Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Trauma Acute Care Surg ; 95(2S Suppl 1): S13-S18, 2023 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-37246291

RESUMEN

OBJECTIVES: The objective of this study is to describe the United States and allied military medical response during the withdrawal from Afghanistan. BACKGROUND: The military withdrawal from Afghanistan concluded with severe hostilities resulting in numerous civilian and military casualties. The clinical care provided by coalition forces capitalized on decades of lessons learned and enabled unprecedented accomplishments. METHODS: In this retrospective, observational analysis, casualty numbers, and operative information was collected and reported from military medical assets in Kabul, Afghanistan. The continuum of medical care and the trauma system, from the point of injury back to the United States was captured and described. RESULTS: Prior to a large suicide bombing resulting in a mass casualty event, the international medical teams managed distinct 45 trauma incidents involving nearly 200 combat and non-combat civilian and military patients over the preceding 3 months. Military medical personnel treated 63 casualties from the Kabul airport suicide attack and performed 15 trauma operations. US air transport teams evacuated 37 patients within 15 hours of the attack. CONCLUSION: Lessons learned from the last 20 years of combat casualty care were successfully implemented during the culmination of the Afghanistan conflict. Ultimately, the effort, teamwork, and system adaptability exemplify not only the attitudes and character of service members who provide modern combat casualty care but also the paramount importance of the battlefield learning health care system. A continued posture to maintain military surgical preparedness in unique environments remain crucial as the US military prepares for the future.Retrospective observational analysis. LEVEL OF EVIDENCE: Therapeutic/Care Management; Level V.


Asunto(s)
Incidentes con Víctimas en Masa , Medicina Militar , Personal Militar , Heridas y Lesiones , Humanos , Estados Unidos , Estudios Retrospectivos , Afganistán , Medicina Militar/métodos , Campaña Afgana 2001-
2.
ASAIO J ; 58(4): 415-9, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22717588

RESUMEN

Extracorporeal membrane oxygenation (ECMO) is often used to provide cardiopulmonary support for infants experiencing severe levels of cardiac or respiratory failure. In patients with two ventricles and no intra-atrial communication, ECMO is often complicated by limited venous return to the circuit and marked left atrial hypertension. This condition may be treated by performing an atrial septostomy to create an intentional atrial septal defect (ASD). A pediatric mock circulation with a conduit connecting the left and right atrium was used to examine the size of ASD that would relieve left atrial hypertension and restore acceptable hemodynamics in a 4 to 5 kg infant. After creation of left ventricular failure and subsequent institution of ECMO, the ASD was opened in a graded fashion while the resulting hemodynamic changes were recorded. An ASD equivalent to a 6.3 mm diameter hole decreased the left atrial pressure 30 mmHg to an acceptable level with a net left-to-right shunt of 393 ml/min. Further opening of the ASD resulted in additional hemodynamic improvement, but was eventually limited in further effect. This study demonstrates that a mock circulation can be used to investigate the size of an ASD necessary to effect sufficient clinical improvement in a two-ventricle infant on ECMO.


Asunto(s)
Oxigenación por Membrana Extracorpórea/métodos , Insuficiencia Cardíaca/cirugía , Defectos del Tabique Interatrial/cirugía , Cardiología/métodos , Niño , Simulación por Computador , Atrios Cardíacos/patología , Insuficiencia Cardíaca/terapia , Defectos del Tabique Interatrial/terapia , Hemodinámica , Humanos , Hipertensión/prevención & control , Modelos Cardiovasculares , Pediatría/métodos , Insuficiencia Respiratoria , Vasodilatación
3.
J Neurother ; 14(3): 195-216, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20976131

RESUMEN

INTRODUCTION: Preoccupation with drug and drug-related items is a typical characteristic of cocaine addicted individuals. It has been shown in multiple accounts that prolonged drug use has a profound effect on the EEG recordings of drug addicts when compared to controls during cue reactivity tests. Cue reactivity refers to a phenomenon in which individuals with a history of drug abuse exhibit excessive psychophysiological responses to cues associated with their drug of choice. One of the aims of this pilot study was to determine the presence of an attentional bias to preferentially process drug-related cues using evoked and induced gamma reactivity measures in cocaine addicts before and after biobehavioral treatment based on neurofeedback. Another aim was to show that central SMR amplitude increase and frontal theta control is possible in an experimental outpatient drug users group over 12 neurofeedback sessions. METHOD: Ten current cocaine abusers participated in this pilot research study using neurofeedback combined with Motivational Interviewing sessions. Eight of them completed all planned pre- and post -neurofeedback cue reactivity tests with event-related EEG recording and clinical evaluations. Cue reactivity test represented a visual oddball task with images from the International Affective Picture System and drug-related pictures. Evoked and induced gamma responses to target and non-target drug cues were analyzed using wavelet analysis. RESULTS: Outpatient subjects with cocaine addiction completed the biobehavioral intervention and successfully increased SMR while keeping theta practically unchanged in 12 sessions of neurofeedback training. The addition of Motivational Interviewing helped retain patients in the study. Clinical evaluations immediately after completion of the treatment showed decreased self-reports on depression and stress scores, and urine tests collaborated reports of decreased use of cocaine and marijuana. Effects of neurofeedback resulted in a lower EEG gamma reactivity to drug-related images in a post-neurofeedback cue reactivity test. In particular, evoked gamma showed decreases in power to non-target and to a lesser extent target drug-related cues at all topographies (left, right, frontal, parietal, medial, inferior); while induced gamma power decreased globally to both target and non-target drug cues. Our findings supported our hypothesis that gamma band cue reactivity measures are sufficiently sensitive functional outcomes of neurofeedback treatment. Both evoked and induced gamma measures were found capable to detect changes in responsiveness to both target and non-target drug cues. CONCLUSION: Our study emphasizes the utility of cognitive neuroscience methods based on EEG gamma band measures for the assessment of the functional outcomes of neurofeedback-based biobehavioral interventions for cocaine use disorders. This approach may have significant potential for identifying both physiological and clinical markers of treatment progress. The results confirmed our prediction that EEG changes achieved with neurofeedback training will be accompanied by positive EEG outcomes in a cue reactivity and clinical improvements.

4.
J Neurother ; 14(2): 79-95, 2010 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-20523752

RESUMEN

INTRODUCTION: Error monitoring and correction is one of the executive functions and is important for effective goal directed behavior. Deficient executive functioning, including reduced error monitoring ability, is one of the typical features of such neurodevelopmental disorders as autism, probably related to perseverative responding, stereotyped repetitive behaviors, and an inability to accurately monitor ongoing behavior. Our prior studies of behavioral and event-related potential (ERP) measures during performance on visual oddball tasks in high-functioning autistic (HFA) children showed that despite only minor differences in reaction times HFA children committed significantly more errors. METHODS: This study investigated error monitoring in children with autism spectrum disorder (ASD) with response-locked event-related potentials - the Error-related Negativity (ERN) and Error-related Positivity (Pe) recorded at fronto-central sites. The ERN reflects early error detection processes, while the Pe has been associated with later conscious error evaluation and attention re-allocation. Reaction times (RT) in correct trials and post-error slowing in reaction times were measured. In this study fourteen subjects with ASD and 14 age- and IQ- matched controls received a three-category visual oddball task with novel distracters. RESULTS: ERN had a lower amplitude and longer latency in the ASD group but was localized in the caudal part of anterior cingulate cortex (ACC) in both groups. The Pe component was significantly prolonged in the ASD group but did not reach significance in amplitude differences compared to controls. We found significant post-error slowing in RTs in controls, and post-error acceleration in RTs in the ASD group. CONCLUSIONS: The reduced ERN and altered Pe along with a lack of post-error RT slowing in autism might be interpreted as insensitivity in the detection and monitoring of response errors and a reduced ability of execute corrective actions. This might result in reduced error awareness and failure in adjustment when dealing with situations where erroneous responses may occur. This deficit might be manifested in the perseverative behaviors often seen in individuals with ASD. The results are discussed in terms of a general impairment in self-monitoring and other executive functions underlying behavioral and social disturbances in ASD.

5.
Tex Heart Inst J ; 36(1): 12-6, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19436780

RESUMEN

Pulsatile ventricular assist devices have successfully provided circulatory support for many patients throughout the past quarter century; however, persistent complications have hindered expanded clinical application of this technology. Although the use of smaller, continuous-flow ventricular assist device pumps has reduced the frequency and severity of some adverse events, design enhancement may further improve outcomes for patients who require long-term left ventricular support. One new product, the HeartWare, Inc., miniature ventricular assist device, features a wide-bladed rotor design in an axial-flow pump with a strong, passively suspended magnetic rotor. The operating range of 16,000 to 28,000 rpm can provide up to 10 L/min of flow. The wide blades portend minimal cellular trauma.This new device has not yet been approved for use in human beings. As a test, we implanted it in a calf, and we continuously monitored the device's performance and the hemodynamic results over 30 days. No mechanical failure occurred, and no thrombi were noted upon explantation of the device. The animal's circulation was stable during the test period, and no end-organ abnormalities were found upon autopsy. The potential benefits of this miniature ventricular assist device are its increased availability to a broader patient population, a lower risk of infection, simplified implantation procedures, and improved durability. Further in vivo testing is planned. Herein, we discuss the unique design of the HeartWare miniature ventricular assist device, our feasibility study of its performance, and the possibilities for its use in human beings.


Asunto(s)
Corazón Auxiliar , Hemodinámica , Implantación de Prótesis , Animales , Bovinos , Estudios de Factibilidad , Corazón Auxiliar/efectos adversos , Humanos , Magnetismo , Ensayo de Materiales , Miniaturización , Diseño de Prótesis , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA