Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Biosens Bioelectron ; 263: 116597, 2024 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-39059179

RESUMEN

Traditional temporary cardiac pacemakers (TCPs), which employ transcutaneous leads and external wired power systems are battery-dependent and generally non-absorbable with rigidity, thereby necessitating surgical retrieval after therapy and resulting in potentially severe complications. Wireless and bioresorbable transient pacemakers have, hence, emerged recently, though hitting a bottleneck of unfavorable tissue-device bonding interface subject to mismatched mechanical modulus, low adhesive strength, inferior electrical performances, and infection risks. Here, to address such crux, we develop a multifunctional interface hydrogel (MIH) with superior electrical performance to facilitate efficient electrical exchange, comparable mechanical strength to natural heart tissue, robust adhesion property to enable stable device-tissue fixation (tensile strength: ∼30 kPa, shear strength of ∼30 kPa, and peel-off strength: ∼85 kPa), and good bactericidal effect to suppress bacterial growth. Through delicate integration of this versatile MIH with a leadless, battery-free, wireless, and transient pacemaker, the entire system exhibits stable and conformal adhesion to the beating heart while enabling precise and constant electrical stimulation to modulate the cardiac rhythm. It is envisioned that this versatile MIH and the proposed integration framework will have immense potential in overcoming key limitations of traditional TCPs, and may inspire the design of novel bioelectronic-tissue interfaces for next-generation implantable medical devices.

2.
Nat Commun ; 15(1): 4474, 2024 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-38796514

RESUMEN

Olfaction feedback systems could be utilized to stimulate human emotion, increase alertness, provide clinical therapy, and establish immersive virtual environments. Currently, the reported olfaction feedback technologies still face a host of formidable challenges, including human perceivable delay in odor manipulation, unwieldy dimensions, and limited number of odor supplies. Herein, we report a general strategy to solve these problems, which associates with a wearable, high-performance olfactory interface based on miniaturized odor generators (OGs) with advanced artificial intelligence (AI) algorithms. The OGs serve as the core technology of the intelligent olfactory interface, which exhibit milestone advances in millisecond-level response time, milliwatt-scale power consumption, and the miniaturized size. Empowered by robust AI algorithms, the olfactory interface shows its great potentials in latency-free mixed reality (MR) and fast olfaction enhancement, thereby establishing a bridge between electronics and users for broad applications ranging from entertainment, to education, to medical treatment, and to human machine interfaces.


Asunto(s)
Algoritmos , Inteligencia Artificial , Odorantes , Olfato , Dispositivos Electrónicos Vestibles , Humanos , Olfato/fisiología , Interfaz Usuario-Computador , Adulto , Masculino
3.
Nature ; 628(8006): 84-92, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38538792

RESUMEN

Wearable electronics with great breathability enable a comfortable wearing experience and facilitate continuous biosignal monitoring over extended periods1-3. However, current research on permeable electronics is predominantly at the stage of electrode and substrate development, which is far behind practical applications with comprehensive integration with diverse electronic components (for example, circuitry, electronics, encapsulation)4-8. Achieving permeability and multifunctionality in a singular, integrated wearable electronic system remains a formidable challenge. Here we present a general strategy for integrated moisture-permeable wearable electronics based on three-dimensional liquid diode (3D LD) configurations. By constructing spatially heterogeneous wettability, the 3D LD unidirectionally self-pumps the sweat from the skin to the outlet at a maximum flow rate of 11.6 ml cm-2 min-1, 4,000 times greater than the physiological sweat rate during exercise, presenting exceptional skin-friendliness, user comfort and stable signal-reading behaviour even under sweating conditions. A detachable design incorporating a replaceable vapour/sweat-discharging substrate enables the reuse of soft circuitry/electronics, increasing its sustainability and cost-effectiveness. We demonstrated this fundamental technology in both advanced skin-integrated electronics and textile-integrated electronics, highlighting its potential for scalable, user-friendly wearable devices.


Asunto(s)
Electrónica , Dispositivos Electrónicos Vestibles , Piel , Textiles , Electrodos
4.
Sci Adv ; 10(2): eadk6301, 2024 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-38198552

RESUMEN

Miniaturized mobile electronic system is an effective candidate for in situ exploration of confined spaces. However, realizing such system still faces challenges in powering issue, untethered mobility, wireless data acquisition, sensing versatility, and integration in small scales. Here, we report a battery-free, wireless, and miniaturized soft electromagnetic swimmer (SES) electronic system that achieves multiple monitoring capability in confined water environments. Through radio frequency powering, the battery-free SES system demonstrates untethered motions in confined spaces with considerable moving speed under resonance. This system adopts soft electronic technologies to integrate thin multifunctional bio/chemical sensors and wireless data acquisition module, and performs real-time water quality and virus contamination detection with demonstrated promising limits of detection and high sensitivity. All sensing data are transmitted synchronously and displayed on a smartphone graphical user interface via near-field communication. Overall, this wireless smart system demonstrates broad potential for confined space exploration, ranging from pathogen detection to pollution investigation.


Asunto(s)
Electricidad , Calidad del Agua , Comunicación , Suministros de Energía Eléctrica , Electrónica
5.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 40(6): 1062-1070, 2023 Dec 25.
Artículo en Chino | MEDLINE | ID: mdl-38151928

RESUMEN

Electronic skin has shown great application potential in many fields such as healthcare monitoring and human-machine interaction due to their excellent sensing performance, mechanical properties and biocompatibility. This paper starts from the materials selection and structures design of electronic skin, and summarizes their different applications in the field of healthcare equipment, especially current development status of wearable sensors with different functions, as well as the application of electronic skin in virtual reality. The challenges of electronic skin in the field of wearable devices and healthcare, as well as our corresponding strategies, are discussed to provide a reference for further advancing the research of electronic skin.


Asunto(s)
Realidad Virtual , Dispositivos Electrónicos Vestibles , Humanos
6.
Nat Commun ; 14(1): 7539, 2023 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-37985765

RESUMEN

The rapid diagnosis of respiratory virus infection through breath and blow remains challenging. Here we develop a wireless, battery-free, multifunctional pathogenic infection diagnosis system (PIDS) for diagnosing SARS-CoV-2 infection and symptom severity by blow and breath within 110 s and 350 s, respectively. The accuracies reach to 100% and 92% for evaluating the infection and symptom severity of 42 participants, respectively. PIDS realizes simultaneous gaseous sample collection, biomarker identification, abnormal physical signs recording and machine learning analysis. We transform PIDS into other miniaturized wearable or portable electronic platforms that may widen the diagnostic modes at home, outdoors and public places. Collectively, we demonstrate a general-purpose technology for rapidly diagnosing respiratory pathogenic infection by breath and blow, alleviating the technical bottleneck of saliva and nasopharyngeal secretions. PIDS may serve as a complementary diagnostic tool for other point-of-care techniques and guide the symptomatic treatment of viral infections.


Asunto(s)
Líquidos Corporales , COVID-19 , Humanos , SARS-CoV-2 , COVID-19/diagnóstico , Manejo de Especímenes , Saliva
7.
ACS Nano ; 17(21): 21947-21961, 2023 11 14.
Artículo en Inglés | MEDLINE | ID: mdl-37917185

RESUMEN

Deaf-blindness limits daily human activities, especially interactive modes of audio and visual perception. Although the developed standards have been verified as alternative communication methods, they are uncommon to the nondisabled due to the complicated learning process and inefficiency in terms of communicating distance and throughput. Therefore, the development of communication techniques employing innate sensory abilities including olfaction related to the cerebral limbic system processing emotions, memories, and recognition has been suggested for reducing the training level and increasing communication efficiency. Here, a skin-integrated and wireless olfactory interface system exploiting arrays of miniaturized odor generators (OGs) based on melting/solidifying odorous wax to release smell is introduced for establishing an advanced communication system between deaf-blind and non-deaf-blind. By optimizing the structure design of the OGs, each OG device is as small as 0.24 cm3 (length × width × height of 11 mm × 10 mm × 2.2 mm), enabling integration of up to 8 OGs on the epidermis between nose and lip for direct and rapid olfactory drive with a weight of only 24.56 g. By generating single or mixed odors, different linked messages could be delivered to a user within a short period in a wireless and programmable way. By adopting the olfactory interface message delivery system, the recognition rates for the messages have been improved 1.5 times that of the touch-based method, while the response times were immensely decreased 4 times. Thus, the presented wearable olfactory interface system exhibits great potential as an alternative message delivery method for the deaf-blind.


Asunto(s)
Odorantes , Olfato , Humanos , Olfato/fisiología , Aprendizaje , Piel , Electrónica
8.
Bioeng Transl Med ; 8(6): e10445, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38023725

RESUMEN

Sepsis is a severe organ dysfunction typically caused by wound infection which leads to septic shock, organ failure or even death if no early diagnosis and property medical treatment were taken. Herein, we report a soft, wearable and battery-free wound dressing system (WDS) for wireless and real-time monitoring of wound condition and sepsis-related biomarker (procalcitonin [PCT]) in wound exudate for early sepsis detection. The battery-free WDS powered by near-field communication enables wireless data transmission, signal processing and power supply, which allows portable intelligent wound caring. The exudate collection associates with soft silicone based microfluidic technologies (exudate collection time within 15 s), that can filtrate contamination at the cell level and enable a superior filtration rate up to 95% with adopting microsphere structures. The battery-free WDS also includes state-of-the-art biosensors, which can accurate detect the pH value, wound temperature, and PCT level and thus for sepsis diagnosis. In vivo studies of SD rats prove the capability of the WDS for continuously monitoring wound condition and PCT concentration in the exudate. As a result, the reported fully integrated WDS provides a potential solution for further developing wearable, multifunctional and on-site disease diagnosis.

9.
Nat Commun ; 14(1): 5009, 2023 08 17.
Artículo en Inglés | MEDLINE | ID: mdl-37591881

RESUMEN

Continuous monitoring of arterial blood pressure (BP) outside of a clinical setting is crucial for preventing and diagnosing hypertension related diseases. However, current continuous BP monitoring instruments suffer from either bulky systems or poor user-device interfacial performance, hampering their applications in continuous BP monitoring. Here, we report a thin, soft, miniaturized system (TSMS) that combines a conformal piezoelectric sensor array, an active pressure adaptation unit, a signal processing module, and an advanced machine learning method, to allow real wearable, continuous wireless monitoring of ambulatory artery BP. By optimizing the materials selection, control/sampling strategy, and system integration, the TSMS exhibits improved interfacial performance while maintaining Grade A level measurement accuracy. Initial trials on 87 volunteers and clinical tracking of two hypertension individuals prove the capability of the TSMS as a reliable BP measurement product, and its feasibility and practical usability in precise BP control and personalized diagnosis schemes development.


Asunto(s)
Hipertensión , Dispositivos Electrónicos Vestibles , Humanos , Presión Arterial , Presión Sanguínea , Hipertensión/diagnóstico , Arterias
10.
Nat Commun ; 14(1): 2297, 2023 05 09.
Artículo en Inglés | MEDLINE | ID: mdl-37160931

RESUMEN

Recent advances in virtual reality (VR) technologies accelerate the creation of a flawless 3D virtual world to provide frontier social platform for human. Equally important to traditional visual, auditory and tactile sensations, olfaction exerts both physiological and psychological influences on humans. Here, we report a concept of skin-interfaced olfactory feedback systems with wirelessly, programmable capabilities based on arrays of flexible and miniaturized odor generators (OGs) for olfactory VR applications. By optimizing the materials selection, design layout, and power management, the OGs exhibit outstanding device performance in various aspects, from response rate, to odor concentration control, to long-term continuous operation, to high mechanical/electrical stability and to low power consumption. Representative demonstrations in 4D movie watching, smell message delivery, medical treatment, human emotion control and VR/AR based online teaching prove the great potential of the soft olfaction interface in various practical applications, including entertainment, education, human machine interfaces and so on.


Asunto(s)
Olfato , Realidad Virtual , Humanos , Escolaridad , Electricidad , Emociones
11.
Adv Sci (Weinh) ; 10(14): e2300504, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36825679

RESUMEN

A critical challenge lies in the development of the next-generation neural interface, in mechanically tissue-compatible fashion, that offer accurate, transient recording electrophysiological (EP) information and autonomous degradation after stable operation. Here, an ultrathin, lightweight, soft and multichannel neural interface is presented based on organic-electrochemical-transistor-(OECT)-based network, with capabilities of continuous high-fidelity mapping of neural signals and biosafety active degrading after performing functions. Such platform yields a high spatiotemporal resolution of 1.42 ms and 20 µm, with signal-to-noise ratio up to ≈37 dB. The implantable OECT arrays can well establish stable functional neural interfaces, designed as fully biodegradable electronic platforms in vivo. Demonstrated applications of such OECT implants include real-time monitoring of electrical activities from the cortical surface of rats under various conditions (e.g., narcosis, epileptic seizure, and electric stimuli) and electrocorticography mapping from 100 channels. This technology offers general applicability in neural interfaces, with great potential utility in treatment/diagnosis of neurological disorders.


Asunto(s)
Implantes Absorbibles , Fenómenos Electrofisiológicos , Ratas , Animales , Electrónica , Encéfalo/fisiología
12.
Adv Healthc Mater ; 12(15): e2202846, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36773301

RESUMEN

Intelligent monitoring human physiological information in real time raises the demand for skin-integrated electronics, as which is a flexible format and can be mounted onto the curved human skin for noninvasive healthcare monitoring. The biofluid such as sweat from skin contains abundant biomarkers reflecting body health conditions. Here, a skin-integrated sweat monitor with six biosensors embedded for the detection of NH4 + , Na+ , glucose, pH, skin impedance, and surface temperature is described, which could decode the information in the fresh sweat generated during exercising. Furthermore, the system also includes an innovative safety warning mechanism, which is based on a miniaturized actuator to provide mechanical stimuli, and coupled with six changeable colors light emitting diodes corresponding to the six biosensors for providing simultaneous safety alarming to users. The self-developed microfluidics system with a hydrophilic surface allows to enhance the sweat collection rate. Meanwhile, microfluidic filters can reduce the interruption of skin debris during biosignal monitoring. These state-of-art biosensors can real-time monitor health related signals with excellent linearity and specificity. The skin-integrated sweat monitor system exhibits a great potential in human healthcare monitoring and medical treatment.


Asunto(s)
Técnicas Biosensibles , Sudor , Humanos , Piel , Iones , Atención a la Salud
13.
Fundam Res ; 3(1): 111-117, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38933565

RESUMEN

With the requirements of self-powering sensors in flexible electronics, wearable triboelectric nanogenerators (TENGs) have attracted great attention due to their advantages of excellent electrical outputs and low-cost processing routes. The crosstalk effect between adjacent sensing units in TENGs significantly limits the pixel density of sensor arrays. Here, we present a skin-integrated, flexible TENG sensor array with 100 sensing units in an overall size of 7.5 cm × 7.5 cm that can be processed in a simple, low-cost, and scalable way enabled by 3D printing. All the sensing units show good sensitivity of 0.11 V/kPa with a wide range of pressure detection from 10 to 65 kPa, which allows to accurately distinguish various tactile formats from gentle touching (as low as 2 kPa) to hard pressuring. The 3D printing patterned substrate allows to cast triboelectric layers of polydimethylsiloxane in an independent sensing manner for each unit, which greatly suppresses the cross talk arising from adjacent sensing units, where the maximum crosstalk output is only 10.8%. The excellent uniformity and reproducibility of the sensor array offer precise pressure mapping for complicated pattern loadings, which demonstrates its potential in tactile sensing and human-machine interfaces.

14.
Sci Adv ; 8(51): eade2450, 2022 Dec 23.
Artículo en Inglés | MEDLINE | ID: mdl-36563155

RESUMEN

Tactile sensations are mainly transmitted to each other by physical touch. Wireless touch perception could be a revolution for us to interact with the world. Here, we report a wireless self-sensing and haptic-reproducing electronic skin (e-skin) to realize noncontact touch communications. A flexible self-sensing actuator was developed to provide an integrated function in both tactile sensing and haptic feedback. When this e-skin was dynamically pressed, the actuator generated an induced voltage as tactile information. Via wireless communication, another e-skin could receive this tactile data and run a synchronized haptic reproduction. Thus, touch could be wirelessly conveyed in bidirections between two users as a touch intercom. Furthermore, this e-skin could be connected with various smart devices to form a touch internet of things where one-to-one and one-to-multiple touch delivery could be realized. This wireless touch presents huge potentials in remote touch video, medical care/assistance, education, and many other applications.

15.
Nano Lett ; 22(14): 5944-5953, 2022 07 27.
Artículo en Inglés | MEDLINE | ID: mdl-35816764

RESUMEN

A combined treatment using medication and electrostimulation increases its effectiveness in comparison with one treatment alone. However, the organic integration of two strategies in one miniaturized system for practical usage has seldom been reported. This article reports an implantable electronic medicine based on bioresorbable microneedle devices that is activated wirelessly for electrostimulation and sustainable delivery of anti-inflammatory drugs. The electronic medicine is composed of a radio frequency wireless power transmission system and a drug-loaded microneedle structure, all fabricated with bioresorbable materials. In a rat skeletal muscle injury model, periodic electrostimulation regulates cell behaviors and tissue regeneration while the anti-inflammatory drugs prevent inflammation, which ultimately enhance the skeletal muscle regeneration. Finally, the electronic medicine is fully bioresorbable, excluding the second surgery for device removal.


Asunto(s)
Implantes Absorbibles , Terapia por Estimulación Eléctrica , Animales , Sistemas de Liberación de Medicamentos , Electrónica Médica , Ondas de Radio , Ratas , Tecnología Inalámbrica
16.
Nano Lett ; 22(8): 3447-3456, 2022 04 27.
Artículo en Inglés | MEDLINE | ID: mdl-35411774

RESUMEN

Transient power sources with excellent biocompatibility and bioresorablility have attracted significant attention. Here, we report high-performance, transient glucose enzymatic biofuel cells (TEBFCs) based on the laser-induced graphene (LIG)/gold nanoparticles (Au NPs) composite electrodes. Such LIG electrodes can be easily fabricated from polyimide (PI) with an infrared CO2 laser and exhibit a low impedance (16 Ω). The resulted TEBFC yields a high open circuit potential (OCP) of 0.77 V and a maximum power density of 483.1 µW/cm2. The TEBFC not only exhibits a quick response time that enables reaching the maximum OCP within 1 min but also owns a long lifetime over 28 days in vitro. The excellent biocompatibility and transient performance from in vitro and in vivo tests allow long-term implantation of TEBFCs in rats for energy harvesting. The TEBFCs with advanced processing methods provide a promising power solution for transient electronics.


Asunto(s)
Fuentes de Energía Bioeléctrica , Grafito , Nanopartículas del Metal , Animales , Electrodos , Oro , Rayos Láser , Ratas
17.
Sci Adv ; 8(2): eabl6700, 2022 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-35030019

RESUMEN

The coronavirus pandemic has highlighted the importance of developing intelligent robotics to prevent infectious disease spread. Human-machine interfaces (HMIs) give a chance of interactions between users and robotics, which play a significant role in teleoperating robotics. Conventional HMIs are based on bulky, rigid, and expensive machines, which mainly focus on robots/machines control, but lack of adequate feedbacks to users, which limit their applications in conducting complicated tasks. Therefore, developing closed-loop HMIs with both accurate sensing and feedback functions is extremely important. Here, we present a closed-loop HMI system based on skin-integrated electronics, whose electronics compliantly interface with the whole body for wireless motion capturing and haptic feedback via Bluetooth, Wireless Fidelity (Wi-Fi), and Internet. The integration of visual and haptic VR via skin-integrated electronics together into a closed-loop HMI for robotic VR demonstrates great potentials in noncontact collection of bio samples, nursing infectious disease patients and many others.

18.
Adv Sci (Weinh) ; 9(9): e2104635, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35088587

RESUMEN

Wearable electronics have attracted extensive attentions over the past few years for their potential applications in health monitoring based on continuous data collection and real-time wireless transmission, which highlights the importance of portable powering technologies. Batteries are the most used power source for wearable electronics, but unfortunately, they consist of hazardous materials and are bulky, which limit their incorporation into the state-of-art skin-integrated electronics. Sweat-activated biocompatible batteries offer a new powering strategy for skin-like electronics. However, the capacity of the reported sweat-activated batteries (SABs) cannot support real-time data collection and wireless transmission. Focused on this issue, soft, biocompatible, SABs are developed that can be directly integrated on skin with a record high capacity of 42.5 mAh and power density of 7.46 mW cm-2 among the wearable sweat and body fluids activated batteries. The high performance SABs enable powering electronic devices for a long-term duration, for instance, continuously lighting 120 lighting emitting diodes (LEDs) for over 5 h, and also offers the capability of powering Bluetooth wireless operation for real-time recording of physiological signals for over 6 h. Demonstrations of the SABs for powering microfluidic system based sweat sensors are realized in this work, allowing real-time monitoring of pH, glucose, and Na+ in sweat.


Asunto(s)
Sudor , Dispositivos Electrónicos Vestibles , Suministros de Energía Eléctrica , Electrónica , Piel
19.
Biosensors (Basel) ; 11(11)2021 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-34821651

RESUMEN

Hemodynamic status has been perceived as an important diagnostic value as fundamental physiological health conditions, including decisive signs of fatal diseases like arteriosclerosis, can be diagnosed by monitoring it. Currently, the conventional hemodynamic monitoring methods highly rely on imaging techniques requiring inconveniently large numbers of operation procedures and equipment for mapping and with a high risk of radiation exposure. Herein, an ultra-thin, noninvasive, and flexible electronic skin (e-skin) hemodynamic monitoring system based on the thermal properties of blood vessels underneath the epidermis that can be portably attached to the skin for operation is introduced. Through a series of thermal sensors, the temperatures of each subsection of the arrayed sensors are observed in real-time, and the measurements are transmitted and displayed on the screen of an external device wirelessly through a Bluetooth module using a graphical user interface (GUI). The degrees of the thermal property of subsections are indicated with a spectrum of colors that specify the hemodynamic status of the target vessel. In addition, as the sensors are installed on a soft substrate, they can operate under twisting and bending without any malfunction. These characteristics of e-skin sensors exhibit great potential in wearable and portable diagnostics including point-of-care (POC) devices.


Asunto(s)
Monitoreo Fisiológico/instrumentación , Termografía , Dispositivos Electrónicos Vestibles , Tecnología Inalámbrica , Humanos , Piel
20.
Anal Biochem ; 589: 113493, 2020 01 15.
Artículo en Inglés | MEDLINE | ID: mdl-31682794

RESUMEN

Reduced nicotinamide adenine dinucleotide (NADH) plays a pivotal role in the electron-transfer chain of biological system. Analysis of many biological markers is based on the detection of the enzymatically generated NADH. In this paper, a sensitive hydrogen peroxide (H2O2) biosensor, fabricated by carbon nanotubes (CNTs)/tetrathiafulvalene (TTF)/horseradish peroxidase (HRP), was applied for detecting the NADH in a buffer containing methylene blue (MB) at low operating potential of - 0.3 V (vs. Ag/AgCl). Since the NADH could be oxidized by MB to release H2O2, the electrochemical biosensor enables to detect the NADH in the MB buffer. And the low working potential made the biosensor avoid the interference from other electroactive substances. Linear response ranges from 10 µM to 790 µM, with a sensitivity of 4.76 µA mM-1 and a detection limit of 1.53 µM were obtained under the optimum conditions. The proposed sensor provided a promising approach for sensitively detecting the NADH.


Asunto(s)
Técnicas Biosensibles/métodos , NAD/análisis , Electroquímica , Electrodos , Enzimas Inmovilizadas/química , Compuestos Heterocíclicos/química , Peroxidasa de Rábano Silvestre/química , Peróxido de Hidrógeno/química , Concentración de Iones de Hidrógeno , Azul de Metileno/química , Nanotubos de Carbono/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA