Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 215
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38692478

RESUMEN

OBJECTIVES: Traditional criterion for intervention on an asymptomatic ascending aortic aneurysm has been a maximal aortic diameter of 5.5 cm or more. The 2022 American College of Cardiology/American Heart Association aortic guidelines adopted cross-sectional aortic area/height ratio, aortic size index, and aortic height index as alternate parameters for surgical intervention. The objective of this study was to evaluate the impact of using these newer indices on patient eligibility for surgical intervention in a prospective, multicenter cohort with moderate-sized ascending aortic aneurysms between 5.0 and 5.4 cm. METHODS: Patients enrolled from 2018 to 2023 in the randomization or registry arms of the multicenter trial, Treatment In Thoracic Aortic aNeurysm: Surgery versus Surveillance, were included in the study. Clinical data were captured prospectively in an online database. Imaging data were derived from a core computed laboratory. RESULTS: Among the 329 included patients, 20% were female. Mean age was 65.0 ± 11.6 years, and mean maximal aortic diameter was 50.8 ± 3.9 mm. In the one-third of all patients (n = 109) who met any 1 of the 3 criteria (ie, aortic size index ≥3.08 cm/m2, aortic height index ≥3.21 cm/m, or cross-sectional aortic area/height ≥ 10 cm2/m), their mean maximal aortic diameter was 52.5 ± 0.52 mm. Alternate criteria were most commonly met in women compared with men: 20% versus 2% for aortic size index (P < .001), 39% versus 5% for aortic height index (P < .001), and 39% versus 21% for cross-sectional aortic area/height (P = .002), respectively. CONCLUSIONS: One-third of patients in Treatment In Thoracic Aortic aNeurysm: Surgery versus Surveillance would meet criteria for surgical intervention based on novel parameters versus the classic definition of diameter 5.5 cm or more. Surgical thresholds for aortic size index, aortic height index, or cross-sectional aortic area/height ratio are more likely to be met in female patients compared with male patients.

2.
JACC Cardiovasc Interv ; 17(8): 1032-1044, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38456883

RESUMEN

BACKGROUND: The fifth-generation SAPIEN 3 Ultra Resilia valve (S3UR) incorporates several design changes as compared with its predecessors, the SAPIEN 3 (S3) and SAPIEN 3 Ultra (S3U) valves, including bovine leaflets treated with a novel process intended to reduce structural valve deterioration via calcification, as well as a taller external skirt on the 29-mm valve size to reduce paravalvular leak (PVL). The clinical performance of S3UR compared with S3 and S3U in a large patient population has not been previously reported. OBJECTIVES: The aim of this study was to compare S3UR to S3/S3U for procedural, in-hospital, and 30-day clinical and echocardiographic outcomes after transcatheter aortic valve replacement (TAVR). METHODS: Patients enrolled in the STS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between January 1, 2021, and June 30, 2023, who underwent TAVR with S3UR or S3U/S3 valve platforms were propensity-matched and evaluated for procedural, in-hospital, and 30-day clinical and echocardiographic outcomes. RESULTS: 10,314 S3UR patients were propensity matched with 10,314 patients among 150,539 S3U/S3 patients. At 30 days, there were no statistically significant differences in death, stroke, or bleeding, but a numerically higher hospital readmission rate in the S3UR cohort (8.5% vs 7.7%; P = 0.04). At discharge, S3UR patients exhibited significantly lower mean gradients (9.2 ± 4.6 mm Hg vs 12.0 ± 5.7 mm Hg; P < 0.0001) and larger aortic valve area (2.1 ± 0.7 cm2 vs 1.9 ± 0.6 cm2; P < 0.0001) than patients treated with S3/S3U. The 29-mm valve size exhibited significant reduction in mild PVL (5.3% vs 9.4%; P < 0.0001). CONCLUSIONS: S3UR TAVR is associated with lower mean gradients and lower rates of PVL than earlier generations of balloon expandable transcatheter heart valve platforms.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Valvuloplastia con Balón , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Recuperación de la Función , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Valvuloplastia con Balón/efectos adversos , Hemodinámica , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Estados Unidos
4.
Circulation ; 149(9): 658-668, 2024 02 27.
Artículo en Inglés | MEDLINE | ID: mdl-38084590

RESUMEN

BACKGROUND: Deep hypothermia has been the standard for hypothermic circulatory arrest (HCA) during aortic arch surgery. However, centers worldwide have shifted toward lesser hypothermia with antegrade cerebral perfusion. This has been supported by retrospective data, but there has yet to be a multicenter, prospective randomized study comparing deep versus moderate hypothermia during HCA. METHODS: This was a randomized single-blind trial (GOT ICE [Cognitive Effects of Body Temperature During Hypothermic Circulatory Arrest]) of patients undergoing arch surgery with HCA plus antegrade cerebral perfusion at 4 US referral aortic centers (August 2016-December 2021). Patients were randomized to 1 of 3 hypothermia groups: DP, deep (≤20.0 °C); LM, low-moderate (20.1-24.0 °C); and HM, high-moderate (24.1-28.0 °C). The primary outcome was composite global cognitive change score between baseline and 4 weeks postoperatively. Analysis followed the intention-to-treat principle to evaluate if: (1) LM noninferior to DP on global cognitive change score; (2) DP superior to HM. The secondary outcomes were domain-specific cognitive change scores, neuroimaging findings, quality of life, and adverse events. RESULTS: A total of 308 patients consented; 282 met inclusion and were randomized. A total of 273 completed surgery, and 251 completed the 4-week follow-up (DP, 85 [34%]; LM, 80 [34%]; HM, 86 [34%]). Mean global cognitive change score from baseline to 4 weeks in the LM group was noninferior to the DP group; likewise, no significant difference was observed between DP and HM. Noninferiority of LM versus DP, and lack of difference between DP and HM, remained for domain-specific cognitive change scores, except structured verbal memory, with noninferiority of LM versus DP not established and structured verbal memory better preserved in DP versus HM (P = 0.036). There were no significant differences in structural or functional magnetic resonance imaging brain imaging between groups postoperatively. Regardless of temperature, patients who underwent HCA demonstrated significant reductions in cerebral gray matter volume, cortical thickness, and regional brain functional connectivity. Thirty-day in-hospital mortality, major morbidity, and quality of life were not different between groups. CONCLUSIONS: This randomized multicenter study evaluating arch surgery HCA temperature strategies found low-moderate hypothermia noninferior to traditional deep hypothermia on global cognitive change 4 weeks after surgery, although in secondary analysis, structured verbal memory was better preserved in the deep group. The verbal memory differences in the low- and high-moderate groups and structural and functional connectivity reductions from baseline merit further investigation and suggest opportunities to further optimize brain perfusion during HCA. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02834065.


Asunto(s)
Aorta Torácica , Hipotermia , Humanos , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Estudios Retrospectivos , Estudios Prospectivos , Calidad de Vida , Método Simple Ciego , Temperatura Corporal , Paro Circulatorio Inducido por Hipotermia Profunda/efectos adversos , Perfusión/efectos adversos , Perfusión/métodos , Cognición , Circulación Cerebrovascular , Resultado del Tratamiento
5.
J Vasc Surg ; 79(4): 711-720.e2, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38008268

RESUMEN

OBJECTIVE: Since its inception in the early 2000s, hybrid arch repair (HAR) has evolved from novel approach to well-established treatment modality for aortic arch pathology in appropriately selected patients. Despite this nearly 20-year history of use, long-term results of HAR remain to be determined. As such, objectives of this study are to detail the long-term outcomes for HAR within an expanded classification scheme. METHODS: From August 2005 to August 2022, 163 consecutive patients underwent HAR at a single referral institution. Operative approach was selected according to an institutional algorithm and included zone 0/1 HAR in 25% (n = 40), type I HAR in 34% (n = 56), and type II/III HAR in 41% (n = 67). Specific zone 0/1 technique was zone 1 HAR in 31 (78%), zone 0 with innominate snorkel (zone 0S HAR) in 7 (18%), and zone 0 with single side-branch endograft (zone 0B HAR) in 2 (5%). The 30-day and long-term outcomes, including overall and aortic-specific survival, as well as freedom from reintervention, were assessed. RESULTS: The mean age was 63 ± 13 years and almost one-half of patients (47% [n = 77]) had prior sternotomy. Presenting pathology included degenerative aneurysm in 44% (n = 71), residual dissection after prior type A repair in 38% (n = 62), chronic type B dissection in 12% (n = 20), and other indications in 6% (n = 10). Operative outcomes included 9% mortality (n = 14) at 30 days, 5% mortality (n = 8) in hospital, 4% stroke (n = 7), 2% new dialysis (n = 3), and 2% permanent paraparesis/plegia (n = 3). The median follow-up was 44 month (interquartile range, 12-84 months). Overall survival was 59% and 47% at 5 and 10 years, respectively, whereas aorta-specific survival was 86% and 84% at the same time points. At 5 and 10 years, freedom from major reintervention was 92% and 91%, respectively. Institutional experience had a significant impact on both early and late outcomes: comparing the first (2005-2012) and second (2013-2022) halves of the series, 30-day mortality decreased from 14% to 1% (P = .01) and stroke from 6% to 3% (P = .62). Improved operative outcomes were accompanied by improved late survival, with 78% of patients in the later era vs 45% in the earlier era surviving to 5 years. CONCLUSIONS: HAR is associated with excellent operative outcomes, as well as sustained protection from adverse aortic events as evidenced by high long-term aorta-specific survival and freedom from reintervention. However, surgeon and institutional experience appear to play a major role in achieving these superior outcomes, with a five-fold decrease in operative mortality and a two-fold decrease in stroke rate in the latter half of the series. These long-term results expand on prior midterm data and continue to support use of HAR for properly selected patients with arch disease.


Asunto(s)
Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Accidente Cerebrovascular , Humanos , Persona de Mediana Edad , Anciano , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/etiología , Resultado del Tratamiento , Factores de Riesgo , Estudios Retrospectivos , Estimación de Kaplan-Meier , Complicaciones Posoperatorias , Accidente Cerebrovascular/etiología
7.
Eur J Cardiothorac Surg ; 64(6)2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-38006340

RESUMEN

OBJECTIVES: The Hemispherical Aortic Annuloplasty Reconstructive Technology (HAART) ring is a rigid, internal and geometric device. The objective of this article is to assess the mid-term outcomes of aortic valve repair (AVr) using this prosthesis. METHODS: A prospectively maintained database was used to obtain outcomes for adult patients undergoing AVr using the HAART ring between September 2017 and June 2023. All aortic patients at our institution undergo life-long surveillance with regular assessment and valve imaging. RESULTS: Seventy-one patients underwent AVr using the HAART device: 53 had a trileaflet valve and 18 a bicuspid valve. The median age was 54 years, and most were male (79%). Many required concomitant intervention: 46% had a root procedure and 77% an arch repair. There were no in-hospital deaths, and the median postoperative stay was 5 days. At a mean follow-up of 3.9 (±1.1) years, freedom from reoperation was 94%. Late imaging demonstrated: zero trace (25%), 1+ (54%), 2+ (15%) and 4+ (6%) aortic insufficiency (AI). Eleven patients have ≥moderate AI under surveillance, all of whom have a trileaflet valve (21% of trileaflet patients). Four patients required reoperation: 3 for ring dehiscence and 1 for endocarditis. CONCLUSIONS: Although early results using the HAART device are encouraging, mid-term results raise concern as 21% of trileaflet patients developed recurrent ≥moderate AI by 4 years post-repair. We experienced 3 incidences of ring dehiscence requiring reoperation. Based on this, we recommend caution using the sub-annular approach for stabilization in patients with trileaflet aortic valves. Long-term results are needed to assess outcomes against established techniques.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Anuloplastia de la Válvula Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Adulto , Humanos , Masculino , Persona de Mediana Edad , Femenino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Válvula Mitral/cirugía , Anuloplastia de la Válvula Cardíaca/métodos , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Reoperación , Resultado del Tratamiento
8.
Innovations (Phila) ; 18(5): 452-458, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37753830

RESUMEN

OBJECTIVE: Controversy remains regarding the optimal neuroprotection strategy for elective hemiarch replacement (HEMI). This study sought to compare outcomes in patients who underwent HEMI utilizing the 2 most common contemporary methods of cerebral protection. METHODS: The ARCH international aortic database was queried, and 782 patients undergoing elective HEMI with circulatory arrest from 2007 to 2012 were identified. There were 418 patients who underwent HEMI using moderate hypothermia (nasopharyngeal temperature 20.1 to 28.0 °C) and antegrade cerebral perfusion (MHCA/ACP). There were 364 patients who underwent HEMI using deep hypothermia (nasopharyngeal temperature 14.1 to 20 °C) and retrograde cerebral perfusion (DHCA/RCP). Adverse outcomes were compared between the groups using both univariable and multivariable analyses. RESULTS: Patients who underwent MHCA/ACP were older (64 vs 61 years, P = 0.01) and more frequently had peripheral vascular disease than DHCA/RCP patients (28.5% vs 7.1%, P < 0.001). Patients in the DHCA/RCP group had a greater incidence of full aortic root replacement (55.8% vs 26.4%, P < 0.001) and more frequently had a central cannulation strategy (83% vs 55.7%, P < 0.001). Cardiopulmonary bypass (170 vs 157 min, P = 0.002) and aortic cross-clamp (134 vs 92 min, P < 0.001) times were significantly longer in the DHCA/RCP group. On univariable analysis, overall mortality was statistically similar between groups (MHCA/ACP 3.4% vs DHCA/RCP 2.3%, P = 0.47), but permanent neurologic deficits were significantly lower in the DHCA/RCP cohort (MHCA/ACP 3.9% vs DHCA/RCP 1.0%, P = 0.02). Multivariable analysis showed no difference in mortality nor perioperative stroke between perfusion cohorts. CONCLUSIONS: Both MHCA/ACP and DHCA/RCP are excellent neuroprotective strategies that produce low mortality in patients undergoing elective HEMI. DHCA/RCP may demonstrate theoretically improved neurologic outcomes compared with MHCA/ACP, but this topic warrants further study.

10.
Eur J Vasc Endovasc Surg ; 65(4): 612, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36804413
13.
J Thorac Cardiovasc Surg ; 165(2): 554-565.e6, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-33814173

RESUMEN

OBJECTIVE: The best method of aortic root repair in older patients remains unknown given a lack of comparative effectiveness of long-term outcomes data. The objective of this study was to compare long-term outcomes of different surgical approaches for aortic root repair in Medicare patients using The Society of Thoracic Surgeons Adult Cardiac Surgery Database-Centers for Medicare & Medicaid Services-linked data. METHODS: A retrospective cohort study was performed by querying the Society of Thoracic Surgeons Adult Cardiac Surgery Database for patients aged 65 years or more who underwent elective aortic root repair with or without aortic valve replacement. Primary long-term end points were mortality, any stroke, and aortic valve reintervention. Short-term outcomes and long-term survival were compared among each root repair strategy. Additional risk factors for mortality after aortic root repair were assessed with a multivariable Cox proportional hazards model. RESULTS: A total of 4173 patients aged 65 years or more underwent elective aortic root repair. Patients were stratified by operative strategy: mechanical Bentall, stented bioprosthetic Bentall, stentless bioprosthetic Bentall, or valve-sparing root replacement. Mean follow-up was 5.0 (±4.6) years. Relative to mechanical Bentall, stented bioprosthetic Bentall (adjusted hazard ratio, 0.80; confidence interval, 0.66-0.97) and stentless bioprosthetic Bentall (adjusted hazard ratio, 0.70; confidence interval, 0.59-0.84) were associated with better long-term survival. In addition, stentless bioprosthetic Bentall (adjusted hazard ratio, 0.64; confidence interval, 0.47-0.80) and valve-sparing root replacement (adjusted hazard ratio, 0.51; confidence interval, 0.29-0.90) were associated with lower long-term risk of stroke. Aortic valve reintervention risk was 2-fold higher after valve-sparing root replacement compared with other operative strategies. CONCLUSIONS: In the Medicare population, there was poorer late survival and greater late stroke risk for patients undergoing mechanical Bentall and a higher rate of reintervention for valve-sparing root replacement. Bioprosthetic Bentall may be the procedure of choice in older patients undergoing aortic root repair, particularly in the era of transcatheter aortic valve replacement.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Accidente Cerebrovascular , Adulto , Humanos , Anciano , Estados Unidos , Aorta Torácica/cirugía , Estudios Retrospectivos , Medicare , Resultado del Tratamiento , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos
14.
J Thorac Cardiovasc Surg ; 166(4): 996-1008.e1, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-35282930

RESUMEN

OBJECTIVE: After limited root/ascending with or without hemiarch repair for acute type A aortic dissection (ATAAD), 20% to 30% of patients require distal reintervention, frequently for arch pathology. In this report, we describe an institutional algorithm for arch management after previous limited ATAAD repair and detail operative and long-term outcomes. METHODS: From August 2005 to April 2021, 71 patients status post previous limited ATAAD repair underwent reoperative arch repair involving zones 1 to 3 for aneurysmal degeneration of residual arch dissection including complete cervical debranching with zone 0/1 thoracic endovascular aortic repair in 6 (8%), open total arch in 13 (18%), type I hybrid arch repair in 23 (32%), and type II/III hybrid arch repair in 29 (41%). RESULTS: Mean age was 59 ± 12 years; time from index ATAAD repair to reoperation was 4 (interquartile range, 2-9) years. There were 2 (2.8%) in-hospital deaths and 2 (2.8%) postdischarge deaths within 30 days of surgery. Three patients suffered stroke (4.2%) and 2 (2.8%) had acute renal failure requiring dialysis. Overall Kaplan-Meier survival was 78%, 70%, and 58% at 1, 3, and 5 years, respectively. Institutional experience appeared to play a significant role in early and late outcomes, because there have been no operative mortalities in the past 9 years and improved survival of 87% versus 66%, 79% versus 58%, and 79% versus 40% at 1, 3, and 5 years in comparisons of the past 9 years with the previous era (P = .01). CONCLUSIONS: Aneurysmal degeneration of residual arch dissection after limited ATAAD repair presents a complex reoperative challenge. An algorithmic operative approach tailored to patient anatomy and comorbidities yields excellent early and late outcomes, which continue to improve with increasing institutional experience.


Asunto(s)
Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Persona de Mediana Edad , Anciano , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Implantación de Prótesis Vascular/efectos adversos , Cuidados Posteriores , Procedimientos Endovasculares/efectos adversos , Alta del Paciente , Diálisis Renal
15.
Eur J Vasc Endovasc Surg ; 65(1): 112-119, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36209962

RESUMEN

OBJECTIVE: Endoleaks following thoracic endovascular aortic repair (TEVAR) can lead to the need for re-intervention and aortic rupture. Given the recent recall of a specific thoracic stent graft type due to concerns about type IIIb endoleak (T3bE), in which blood leaks through the stent graft fabric, the aim was to characterise patterns of T3bEs among available TEVAR devices. METHODS: Reports related to thoracic stent grafts in the Food and Drug Administration's (FDA) Manufacturer and User Facility Device Experience (MAUDE) database between 2010 and 2020 were reviewed. Proportional reporting ratios (PRRs) and chi squared tests were used to assess for the presence of a signal of association between device type and T3bE. A PRR > 2 and chi squared value > 4 with three or more reports overall constituted a signal of association. The institutional database of patients undergoing TEVAR for thoracic aneurysms since 2002 was also queried for T3bE. RESULTS: There were 7 328 MAUDE reports available for analysis. When analysing T3bEs in the MAUDE database, the lowest PRR was 0.36 (95% confidence interval [CI] 0 - 1.03 in Gore CTAG, nine T3bE among 1 328 reports) and the highest was 2.07 (95% CI 1.72 - 2.42 in Medtronic Valiant, 64 T3bE among 2 520 reports). The T3bE chi squared value for Medtronic Valiant was 17.3. The relationship between Medtronic Valiant and T3bE was ascertainable by MAUDE data as early as 2013. Among 542 TEVARs for an aneurysm indication at Duke University Hospital since 2002, there were eight T3bEs - all in devices with sutured on graft material. CONCLUSION: The Medtronic Valiant device met criteria for association with type IIIb endoleaks in the FDA's MAUDE database and met those criteria as early as 2013. A possible relationship between woven graft fabric and T3bEs is supported by the observation that all types of T3bE that occurred among a large number of TEVARs at the institution followed placement of grafts with sutured on woven fabric.


Asunto(s)
Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Endofuga/etiología , Endofuga/cirugía , Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Reparación Endovascular de Aneurismas , Resultado del Tratamiento , Procedimientos Endovasculares/efectos adversos , Stents , Aneurisma de la Aorta Torácica/cirugía , Diseño de Prótesis , Estudios Retrospectivos
16.
Ann Thorac Surg ; 115(2): 378-385, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-35872034

RESUMEN

BACKGROUND: Selective sinus replacement (SSR) allows a tailored repair approach in patients with sinus of Valsalva or asymmetric aortic root aneurysm. SSR avoids the need for coronary reimplantation for nondiseased sinuses and shortens operative time, although potential for late growth of retained sinuses exists. This study describes selection of patients and assesses operative outcomes and late root dimensions after SSR. METHODS: From 2006 to 2020, 60 patients underwent SSR at a single referral institution. Mixed effect models were used to assess trajectory of postoperative growth of remaining sinuses, adjusting for age of the patient, valve morphology, and baseline root diameter. RESULTS: Median age of the patients was 57 (interquartile range [IQR], 48-65) years. Twenty-four (40%) had a bicuspid aortic valve. Most patients (n = 55 [92%]) underwent single sinus replacement (n = 46 noncoronary, n = 9 right), whereas 5 (8%) underwent repair of both the right and noncoronary sinuses. Concomitant aortic valve replacement was performed in 15 patients (25%); aortic valve repair with internal ring annuloplasty or cusp plication was performed in 37 (62%). There was no operative death, stroke, renal failure, or respiratory failure. Median preoperative root diameter was 53 mm (IQR, 51-56 mm) vs 42 mm (IQR, 39-45 mm) at median imaging follow-up of 34 (IQR, 13-49) months. Rate of midterm root growth was 0.2 mm/y, and there were no late root reinterventions. CONCLUSIONS: For patients with sinus of Valsalva or asymmetric root aneurysm, SSR is associated with excellent operative outcomes, and midterm follow-up suggests that the technique is durable. Longer term follow-up is needed to confirm continued stability of the aortic root.


Asunto(s)
Aneurisma de la Aorta Torácica , Aneurisma de la Raíz de la Aorta , Insuficiencia de la Válvula Aórtica , Humanos , Persona de Mediana Edad , Anciano , Insuficiencia de la Válvula Aórtica/cirugía , Aneurisma de la Aorta Torácica/cirugía , Válvula Aórtica/cirugía , Reimplantación , Resultado del Tratamiento , Estudios Retrospectivos
17.
Ann Thorac Surg ; 115(2): 394-395, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-35944703
19.
JTCVS Tech ; 13: 4-6, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35711195
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA