortalidad , Persona de Mediana Edad , Estado Nutricional , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Disfunción Primaria del Injerto/etiología , Disfunción Primaria del Injerto/mortalidad , Pronóstico , Estudios Retrospectivos , Factores de Riesgo , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/mortalidad , Disfunción Ventricular Derecha/etiología , Disfunción Ventricular Derecha/mortalidad
10.
Rev Esp Cardiol (Engl Ed) ; 69(12): 1160-1166, 2016 Dec.
Artículo en Inglés, Español | MEDLINE | ID: mdl-27597125

RESUMEN

INTRODUCTION AND OBJECTIVES: To assess the potential association between recipient Toxoplasma gondii serostatus and outcomes after heart transplant (HT). METHODS: We conducted a retrospective single-center study of 657 HT recipients from 1991 to 2015. Survival and the incidence of adverse clinical events of T. gondii-seropositive (n = 481) vs T. gondii-seronegative (n = 176) recipients were compared by means of 2 different multivariable Cox regression models. Model 1 included solely age and sex, and model 2 included other potential confounders. RESULTS: Over a median follow-up of 2903 days (interquartile range: 898-4757), 250 seropositive recipients (52%) and 72 seronegative recipients (41%) died. Univariable analysis showed increased posttransplant mortality among T. gondii-seropositive recipients (hazard ratio [HR] = 1.31; 95% confidence interval [95%CI], 1,00-1.70). After multivariable adjustment, the statistical significance of this association was lost (model 1: HR = 1.09; 95%CI, 0.83-1.43; model 2:HR = 1.12; 95%CI, 0.85-1.47). Recipient T. gondii seropositivity was independently associated with an increased risk of acute rejection (model 1: HR = 1.36; 95%CI, 1.06-1.74; model 2: HR = 1.29; 95%CI, 1.01-1.66). Multivariable models showed no statistically significant impact of recipient T. gondii serostatus on the incidence of infection, malignancy, coronary allograft vasculopathy, or the composite outcome of cardiac death or retransplant. No significant association was found between donor-recipient T. gondii serostatus matching and posttransplant outcome. CONCLUSIONS: In this study, recipient T. gondii serostatus was not an independent predictor of long-term post-HT outcome.


Asunto(s)
Rechazo de Injerto/epidemiología , Insuficiencia Cardíaca/cirugía , Trasplante de Corazón , Toxoplasma/inmunología , Toxoplasmosis/epidemiología , Adulto , Anciano , Femenino , Rechazo de Injerto/prevención & control , Humanos , Inmunosupresores/uso terapéutico , Incidencia , Masculino , Persona de Mediana Edad , Mortalidad , Análisis Multivariante , Pronóstico , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Factores de Riesgo , Toxoplasmosis/inmunología
11.
J Card Surg ; 31(5): 264-73, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26991888

RESUMEN

BACKGROUND: This study aims to determine the incidence and causes of structural valve deterioration (SVD) among all models of Mitroflow bioprostheses (A12/LX/DL), as well as to define their long-term clinical and hemodynamic performance. METHODS AND RESULTS: We retrospectively reviewed a series of 1023 patients who underwent aortic valve replacement with Mitroflow bioprostheses between 2001 and 2014. A small aortic root was found in 22.4% of patients. There were two cases of severe patient-prosthesis mismatch. Only 31 patients developed SVD. The rate of incidence was 8.1 cases per 1000 patient-years. Cumulative incidence of SVD was 1.4% and 3% at five and 10 years, respectively. Freedom from SVD was 97.4% and 88.2% at five and 10 years, respectively. Anticalcification phospholipid reduction treatment (PRT) for model DL was a protective factor for SVD. Multivariable analysis confirmed age <70 years and use of 19 mm valve as independent predictors of SVD. Cumulative survival was 76.6% at five years and 42.3% at 10 years (mean follow-up 3.8 ± 3.1 years). In multivariable analysis, neither the use of small aortic prosthesis (p = 0.18) nor the occurrence of SVD (p = 0.85) was found to be independent predictors of long-term survival. CONCLUSIONS: Mitroflow valves demonstrate an acceptable rate of SVD and satisfactory long-term hemodynamic performance, particularly in patients with small aortic roots, age >70 years, and cases with severe left ventricular hypertrophy. PRT might contribute to improved long-term durability. doi: 10.1111/jocs.12726 (J Card Surg 2016;31:264-273).


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Prótesis Valvulares Cardíacas , Hemodinámica , Ensayo de Materiales , Complicaciones Posoperatorias/epidemiología , Anciano , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/fisiopatología , Ecocardiografía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Diseño de Prótesis , Estudios Retrospectivos , España/epidemiología , Factores de Tiempo
12.
J Heart Lung Transplant ; 34(2): 167-74, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25434523

RESUMEN

BACKGROUND: A high frequency of venous thromboembolism (VTE) has been observed after lung, kidney, and liver transplantation. However, data about the incidence of this complication among heart transplant (HT) recipients are lacking. METHODS: We analyzed the incidence, recurrence, and predisposing factors of VTE in a single-center cohort of 635 patients who underwent HT from April 1991 to April 2013. Deep venous thrombosis (DVT) and pulmonary embolism (PE) were considered as VTE episodes. RESULTS: During a median post-transplant follow-up of 8.4 years, 62 VTE episodes occurred in 54 patients (8.5%). Incidence rates of VTE, DVT, and PE were, respectively, 12.7 (95% confidence interval [CI], 9.7-16.3), 8.4 (95% CI, 6.0-11.4), and 7.0 (95% CI 4.8-9.7) episodes per 1,000 patient-years. Incidence rates of VTE during the first post-transplant year and beyond were, respectively, 45.1 (95% CI, 28.9-67.1) and 8.7 (95% CI 6.2-11.2) episodes per 1,000 patient-years. The incidence rate of VTE recurrence after a first VTE episode was 30.5 (95% CI, 13.2-60.2) episodes per 1,000 patient-years. By means of multivariable Cox regression, chronic renal dysfunction, older age, obesity, and the use of mammalian target of rapamycin inhibitors were identified as independent risk factors for VTE among HT recipients. CONCLUSIONS: VTE is a frequent complication after HT, mainly during the first post-operative year. In view of a high recurrence rate, long-term anti-coagulation should be considered in HT recipients who experience a first VTE episode.


Asunto(s)
Trasplante de Corazón/efectos adversos , Complicaciones Posoperatorias , Tromboembolia Venosa/epidemiología , Biopsia , Ecocardiografía , Electrocardiografía , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Miocardio/patología , Pronóstico , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , España/epidemiología , Tasa de Supervivencia/tendencias , Factores de Tiempo , Tromboembolia Venosa/diagnóstico , Tromboembolia Venosa/etiología
13.
J Eval Clin Pract ; 21(1): 34-42, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25040767

RESUMEN

RATIONALE, AIMS AND OBJECTIVES: Transcatheter aortic valve implantation constitutes an example of a technology introduced into the Galician Health Care System basket and subjected to a post-introduction observational study after coverage. This paper aims to describe the process and results of this experience, illustrating the main challenges and opportunities in using these studies for supporting decision making. METHODS: The study protocol was developed by a multidisciplinary team consisting of experts from the Galician HTA Agency (avalia-t), interventional cardiologists and cardiac surgeons. Together they agreed on the information that was relevant and feasible for collection, and planned the study design, data collection and analysis of results. RESULTS: During the 1-year recruitment period, 94 patients underwent percutaneous aortic valve replacement in the three authorized centres. Implantation rate and prosthesis models differed substantially across the centres. Overall, procedural success rate was 96.8% and hospital mortality was 7.4%. Complications during post-surgical admission were recorded in 40.4% of patients. Moderate residual aortic regurgitation was observed in 10% of patients, and the procedure was associated with a stroke rate of 3.3% at 30 days and 5.3% at 1 year. CONCLUSIONS: Post-introduction observation has made it feasible to determine the use of this procedure within the SERGAS context and has enabled the assessment of performance in real-life conditions. The proposed strategic actions and interventions have been drawn up based upon the collective judgement of a group of experienced professionals, and have served to establish recommendations on further research that would be required to optimize health benefits.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/estadística & datos numéricos , Anciano , Anciano de 80 o más Años , Electrocardiografía , Femenino , Mortalidad Hospitalaria , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , España , Factores de Tiempo
14.
J Thorac Cardiovasc Surg ; 148(6): 2845-53.e1, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25131169

RESUMEN

OBJECTIVE: The present study aimed to identify potential differences in hemodynamic performance between the supra-annular CarboMedics Top Hat valve and the intra-annular CarboMedics standard valve in terms of the long-term left ventricular mass reduction and transvalvular gradients. METHODS: We retrospectively reviewed a series of 186 consecutive patients who had undergone aortic valve replacement with a small size mechanical prosthesis at our institution from 2003 to 2013, receiving either a CarboMedics Top Hat valve (53 patients, valve size, 21 mm in 52.8% and 23 mm in 47.2%) or a CarboMedics standard prosthesis (133 patients, valve size, 19 mm in 14.3% and 21 mm in 85.7%). RESULTS: The in-hospital mortality was 9.4% and 11.3% in the Top Hat and standard groups, respectively (P = .71). The mean percentage of left ventricular mass reduction was greater in the Top Hat group (33% ± 15.8% vs 20.1% ± 16.6%, P < .001). The mean postoperative peak aortic gradient was lower in the Top Hat group (19.9 ± 8.9 vs 29.6 ± 8.6 mm Hg; P < .001). Spearman analysis showed a positive correlation between the indexed effective orifice area and the percentage of left ventricular mass reduction (Rho = +0.65, P = .02). The survival in the Top Hat group was 79.7% and 71.7% at 5 and 10 years, respectively. In the standard group, survival was 66.8% and 61.5% at 5 and 10 years, respectively (log-rank test, 0.19). Cox regression demonstrated severe myocardial hypertrophy (hazard ratio, 2.559; 95% confidence interval, 1.095-5.981) as one of the independent predictors of survival. CONCLUSIONS: The Top Hat valve surpasses hemodynamically the intra-annular valve. We suggest the supra-annular Top Hat prosthesis can be especially recommended for patients with a small aortic root and severe myocardial hypertrophy.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Hipertrofia Ventricular Izquierda/fisiopatología , Función Ventricular Izquierda , Remodelación Ventricular , Anciano , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Distribución de Chi-Cuadrado , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Hemodinámica , Mortalidad Hospitalaria , Humanos , Hipertrofia Ventricular Izquierda/diagnóstico , Hipertrofia Ventricular Izquierda/etiología , Hipertrofia Ventricular Izquierda/mortalidad , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Modelos de Riesgos Proporcionales , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , España , Factores de Tiempo , Resultado del Tratamiento
15.
J Thorac Cardiovasc Surg ; 148(6): 3020-6.e1-2, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24974780

RESUMEN

OBJECTIVE: Aortoesophageal and aortobronchial fistulas are uncommon but life-threatening conditions. The present study aimed to identify potential differences in outcomes, depending on the etiology, type, and management of the fistulas, and to determine mortality predictors. METHODS: We retrospectively reviewed a series of 26 consecutive patients with thoracic aorta fistulas admitted to our institution from 1998 to 2013 (18 aortobronchial, 7 aortoesophageal, and 1 combined fistula). RESULTS: The mean age was 61.5 ± 13.4 years, with 22 men. Management was thoracic endovascular aortic repair (TEVAR) in 8, open repair in 7, and conservative in 11. The TEVAR and nonoperative patients were significantly older and presented with more comorbidities. Shock developed in 15 patients and sepsis in 9. The most common radiologic findings were intramural hematoma (65.4%), pseudoaneurysm (53.8%), and bronchial compression (46.20%). Active contrast extravasation (23.1%) and ectopic gas (19.2%) were associated with a worse prognosis. In-hospital mortality was 100% in the conservative group, 37.5% in the TEVAR group, and 14.3% in the open repair group (P = .04). Septic shock was the most common cause of death. The risk factors for in-hospital mortality were hemodynamic instability on admission (P = .02), sepsis (P = .04), and conservative management (P < .001). The overall long-term survival in surgical patients at 1 and 5 years was 66% and 58.7%, respectively. Infectious and malignant etiologies resulted in the worst prognosis. CONCLUSIONS: The outcomes are ultimately conditioned by the etiology of the fistula. Both open and endovascular management of aortic fistulas can prevent death by exsanguination; however, patients remain at high risk of infectious complications. Failure to treat the underlying cause will result in poor midterm outcomes.


Asunto(s)
Enfermedades de la Aorta/terapia , Fístula Bronquial/terapia , Procedimientos Endovasculares , Fístula Esofágica/terapia , Fístula Vascular/terapia , Procedimientos Quirúrgicos Vasculares , Anciano , Enfermedades de la Aorta/diagnóstico , Enfermedades de la Aorta/etiología , Enfermedades de la Aorta/mortalidad , Fístula Bronquial/diagnóstico , Fístula Bronquial/etiología , Fístula Bronquial/mortalidad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Fístula Esofágica/diagnóstico , Fístula Esofágica/etiología , Fístula Esofágica/mortalidad , Femenino , Mortalidad Hospitalaria , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Fístula Vascular/diagnóstico , Fístula Vascular/etiología , Fístula Vascular/mortalidad , Procedimientos Quirúrgicos Vasculares/efectos adversos , Procedimientos Quirúrgicos Vasculares/mortalidad
16.
Interact Cardiovasc Thorac Surg ; 14(6): 773-8, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22437888

RESUMEN

OBJECTIVE Minimal aortic injuries (MAIs) are being recognized more frequently due to the increasing use of high-resolution diagnostic techniques. The objective of this case series review was to report the clinical and radiological characteristics and outcomes of a series of patients with MAI. METHODS From January 2000 to December 2011, 54 major blunt trauma patients were admitted to our institution with traumatic aortic injuries. Nine of them presented with MAI, whereas the remaining 45 patients suffered a significant aortic injury (SAI). RESULTS MAIs accounted for 17% of the overall traumatic aortic injuries in our series. Major trauma patients with MAI and SAI were similar regarding the presence of severe associated non-aortic injuries and the expected mortality calculated by injury severity score, revised trauma score and trauma injury severity score. There were no statistically significant differences in in-hospital mortality between MAI (22.2%) and SAI (30.2%). No death in the MAI group was aortic related, whereas five deaths in the SAI group were caused by an aortic complication. The survival of MAI patients was 77.8% at 1 and 5 years. There was no late mortality among MAI patients. The survival of SAI patients was 69.7% at 1 year and 63.6% at 5 and 10 years. None of the seven surviving patients with MAI presented a progression of the aortic injury. In six patients, the intimal tear completely healed in imaging controls, whereas one patient developed a small saccular pseudoaneurysm. CONCLUSIONS Blunt traumas presenting MAI are as severe as traumas that associate SAI and present similar in-hospital mortality. In contrast to SAI traumas, in-hospital mortality due to MAI is not usually related to the aortic injury, so these injuries are more amenable to a conservative management. It is mandatory to perform a close imaging surveillance to detect early any potential adverse evolution of an MAI. Nevertheless, a balance must be struck between a close serial imaging surveillance and the potentially detrimental effects of obtaining high-resolution additional images.


Asunto(s)
Aorta/lesiones , Lesiones del Sistema Vascular , Heridas no Penetrantes , Adulto , Anciano , Aortografía/métodos , Distribución de Chi-Cuadrado , Ecocardiografía Transesofágica , Femenino , Mortalidad Hospitalaria , Humanos , Puntaje de Gravedad del Traumatismo , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , España , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Lesiones del Sistema Vascular/diagnóstico , Lesiones del Sistema Vascular/mortalidad , Lesiones del Sistema Vascular/terapia , Heridas no Penetrantes/diagnóstico , Heridas no Penetrantes/mortalidad , Heridas no Penetrantes/terapia , Adulto Joven
17.
World J Surg ; 36(7): 1571-80, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22382770

RESUMEN

BACKGROUND: The objectives of this study were to report the clinical and radiological characteristics and outcomes of a series of acute traumatic aortic injuries (ATAIs) with associated injury to major aortic abdominal visceral branches (MAAVBs). METHODS: From January 2000 to August 2011, 10 consecutive major blunt trauma patients with associated ATAI and injury to MAAVBs (group A) and 42 major blunt trauma patients presenting only an ATAI without MAAVB injuries (group B) were admitted to our institution. RESULTS: Overall in-hospital mortality was 32.7%. In-hospital mortality in group A was 40% and in group B it was 31% (p = 0.86). Observed in-hospital mortality was slightly lower than the expected in-hospital mortality in both groups. Mean peak creatine phosphokinase was significantly higher in group A than in group B patients (23,008 ± 33,400 vs. 3,970 ± 3,495 IU/L; p < 0.001). Acute renal injury occurred in 50% of group A and in 26.2% of group B patients. Hemodiafiltration was required in 30% of group A and in 9.5% of group B patients. Median follow-up time was 64 months (range = 1-130 months). Group A survival was 60% at 1, 5 and 10 years. Group B survival was 69% at 1 year and 63.3% at 5 and 10 years (p = 0.15). CONCLUSIONS: Aortic injuries associated with MAAVB injuries in major trauma patients seem to present in a different clinical scenario. These patients present increased risk of rhabdomyolysis, visceral ischemia, and acute renal failure, as well as higher in-hospital mortality. A multidisciplinary approach combining endovascular and open surgical techniques for a staged treatment of these life-threatening aortic and MAAVB injuries is mandatory in this critical subset of trauma patients.


Asunto(s)
Aorta/lesiones , Lesiones del Sistema Vascular/complicaciones , Vísceras/irrigación sanguínea , Heridas no Penetrantes/complicaciones , Adulto , Anciano , Femenino , Mortalidad Hospitalaria , Humanos , Hipotensión/etiología , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Tomografía Computarizada Multidetector , Lesiones del Sistema Vascular/diagnóstico por imagen , Lesiones del Sistema Vascular/mortalidad , Heridas no Penetrantes/diagnóstico por imagen , Heridas no Penetrantes/mortalidad
18.
Rev Esp Cardiol ; 64(3): 193-200, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21316834

RESUMEN

INTRODUCTION AND OBJECTIVES: Our aim was to assess the prognostic value of the INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support) scale in patients undergoing urgent heart transplantation (HT). METHODS: Retrospective analysis of 111 patients treated with urgent HT at our institution from April, 1991 to October, 2009. Patients were retrospectively assigned to three levels of the INTERMACS scale according to their clinical status before HT. RESULTS: Patients at the INTERMACS 1 level (n=31) more frequently had ischemic heart disease (P=.03) and post-cardiothomy shock (P=.02) than patients at the INTERMACS 2 (n=55) and INTERMACS 3-4 (n=25) levels. Patients at the INTERMACS 1 level showed higher preoperative catecolamin doses (P=.001), a higher frequency of use of mechanical ventilation (P<.001), intraaortic balloon (P=.002) and ventricular assist devices (P=.002), and a higher frequency of preoperative infection (P=.015). The INTERMACS 1 group also presented higher central venous pressure (P=.02), AST (P=.002), ALT (P=.006) and serum creatinine (P<.001), and lower hemoglobin (P=.008) and creatinine clearance (P=.001). After HT, patients at the INTERMACS 1 level had a higher incidence of primary graft failure (P=.03) and postoperative need for renal replacement therapy (P=.004), and their long-term survival was lower than patients at the INTERMACS 2 (log rank 5.1, P=.023; HR 3.1, IC 95% 1.1-8.8) and INTERMACS 3-4 level (log rank 6.1, p=0.013; HR 6.8, IC 95% 1.2-39.1). CONCLUSIONS: Our results suggest that the INTERMACS scale may be a useful tool to stratify postoperative prognosis after urgent HT.


Asunto(s)
Tratamiento de Urgencia , Insuficiencia Cardíaca/clasificación , Insuficiencia Cardíaca/cirugía , Trasplante de Corazón , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA