Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Int J Cardiol ; 405: 131989, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38521510

RESUMEN

BACKGROUND: There are limited data regarding whether anemia is associated with adverse clinical outcomes in patients with atrial fibrillation (AF) after percutaneous coronary intervention (PCI). METHODS: Patients with AF undergoing PCI at 15 institutions between January 2015 and March 2021 were included in this analysis. Based on the baseline hemoglobin levels, moderate to severe anemia was defined as hemoglobin levels <11 g/dL, and mild anemia was defined as hemoglobin levels 11-12.9 g/dL for men and 11-11.9 g/dL for women. Clinical outcomes within 1 year, including major adverse cardiovascular events (MACE: all-cause death, myocardial infarction, stent thrombosis, and stroke) and major bleeding events (BARC 3 or 5), were compared among patients with moderate/severe anemia, mild anemia, and no anemia. RESULTS: In a total of 746 enrolled patients, 119 (16.0%) and 168 (22.5%) patients presented with moderate/severe and mild anemia. The incidence of MACE (22.5%, 11.0%, and 9.1%, log-rank p < 0.001), all-cause death (20.0%, 7.2%, and 4.8%, log-rank p < 0.001), and major bleeding events (10.7%, 6.5%, and 2.7%, log-rank p < 0.001) were the highest in the moderate/severe anemia group compared with the mild and no anemia groups. Multivariable Cox regression analyses determined moderate/severe anemia as an independent predictor for MACE (p = 0.008), all-cause death (p = 0.005), and major bleeding events (p = 0.031) at 1 year after PCI. CONCLUSION: Moderate/severe anemia was significantly associated with the higher incidence of MACE and all-cause death as well as major bleeding events compared with mild and no anemia in AF patients undergoing PCI.


Asunto(s)
Anemia , Fibrilación Atrial , Intervención Coronaria Percutánea , Humanos , Intervención Coronaria Percutánea/métodos , Intervención Coronaria Percutánea/efectos adversos , Fibrilación Atrial/complicaciones , Femenino , Masculino , Anciano , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Anciano de 80 o más Años , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Estudios de Seguimiento
2.
J Cardiol ; 82(3): 207-214, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37336423

RESUMEN

BACKGROUND: The efficacy and safety of dual antithrombotic therapy (DAT) with oral anticoagulant and P2Y12 inhibitors (P2Y12i) in patients with atrial fibrillation (AF) undergoing percutaneous coronary intervention (PCI) have not been well investigated. The purpose of this study was first to evaluate clinical outcomes of DAT with P2Y12i compared with triple antithrombotic therapy (TAT), and then to compare DAT with low-dose prasugrel and DAT with clopidogrel, in patients with AF undergoing PCI. METHODS: This study was a multicenter, non-interventional, prospective and retrospective registry. A total of 710 patients with AF undergoing PCI between January 2015 and March 2021 at 15 institutions were analyzed. Clinical outcomes within 1 year, including major adverse cardiovascular events (MACE) and major bleeding events (BARC 3 or 5) were compared between patients receiving DAT (n = 239) and TAT (n = 471), and then, compared among prasugrel-DAT (n = 82), clopidogrel-DAT (n = 157), and TAT. RESULTS: The DAT group showed significantly lower incidence of MACE and major bleeding events compared with the TAT group (log-rank p = 0.013 and 0.047). In the multivariable Cox regression analyses, DAT (p = 0.028), acute coronary syndrome (p = 0.025), and anemia (p = 0.015) were independently associated with MACE. In addition, anemia (p = 0.022) was independently associated with, and DAT (p = 0.056) and thrombocytopenia (p = 0.051) tended to be associated with, major bleeding events. When analyzed among the prasugrel-DAT, clopidogrel-DAT, and TAT groups, there were no significant differences in clinical outcomes between the prasugrel-DAT and clopidogrel-DAT groups, and similar trends were observed for both 2 groups in comparison with the TAT group. CONCLUSIONS: In AF patients undergoing PCI, DAT was associated with lower incidence of MACE and major bleeding events compared with TAT. In comparison of P2Y12i, there might be no significant difference in the incidence of MACE and bleeding events between prasugrel-based DAT and clopidogrel-based DAT.


Asunto(s)
Fibrilación Atrial , Intervención Coronaria Percutánea , Humanos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Clorhidrato de Prasugrel , Clopidogrel/uso terapéutico , Fibrinolíticos/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/complicaciones , Intervención Coronaria Percutánea/efectos adversos , Estudios Retrospectivos , Estudios Prospectivos , Anticoagulantes/uso terapéutico , Hemorragia/inducido químicamente , Hemorragia/epidemiología
3.
Cardiovasc Interv Ther ; 38(4): 381-387, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37204672

RESUMEN

It is well known that patients with acute myocardial infarction (AMI) have delayed vessel healing despite accelerated endothelial progenitor cells (EPC) mobilization. The COMBO stent is a unique biodegradable-polymer sirolimus-eluting stent with an anti-CD34 antibody coating which captures EPC and potentially promotes vessel healing. However, there are limited data about strut tissue coverage at the very short-term period after COMBO stent implantation. This was a prospective study to investigate strut tissue coverage within 1 month after COMBO stent implantation using optical coherence tomography (OCT). Struts fully covered with tissue were defined as covered, and struts with distance from lumen surface longer than strut plus polymer thickness were defined as malapposed. Mean tissue thickness was measured only in apposed struts. A total of 8173 struts of 33 lesions in 32 patients were analyzed at an average of 19.8 ± 4.6 days after COMBO stent implantation. In lesion-level analysis, the rate of covered struts was 89.6 ± 7.2%, the rate of malapposed struts was 0.9 ± 2.0% and mean tissue thickness was 46.8 ± 14.3 µm. In comparison between AMI (n = 12) and non-AMI (n = 21) patients, there were no significant differences in the rate of covered struts (88.4 ± 8.4% vs. 90.2 ± 6.6%, p = 0.48) and mean tissue thickness (46.8 ± 13.7 µm vs. 46.9 ± 15.0 µm, p = 0.98). Multivariable analysis demonstrated that time from implantation to OCT imaging was significantly associated with mean tissue thickness. The COMBO stent had substantial tissue coverage at the very short-term period after implantation even in AMI patients, and follow-up time had an impact on vessel healing.


Asunto(s)
Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Sirolimus , Humanos , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Estudios Prospectivos , Diseño de Prótesis , Sirolimus/farmacología , Sirolimus/uso terapéutico , Tomografía de Coherencia Óptica/métodos , Resultado del Tratamiento
4.
Medicina (Kaunas) ; 58(10)2022 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-36295583

RESUMEN

Background and Objectives: Although previous studies showed that an activity of xanthine oxidoreductase (XOR), a rate-limiting enzyme in purine metabolism, beyond the serum uric acid level, was associated with the development of coronary artery disease (CAD), the underlying mechanisms are unclear. Because endothelial dysfunction and a greater blood pressure (BP) variability may play a role, we investigated the relations among the endothelial function, XOR, and BP variability. Materials and Methods: This was a post-hoc study using pooled data of patients with a stable CAD from two prospective investigations, in which the systemic endothelial function was assessed with the reactive hyperemia index (RHI) and the XOR activity was measured. The BP variability was evaluated using BP measurements during the three- and four-day hospitalization. Results: A total of 106 patients with a stable CAD undergoing a percutaneous coronary intervention were included. Of the 106 patients, 46 (43.4%) had a systemic endothelial dysfunction (RHI < 1.67). The multivariable analysis identified a higher body mass index (BMI), female gender, and diabetes as factors associated with an endothelial dysfunction. A higher BMI was also related to an elevated XOR activity, in addition to current smoking. No significant correlation was observed between the RHI and XOR activity. Similarly, the in-hospital BP variability was associated with neither the endothelial function nor XOR. Conclusions: Among patients with a stable CAD, several factors were identified as being associated with a systemic endothelial dysfunction or an elevated XOR activity. However, no direct relations between the endothelial function, XOR, and BP variability were found.


Asunto(s)
Enfermedad de la Arteria Coronaria , Xantina Deshidrogenasa , Humanos , Femenino , Xantina Deshidrogenasa/metabolismo , Presión Sanguínea , Ácido Úrico , Estudios Prospectivos , Biomarcadores
5.
J Cardiol ; 79(4): 559-563, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34895790

RESUMEN

BACKGROUND: It has been reported that Achilles tendon xanthoma (ATX), being one of the important diagnostic criteria for familial hypercholesterolemia, is independently associated with the severity of coronary artery disease (CAD). The aim of this study was to investigate plaque vulnerability in CAD patients with ATX. METHODS: Patients with CAD who underwent percutaneous coronary intervention (PCI) with near-infrared spectroscopy-intravascular ultrasound (NIRS-IVUS) guidance were enrolled. Soft X-ray radiography of the Achilles tendon was performed, and a maximum thickness of 9 mm or more was regarded as ATX. Using NIRS-IVUS, the degree of lipid core plaque (LCP) was evaluated by calculating the maximum value of lipid core burden index (LCBI) for any of the 4-mm segments (maxLCBI4mm) in the target lesion and non-target vessel. RESULTS: In a total of 156 patients, 14 patients (9.0%) had ATX. MaxLCBI4mm in the ATX group was significantly greater in the target lesion (p<0.001) and in the non-target vessel (p=0.032) compared to the non-ATX group. When patients were divided into tertiles according to Achilles tendon thickness, maxLCBI4mm was progressively increased in favor of thickness, although there was only a tendency in the target lesion (p=0.062), and no statistical significance in the non-target vessel (p=0.189). Multiple linear regression analysis determined ATX as an independent predictor for maxLCBI4mm in the target lesion and non-target vessel. CONCLUSIONS: ATX was associated with the degree of LCP in CAD patients requiring PCI. High-risk patients with lipid-rich vulnerable plaque can possibly be detected by evaluating Achilles tendon thickness.


Asunto(s)
Tendón Calcáneo , Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Placa Aterosclerótica , Xantomatosis , Tendón Calcáneo/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Humanos , Lípidos , Placa Aterosclerótica/complicaciones , Placa Aterosclerótica/diagnóstico por imagen , Valor Predictivo de las Pruebas , Ultrasonografía Intervencional , Xantomatosis/diagnóstico por imagen
6.
J Clin Med ; 10(19)2021 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-34640550

RESUMEN

Previous studies indicated that serum uric acid (SUA) level is a marker of endothelial function in subsets of ischemic heart disease (IHD). In the present study, we aimed to evaluate the relation between the SUA level and endothelial function in patients with a broad spectrum of IHD, including obstructive coronary artery disease (CAD) and ischemia with no obstructive CAD (INOCA). Three prospective studies and one retrospective study were pooled, in which the SUA level was measured, and systemic endothelial function was assessed using the reactive hyperemia index (RHI). The primary endpoint of the present study was a correlation of the SUA level with RHI. A total of 181 patients with a broad spectrum of IHD were included, among whom, 46 (25%) had acute coronary syndrome presentation and 15 (8%) had INOCA. Overall, the SUA level was negatively correlated with the RHI (r = -0.22, p = 0.003). Multivariable analysis identified the SUA level and INOCA as significant factors associated with RHI values. In conclusion, in patients with a broad spectrum of IHD, including obstructive epicardial CAD (chronic and acute coronary syndromes) and INOCA, the SUA level was significantly and negatively correlated with systemic endothelial function assessed with the RHI. INOCA, rather than obstructive CAD, was more associated with endothelial dysfunction.

7.
J Infect Chemother ; 24(5): 389-392, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29428565

RESUMEN

Severe fever with thrombocytopenia syndrome (SFTS) is a tick-borne infectious disease caused by the SFTS virus (SFTSV). Clinical symptoms of SFTS often involve encephalopathy and other central neurological symptoms, particularly in seriously ill patients; however, pathogenesis of encephalopathy by SFTSV is largely unknown. Herein, we present case reports of three patients with SFTS, complicated by encephalopathy, admitted to Tokushima University hospital: one patient was a 63-year-old man, while the other two were 83- and 86-year-old women. All of them developed disturbance of consciousness around the 7th day post onset of fever. After methylprednisolone pulse therapy of 500 mg/day, all of them recovered without any neurological sequelae. SFTSV genome was not detected in the cerebrospinal fluid of 2 out of the 3 patients that were available for examination. In these patients, disturbance of consciousness seemed to be an indirect effect of the cytokine storm triggered by SFTSV infection. We propose that short-term glucocorticoid therapy might be beneficial in the treatment of encephalopathy during early phase of SFTSV infection.


Asunto(s)
Antiinflamatorios/administración & dosificación , Encefalopatías/tratamiento farmacológico , Infecciones por Bunyaviridae/tratamiento farmacológico , Fiebre/tratamiento farmacológico , Metilprednisolona/administración & dosificación , Phlebovirus/aislamiento & purificación , Trombocitopenia/tratamiento farmacológico , Enfermedades por Picaduras de Garrapatas/tratamiento farmacológico , Anciano de 80 o más Años , Antiinflamatorios/uso terapéutico , Encefalopatías/líquido cefalorraquídeo , Encefalopatías/etiología , Encefalopatías/virología , Infecciones por Bunyaviridae/líquido cefalorraquídeo , Infecciones por Bunyaviridae/complicaciones , Infecciones por Bunyaviridae/virología , Femenino , Fiebre/líquido cefalorraquídeo , Fiebre/etiología , Fiebre/virología , Hospitales Universitarios , Humanos , Masculino , Metilprednisolona/uso terapéutico , Persona de Mediana Edad , Phlebovirus/efectos de los fármacos , Phlebovirus/genética , Quimioterapia por Pulso , Síndrome , Trombocitopenia/líquido cefalorraquídeo , Trombocitopenia/virología , Enfermedades por Picaduras de Garrapatas/líquido cefalorraquídeo , Enfermedades por Picaduras de Garrapatas/virología
8.
Langmuir ; 25(19): 11969-74, 2009 Oct 06.
Artículo en Inglés | MEDLINE | ID: mdl-19731941

RESUMEN

We have investigated a photosensor that consists of a field emission transistor (FET) utilizing the biocomponent of the photosystem I (PSI) protein complex for use in an imaging device. The PSI was immobilized on a gold electrode via the self-assembling monolayer (SAM) of 3-mercapto-1-propanesulfonic acid sodium salt to obtain a PSI-modified gold electrode. As for the PSI-modified gold electrode, the basic photoresponses originating from the excitation of PSI, including the photocurrent (106 nA) and the photoresponse of the open-circuit voltage (photo-Voc: 28.6 mV), were characterized. Then, the PSI-modified gold electrode was linked to the gate of the FET using a lead line, and the device was successfully driven by the photoelectric signals from the PSI like a voltage follower circuit. Further, we successfully demonstrated that the PSI-based FET acts as a photosensor in imaging devices.


Asunto(s)
Luz , Complejo de Proteína del Fotosistema I/metabolismo , Cianobacterias/enzimología , Conductividad Eléctrica , Electrodos , Oro/química , Procesos Fotoquímicos , Complejo de Proteína del Fotosistema I/química , Transistores Electrónicos
9.
Angew Chem Int Ed Engl ; 48(9): 1585-7, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19156784

RESUMEN

Plug and play: Photoinduced electron transfer occurs from photoexcited P700 in photosystem I (PSI) to a gold surface (see picture). A novel molecular connector system is used, in which an artificial molecular wire, which is assembled on the gold surface, was plugged into PSI by reconstitution. Analysis of the photoelectron transfer kinetics proved both the output of electrons from PSI and the effectiveness of the molecular wire.


Asunto(s)
Electrodos , Oro/química , Complejo de Proteína del Fotosistema I/química , Transporte de Electrón , Cinética , Nanopartículas del Metal/química , Complejo de Proteína del Fotosistema I/metabolismo , Vitamina K 1/química
10.
Appl Spectrosc ; 61(1): 6-10, 2007 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-17311707

RESUMEN

The contrast transfer function (CTF) of super-resolution microscopy was quantitatively investigated using a fluorescent scale. The scale has minute fluorescent line patterns, finer than 100 nm, and is suitable for measuring CTF in super-resolution microscopy. The measured CTF shows that super-resolution microscopy can indeed improve the optical properties of fluorescent images and enable us to observe a structure with the spatial resolution overcoming the diffraction limit. From the CTF, it has been found that super-resolution microcopy can resolve a 100 nm line-and-space pattern and provides a contrast of 10%. The CTF corresponds to a PSF with a full-width at half-maximum (FWHM) of 130 nm. An evaluation using a 100 nmphi fluorescent bead consistently supports the results given by the CTF for super-resolution microscopy.


Asunto(s)
Aumento de la Imagen/instrumentación , Aumento de la Imagen/métodos , Microscopía de Fluorescencia por Excitación Multifotónica/instrumentación , Microscopía de Fluorescencia por Excitación Multifotónica/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
11.
Biochim Biophys Acta ; 1767(6): 653-9, 2007 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-17184727

RESUMEN

We report on the first successful output of electrons directly from photosystem I (PSI) of thermophilic cyanobacteria to the gate of a field-effect transistor (FET) by bypassing electron flow via a newly designed molecular wire, i.e., artificial vitamin K(1), and a gold nanoparticle; in short, this newly manufactured photosensor employs a bio-functional unit as the core of the device. Photo-electrons generated by the irradiation of molecular complexes composed of reconstituted PSI on the gate were found to control the FET. This PSI-bio-photosensor can be used to interpret gradation in images. This PSI-FET system is moreover sufficiently stable for use exceeding a period of 1 year.


Asunto(s)
Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Cianobacterias/química , Complejo de Proteína del Fotosistema I/química , Complejo de Proteína del Fotosistema I/metabolismo , Electroquímica , Oro/química , Modelos Químicos , Estructura Molecular , Nanopartículas/química , Complejo de Proteína del Fotosistema I/ultraestructura , Tensoactivos/química , Tiourea/química , Transistores Electrónicos , Vitamina K 1/química
12.
Magn Reson Imaging ; 23(4): 607-10, 2005 May.
Artículo en Inglés | MEDLINE | ID: mdl-15919608

RESUMEN

In order to establish a continuous hyperpolarized xenon-129 (HP-129Xe) gas delivery system for MR imaging, the effect of the metallic materials in the gas pipeline on the signal intensity was investigated. In the gas pipeline, an appropriate surface is needed to minimize wall relaxation by the HP-129Xe gas caused by the interaction between the HP gas and the surface, which can lead to signal loss. Although Pyrex glass is a popular material for the HP gas chamber, it is fragile under heat or physical stress. In this study, five stainless steel tubes (STs) prepared with different surface film-forming processes were examined. The MR signal intensities of HP-129Xe gas that passed through each tube were then compared. The film passivated by iron fluoride maintained the highest level of hyperpolarization, whereas that passivated by chromium oxide maintained the lowest. A ST with an appropriate passive film may be a useful alternative to a Pyrex glass pipeline.


Asunto(s)
Espectroscopía de Resonancia Magnética/métodos , Gases Nobles , Isótopos de Xenón , Diseño de Equipo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA