Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
J Cardiovasc Electrophysiol ; 35(5): 1050-1054, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38501328

RESUMEN

INTRODUCTION: Tricuspid regurgitation is associated with significant morbidity and mortality, and occurs at a higher rate in patients with cardiovascular implantable electronic devices. Percutaneous strategies for managing tricuspid regurgitation are evolving, including the development of bicaval valve implantation which has been successfully used in patients with pacing leads. METHODS AND RESULTS: We present the first documented case of lead failure following TricValve® implantation, a dedicated self-expanding system for bicaval valve implantation, and the first successful lead revision procedure in this setting. CONCLUSION: The case illustrates important considerations in undertaking percutaneous intervention in patients with cardiovascular implantable electronic devices, and their ongoing management.


Asunto(s)
Desfibriladores Implantables , Falla de Equipo , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Masculino , Anciano , Resultado del Tratamiento , Reoperación , Diseño de Prótesis , Remoción de Dispositivos , Femenino , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/efectos adversos
2.
J Cardiovasc Dev Dis ; 8(12)2021 Dec 13.
Artículo en Inglés | MEDLINE | ID: mdl-34940538

RESUMEN

Laser balloon (LB) has emerged as an interesting strategy for pulmonary vein isolation in paroxysmal atrial fibrillation (AF). A third-generation LB has recently been developed, allowing a continuous ablation set. We aimed to compare the results from our center's experience with second and third-generation LBs to a cohort of matched patients who had undergone radiofrequency ablation (RFA) with contact-force catheters. This retrospective monocenter case-control study included our first 50 LB paroxysmal AF ablations (26 second and 24 third-generation LB) and 50 RFA controls, matched on age, sex and left atrial dilation. The two groups had similar baseline parameters. LB procedures were significantly shorter than RFA (129 (110-160) vs. 160 (119-198) min, p = 0.007). During AF ablation, two major complications occurred in each group. At the one-year follow-up, AF recurrence was diagnosed in 7 (14%) of the LB group vs. 14 (28%) of the RFA group (p = 0.14). Moreover, we observed that third-generation LB procedures were associated with shorter laser applications (22 (19-29) vs. 69 (55-76) min, p < 0.001) and procedural durations (111 (100-128) vs. 151.5 (128.5-167) min, p < 0.001) compared to second-generation LB procedures. In the context of the major increase in the number of AF ablations, LB demonstrated consistent results in terms of clinical success, complications and also reduced procedure durations compared to RFA.

3.
J Clin Med ; 10(18)2021 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-34575348

RESUMEN

BACKGROUND: Activated Clotting Time (ACT) guided heparinization is the gold standard for titrating unfractionated heparin (UFH) administration during atrial fibrillation (AF) ablation procedures. The current ACT target (300 s) is based on studies in patients receiving a vitamin K antagonist (VKA). Several studies have shown that in patients receiving Direct Oral Anticoagulants (DOACs), the correlation between ACT values and UFH delivered dose is weak. OBJECTIVE: To assess the relationship between ACT and real heparin anticoagulant effect measured by anti-Xa activity in patients receiving different anticoagulant treatments. METHODS: Patients referred for AF catheter ablation in our centre were prospectively included depending on their anticoagulant type. RESULTS: 113 patients were included, receiving rivaroxaban (n = 30), apixaban (n = 30), dabigatran (n = 30), and VKA (n = 23). To meet target ACT, a higher UFH dose was required in DOAC than VKA patients (14,077.8 IU vs. 9565.2 IU, p < 0.001), leading to a longer time to achieve target ACT (46.5 min vs. 27.3 min, p = 0.001). The correlation of ACT and anti-Xa activity was tighter in the VKA group (Spearman correlation ρ = 0.53), compared to the DOAC group (ρ = 0.19). Despite lower ACT values in the DOAC group, this group demonstrated a higher mean anti-Xa activity compared to the VKA group (1.56 ± 0.39 vs. 1.14 ± 0.36; p = 0.002). CONCLUSION: Use of a conventional ACT threshold at 300 s during AF ablation procedures leads to a significant increase in UFH administration in patients treated with DOACs. This increase corresponds more likely to an overdosing than a real increase in UFH requirement.

5.
Heart Rhythm ; 18(5): 734-742, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33091601

RESUMEN

BACKGROUND: The risk of heart block during radiofrequency ablation of atrioventricular (AV) nodal reentrant tachycardia and septal accessory pathways is minimized by rapidly ceasing ablation in response to markers of risk, such as atrioventricular dissociation, fast junctional rhythm, PR interval prolongation, or 2 consecutive atrial or ventricular depolarizations. Currently this is done manually. OBJECTIVES: The objectives of this study were to build and test a control system able to monitor cardiac rhythm and automatically terminate ablation energy when required. METHODS: The device was built from off-shelf componentry. Preclinical testing involved real-time input of electrogram/electrocardiogram data from 209 ablation procedures (20 patients) over slow (n = 19) and fast (n = 1) AV nodal pathways. The device response speed was compared with the human response speed. The device's ability to prevent heart block was tested in 5 sheep. First-in-human testing was then performed in 12 patients undergoing AV nodal reentrant tachycardia ablation. RESULTS: Risk conditions necessitating shutoff of ablation (200 total; 111 preclinical and 89 first-in-human) were detected by the device with 100% sensitivity and 94% specificity, automatically terminating ablation while still allowing successful ablation in all patients. Device shutoff of ablation was always faster than human response (median difference 1.24 seconds). In each of 5 sheep, 40 consecutive attempts to cause heart block by ablating over the His bundle were unsuccessful because of automatic shutoff in response to rhythm change. CONCLUSION: Automated shutoff of ablation close to the AV node in response to markers of the risk of heart block is feasible with high accuracy as well as faster response than human response. The system may improve the safety of ablation near the AV node by preventing heart block.


Asunto(s)
Nodo Atrioventricular/fisiopatología , Estimulación Cardíaca Artificial/métodos , Ablación por Catéter/métodos , Taquicardia por Reentrada en el Nodo Atrioventricular/terapia , Animales , Modelos Animales de Enfermedad , Electrocardiografía , Humanos , Ovinos
6.
JACC Clin Electrophysiol ; 6(11): 1420-1431, 2020 10 26.
Artículo en Inglés | MEDLINE | ID: mdl-33121671

RESUMEN

OBJECTIVES: The aim of this study was to assess the long-term efficacy and outcomes of retrograde venous ethanol ablation in treating ventricular arrhythmias (VAs). BACKGROUND: Retrograde coronary venous ethanol ablation (RCVEA) can be effective for radiofrequency ablation (RFA)-refractory VAs, particularly those arising in the LV summit (LVS). METHODS: Patients with drug and RFA-refractory VAs were considered for RCVEA after RF failure attempts. Intramural coronary veins (tributaries of the great cardiac, anterior interventricular, lateral cardiac, posterolateral, and middle cardiac) were mapped using an angioplasty wire. Ethanol infusion was delivered in veins with appropriate signals. RESULTS: Of 63 patients (age 63 ± 14 years; 60% men) with VAs (71% extrasystole, 29% ventricular tachycardia, 76% LVS origin), RCVEA was performed in 56 patients who had suitable vein branches. These were defined as those amenable to cannulation and with intramural signals that preceded those mapped in the epicardium or endocardium and had better matching pace maps or entrainment responses. Seven patients had no suitable veins and underwent RFA. In 38 of 56 (68%) patients, the VAs were successfully terminated exclusively with ethanol infusion. In 17 of 56 (30%) patients, successful ablation was achieved using ethanol with adjunctive RFA in the vicinity of the infused vein due to acute recurrence or ethanol-induced change in VA morphology. Overall, isolated or adjuvant RCVEA was successful in 55 of 56 (98%) patients. At 1-year follow-up, 77% of patients were free of recurrent arrhythmias. Procedural complications included 2 venous dissections that led to pericardial effusions. CONCLUSIONS: RCVEA offers a significant long-term effective treatment for patients with drug and RF-refractory VAs.


Asunto(s)
Etanol , Taquicardia Ventricular , Arritmias Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pericardio , Taquicardia Ventricular/tratamiento farmacológico , Resultado del Tratamiento
8.
JACC Clin Electrophysiol ; 6(7): 815-826, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32703564

RESUMEN

OBJECTIVES: This study systematically evaluated mechanisms of atrial tachycardia (AT) by using ultra-high-resolution mapping in a large cohort of patients. BACKGROUND: An incomplete understanding of the mechanism of AT is a major determinant of ablation failure. METHODS: Consecutive patients with ≥1 AT (excluding cavotricuspid isthmus-dependent flutter) were included. Mapping was performed with a 64-pole mapping catheter. The AT mechanism was defined based on activation mapping and confirmed by entrainment in selected cases. RESULTS: A total of 132 patients were included (60 ± 12 years; 31 [23%] female; 111 [84%] previous atrial fibrillation [AF] ablation; 5 [4%] previous left atriotomy). One hundred four (94%) of the 111 post-AF ablation AT patients had substrate-based ablation during the index AF ablation. A total of 214 ATs were mapped, with complete definition of the AT mechanism in 206 (96%). A total of 129 (60%) had anatomic macro-re-entry (circuit diameter 44.2 ± 9.6 mm), 57 (27%) had scar-related localized re-entry (circuit diameter 25.8 ± 12.2 mm), and 20 (9%) had focal AT. Fifty-eight (45%) patients had multiple ATs (27 [20%] dual-loop re-entry; 60 [43%] sequential AT) with complex and highly variable transitions between AT circuits. A total of 116 (90%) of 129 macro-re-entrant ATs, 56 (98%) of 57 localized AT, and 20 (100%) of 20 focal ATs terminated after radiofrequency ablation. After a mean follow-up of 13 ± 9 months, 57 (46%) patients experienced recurrence of AT. CONCLUSIONS: Among patients with AT in the context of previous atrial interventions, particularly post-AF ablation patients, multiple complex AT circuits are common. Despite complete delineation of arrhythmia circuits using ultra-high-resolution mapping and high acute ablation success rates, long-term freedom from AT is modest.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Taquicardia Supraventricular , Fibrilación Atrial/cirugía , Femenino , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Humanos , Taquicardia Supraventricular/cirugía , Resultado del Tratamiento
9.
J Am Coll Cardiol ; 75(21): 2698-2707, 2020 06 02.
Artículo en Inglés | MEDLINE | ID: mdl-32466885

RESUMEN

BACKGROUND: The relative proportion of each cardiac inherited disease (CID) causing resuscitated sudden cardiac arrest (RSCA) on a population basis is unknown. OBJECTIVES: This study describes the profile of patients with CIDs presenting with RSCA; their data were collected by the national Cardiac Inherited Diseases Registry New Zealand (CIDRNZ). METHODS: Data were collated from CIDRNZ probands presenting with RSCA (2002 to 2018). RESULTS: CID was identified in 115 (51%) of 225 RSCA cases: long QT syndrome (LQTS) (n = 48 [42%]), hypertrophic cardiomyopathy (HCM) (n = 28 [24%]), Brugada syndrome (BrS) (n = 16 [14%]), catecholaminergic polymorphic ventricular tachycardia (CPVT) (n = 9 [8%]), arrhythmogenic right ventricular cardiomyopathy (ARVC) (n = 9 [8%]), and dilated cardiomyopathy (n = 5 [4%]). Seventy-one (62%) of 115 were male. Of 725 probands from the CIDRNZ with CID, the proportion presenting with RSCA was: CPVT, 9 (53%) of 17; BrS, 16 (33%) of 49; ARVC, 9 (25%) of 36; LQTS, 48 (20%) of 238; dilated cardiomyopathy, 5 (9%) of 58; and HCM, 28 (8%) of 354. Incident activity was: normal everyday activities, 44 (40%); exercising, 33 (30%); concurrent illness, 13 (12%); sleeping, 10 (9%); drugs/medication, 9 (8%); and emotion, 2 (2%). LQTS and CPVT predominated in those <24 years of age, 30 (77%) of 39; cardiomyopathies and BrS predominated in those >24 years of age, 49 (64%) of 76. For those >40 years of age, HCM was the most common (33%) CID. A genetic diagnosis in patients with CID was made in 48 (49%) of 98 tested. Diagnosis by age range was as follows: age 1 to 14 years, 78%; age 15 to 24 years, 53%; age 25 to 39 years, 54%; and age >40 years, 26%. CONCLUSIONS: The commonest CID identified after RSCA was LQTS; the most common CID cause of RSCA for those >40 years of age was HCM. CPVT was the CID most likely to present with RSCA and HCM the least. Genetic yield decreases with age. Only one-third of RSCA cases due to CID occurred while exercising.


Asunto(s)
Paro Cardíaco/genética , Cardiopatías Congénitas/complicaciones , Sistema de Registros , Adolescente , Adulto , Anciano , Niño , Preescolar , Femenino , Paro Cardíaco/epidemiología , Humanos , Lactante , Recién Nacido , Masculino , Persona de Mediana Edad , Nueva Zelanda/epidemiología , Adulto Joven
10.
Intern Med J ; 50(10): 1247-1252, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32043731

RESUMEN

BACKGROUND: Catheter ablation has rapidly become an integral part of the management of many arrhythmias. AIMS: To provide a history of clinical cardiac electrophysiology (EP) in New Zealand (NZ) and analysis of recent trends in EP procedures and catheter ablations across NZ, which has not previously been reported. METHODS: EP case type and volume were obtained from the EP databases from each of the four public and four private EP centres in NZ from 1 January 2014 to 31 December 2018. Procedure rates were expressed as per million population. RESULTS: A total of 7695 EP cases was performed, including 5929 (77%) in the public sector. Atrial fibrillation (AF) ablation was the most common procedure at 29%. EP procedure rates increased by 21% (to 353 per million in 2018), predominantly due to AF ablation rates increasing by 46%. Ventricular tachycardia ablation rates increased by 41% but only comprised 8% of procedures. There was a striking difference in the growth of EP procedure rates in the public compared to the private sector (4% vs 106%), as well as considerable differences in EP procedure and AF ablation rates across the public EP centres. NZ had lower ablation rates compared to countries with similar healthcare expenditure. CONCLUSION: There has been a substantial increase in EP procedure and AF ablation rates in NZ and international trends suggest this growth will continue. However, there is considerable variation in procedure rates and growth trends between EP centres, highlighting inequities in access within the country.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fibrilación Atrial/cirugía , Electrofisiología Cardíaca , Técnicas Electrofisiológicas Cardíacas , Humanos , Nueva Zelanda/epidemiología , Resultado del Tratamiento
11.
Europace ; 22(1): 109-116, 2020 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-31909432

RESUMEN

AIMS: Our study assesses the value of electrograms (EGMs) characteristics to identify a ventricular tachycardia (VT) isthmus entrance in patients with post-infarct VT. Post-infarct VTs are mostly due to a re-entrant circuit. A pacemapping (PM) approach is able to localize the VT isthmus during sinus rhythm. Limited data are available about the role of local EGMs in defining VT isthmus location. METHODS AND RESULTS: Twenty consecutive patients (70% male) referred for post-infarct VT catheter ablation were included in the present study. The VT isthmus was defined according to the PM method. At each recording site, 10 characteristics of the local EGM were assessed to predict the location of the VT isthmus entrance. In total, 924 EGMs were acquired, of which 127 were located in the VT isthmus entrance. Logistic regression analysis showed that bipolar voltage, number of EGM positive peaks, and sQRS interval were independently associated with VT isthmus entrance location. The ROC curve best fitted the model at the cut-off 0.1641 (sensitivity 72%, specificity 75.2%, positive predictive value 31.3%, negative predictive value 94.4%, area under the curve 0.78, P < 0.001). Based upon these results, we developed an algorithm implemented in an automatic calculator to determine the likelihood that an EGM is located at a VT isthmus entrance. CONCLUSION: Our study suggests that three EGM characteristics: bipolar voltage, number of positive peaks, and sQRS interval can successfully identify a VT isthmus entrance in post-infarct patients.


Asunto(s)
Ablación por Catéter , Infarto del Miocardio , Taquicardia Ventricular , Algoritmos , Femenino , Sistema de Conducción Cardíaco/cirugía , Humanos , Masculino , Infarto del Miocardio/complicaciones , Infarto del Miocardio/diagnóstico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/cirugía
13.
Front Physiol ; 9: 1458, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30459630

RESUMEN

AF is a heterogeneous rhythm disorder that is related to a wide spectrum of etiologies and has broad clinical presentations. Mechanisms underlying AF are complex and remain incompletely understood despite extensive research. They associate interactions between triggers, substrate and modulators including ionic and anatomic remodeling, genetic predisposition and neuro-humoral contributors. The pulmonary veins play a key role in the pathogenesis of AF and their isolation is associated to high rates of AF freedom in patients with paroxysmal AF. However, ablation of persistent AF remains less effective, mainly limited by the difficulty to identify the sources sustaining AF. Many theories were advanced to explain the perpetuation of this form of AF, ranging from a single localized focal and reentrant source to diffuse bi-atrial multiple wavelets. Translating these mechanisms to the clinical practice remains challenging and limited by the spatio-temporal resolution of the mapping techniques. AF is driven by focal or reentrant activities that are initially clustered in a relatively limited atrial surface then disseminate everywhere in both atria. Evidence for structural remodeling, mainly represented by atrial fibrosis suggests that reentrant activities using anatomical substrate are the key mechanism sustaining AF. These reentries can be endocardial, epicardial, and intramural which makes them less accessible for mapping and for ablation. Subsequently, early interventions before irreversible remodeling are of major importance. Circumferential pulmonary vein isolation remains the cornerstone of the treatment of AF, regardless of the AF form and of the AF duration. No ablation strategy consistently demonstrated superiority to pulmonary vein isolation in preventing long term recurrences of atrial arrhythmias. Further research that allows accurate identification of the mechanisms underlying AF and efficient ablation should improve the results of PsAF ablation.

15.
J Cardiovasc Electrophysiol ; 29(7): 1024-1031, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29656578

RESUMEN

INTRODUCTION: ICD lead failure is a potential source of significant morbidity and mortality. This study investigates the survival rates of Sprint Quattro, Endotak Reliance, and Linox ICD leads. METHODS AND RESULTS: A retrospective cohort study of all patients with an ICD implanted between January 2007 and December 2012 from the Wellington Hospital region, New Zealand, a tertiary referral center. Lead and patient details were established by review of clinical notes and the PaceArt Optima database. We analyzed a total of 287 implants using Sprint Quattro (n  =  92), Endotak Reliance (n  =  37), Linox (n  =  151), Riata (n  =  4), and Sprint Fidelis (n  =  2) leads. Median follow-up was 61.6 (26.0-81.6) months for Sprint Quattro leads, 66.7 (53.3-88.8) months for Linox leads, and 82.9 (45.9-107.4) months for Endotak Reliance leads. There were 20 cases of lead failure of which 19 were in Linox leads. The 4-, 6-, and 8-year survival for Linox leads was 97% (92.6-99.1), 93% (85.5-96.5), and 76% (62.3-85.5), respectively. The predominant abnormality was detection of nonphysiological electrical signals. Linox lead failure was associated with a younger age of patient (49.2 vs. 57.7 years, P  =  0.007). CONCLUSIONS: The 7-year survival of Linox leads was significantly worse than shown in Biotronik surveillance reports, but in line with other single-center studies from around the world.


Asunto(s)
Electrodos Implantados/efectos adversos , Diseño de Equipo/efectos adversos , Análisis de Falla de Equipo/métodos , Falla de Equipo , Adulto , Anciano , Estudios de Cohortes , Electrodos Implantados/tendencias , Diseño de Equipo/tendencias , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Tiempo
16.
JACC Clin Electrophysiol ; 4(1): 17-29, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29479568

RESUMEN

OBJECTIVES: This study sought to assess the relationship between fibrosis and re-entrant activity in persistent atrial fibrillation (AF). BACKGROUND: The mechanisms involved in sustaining re-entrant activity during AF are poorly understood. METHODS: Forty-one patients with persistent AF (age 56 ± 12 years; 6 women) were evaluated. High-resolution electrocardiographic imaging (ECGI) was performed during AF by using a 252-chest electrode array, and phase mapping was applied to locate re-entrant activity. Sites of high re-entrant activity were defined as re-entrant regions. Late gadolinium-enhanced (LGE) cardiac magnetic resonance (CMR) was performed at 1.25 × 1.25 × 2.5 mm resolution to characterize atrial fibrosis and measure atrial volumes. The relationship between LGE burden and the number of re-entrant regions was analyzed. Local LGE density was computed and characterized at re-entrant sites. All patients underwent catheter ablation targeting re-entrant regions, the procedural endpoint being AF termination. Clinical, CMR, and ECGI predictors of acute procedural success were then analyzed. RESULTS: Left atrial (LA) LGE burden was 22.1 ± 5.9% of the wall, and LA volume was 74 ± 21 ml/m2. The number of re-entrant regions was 4.3 ± 1.7 per patient. LA LGE imaging was significantly associated with the number of re-entrant regions (R = 0.52, p = 0.001), LA volume (R = 0.62, p < 0.0001), and AF duration (R = 0.54, p = 0.0007). Regional analysis demonstrated a clustering of re-entrant activity at LGE borders. Areas with high re-entrant activity showed higher local LGE density as compared with the remaining atrial areas (p < 0.0001). Failure to achieve AF termination during ablation was associated with higher LA LGE burden (p < 0.001), higher number of re-entrant regions (p < 0.001), and longer AF duration (p = 0.008). CONCLUSIONS: The number of re-entrant regions during AF relates to the extent of LGE on CMR, with the location of these regions clustering to LGE areas. These characteristics affect procedural outcomes of ablation.


Asunto(s)
Fibrilación Atrial , Cardiomiopatías , Electrocardiografía , Imagen por Resonancia Magnética , Adulto , Anciano , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/epidemiología , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Técnicas de Imagen Cardíaca , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/epidemiología , Ablación por Catéter , Femenino , Gadolinio/uso terapéutico , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad
17.
Pacing Clin Electrophysiol ; 41(6): 666-668, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29318634

RESUMEN

We report a case of recurrent focal atrial tachycardia (AT) which mechanisms could be resolved by using noninvasive electrocardiographic imaging (ECGI) reconstructing epicardial potentials and rapid high-density endocardial contact mapping (Rhythmia™, Boston Scientific, Natick, MA, USA). ECGI demonstrated focal activity from the anterior of the left superior pulmonary vein antrum, although Rhythmia™ showed focal activity from the high anterior left atrium with the 2nd focus originating from the site where identical to the focus on the ECGI map with slightly delay (by 8 ms). Elimination of the AT by radiofrequency applications for both of the endocardial focuses indicated the dual endocardial exits from an epicardial focus.


Asunto(s)
Electrocardiografía , Mapeo Epicárdico , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatología , Adulto , Diagnóstico Diferencial , Femenino , Humanos , Recurrencia
18.
J Cardiovasc Electrophysiol ; 29(2): 274-283, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29072796

RESUMEN

INTRODUCTION: It is largely believed that atrial tachycardias (ATs) encountered during ablation of persistent atrial fibrillation (PsAF) are a byproduct of ablative lesions. We aimed to explore the alternative hypothesis that they may be a priori drivers of AF remaining masked until other AF sources are reduced or eliminated. METHODS AND RESULTS: Radiofrequency ablation of fibrillatory drivers mapped by electrocardiographic imaging (ECGI; ECVUE™, Cardioinsight Technologies, Cleveland, OH, USA) terminated PsAF in 198 (73%) out of 270 patients (61 ± 10 years, 9 ± 9 m). Two hundred and six ATs in 158 patients were subsequently mapped. Their anatomic relationship to the fibrillatory drivers prospectively identified by ECGI was then established. There were 26 (13%), 52 (25%), and 128 (62%) focal, localized, and macrore-entrant ATs, respectively. In focal/localized re-entrant ATs, 64 (82%) were terminated within an AF-driver region, in which 26 (81%) among 32 focal/localized ATs analyzed with 3-D-mapping system merged to driver map occurred from AF-driver regions in 1.0 ± 1.0 cm distance from the driver core. Importantly, there was no attempt at ablation of the associated AF-driver region in 25 of 64 (39%) of focal/localized re-entrant ATs. The sites of ATs origin generally had low-voltage, fractionated, and long-duration electrograms in AF. All but two focal/localized re-entrant ATs were successfully ablated. CONCLUSION: The majority of post-AF-ablation focal and localized re-entrant ATs originate from the region of prospectively established AF-driver regions. A third of these are localized to regions not subsequently submitted to ablation. These data suggest that many ATs exist, although not necessarily manifest independently, prior to ablation. They may have a role in the maintenance of PsAF in these individuals.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Taquicardia Supraventricular/cirugía , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
19.
Heart Rhythm ; 14(2): 155-163, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-28104088

RESUMEN

BACKGROUND: Scar-related ventricular tachycardia (VT) arises from specific substrate according to etiology. OBJECTIVE: The purpose of this study was to evaluate the relationship between wall thinning (WT) on multidetector computed tomography (MDCT) and local abnormal ventricular activity (LAVA) in patients with ischemic cardiomyopathy (ICM), postmyocarditis (PMC), and dilated cardiomyopathy (DCM). METHODS: Forty-two patients (40 male, age 58 ± 13 years, 22 ICM, 11 PMC, 9 DCM) underwent MDCT before a combined endo-/epicardial VT ablation procedure. WT (<5 mm) and severe wall thinning (SWT) (<2 mm) area on MDCT were compared to the prevalence of endo-/epicardial LAVA during sinus rhythm. RESULTS: WT and SWT were found on MDCT in 36 (86%) and 20 (48%) with 42 ± 37 cm2 and 26 ± 24 cm2, respectively. SWT was frequently detected in ICM (ICM 77% vs PMC 27% vs DCM 0%, P <.001). LAVA were frequently observed on the endocardium in ICM and on the epicardium in PMC. Endo-/epicardial facing LAVA were frequently found within SWT areas (91% in <2 mm, 9% in 2-5 mm, and 0% in >5 mm, P < .001). In SWT areas, the presence of endocardial LAVA in ICM and epicardial LAVA in PMC predicted opposite facing LAVA with sensitivity and specificity of 78% and 48% and 79% and 98%, respectively. SWT predicted epicardial LAVA in ICM and endocardial LAVA in PMC with sensitivity and specificity of 89% and 100%, and 100% and 100%, respectively. CONCLUSION: SWT is frequently found in ICM and PMC but is not common in DCM. SWT predicts LAVA on the opposite side of the wall (epicardial in ICM and endocardial in PMC), indicating transmural VT substrate. MDCT is useful for identifying VT substrate and helpful for understanding the mechanisms of the location of VT substrate domain.


Asunto(s)
Cardiomiopatía Dilatada/complicaciones , Cicatriz , Isquemia Miocárdica/complicaciones , Miocarditis/complicaciones , Miocardio/patología , Taquicardia Ventricular , Anciano , Cicatriz/diagnóstico por imagen , Cicatriz/etiología , Cicatriz/fisiopatología , Técnicas Electrofisiológicas Cardíacas/métodos , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Humanos , Imagenología Tridimensional/métodos , Masculino , Persona de Mediana Edad , Tomografía Computarizada Multidetector/métodos , Pronóstico , Sensibilidad y Especificidad , Taquicardia Ventricular/etiología , Taquicardia Ventricular/patología , Taquicardia Ventricular/fisiopatología
20.
Artículo en Inglés | MEDLINE | ID: mdl-27406604

RESUMEN

BACKGROUND: During the past years, many innovations have been introduced to facilitate catheter ablation of post-myocardial infarction ventricular tachycardia. However, the predictors of outcome after ablation were not thoroughly studied. METHODS AND RESULTS: From 2009 to 2013, consecutive patients referred for post-myocardial infarction ventricular tachycardia ablation were included. The end point of the procedure was complete elimination of local abnormal ventricular activities (LAVA) and ventricular tachycardia (VT) noninducibility. The predictors of outcome with primary end point of VT recurrence were assessed. A total of 125 patients were included (age: 64±11 years; 7 women) for 142 procedures. The left ventricle was accessed via transseptal, retrograde aortic, and epicardial approaches in 87%, 33%, and 37% of patients, respectively. Three-dimensional electroanatomical mapping system was used in 70%, multipolar catheter in 51%, and real-time image integration in 38% (from magnetic resonance imaging in 39% and multidetector computed tomography in 93%) of patients. Before ablation, VT was inducible in 75%, and endocardial/epicardial LAVA were present in 88%/75%. After ablation, complete LAVA elimination was achieved in 60%, and VT noninducibility in 83%. During a median follow-up of 850 days (interquartile range, 439-1707), VT recurrence was observed in 36%. Multivariable analysis identified 3 independent outcome predictors: the ability to achieve complete LAVA elimination (R(2)=0.29; P<0.0001; risk ratio=0.52 [0.38-0.70]), the use of real-time image integration (R(2)=0.21; P=0.0006; risk ratio=0.49 [0.33-0.74]), and the use of multipolar catheters (R(2)=0.08; P=0.05; risk ratio=0.75 [0.56-1.00]). CONCLUSIONS: Achievement of complete LAVA elimination and use of scar integration from imaging and multipolar catheters to focus high-density mapping are independent predictors of VT-free survival after catheter ablation for post-myocardial infarction ventricular tachycardia.


Asunto(s)
Ablación por Catéter/métodos , Mapeo Epicárdico/métodos , Infarto del Miocardio/complicaciones , Infarto del Miocardio/cirugía , Taquicardia Ventricular/etiología , Taquicardia Ventricular/cirugía , Anciano , Ablación por Catéter/instrumentación , Electrocardiografía , Mapeo Epicárdico/instrumentación , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Infarto del Miocardio/fisiopatología , Taquicardia Ventricular/fisiopatología , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA