Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Radiol Artif Intell ; 6(1): e220231, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38197800

RESUMEN

Purpose To present results from a literature survey on practices in deep learning segmentation algorithm evaluation and perform a study on expert quality perception of brain tumor segmentation. Materials and Methods A total of 180 articles reporting on brain tumor segmentation algorithms were surveyed for the reported quality evaluation. Additionally, ratings of segmentation quality on a four-point scale were collected from medical professionals for 60 brain tumor segmentation cases. Results Of the surveyed articles, Dice score, sensitivity, and Hausdorff distance were the most popular metrics to report segmentation performance. Notably, only 2.8% of the articles included clinical experts' evaluation of segmentation quality. The experimental results revealed a low interrater agreement (Krippendorff α, 0.34) in experts' segmentation quality perception. Furthermore, the correlations between the ratings and commonly used quantitative quality metrics were low (Kendall tau between Dice score and mean rating, 0.23; Kendall tau between Hausdorff distance and mean rating, 0.51), with large variability among the experts. Conclusion The results demonstrate that quality ratings are prone to variability due to the ambiguity of tumor boundaries and individual perceptual differences, and existing metrics do not capture the clinical perception of segmentation quality. Keywords: Brain Tumor Segmentation, Deep Learning Algorithms, Glioblastoma, Cancer, Machine Learning Clinical trial registration nos. NCT00756106 and NCT00662506 Supplemental material is available for this article. © RSNA, 2023.


Asunto(s)
Neoplasias Encefálicas , Aprendizaje Profundo , Glioblastoma , Humanos , Algoritmos , Benchmarking , Neoplasias Encefálicas/diagnóstico por imagen , Glioblastoma/diagnóstico por imagen
2.
Acad Radiol ; 31(4): 1572-1582, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37951777

RESUMEN

RATIONALE AND OBJECTIVES: Brain tumor segmentations are integral to the clinical management of patients with glioblastoma, the deadliest primary brain tumor in adults. The manual delineation of tumors is time-consuming and highly provider-dependent. These two problems must be addressed by introducing automated, deep-learning-based segmentation tools. This study aimed to identify criteria experts use to evaluate the quality of automatically generated segmentations and their thought processes as they correct them. MATERIALS AND METHODS: Multiple methods were used to develop a detailed understanding of the complex factors that shape experts' perception of segmentation quality and their thought processes in correcting proposed segmentations. Data from a questionnaire and semistructured interview with neuro-oncologists and neuroradiologists were collected between August and December 2021 and analyzed using a combined deductive and inductive approach. RESULTS: Brain tumors are highly complex and ambiguous segmentation targets. Therefore, physicians rely heavily on the given context related to the patient and clinical context in evaluating the quality and need to correct brain tumor segmentation. Most importantly, the intended clinical application determines the segmentation quality criteria and editing decisions. Physicians' personal beliefs and preferences about the capabilities of AI algorithms and whether questionable areas should not be included are additional criteria influencing the perception of segmentation quality and appearance of an edited segmentation. CONCLUSION: Our findings on experts' perceptions of segmentation quality will allow the design of improved frameworks for expert-centered evaluation of brain tumor segmentation models. In particular, the knowledge presented here can inspire the development of brain tumor-specific metrics for segmentation model training and evaluation.


Asunto(s)
Neoplasias Encefálicas , Glioblastoma , Adulto , Humanos , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/patología , Algoritmos , Glioblastoma/patología , Reconocimiento de Normas Patrones Automatizadas/métodos , Carga Tumoral , Imagen por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos
3.
Neuro Oncol ; 2023 Dec 09.
Artículo en Inglés | MEDLINE | ID: mdl-38070147

RESUMEN

BACKGROUND: We recently conducted a phase 2 trial (NCT028865685) evaluating intracranial efficacy of pembrolizumab for brain metastases (BM) of diverse histologies. Our study met its primary efficacy endpoint and illustrates that pembrolizumab exerts promising activity in a select group of patients with BM. Given the importance of aberrant vasculature in mediating immunosuppression, we explored the relationship between checkpoint inhibitor (ICI) efficacy and vascular architecture in the hopes of identifying potential mechanisms of intracranial ICI response or resistance for BM. METHODS: Using Vessel Architectural Imaging (VAI), a histologically validated quantitative metric for in vivo tumor vascular physiology, we analyzed dual echo DSC/DCE MRI for 44 patients on trial. Tumor and peri-tumor cerebral blood volume/flow, vessel size, arterial- and venous-dominance, and vascular permeability were measured before and after treatment with pembrolizumab. RESULTS: BM that progressed on ICI were characterized by a highly aberrant vasculature dominated by large-caliber vessels. In contrast, ICI-responsive BM possessed a more structurally balanced vasculature consisting of both small and large vessels, and there was a trend towards a decrease in under-perfused tissue, suggesting a reversal of the negative effects of hypoxia. In the peri-tumor region, development of smaller blood vessels, consistent with neo-angiogenesis, was associated with tumor growth before radiographic evidence of contrast enhancement on anatomical MRI. CONCLUSIONS: This study, one of the largest functional imaging studies for BM, suggests that vascular architecture is linked with ICI efficacy. Studies identifying modulators of vascular architecture, and effects on immune activity, are warranted and may inform future combination treatments.

4.
bioRxiv ; 2023 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-37693537

RESUMEN

Structurally and functionally aberrant vasculature is a hallmark of tumor angiogenesis and treatment resistance. Given the synergistic link between aberrant tumor vasculature and immunosuppression, we analyzed perfusion MRI for 44 patients with brain metastases (BM) undergoing treatment with pembrolizumab. To date, vascular-immune communication, or the relationship between immune checkpoint inhibitor (ICI) efficacy and vascular architecture, has not been well-characterized in human imaging studies. We found that ICI-responsive BM possessed a structurally balanced vascular makeup, which was linked to improved vascular efficiency and an immune-stimulatory microenvironment. In contrast, ICI-resistant BM were characterized by a lack of immune cell infiltration and a highly aberrant vasculature dominated by large-caliber vessels. Peri-tumor region analysis revealed early functional changes predictive of ICI resistance before radiographic evidence on conventional MRI. This study was one of the largest functional imaging studies for BM and establishes a foundation for functional studies that illuminate the mechanisms linking patterns of vascular architecture with immunosuppression, as targeting these aspects of cancer biology may serve as the basis for future combination treatments.

5.
IEEE Trans Med Imaging ; 42(8): 2439-2450, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37028063

RESUMEN

Near-infrared diffuse optical tomography (DOT) is a promising functional modality for breast cancer imaging; however, the clinical translation of DOT is hampered by technical limitations. Specifically, conventional finite element method (FEM)-based optical image reconstruction approaches are time-consuming and ineffective in recovering full lesion contrast. To address this, we developed a deep learning-based reconstruction model (FDU-Net) comprised of a Fully connected subnet, followed by a convolutional encoder-Decoder subnet, and a U-Net for fast, end-to-end 3D DOT image reconstruction. The FDU-Net was trained on digital phantoms that include randomly located singular spherical inclusions of various sizes and contrasts. Reconstruction performance was evaluated in 400 simulated cases with realistic noise profiles for the FDU-Net and conventional FEM approaches. Our results show that the overall quality of images reconstructed by FDU-Net is significantly improved compared to FEM-based methods and a previously proposed deep-learning network. Importantly, once trained, FDU-Net demonstrates substantially better capability to recover true inclusion contrast and location without using any inclusion information during reconstruction. The model was also generalizable to multi-focal and irregularly shaped inclusions unseen during training. Finally, FDU-Net, trained on simulated data, could successfully reconstruct a breast tumor from a real patient measurement. Overall, our deep learning-based approach demonstrates marked superiority over the conventional DOT image reconstruction methods while also offering over four orders of magnitude acceleration in computational time. Once adapted to the clinical breast imaging workflow, FDU-Net has the potential to provide real-time accurate lesion characterization by DOT to assist the clinical diagnosis and management of breast cancer.


Asunto(s)
Neoplasias de la Mama , Aprendizaje Profundo , Humanos , Femenino , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional , Fantasmas de Imagen , Neoplasias de la Mama/diagnóstico por imagen , Algoritmos
6.
Radiology ; 307(1): e220715, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36537895

RESUMEN

Background Radiomics is the extraction of predefined mathematic features from medical images for the prediction of variables of clinical interest. While some studies report superlative accuracy of radiomic machine learning (ML) models, the published methodology is often incomplete, and the results are rarely validated in external testing data sets. Purpose To characterize the type, prevalence, and statistical impact of methodologic errors present in radiomic ML studies. Materials and Methods Radiomic ML publications were reviewed for the presence of performance-inflating methodologic flaws. Common flaws were subsequently reproduced with randomly generated features interpolated from publicly available radiomic data sets to demonstrate the precarious nature of reported findings. Results In an assessment of radiomic ML publications, the authors uncovered two general categories of data analysis errors: inconsistent partitioning and unproductive feature associations. In simulations, the authors demonstrated that inconsistent partitioning augments radiomic ML accuracy by 1.4 times from unbiased performance and that correcting for flawed methodologic results in areas under the receiver operating characteristic curve approaching a value of 0.5 (random chance). With use of randomly generated features, the authors illustrated that unproductive associations between radiomic features and gene sets can imply false causality for biologic phenomenon. Conclusion Radiomic machine learning studies may contain methodologic flaws that undermine their validity. This study provides a review template to avoid such flaws. © RSNA, 2022 Supplemental material is available for this article. See also the editorial by Jacobs in this issue.


Asunto(s)
Aprendizaje Automático , Humanos , Curva ROC , Estudios Retrospectivos
7.
NPJ Digit Med ; 5(1): 174, 2022 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-36400939

RESUMEN

The integration of artificial intelligence into clinical workflows requires reliable and robust models. Repeatability is a key attribute of model robustness. Ideal repeatable models output predictions without variation during independent tests carried out under similar conditions. However, slight variations, though not ideal, may be unavoidable and acceptable in practice. During model development and evaluation, much attention is given to classification performance while model repeatability is rarely assessed, leading to the development of models that are unusable in clinical practice. In this work, we evaluate the repeatability of four model types (binary classification, multi-class classification, ordinal classification, and regression) on images that were acquired from the same patient during the same visit. We study the each model's performance on four medical image classification tasks from public and private datasets: knee osteoarthritis, cervical cancer screening, breast density estimation, and retinopathy of prematurity. Repeatability is measured and compared on ResNet and DenseNet architectures. Moreover, we assess the impact of sampling Monte Carlo dropout predictions at test time on classification performance and repeatability. Leveraging Monte Carlo predictions significantly increases repeatability, in particular at the class boundaries, for all tasks on the binary, multi-class, and ordinal models leading to an average reduction of the 95% limits of agreement by 16% points and of the class disagreement rate by 7% points. The classification accuracy improves in most settings along with the repeatability. Our results suggest that beyond about 20 Monte Carlo iterations, there is no further gain in repeatability. In addition to the higher test-retest agreement, Monte Carlo predictions are better calibrated which leads to output probabilities reflecting more accurately the true likelihood of being correctly classified.

8.
Artículo en Inglés | MEDLINE | ID: mdl-36998700

RESUMEN

Deep learning (DL) models have provided state-of-the-art performance in various medical imaging benchmarking challenges, including the Brain Tumor Segmentation (BraTS) challenges. However, the task of focal pathology multi-compartment segmentation (e.g., tumor and lesion sub-regions) is particularly challenging, and potential errors hinder translating DL models into clinical workflows. Quantifying the reliability of DL model predictions in the form of uncertainties could enable clinical review of the most uncertain regions, thereby building trust and paving the way toward clinical translation. Several uncertainty estimation methods have recently been introduced for DL medical image segmentation tasks. Developing scores to evaluate and compare the performance of uncertainty measures will assist the end-user in making more informed decisions. In this study, we explore and evaluate a score developed during the BraTS 2019 and BraTS 2020 task on uncertainty quantification (QU-BraTS) and designed to assess and rank uncertainty estimates for brain tumor multi-compartment segmentation. This score (1) rewards uncertainty estimates that produce high confidence in correct assertions and those that assign low confidence levels at incorrect assertions, and (2) penalizes uncertainty measures that lead to a higher percentage of under-confident correct assertions. We further benchmark the segmentation uncertainties generated by 14 independent participating teams of QU-BraTS 2020, all of which also participated in the main BraTS segmentation task. Overall, our findings confirm the importance and complementary value that uncertainty estimates provide to segmentation algorithms, highlighting the need for uncertainty quantification in medical image analyses. Finally, in favor of transparency and reproducibility, our evaluation code is made publicly available at https://github.com/RagMeh11/QU-BraTS.

9.
Radiol Artif Intell ; 3(6): e200267, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34870212

RESUMEN

PURPOSE: To evaluate the trustworthiness of saliency maps for abnormality localization in medical imaging. MATERIALS AND METHODS: Using two large publicly available radiology datasets (Society for Imaging Informatics in Medicine-American College of Radiology Pneumothorax Segmentation dataset and Radiological Society of North America Pneumonia Detection Challenge dataset), the performance of eight commonly used saliency map techniques were quantified in regard to (a) localization utility (segmentation and detection), (b) sensitivity to model weight randomization, (c) repeatability, and (d) reproducibility. Their performances versus baseline methods and localization network architectures were compared, using area under the precision-recall curve (AUPRC) and structural similarity index measure (SSIM) as metrics. RESULTS: All eight saliency map techniques failed at least one of the criteria and were inferior in performance compared with localization networks. For pneumothorax segmentation, the AUPRC ranged from 0.024 to 0.224, while a U-Net achieved a significantly superior AUPRC of 0.404 (P < .005). For pneumonia detection, the AUPRC ranged from 0.160 to 0.519, while a RetinaNet achieved a significantly superior AUPRC of 0.596 (P <.005). Five and two saliency methods (of eight) failed the model randomization test on the segmentation and detection datasets, respectively, suggesting that these methods are not sensitive to changes in model parameters. The repeatability and reproducibility of the majority of the saliency methods were worse than localization networks for both the segmentation and detection datasets. CONCLUSION: The use of saliency maps in the high-risk domain of medical imaging warrants additional scrutiny and recommend that detection or segmentation models be used if localization is the desired output of the network.Keywords: Technology Assessment, Technical Aspects, Feature Detection, Convolutional Neural Network (CNN) Supplemental material is available for this article. © RSNA, 2021.

10.
Radiol Artif Intell ; 3(1): e190199, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33842889

RESUMEN

PURPOSE: To determine the influence of preprocessing on the repeatability and redundancy of radiomics features extracted using a popular open-source radiomics software package in a scan-rescan glioblastoma MRI study. MATERIALS AND METHODS: In this study, a secondary analysis of T2-weighted fluid-attenuated inversion recovery (FLAIR) and T1-weighted postcontrast images from 48 patients (mean age, 56 years [range, 22-77 years]) diagnosed with glioblastoma were included from two prospective studies (ClinicalTrials.gov NCT00662506 [2009-2011] and NCT00756106 [2008-2011]). All patients underwent two baseline scans 2-6 days apart using identical imaging protocols on 3-T MRI systems. No treatment occurred between scan and rescan, and tumors were essentially unchanged visually. Radiomic features were extracted by using PyRadiomics (https://pyradiomics.readthedocs.io/) under varying conditions, including normalization strategies and intensity quantization. Subsequently, intraclass correlation coefficients were determined between feature values of the scan and rescan. RESULTS: Shape features showed a higher repeatability than intensity (adjusted P < .001) and texture features (adjusted P < .001) for both T2-weighted FLAIR and T1-weighted postcontrast images. Normalization improved the overlap between the region of interest intensity histograms of scan and rescan (adjusted P < .001 for both T2-weighted FLAIR and T1-weighted postcontrast images), except in scans where brain extraction fails. As such, normalization significantly improves the repeatability of intensity features from T2-weighted FLAIR scans (adjusted P = .003 [z score normalization] and adjusted P = .002 [histogram matching]). The use of a relative intensity binning strategy as opposed to default absolute intensity binning reduces correlation between gray-level co-occurrence matrix features after normalization. CONCLUSION: Both normalization and intensity quantization have an effect on the level of repeatability and redundancy of features, emphasizing the importance of both accurate reporting of methodology in radiomics articles and understanding the limitations of choices made in pipeline design. Supplemental material is available for this article. © RSNA, 2020See also the commentary by Tiwari and Verma in this issue.

11.
Neuroinformatics ; 19(1): 127-140, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32578020

RESUMEN

Translating deep learning research from theory into clinical practice has unique challenges, specifically in the field of neuroimaging. In this paper, we present DeepNeuro, a Python-based deep learning framework that puts deep neural networks for neuroimaging into practical usage with a minimum of friction during implementation. We show how this framework can be used to design deep learning pipelines that can load and preprocess data, design and train various neural network architectures, and evaluate and visualize the results of trained networks on evaluation data. We present a way of reproducibly packaging data pre- and postprocessing functions common in the neuroimaging community, which facilitates consistent performance of networks across variable users, institutions, and scanners. We show how deep learning pipelines created with DeepNeuro can be concisely packaged into shareable Docker and Singularity containers with user-friendly command-line interfaces.


Asunto(s)
Aprendizaje Profundo , Procesamiento de Imagen Asistido por Computador/métodos , Neuroimagen/métodos , Humanos
12.
J Am Coll Radiol ; 17(12): 1653-1662, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32592660

RESUMEN

OBJECTIVE: We developed deep learning algorithms to automatically assess BI-RADS breast density. METHODS: Using a large multi-institution patient cohort of 108,230 digital screening mammograms from the Digital Mammographic Imaging Screening Trial, we investigated the effect of data, model, and training parameters on overall model performance and provided crowdsourcing evaluation from the attendees of the ACR 2019 Annual Meeting. RESULTS: Our best-performing algorithm achieved good agreement with radiologists who were qualified interpreters of mammograms, with a four-class κ of 0.667. When training was performed with randomly sampled images from the data set versus sampling equal number of images from each density category, the model predictions were biased away from the low-prevalence categories such as extremely dense breasts. The net result was an increase in sensitivity and a decrease in specificity for predicting dense breasts for equal class compared with random sampling. We also found that the performance of the model degrades when we evaluate on digital mammography data formats that differ from the one that we trained on, emphasizing the importance of multi-institutional training sets. Lastly, we showed that crowdsourced annotations, including those from attendees who routinely read mammograms, had higher agreement with our algorithm than with the original interpreting radiologists. CONCLUSION: We demonstrated the possible parameters that can influence the performance of the model and how crowdsourcing can be used for evaluation. This study was performed in tandem with the development of the ACR AI-LAB, a platform for democratizing artificial intelligence.


Asunto(s)
Neoplasias de la Mama , Colaboración de las Masas , Aprendizaje Profundo , Inteligencia Artificial , Densidad de la Mama , Neoplasias de la Mama/diagnóstico por imagen , Femenino , Humanos , Mamografía
13.
NPJ Digit Med ; 3: 48, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32258430

RESUMEN

Using medical images to evaluate disease severity and change over time is a routine and important task in clinical decision making. Grading systems are often used, but are unreliable as domain experts disagree on disease severity category thresholds. These discrete categories also do not reflect the underlying continuous spectrum of disease severity. To address these issues, we developed a convolutional Siamese neural network approach to evaluate disease severity at single time points and change between longitudinal patient visits on a continuous spectrum. We demonstrate this in two medical imaging domains: retinopathy of prematurity (ROP) in retinal photographs and osteoarthritis in knee radiographs. Our patient cohorts consist of 4861 images from 870 patients in the Imaging and Informatics in Retinopathy of Prematurity (i-ROP) cohort study and 10,012 images from 3021 patients in the Multicenter Osteoarthritis Study (MOST), both of which feature longitudinal imaging data. Multiple expert clinician raters ranked 100 retinal images and 100 knee radiographs from excluded test sets for severity of ROP and osteoarthritis, respectively. The Siamese neural network output for each image in comparison to a pool of normal reference images correlates with disease severity rank (ρ = 0.87 for ROP and ρ = 0.89 for osteoarthritis), both within and between the clinical grading categories. Thus, this output can represent the continuous spectrum of disease severity at any single time point. The difference in these outputs can be used to show change over time. Alternatively, paired images from the same patient at two time points can be directly compared using the Siamese neural network, resulting in an additional continuous measure of change between images. Importantly, our approach does not require manual localization of the pathology of interest and requires only a binary label for training (same versus different). The location of disease and site of change detected by the algorithm can be visualized using an occlusion sensitivity map-based approach. For a longitudinal binary change detection task, our Siamese neural networks achieve test set receiving operator characteristic area under the curves (AUCs) of up to 0.90 in evaluating ROP or knee osteoarthritis change, depending on the change detection strategy. The overall performance on this binary task is similar compared to a conventional convolutional deep-neural network trained for multi-class classification. Our results demonstrate that convolutional Siamese neural networks can be a powerful tool for evaluating the continuous spectrum of disease severity and change in medical imaging.

14.
World Neurosurg ; 131: e46-e51, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31295616

RESUMEN

BACKGROUND: Machine learning (ML) has been increasingly used in medicine and neurosurgery. We sought to determine whether ML models can distinguish ruptured from unruptured aneurysms and identify features associated with rupture. METHODS: We performed a retrospective review of patients with intracranial aneurysms detected on vascular imaging at our institution between 2002 and 2018. The dataset was used to train 3 ML models (random forest, linear support vector machine [SVM], and radial basis function kernel SVM). Relative contributions of individual predictors were derived from the linear SVM model. RESULTS: Complete data were available for 845 aneurysms in 615 patients. Ruptured aneurysms (n = 309, 37%) were larger (mean 6.51 mm vs. 5.73 mm; P = 0.02) and more likely to be in the posterior circulation (20% vs. 11%; P < 0.001) than unruptured aneurysms. Area under the receiver operating curve was 0.77 for the linear SVM, 0.78 for the radial basis function kernel SVM models, and 0.81 for the random forest model. Aneurysm location and size were the 2 features that contributed most significantly to the model. Posterior communicating artery, anterior communicating artery, and posterior inferior cerebellar artery locations were most highly associated with rupture, whereas paraclinoid and middle cerebral artery locations had the strongest association with unruptured status. CONCLUSIONS: ML models are capable of accurately distinguishing ruptured from unruptured aneurysms and identifying features associated with rupture. Consistent with prior studies, location and size show the strongest association with aneurysm rupture.


Asunto(s)
Aneurisma Roto/diagnóstico , Aneurisma Intracraneal/diagnóstico , Aprendizaje Automático , Adulto , Anciano , Aneurisma Roto/diagnóstico por imagen , Aneurisma Roto/epidemiología , Estudios de Casos y Controles , Comorbilidad , Diabetes Mellitus/epidemiología , Femenino , Humanos , Hiperlipidemias/epidemiología , Hipertensión/epidemiología , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/epidemiología , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad y Especificidad , Fumar/epidemiología , Máquina de Vectores de Soporte
15.
Biomed Opt Express ; 10(4): 2067-2089, 2019 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-31086717

RESUMEN

We present a microscopic image guidance platform for radiofrequency ablation (RFA) using a clinical balloon-catheter-based optical coherence tomography (OCT) system, currently used in the surveillance of Barrett's esophagus patients. Our integrated thermal therapy delivery and monitoring platform consists of a flexible, customized bipolar RFA electrode array designed for use with a clinical balloon OCT catheter and a processing algorithm to accurately map the thermal coagulation process. Non-uniform rotation distortion was corrected using a feature tracking-based technique, which enables robust, frame-to-frame analysis of the temporal fluctuation of the complex OCT signal. With proper noise calibration, precise delineation of the thermal therapy zone was demonstrated using cumulative complex differential variance in porcine esophagus ex vivo with the integrated OCT-RFA system, as validated by nitroblue tetrazolium chloride (NBTC) histology. The ability to directly and accurately visualize the thermal coagulation process at high resolution is critical to the precise delivery of thermal energy to a wide range of epithelial lesions.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA