Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
Circulation ; 139(23): 2628-2638, 2019 06 04.
Artículo en Inglés | MEDLINE | ID: mdl-30882234

RESUMEN

BACKGROUND: Patients with end-stage renal disease who are undergoing dialysis are reported to be at high risk of sudden cardiac death (SCD), and to date, no therapy has been shown to be effective in reducing this risk. The feasibility and value of prophylactic implantable cardioverter-defibrillator (ICD) implantation to prevent SCD is uncertain. METHODS: We conducted the ICD2 trial (Implantable Cardioverter-Defibrillator in Dialysis Patients), a prospective, randomized, controlled study investigating the value and safety of ICD implantation to prevent SCD in 200 patients on dialysis with a left ventricular ejection fraction ≥35%, after adequate screening and optimization of other treatments. The primary end point was SCD. Secondary end points were all-cause mortality and ICD-related complications. RESULTS: The trial was stopped as per the recommendation of the data and safety monitoring board for futility reasons after inclusion of 188 patients, 97 in the ICD group and 91 in the control group. The median duration of follow-up was 6.8 years (interquartile range, 3.8-8.8 years). SCD occurred in 19 of 188 cases (10.1%), 11 of 97 in the ICD group and 8 of 91 in the control group. The cumulative SCD incidence at 5 years was 9.7% (95% CI, 3.3%-16.2%) in the ICD group and 7.9% (95% CI, 1.7-14.0%) in the control group, resulting in a hazard ratio of 1.32 (95% CI, 0.53-3.29; P=0.55). Overall, 99 of 188 patients died (52.7%), 52 in the ICD group and 47 in the control group. Five-year survival probability was 50.6% (95% CI, 39.8%-61.5%) in the ICD group and 54.5% (95% CI, 43.0-66.0%) in the control group, resulting in a hazard ratio of 1.02 (95% CI, 0.69-1.52; P=0.92). Among 80 patients who received an ICD, 25 adverse events related to ICD implantation occurred. CONCLUSIONS: In a well-screened and well-treated population undergoing dialysis, prophylactic ICD therapy did not reduce the rate of SCD or all-cause mortality, which remained high. CLINICAL TRIAL REGISTRATION: URL: http://www.controlled-trials.com . Unique identifier: ISRCTN20479861.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Insuficiencia Cardíaca/terapia , Fallo Renal Crónico/terapia , Diálisis Renal , Anciano , Anciano de 80 o más Años , Terminación Anticipada de los Ensayos Clínicos , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Humanos , Fallo Renal Crónico/diagnóstico , Fallo Renal Crónico/mortalidad , Masculino , Inutilidad Médica , Persona de Mediana Edad , Países Bajos , Estudios Prospectivos , Factores Protectores , Diálisis Renal/efectos adversos , Diálisis Renal/mortalidad , Factores de Riesgo , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA